Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients with diabetes during home use. METHODS: Performance data and demographic information were obtained from 135 patients who were (mean +/- SD) 40.5+/-14.5 years old, had an average duration of diabetes of 18.0+/-9.8 years, 50% were female, 90% were Caucasian, and 87% of whom had been diagnosed with type 1 diabetes. Patients were selected by their physician, trained on the use of the CGMS and wore the device at home for 3 days or more. The performance of the CGMS was evaluated against blood glucose measurements obtained using each patient's home blood glucose meter. Evaluation statistics included correlation, linear regression, mean difference and percent absolute difference scores, and Clarke error grid analysis. RESULTS: The CGMS values were compared to 2477 SMBG tests (r = 0.91, slope = 0.93, intercept = 14.5 mg/dL, mean absolute difference = 18.0%+/-19.8%). Clarke error grid analysis showed 96.2% of the data pairs falling within the clinically acceptable regions (zones A and B). CONCLUSIONS: These results demonstrate the agreement of the CGMS to blood glucose meter values, under conditions of home use, in patients selected by their physicians as candidates for continuous monitoring. The detailed glucose information provided by the CGMS should make successful management of diabetes more easily achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 423
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393
Self-citationBode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Self-citationA Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Can Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 213
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
“in a physician’s office [78].”
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Babu, A. R., Herdegen, J., Fogelfeld, L., Shott, S., & Mazzone, T. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.4.447 · Cited by 453
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 423
Association of Hypoglycemia and Cardiac Ischemia
Desouza, C., Salazar, H., Cheong, B., Murgo, J., & Fonseca, V. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1485 · Cited by 406
A Novel Approach to Continuous Glucose Analysis Utilizing Glycemic Variation
McDonnell, C. M., Donath, S. M., Vidmar, S. I., Werther, G. A., & Cameron, F. J. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.253 · Cited by 358
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
“T he premise behind increasing research and industrial efforts on the development of continuous glucose sensors (CGSs) is that the accurate assessment of blood glucose (BG) dynamics is a valuable tool for both everyday maintenance of diabetes and long-term effectiveness of glycemic control (1,2).”
BackgroundWearable electrochemical biosensors in North America
Min, J., Sempionatto, J. R., Teymourian, H., Wang, J., & Gao, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112750 · Cited by 278
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
“This system has been validated by several reports (7,8) and has been shown to provide a good correlation between blood and interstitial glucose levels (9–11).”
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
“surements of plasma glucose concentrations (5) and home glucose values (6).”
BackgroundType 1 diabetes mellitus: etiology, presentation, and management
Haller, M. J., Atkinson, M. A., & Schatz, D. (2005) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2005.07.006 · Cited by 211
“Real-time continuous glucose monitoring systems, which would provide readings on a digital screen every 5 minutes, are expected to be available in the near future [84].”
BackgroundDelays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198
Self-citationSerum 1,5-Anhydroglucitol (GlycoMark™): A Short-Term Glycemic Marker
Buse, J. B., Freeman, J. L. R., Edelman, S. V., Jovanovic, L., & McGill, J. B. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503765691839 · Cited by 187
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
Ratiometric Fluorescent Nanohybrid for Noninvasive and Visual Monitoring of Sweat Glucose
Cui, Y., Duan, W., Jin, Y., Wo, F., Xi, F., & Wu, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00718 · Cited by 177
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
“9 Though our study subject numbers were too small for detailed statistical analyses, potentially disruptive clinical issues such as edema, hypotension, and vasopressor therapy (all of which were present in some of our patients) did not appear to affect the accuracy of the CGMS.”
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Self-citationOverview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
“Some devices for continuous glucose measurement (CGM) have received the approval of the FDA [69,70].”
BackgroundAmin, R., Ross, K., Acerini, C. L., Edge, J. A., Warner, J., & Dunger, D. B. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.662 · Cited by 106
“The CGMS allows reliable assessment of true glycemic fluctuation through the day and night (19), and it provides an opportunity to study, relatively noninvasively, intraand interindividual variation in hypoglycemia prevalence.”
The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy
McLACHLAN, K., JENKINS, A., & O’NEAL, D. (2007) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.2007.00716.x · Cited by 82
Venugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76
“Thus, this device supplements invasive and noncontinuous blood glucose measurements [ 17 ]‐[19].”
MethodMeyer, G., Hackemann, A., Reusch, J., & Badenhoop, K. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0158 · Cited by 50
Kim, S. K., Kim, H. J., Kim, T., Hur, K. Y., Kim, S. W., Lee, M.-K., Min, Y.-K., Kim, K.-W., Chung, J. H., & Kim, J. H. (2014) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2014.38.6.449 · Cited by 23
“The continuous glucose monitoring system Gold (CGMS; Medtronic MiniMed, Northridge, CA, USA) provides retrospective glucose profiles that allow physicians to detect postprandial glucose excursions and hypoglycemia [7].”
BackgroundWatanabe, T., Ozawa, A., Ishii, S., Tomaru, T., Shibusawa, N., Saito, T., Yamada, E., Horiguchi, K., Nakajima, Y., Matsumoto, S., et al. (2018) · Endocrine Journal · doi:10.1507/endocrj.ej16-0387 · Cited by 22
Metadata
- Authors
- Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2000-05
- Volume
- 2
- Issue
- 1
- Pages
- 49-56
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2004749714
- Cited by
- 303
- References
- 20
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.