Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH: Multi-contact cuff electrodes were implanted in the median, ulnar, and radial nerves of the upper-limb. MAIN RESULTS: Nerve stimulation produced a selective sensory response on 19 of 20 contacts and 16 of 16 contacts in subjects 1 and 2, respectively. Stimulation elicited multiple, distinct percept areas on the phantom and residual limb. Consistent threshold, impedance, and percept areas have demonstrated that the neural interface is stable for the duration of this on-going, chronic study. SIGNIFICANCE: We have achieved selective nerve response from multi-contact cuff electrodes by demonstrating characteristic percept areas and thresholds for each contact. Selective sensory response remains consistent in two upper-limb amputees for 1 and 2 years, the longest multi-contact sensory feedback system to date. Our approach demonstrates selectivity and stability can be achieved through an extraneural interface, which can provide sensory feedback to amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A study by Tan et al. succeeded in stimulating 10 and 15 unique precept areas on a phantom hand using electrodes implanted for one and two years.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Tan et al., 2015
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In somatosensory applications, intensity is proportional to the variation of the stimulation frequency, and the resulting sensory perceptions can be changed with bursting pulse trains (Tan et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tan et al., 2015
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Stability and selectivity have been achieved for longer periods of time, for instance, more than 3 years using the cuff-type interface (Tan et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tan et al., 2015
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“So far, however, both techniques have yielded projection fields whose sizes are roughly comparable (Raspopovic et al., 2014;Tan et al., 2015).”
From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Tan et al., 2015
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Stimulation of the nerve has been shown to induce a variety of sensations with complex qualities, such as tapping on the skin, vibration, tingling, stinging, brushing, and itch (Clark et al., 2014;Tan et al., 2015;2014).”
From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Tan et al., 2015
Experimental — accuracy not yet measured
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 4×
“The long term safety and stability of intrafascicular electrodes remain unknown because these trials were four weeks or less in duration and often reported an upward trend in stimulation threshold [7, 9, 14].”
BackgroundInfluentialA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Effect of sensory discrimination training on cortical reorganisation and phantom limb pain
Flor, H., Denke, C., Schaefer, M., & Grüsser, S. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04890-x · Cited by 560 · cited 1×
“tion of uncomfortable phantom limb sensation [7, 8].”
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · cited 1×
“The result is unique in that prior intrafascicular nerve interfaces described a loss in available channels over time, either from mechanical failure [13] or a reactive environment leading to worsening recording or stimulating capability [7, 46].”
BackgroundTHE INTRANEURAL TOPOGRAPHY OF THE RADIAL, MEDIAN AND ULNAR NERVES
SUNDERLAND, S. (1945) · Brain · doi:10.1093/brain/68.4.243 · Cited by 426
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 1×
“The Case Western Reserve University (CWRU) self-sizing spiral electrode [21], which has been used extensively in restoring motor control in SCI patients [22, 23], is also used in this study to provide sensory feedback.”
MethodFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 2×
“However, with only 2-4 week acute clinical trials, and rising stimulation threshold trends, the long term safety and stability of intrafascicular electrodes are unknown [3], [4].”
BackgroundSources and effects of electrode impedance during deep brain stimulation
Butson, C. R., Maks, C. B., & McIntyre, C. C. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.007 · Cited by 360
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257 · cited 1×
“natural sensory feedback in their prostheses [2, 3].”
Movement illusions evoked by ensemble cutaneous input from the dorsum of the human hand.
Collins, D. F., & Prochazka, A. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021733 · Cited by 214
The application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 4×
“object size and compliance discrimination [10] and shape”
BackgroundInfluentialAgnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185 · cited 1×
“To prevent overstimulation, the stimulation was limited to less than 50% duty cycle[12].”
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 2×
“pressure feedback [51, 52] and to provide positional feedback”
BackgroundHollinshead's Functional Anatomy of the Limbs and Back
Jenkins, D. B. (1998) · Medical Entomology and Zoology · Cited by 151
Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150 · cited 1×
“Sensory feedback may improve control of the prosthetic hand [6], [7].”
BackgroundSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148
Self-citationFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1×
“Based on modeling studies on the influence of neighboring fascicles, two fascicles may be moving slightly into and out of the stimulus field such that one or the other, but not both, results with activated axons [20].”
BackgroundSelf-citationChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · cited 2×
“Eight-contact Flat Interface Nerve Electrodes (FINE) [5] were implanted on the median and ulnar nerves and a 4-contact CWRU spiral electrode [8] was implanted on the radial nerve.”
BackgroundMethodSelf-citationPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · cited 1×
“All electrodes were in the mid-forearm and connected to percutaneous leads [9], [10], [11] that exited through the upper arm (Fig.”
BackgroundSelf-citationSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 1×
“This is on average greater than previous studies of motor recruitment of 25±17 nC found during chronic studies with a spiral nerve cuff implanted on upper extremity nerves in humans [14] and the 21±18 nC found during interoperative studies with the FINE cuff implanted on lower extremity nerves in humans [15].”
ResultSelf-citationA single-interval adjustment-matrix (SIAM) procedure for unbiased adaptive testing
Kaernbach, C. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399985 · Cited by 122
Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · cited 1×
“This is on average greater than previous studies of motor recruitment of 25±17 nC found during chronic studies with a spiral nerve cuff implanted on upper extremity nerves in humans [14] and the 21±18 nC found during interoperative studies with the FINE cuff implanted on lower extremity nerves in humans [15].”
ResultSelf-citationRetrograde changes in fibre size following nerve section.
Aitken, J. T., & Thomas, P. K. (1962) · PubMed Central · Cited by 101
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98 · cited 1×
“Sensory feedback may improve control of the prosthetic hand [6], [7].”
BackgroundFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · cited 1×
“The Case Western Reserve University (CWRU) self-sizing spiral electrode [21], which has been used extensively in restoring motor control in SCI patients [22, 23], is also used in this study to provide sensory feedback.”
MethodSelf-citation(1974) · PubMed · Cited by 89
Hollinshead's Functional Anatomy of the Limbs and Back
Caladine, L. K. (1991) · Physiotherapy · doi:10.1016/s0031-9406(10)60412-9 · Cited by 84
Björkman, A., Weibull, A., Rosén, B., Svensson, J., & Lundborg, G. (2009) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.06629.x · Cited by 73
Quantification of human upper extremity nerves and fascicular anatomy
Brill, N. A., & Tyler, D. J. (2017) · Muscle & Nerve · doi:10.1002/mus.25534 · Cited by 64
Self-citationSchiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57 · cited 2×
“This is, on average, greater than the 25 ± 17 nC found in previous chronic motor recruitment studies with a spiral nerve cuff implanted on upper extremity nerves in humans [37], and 21 ± 18and 41 ± 36 nC found during intraoperative studies with the FINE cuff implanted on lower extremity nerves in humans [18, 38].”
BackgroundSelf-citationInvestigation of the functional correlates of reorganization within the human somatosensory cortex
Moore, C. E. G. (2000) · Brain · doi:10.1093/brain/123.9.1883 · Cited by 56
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Self-citationKnutson, J. S., Naples, G. G., Peckham, P. H., & Keith, M. W. (2002) · PubMed · Cited by 51
Self-citationIn-line lead connector for use with implanted neuroprosthesis
Letechipia, J. E., Peckham, P. H., Gazdik, M., & Smith, B. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83572 · Cited by 47
Humans Can Integrate Force Feedback to Toes in Their Sensorimotor Control of a Robotic Hand
Panarese, A., Edin, B. B., Vecchi, F., Carrozza, M. C., & Johansson, R. S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021689 · Cited by 47
Regenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46
Prodanov, D., Nagelkerke, N., & Marani, E. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.08.017 · Cited by 45
Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33 · cited 2×
“Stimulation was limited to less than a charge density of 0.5 μCmm−2 [27, 28] and limited to less than 50% of the duty cycle [29].”
BackgroundInfluentialSelf-citationAnani, A., & Körner, L. K. (1979) · PubMed · Cited by 33
Long-term effects of partial limb amputation in man.
McComas, A. J., Sica, R. E. P., & Banerjee, S. (1978) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.41.5.425 · Cited by 27
Louboutin, J., Fichter-Gagnepain, V., & Noireaud, J. (1996) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199608)19:8<1049::aid-mus14>3.0.co;2-s · Cited by 22
Population behaviour of human cutaneous mechanoreceptive units
Hallin, R. G., Carlstedt, T. P., & Wu, G. (2002) · Behavioural Brain Research · doi:10.1016/s0166-4328(02)00150-x · Cited by 11
Hallin, R. G., & Wu, G. (2002) · Behavioural Brain Research · doi:10.1016/s0166-4328(02)00149-3 · Cited by 8
Optimization of High Density Nerve Cuff Stimulation in Upper Extremity Nerves
Brill, N. (2015) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Sensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citation
Metadata
- Authors
- Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J.
- Affiliations
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Tyler, Dustin J
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-01-28
- Volume
- 12
- Issue
- 2
- Pages
- 026002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC5517311
- OpenAlex
- W2131130558
- Semantic Scholar
- cee2aeddee85da82ef0aeb070975665d67711e59
- Cited by
- 175
- References
- 55
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 15 · 2023: 18 · 2022: 14 · 2021: 20 · 2020: 18 · 2019: 20 · 2018: 24 · 2017: 10 · 2016: 11 · 2015: 4
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (Merit Review #A6156R)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sensory feedback, upper limb amputees, peripheral nerve stimulation, perceptual maps, stimulation threshold, electrode impedance, residual limb, median nerve, ulnar nerve, radial nerve
- MeSH terms
- Amputees, Arm, Electrodes, Implanted, Electric Stimulation Therapy, Equipment Design, Humans, Male, Middle Aged, Peripheral Nerves, Sensation, Sensitivity and Specificity, Reproducibility of Results, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.