The DOI matches its Crossref record; 124 of the 124 references it cites were found in a registry or an index.
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
Open accessAbstract
In this review, we compare the reported values of Young's modulus (YM) obtained from indentation and tensile deformations of soft biological tissues. When the method of deformation is ignored, YM values for any given tissue typically span several orders of magnitude. If the method of deformation is considered, then a consistent and less ambiguous result emerges. On average, YM values for soft tissues are consistently lower when obtained by indentation deformations. We discuss the implications and potential impact of this finding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Surface energy and the contact of elastic solids
Johnson, K. L., Kendall, K., & Roberts, A. D. (1971) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1971.0141 · Cited by 8,061
Johnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Molecular Mechanisms of Stress-Responsive Changes in Collagen and Elastin Networks in Skin
Aziz, J., Shezali, H., Radzi, Z., Yahya, N. A., Abu Kassim, N. H., Czernuszka, J., & Rahman, M. T. (2016) · Skin Pharmacology and Physiology · doi:10.1159/000447017 · Cited by 7,323
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Ueber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941
A new constitutive framework for arterial wall mechanics and a comparative study of material models
Holzapfel, G. A., Gasser, T. C., & Ogden, R. W. (2000) · Journal of Elasticity · doi:10.1023/a:1010835316564 · Cited by 3,071
Cell locomotion and focal adhesions are regulated by substrate flexibility
Pelham, R. J., & Wang, Y.-L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13661 · Cited by 3,027
Ogden, R. W. (1972) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1972.0026 · Cited by 2,979
Growth Factors, Matrices, and Forces Combine and Control Stem Cells
Discher, D. E., Mooney, D. J., & Zandstra, P. W. (2009) · Science · doi:10.1126/science.1171643 · Cited by 2,667
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Matrigel: Basement membrane matrix with biological activity
Kleinman, H. K., & Martin, G. R. (2005) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2005.05.004 · Cited by 1,673
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Zaman, M. H., Trapani, L. M., Sieminski, A. L., MacKellar, D., Gong, H., Kamm, R. D., Wells, A., Lauffenburger, D. A., & Matsudaira, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604460103 · Cited by 1,160
Substrate Modulus Directs Neural Stem Cell Behavior
Saha, K., Keung, A. J., Irwin, E. F., Li, Y., Little, L., Schaffer, D. V., & Healy, K. E. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.132217 · Cited by 1,092
Scaling, dimensional analysis, and indentation measurements
Cheng, Y.-T., & Cheng, C.-M. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.05.001 · Cited by 1,061
Elasticity of soft tissues in simple elongation
Fung, Y. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.6.1532 · Cited by 1,029
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024
Application des potentiels : à l'etude de l'equilibre et du mouvement des solides élastiques
Boussinesq, J., & Caquot, M. A. (1885) · Medical Entomology and Zoology · Cited by 916
The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
Lötters, J. C., Olthuis, W., Veltink, P. H., & Bergveld, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/017 · Cited by 827
Nano-indentation of polymeric surfaces
Briscoe, B. J., Fiori, L., & Pelillo, E. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/19/006 · Cited by 760
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Griffith, L. G. (2000) · Acta Materialia · doi:10.1016/s1359-6454(99)00299-2 · Cited by 730
Viscoelastic properties of muscle-tendon units: The biomechanical effects of stretching
Taylor, D. C., Dalton, J. D., Seaber, A. V., & Garrett, W. E. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800314 · Cited by 725
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Uber die Beruhrung fester elastischer Korper
Hertz, H. G. (1882) · Medical Entomology and Zoology · Cited by 719
The effect of substrate stiffness on adult neural stem cell behavior
Leipzig, N. D., & Shoichet, M. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.002 · Cited by 686
Banerjee, A., Arha, M., Choudhary, S., Ashton, R. S., Bhatia, S. R., Schaffer, D. V., & Kane, R. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.050 · Cited by 673
Measuring the Elastic Properties of Thin Polymer Films with the Atomic Force Microscope
Domke, J., & Radmacher, M. (1998) · Langmuir · doi:10.1021/la9713006 · Cited by 636
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 635
Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells
Mahaffy, R. E., Shih, C. K., MacKintosh, F. C., & Käs, J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.880 · Cited by 509
Thin Films Stresses and Mechanical Properties VI
Gerberich, W. W., Gao, H. J., Sundgren, J. ‐., & Baker, S. P. (1996) · Cited by 508
Review: Hydrogels for cell immobilization
Jen, A. C., Wake, M. C., & Mikos, A. G. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<357::aid-bit2>3.0.co;2-k · Cited by 484
Nanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Mechanical properties of the human achilles tendon
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00089-9 · Cited by 466
Elastic modulus measurements of human liver and correlation with pathology
Yeh, W.-C., Li, P.-C., Jeng, Y.-M., Hsu, H.-C., Kuo, P.-L., Li, M.-L., Yang, P.-M., & Lee, P. H. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00489-1 · Cited by 458
Directed Movement of Vascular Smooth Muscle Cells on Gradient-Compliant Hydrogels
Wong, J. Y., Velasco, A., Rajagopalan, P., & Pham, Q. (2003) · Langmuir · doi:10.1021/la026403p · Cited by 455
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
In situ elasticity modulation with dynamic substrates to direct cell phenotype
Kloxin, A. M., Benton, J. A., & Anseth, K. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.025 · Cited by 408
Vascular Smooth Muscle Cell Durotaxis Depends on Substrate Stiffness Gradient Strength
Isenberg, B. C., DiMilla, P. A., Walker, M., Kim, S., & Wong, J. Y. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.06.021 · Cited by 403
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Cell adaptation to a physiologically relevant ECM mimic with different viscoelastic properties
Ghosh, K., Pan, Z., Guan, E., Ge, S., Liu, Y., Nakamura, T., Ren, X.-D., Rafailovich, M., & Clark, R. A. F. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.038 · Cited by 386
Elastic Modulus Determination of Normal and Glaucomatous Human Trabecular Meshwork
Last, J. A., Pan, T., Ding, Y., Reilly, C. M., Keller, K., Acott, T. S., Fautsch, M. P., Murphy, C. J., & Russell, P. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6342 · Cited by 386
Self-citationBrown, X. Q., Ookawa, K., & Wong, J. Y. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.009 · Cited by 372
Engler, A. J., Richert, L., Wong, J. Y., Picart, C., & Discher, D. E. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.179 · Cited by 370
Elastic energy storage in tendons: mechanical differences related to function and age
Shadwick, R. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1033 · Cited by 362
Nonlinear material properties of intact cornea and sclera
Woo, S. L., KOBAYASHI, A. S., Schlegel, W. A., & Lawrence, C. (1972) · Experimental Eye Research · doi:10.1016/0014-4835(72)90139-x · Cited by 345
Wong, J. Y., Leach, J. B., & Brown, X. Q. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.186 · Cited by 323
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
Young's modulus measurements of soft tissues with application to elasticity imaging
Chen, E. J., Novakofski, J., Jenkins, W. K., & O'Brien, W. D. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.484478 · Cited by 312
The elastic modulus of Matrigel™ as determined by atomic force microscopy
Soofi, S. S., Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.05.005 · Cited by 309
Self-citationRepositioning of cells by mechanotaxis on surfaces with micropatterned Young's modulus
Gray, D. S., Tien, J., & Chen, C. S. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10585 · Cited by 308
Close dependence of fibroblast proliferation on collagen scaffold matrix stiffness
Hadjipanayi, E., Mudera, V., & Brown, R. A. (2009) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.136 · Cited by 307
Measuring the elastic modulus of ex vivo small tissue samples
Samani, A., Bishop, J., Luginbuhl, C., & Plewes, D. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/310 · Cited by 295
Measurements and modelling of the compliance of human and porcine organs
Carter, F. J., Frank, T. G., Davies, P. J., McLean, D., & Cuschieri, A. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00048-2 · Cited by 278
Costa, K. D., & Yin, F. C. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835074 · Cited by 265
Studying the Mechanics of Cellular Processes by Atomic Force Microscopy
Radmacher, M. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(07)83015-9 · Cited by 263
Anisotropic constitutive equations and experimental tensile behavior of brain tissue
Velardi, F., Fraternali, F., & Angelillo, M. (2006) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-005-0007-9 · Cited by 258
Reassessment of brain elasticity for analysis of biomechanisms of hydrocephalus
Taylor, Z., & Miller, K. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.11.027 · Cited by 237
Regional elastic performance of the human cornea
Hjortdal, J. Ø. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 231
The mechanical properties of the human cervical spinal cordIn Vitro
Bilston, L. E., & Thibault, L. E. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02770996 · Cited by 224
Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.03.012 · Cited by 222
Self-citationThe mechanical properties of the rabbit and human cornea
Jue, B., & Maurice, D. M. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90135-1 · Cited by 222
An overview of the biophysical applications of atomic force microscopy
Santos, N. C., & Castanho, M. A. R. B. (2004) · Biophysical Chemistry · doi:10.1016/j.bpc.2003.09.001 · Cited by 221
Leach, J. B., Brown, X. Q., Jacot, J. G., DiMilla, P. A., & Wong, J. Y. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/003 · Cited by 211
Elastic properties of human aortas in relation to age and atherosclerosis: a structural model
Wuyts, F. L., Vanhuyse, V. J., Langewouters, G. J., Decraemer, W. F., Raman, E. R., & Buyle, S. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/10/002 · Cited by 207
Comparison of mechanical properties of keratoconus and normal corneas
Nash, I. S., Greene, P. S., & Foster, C. S. (1982) · Experimental Eye Research · doi:10.1016/0014-4835(82)90040-9 · Cited by 204
Measuring microelastic properties of stratum corneum
Yuan, Y., & Verma, R. (2006) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2005.12.013 · Cited by 191
Alcaraz, J., Xu, R., Mori, H., Nelson, C. M., Mroue, R., Spencer, V. A., Brownfield, D., Radisky, D. C., Bustamante, C., & Bissell, M. J. (2008) · The EMBO Journal · doi:10.1038/emboj.2008.206 · Cited by 186
Energetic Bottlenecks and Other Design Constraints in Avian Annual Cycles
Piersma, T. (2002) · Integrative and Comparative Biology · doi:10.1093/icb/42.1.51 · Cited by 183
Determination of the Modulus of Elasticity of the Human Cornea
Elsheikh, A., Wang, D., & Pye, D. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20071001-11 · Cited by 179
Review: Hydrogels for cell immobilization
Jen, A. C., Wake, M. C., & Mikos, A. G. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<357::aid-bit2>3.3.co;2-f · Cited by 177
Zheng, Y. P., Choi, Y. K. C., Wong, K., Chan, S., & Mak, A. F. T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00163-5 · Cited by 171
Mechanical Properties of Dura Mater from the Rat Brain and Spinal Cord
Maikos, J. T., Elias, R. A. I., & Shreiber, D. I. (2008) · Journal of Neurotrauma · doi:10.1089/neu.2007.0348 · Cited by 166
Effects of long-term exercise on the biomechanical properties of the Achilles tendon of guinea fowl
Buchanan, C. I., & Marsh, R. L. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.164 · Cited by 165
Subramanian, A., & Lin, H. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30489 · Cited by 164
Clifford, C. A., & Seah, M. P. (2005) · Applied Surface Science · doi:10.1016/j.apsusc.2005.08.090 · Cited by 163
A transmission electron microscopy study of low-temperature reaction at the Co-Si interface
Ruterana, P., Houdy, P., & Boher, P. M. (1990) · Journal of Applied Physics · doi:10.1063/1.346741 · Cited by 147
Strain-rate dependent material properties of the porcine and human kidney capsule
Snedeker, J. G., Niederer, P. F., Schmidlin, F. R., Farshad, M., Demetropoulos, C. K., Lee, J.-H., & Yang, K. H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.036 · Cited by 147
A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue
Han, L., Noble, J. A., & Burcher, M. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00776-7 · Cited by 146
Semler, E. J., Ranucci, C. S., & Moghe, P. V. (2000) · Biotechnology and Bioengineering · doi:10.1002/1097-0290(20000820)69:4<359::aid-bit2>3.0.co;2-q · Cited by 143
Christensen, M. S., Hargens, C. W., Nacht, S., & Gans, E. H. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507500 · Cited by 143
Downs, J. C., Suh, J.-K. F., Thomas, K. A., Bellezza, A. J., Burgoyne, C. F., & Hart, R. T. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1536930 · Cited by 140
Viscoelastic properties of pig kidney in shear, experimental results and modelling
Nasseri, S., Bilston, L. E., & Phan-Thien, N. (2002) · Rheologica Acta · doi:10.1007/s003970200017 · Cited by 140
Vogel, H. G. (1978) · Connective Tissue Research · doi:10.3109/03008207809152626 · Cited by 133
The mechanical properties of the skin epidermis in relation to targeted gene and drug delivery
Kendall, M. A. F., Chong, Y.-F., & Cock, A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.006 · Cited by 132
Farrar, D. J., Green, H. D., Bond, M. G., et al. (1978) · Circulation Research · doi:10.1161/01.res.43.1.52 · Cited by 128
Reddy, G. K. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.04.002 · Cited by 126
Chou, S.-Y., Cheng, C., & LeDuc, P. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.037 · Cited by 115
Assessment of the epithelium's contribution to corneal biomechanics
Elsheikh, A., Alhasso, D., & Rama, P. (2007) · Experimental Eye Research · doi:10.1016/j.exer.2007.12.002 · Cited by 107
Modulus-dependent macrophage adhesion and behavior
Irwin, E. F., Saha, K., Rosenbluth, M., Gamble, L. J., Castner, D. G., & Healy, K. E. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208786052407 · Cited by 105
Probing mechanical properties of fully hydrated gels and biological tissues
Constantinides, G., Kalcioglu, Z. I., McFarland, M., Smith, J. F., & Vliet, K. J. V. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.015 · Cited by 99
MATSUMOTΟ, T., Abe, H., OHASHI, T., Kato, Y., & Sato, M. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/304 · Cited by 96
Bowen, W. R., Lovitt, R. W., & Wright, C. J. (2000) · Biotechnology Letters · doi:10.1023/a:1005604028444 · Cited by 92
Nanoindentation of histological specimens: Mapping the elastic properties of soft tissues
Akhtar, R., Schwarzer, N., Sherratt, M. J., Watson, R. E. B., Graham, H. K., Trafford, A. W., Mummery, P., & Derby, B. (2009) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2009.0130 · Cited by 89
Jacot, J. G., Dianis, S. W., Schnall, J., & Wong, J. Y. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30812 · Cited by 85
McKee, C. T., Wood, J. A., Shah, N. M., Fischer, M. E., Reilly, C. M., Murphy, C. J., & Russell, P. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.071 · Cited by 81
Self-citationDe Novo Design of Saccharide−Peptide Hydrogels as Synthetic Scaffolds for Tailored Cell Responses
Liao, S. W., Yu, T., & Guan, Z. (2009) · Journal of the American Chemical Society · doi:10.1021/ja907097t · Cited by 79
In Vivo Mechanical Behavior of Intra-abdominal Organs
Tay, B. K., Kim, J., & Srinivasan, M. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879474 · Cited by 78
Dynamic cell behavior on synthetic hydrogels with different charge densities
Chen, Y. M., Ogawa, R., Kakugo, A., Osada, Y., & Gong, J. P. (2009) · Soft Matter · doi:10.1039/b818586g · Cited by 69
Claridge, M., Bate, G. R., Hoskins, P. R., Adam, D. J., Bradbury, A. W., & Wilmink, A. B. M. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.12.030 · Cited by 61
Leung, S., Zheng, Y., Choi, C. Y. K., Mak, S. S. S., Chiu, S. K. W., Zee, B. C.-Y., & Mak, A. F. T. (2002) · Cancer · doi:10.1002/cncr.10700 · Cited by 59
Piezoelectric and mechanical properties in bovine cornea
Jayasuriya, A. C., Scheinbeim, J. I., Lubkin, V., Bennett, G., & Kramer, P. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10536 · Cited by 59
Moussallem, M. D., Olenych, S. G., Scott, S. L., Keller, T. C. S., & Schlenoff, J. B. (2009) · Biomacromolecules · doi:10.1021/bm9007309 · Cited by 57
Mechanical properties of rat thoracic and abdominal aortas
Assoul, N., Flaud, P., Chaouat, M., Letourneur, D., & Bataille, I. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.04.017 · Cited by 51
Asejczyk-Widlicka, M., Śródka, D. W., Kasprzak, H. T., & Pierscionek, B. K. (2006) · Eye · doi:10.1038/sj.eye.6702464 · Cited by 49
Aortic Walls in Atherosclerotic Rabbits—Mechanical Study
Hayashi, K., Ide, K., & MATSUMOTΟ, T. (1994) · Journal of Biomechanical Engineering · doi:10.1115/1.2895732 · Cited by 46
The effects of ovariectomy on the mechanical properties of skin in rats
Özyazgan, İ., Liman, N., Dursun, N., & Güneş, I. (2002) · Maturitas · doi:10.1016/s0378-5122(02)00181-0 · Cited by 41
Experimental measurement and modeling analysis on mechanical properties of tensor tympani tendon
Cheng, T., & Gan, R. Z. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.04.005 · Cited by 38
Amini, R., & Barocas, V. H. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2890 · Cited by 35
Lundkvist, A. S., Lilleodden, E. T., Siekhaus, W. J., Kinney, J. H., Pruitt, L. A., & Balooch, M. (1996) · MRS Proceedings · doi:10.1557/proc-436-353 · Cited by 34
Saxena, T. K., Gilbert, J. L., & Hasenwinkel, J. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32178 · Cited by 29
The elastic modulus of central and perilimbal bovine cornea.
Reichel, E., Miller, D., Blanco, E., & Mastanduno, R. (1989) · PubMed · Cited by 29
Development of a mechanical testing assay for fibrotic murine liver
Barnes, S. L., Lyshchik, A. P., Washington, M. K., Gore, J. C., & Miga, M. I. (2007) · Medical Physics · doi:10.1118/1.2795665 · Cited by 28
In situ estimation of tendon material properties: Differences between muscles of the feline hindlimb
Cui, L., Maas, H., Perreault, E. J., & Sandercock, T. G. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.01.022 · Cited by 24
Imura, T., Yamamoto, K., Satoh, T., Mikami, T., & Yasuda, H. (1988) · Atherosclerosis · doi:10.1016/0021-9150(88)90036-6 · Cited by 19
The influence of surface morphology and rigidity of the substrata on cell motility
Chen, C.-C., Hsieh, P. C.-H., Wang, G.-M., Chen, W., & Yeh, M. (2009) · Materials Letters · doi:10.1016/j.matlet.2009.05.073 · Cited by 19
Effect of material properties of the eyeball coat on optical image stability
Srodka, W., & Pierscionek, B. K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2975844 · Cited by 12
Cited by
Molecular Mechanisms of Stress-Responsive Changes in Collagen and Elastin Networks in Skin
Aziz, J., Shezali, H., Radzi, Z., Yahya, N. A., Abu Kassim, N. H., Czernuszka, J., & Rahman, M. T. (2016) · Skin Pharmacology and Physiology · doi:10.1159/000447017 · Cited by 7,323
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Cosgrove, D. J. (2016) · Journal of Experimental Botany · doi:10.1093/jxb/erv511 · Cited by 611
Metadata
- Authors
- McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J.
- Venue
- Tissue Engineering Part B: Reviews
- Publisher
- SAGE Publications
- Published
- 2011-06
- Volume
- 17
- Issue
- 3
- Pages
- 155-164
- ISSN
- 1937-3368 (ISSN-L)
- 1937-3376
- OpenAlex
- W2039692967
- Cited by
- 708
- References
- 124
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.