Evaluating fMRI preprocessing pipelines
The DOI matches its Crossref record, with a small difference in title or year; 142 of the 144 references it cites were found in a registry or an index.
Abstract
This article reviews the evaluation and optimization of the preprocessing steps for blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). This technique indirectly measures changes in local neuronal firing rates by measuring associated changes in deoxy-hemoglobin concentrations in nearby blood vessels. Based on the existing literature, it is impossible to make conclusive statements about the optimal algorithm and software implementations for any single preprocessing step, let alone entire pipelines. The author believes that the present focus on the technological testing of preprocessing steps should be balanced by approaches that test the pipeline. This should include all interactions measured using metrics that are closely linked to research and diagnostic questions addressed at the end of the processing pipeline. The goal is to avoid single expedient or default pipelines by developing a framework capable of potentially testing thousands of possible pipeline implementations per dataset. To achieve this goal, researchers depend on recent developments in software tools for managing neuroimaging workflows.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some physiological noises, such as cardiac and respiratory rates, can alias into the low-frequency domain of functional MRI signals (Strother, 2006;Murphy et al., 2009).”
From Identifying major depression using whole-brain functional connectivity: a multivariate pattern analysis (2012) · cites this paper as Strother, 2006
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 11×
“There are many algorithms, such as BFC, that are incorporated into tissue segmentation and classification packages because bias correction is a necessary preprocessing step for (and interacts with) tissue classification [84].”
MethodInfluentialJenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888 · cited 5×
“There is a large body of literature on retrospective correction of rigid-body head motion in fMRI, with each of the major packages having implemented their own approach: AFNI, [24]; FSL, motion correction by FMRIB’s linear registration tool (MCFLIRT), [25]; SPM, [26], [27]; and BrainVoyager (the approach used seems to…”
BackgroundMethodInfluentialAFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913 · cited 6×
“There is a large body of literature on retrospective correction of rigid-body head motion in fMRI, with each of the major packages having implemented their own approach: AFNI, [24]; FSL, motion correction by FMRIB’s linear registration tool (MCFLIRT), [25]; SPM, [26], [27]; and BrainVoyager (the approach used seems to…”
BackgroundInfluentialCortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910 · cited 2×
“Segonne compared the hybrid algorithm with BET, BSE, Freesurfer’s strip skull [76], and Hahn and Peitgen’s [77] watershed algorithm and found that it performed best across a variety of metrics with few misclassified voxels.”
MethodFast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496 · cited 4×
“IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE MARCH/APRIL 2006 35 demonstrates that McStrip consistently outperformed SPM2’s brain extraction algorithm [72], FSL’s Brain Extraction Tool (BET) [73], and the Brain Surface Extractor (BSE) [74].”
MethodInfluentialVoxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676 · cited 1×
“IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE MARCH/APRIL 2006 35 demonstrates that McStrip consistently outperformed SPM2’s brain extraction algorithm [72], FSL’s Brain Extraction Tool (BET) [73], and the Brain Surface Extractor (BSE) [74].”
MethodZhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982 · cited 2×
“As a result, there are algorithms for correcting intensity nonuniformities that are part of tissue segmentation and classification packages that have not been compared, even across the major software packages, e.g., from within FMRIB’s automated segmentation tool (FAST) [85].”
MethodA nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“[82] in which two locally adaptive algorithms provided the most reliable correction: nonparametric, nonuniform intensity normalization (N3) [83], and bias field corrector (BFC) [74].”
MethodSpatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028 · cited 7×
“There is a large body of literature on retrospective correction of rigid-body head motion in fMRI, with each of the major packages having implemented their own approach: AFNI, [24]; FSL, motion correction by FMRIB’s linear registration tool (MCFLIRT), [25]; SPM, [26], [27]; and BrainVoyager (the approach used seems to…”
MethodInfluentialMovement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774 · cited 1×
“[52] suggested that this is due to spin-history effects, and Woods et al.”
BackgroundTemporal Autocorrelation in Univariate Linear Modeling of FMRI Data
Woolrich, M. W., Ripley, B. D., Brady, M., & Smith, S. M. (2001) · NeuroImage · doi:10.1006/nimg.2001.0931 · Cited by 2,852 · cited 1×
“Low-pass filtering, or temporal smoothing, applied to individual voxel time series has been found to degrade signal detection power in block designs [118] and degrades parameter estimation efficiency even more for single-event designs [134].”
MethodProbabilistic Independent Component Analysis for Functional Magnetic Resonance Imaging
Beckmann, C. F., & Smith, S. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.822821 · Cited by 2,715 · cited 5×
“The image is reproduced courtesy of Beckmann and Smith [20] from IEEE Transactions on Image Processing which contains further details.”
MethodInfluentialImage matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
A hybrid approach to the skull stripping problem in MRI
Ségonne, F., Dale, A. M., Busa, E., Glessner, M., Salat, D., Hahn, H. K., & Fischl, B. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.032 · Cited by 2,212
Assessing the significance of focal activations using their spatial extent
Friston, K. J., Worsley, K. J., Frackowiak, R. S. J., Mazziotta, J. C., & Evans, A. C. (1994) · Human Brain Mapping · doi:10.1002/hbm.460010306 · Cited by 1,907
Nonlinear spatial normalization using basis functions
Ashburner, J., & Friston, K. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:4<254::aid-hbm4>3.0.co;2-g · Cited by 1,884 · cited 1×
“, warps) with hundreds of degrees of freedom (SPM, [91]; AIR, [90]), and 3) highly flexible warps with thousands of degrees of freedom [92]–[99].”
BackgroundSelf-citationAutomated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707 · cited 2×
“In addition, the automatic image registration (AIR) package developed by Roger Woods is widely used [28]–[30] (http://bishopw.”
MethodCorrection for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421 · cited 1×
“The first and most common method used involves measuring the magnetic field inhomogeneities to create a field map for the fixed component, which is used to modify the acquired fMRI images [46], [47].”
MethodSurvey: interpolation methods in medical image processing
Lehmann, T. M., Gonner, C., & Spitzer, K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816070 · Cited by 1,340 · cited 1×
“Whether one of these schemes or some other is used, most interpolation approaches leave residual errors in the realigned volumes [28], [43] (trilinear interpolation leaves much larger residual errors than sinc-related and Bspline schemes [41], [42]).”
BackgroundThe problem of functional localization in the human brain
Brett, M., Johnsrude, I. S., & Owen, A. M. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn756 · Cited by 1,119 · cited 1×
“[100], with additional details and web links at http:// www.”
BackgroundModeling Geometric Deformations in EPI Time Series
Andersson, J. L. R., Hutton, C., Ashburner, J., Turner, R., & Friston, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0746 · Cited by 1,011
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 994
Automatic 3‐D model‐based neuroanatomical segmentation
Collins, D. L., Holmes, C. J., Peters, T. M., & Evans, A. C. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030304 · Cited by 974
The problem of functional localization in the human brain
Morgan, T. (2002) · Cited by 965
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955 · cited 2×
“Provided the TR is fast enough to capture the unaliased cardiac effects (i.e., 500 ms), these noise sources may all be seen in the power spectrum and can be removed by notch filtering [59] or the more sophisticated multitaper techniques of Mitra and Pesaran [60].”
MethodMagnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950 · cited 8×
“There are many algorithms, such as BFC, that are incorporated into tissue segmentation and classification packages because bias correction is a necessary preprocessing step for (and interacts with) tissue classification [84].”
MethodInfluentialMultimodal Image Coregistration and Partitioning—A Unified Framework
Ashburner, J., & Friston, K. (1997) · NeuroImage · doi:10.1006/nimg.1997.0290 · Cited by 927
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1998) · Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) · Cited by 898
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884 · cited 1×
“It has been clear for some time that intensity-based cost functions outperform landmark and fiducial-marker-based approaches [35], [36].”
BackgroundImage Distortion Correction in fMRI: A Quantitative Evaluation
Hutton, C., Bork, A., Josephs, O., Deichmann, R., Ashburner, J., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.1054 · Cited by 681 · cited 1×
“Attempts have also been made to estimate and use dynamic field maps collected at each time point [48].”
MethodWise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664 · cited 1×
“The exact causes of this noise structure remain unclear, although it is probably some mixture of scanner drift [137], aliased cardiac physiological noise, and respiratory physiological noise, such as that due to resting fluctuations in arterial CO2 [138].”
BackgroundReal-time 3D image registration for functional MRI
Cox, R. W., & Jesmanowicz, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1014::aid-mrm4>3.0.co;2-f · Cited by 663 · cited 2×
“The ideal scheme for performing these interpolations on band-limited images, without introducing artifacts, is Fourier interpolation [24], [39].”
BackgroundMethodChristensen, G. E., & Johnson, H. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932742 · Cited by 636
Physiological noise in oxygenation‐sensitive magnetic resonance imaging
Krüger, G., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1240 · Cited by 629 · cited 4×
“Kruger and Glover [58] have demonstrated that at 3.0 T, these physiological noise sources are greater than those from system and thermal noise and significantly greater in gray matter than white matter.”
BackgroundInfluentialExperimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523 · cited 1×
“5 T fields in homogeneous brain tissue [12].”
BackgroundRetrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475 · cited 3×
“Physiological corrections were performed using externally monitored respiration and cardiac signals [66],”
BackgroundMethodSpatially independent activity patterns in functional MRI data during the Stroop color-naming task
McKeown, M. J., Jung, T.-P., Makeig, S., Brown, G., Kindermann, S. S., Lee, T.-W., & Sejnowski, T. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.803 · Cited by 461 · cited 11×
“One of the options with PICA is to filter the dataset by removing user-identified PICA components.”
MethodInfluentialBullmore, E. T., Brammer, M. J., Rabe-Hesketh, S., Curtis, V. A., Morris, R. G., Williams, S. C. R., Sharma, T., & McGuire, P. K. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:1<38::aid-hbm4>3.0.co;2-q · Cited by 455 · cited 2×
“[53], although a more robust strategy would be to always evaluate SPI differences with and without residual motion regression.”
BackgroundVolumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438
Friston, K. J., Josephs, O., Zarahn, E., Holmes, A. P., Rouquette, S., & Poline, J.-B. (2000) · NeuroImage · doi:10.1006/nimg.2000.0609 · Cited by 431 · cited 5×
“A number of simple approaches, such as plotting the time series of slice means, are discussed in [6], and many of these are available as supplemental software tools for the major packages, such as in the SPM2 diagnosis toolbox [17].”
MethodInfluentialAverage Brain Models: A Convergence Study
Guimond, A., Meunier, J., & Thirion, J.-P. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0815 · Cited by 426
Consistent landmark and intensity-based image registration
Johnson, H. J., & Christensen, G. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009381 · Cited by 399 · cited 1×
“As a possible means of addressing this surprising result, a number of groups are exploring the use of intensitybased algorithms with additional anatomical constraints, such as major sulcal landmarks or automatically generated features [106]–[108].”
BackgroundFast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397 · cited 2×
“In addition, the MSV approach has been combined with a concurrent iterative image reconstruction incorporating correction for field-inhomogeneities [47].”
MethodWhat is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353 · cited 2×
“, the Geman-McClure M-estimator) reduce but do not eliminate the influence of task activation on estimated motion variables [37].”
BackgroundAnimal: Validation and Applications of Nonlinear Registration-Based Segmentation
Collins, D. L., & Evans, A. C. (1997) · International Journal of Pattern Recognition and Artificial Intelligence · doi:10.1142/s0218001497000597 · Cited by 351
Becerra, L. R., Breiter, H. C., Stojanovic, M., Fishman, S., Edwards, A., Comite, A. R., Gonzalez, R. G., & Borsook, D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5<1044::aid-mrm25>3.0.co;2-m · Cited by 326
Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325 · cited 1×
“However, this advantage is somewhat reduced by a higher physiological noise fraction, greater artifacts at air-tissue boundaries, and reduced decay times [13], i.”
BackgroundInvestigation of Low Frequency Drift in fMRI Signal
Smith, A. M., Lewis, B. K., Ruttimann, U. E., Ye, F. Q., Sinnwell, T. M., Yang, Y., Duyn, J. H., & Frank, J. A. (1999) · NeuroImage · doi:10.1006/nimg.1999.0435 · Cited by 313 · cited 1×
“The exact causes of this noise structure remain unclear, although it is probably some mixture of scanner drift [137], aliased cardiac physiological noise, and respiratory physiological noise, such as that due to resting fluctuations in arterial CO2 [138].”
BackgroundThe LONI Pipeline Processing Environment
Rex, D. E., Ma, J. Q., & Toga, A. W. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00185-x · Cited by 310 · cited 1×
“To achieve this goal, we are depending on recent developments in software tools for managing neuroimaging workflows [143]–[145].”
MethodMotion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308 · cited 1×
“Freire and colleagues have demonstrated that the standard retrospective alignment algorithms may even create spurious activations, particularly with least squares cost functions [38].”
BackgroundA Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR Images
Hajnal, J. V., Saeed, N., Soar, E. J., Oatridge, A., Young, I. R., & Bydder, G. M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199503000-00022 · Cited by 304 · cited 1×
“In order to gain speed, a truncated sinc is often used that needs values from only the local neighborhood of the new voxel location [40].”
BackgroundReduction of physiological fluctuations in fMRI using digital filters
Biswal, B., Deyoe, E. A., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350114 · Cited by 302 · cited 1×
“, <500 ms), these noise sources may all be seen in the power spectrum and can be removed by notch filtering [59] or the more sophisticated multitaper techniques of Mitra and Pesaran [60].”
MethodNoise Reduction in BOLD-Based fMRI Using Component Analysis
Thomas, C. G., Harshman, R. A., & Menon, R. S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1200 · Cited by 280 · cited 2×
“A preliminary investigation of denoising using PCA and ICA has been performed by [21].”
MethodDenoising Functional MR Images: A Comparison of Wavelet Denoising and Gaussian Smoothing
Wink, A. M., & Roerdink, J. B. J. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.824234 · Cited by 271 · cited 3×
“Wink and Roerdink [125] compared spatial wavelet denoising with Gaussian smoothing and reported that, “wavelet denoising methods that introduce relatively little smoothness are generally preferable over Gaussian smoothing for denoising fMRI time series.”
BackgroundInfluentialGelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
Wavelets and functional magnetic resonance imaging of the human brain
Bullmore, E., Fadili, J., Maxim, V., Şendur, L., Whitcher, B., Suckling, J., Brammer, & Breakspear, M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.012 · Cited by 261 · cited 2×
“However, if using nonparametric tests that control for temporal autocorrelation [133], it is unclear if either prewhitening or precoloring should be used.”
BackgroundMethodROC Analysis of Statistical Methods Used in Functional MRI: Individual Subjects
Skudlarski, P., Constable, R. T., & Gore, J. C. (1999) · NeuroImage · doi:10.1006/nimg.1999.0402 · Cited by 260 · cited 7×
“Low-pass filtering, or temporal smoothing, applied to individual voxel time series has been found to degrade signal detection power in block designs [118] and degrades parameter estimation efficiency even more for single-event designs [134].”
BackgroundMethodInfluentialStrother, S. C., Anderson, J., Hansen, L. K., Kjems, U., Kustra, R., Sidtis, J., Frutiger, S., Muley, S., LaConte, S., & Rottenberg, D. (2002) · NeuroImage · doi:10.1006/nimg.2001.1034 · Cited by 248 · cited 1×
“We have made a start on such a testing program using the resampling framework reported in [1], [11], [121], [146], [147].”
MethodSelf-citationThe Inferential Impact of Global Signal Covariates in Functional Neuroimaging Analyses
Aguirre, G. K., Zarahn, E., & D'Esposito, M. (1998) · NeuroImage · doi:10.1006/nimg.1998.0367 · Cited by 225 · cited 2×
“These intensity normalization techniques interact with the temporal and spatial filtering approaches because 1) to the extent that global variations are low- or high-temporal frequency phenomena, they will tend to be removed by low- and high-pass temporal filters, and 2) spatial smoothing tends to increase the correla…”
BackgroundAn Evaluation of the Use of Magnetic Field Maps to Undistort Echo-Planar Images
Cusack, R., Brett, M., & Osswald, K. (2003) · NeuroImage · doi:10.1006/nimg.2002.1281 · Cited by 219 · cited 8×
“Transformations from Registration II are then applied to individual SPIs so that they may be displayed on their subjects’ MRIs, and by combining transformations from Registration II and III, SPIs are resampled into a common space to perform a higher-level group analysis.”
MethodInfluentialStrother, S., Anderson, J., Frutiger, S., Muley, S., Rottenberg, D., Kjems, U., & Hansen, L. K. (2000) · NeuroImage · doi:10.1016/s1053-8119(00)91523-4 · Cited by 217
Self-citationPfeuffer, J., Van de Moortele, P., Ugurbil, K., Hu, X., & Glover, G. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10065 · Cited by 216 · cited 1×
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundPostacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI
Menon, R. S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10041 · Cited by 214 · cited 1×
“There has also been a recent focus on using complex-valued fMRI time series to improve activation detection [2]–[4] and remove vascular artifacts [5].”
BackgroundSpherical navigator echoes for full 3D rigid body motion measurement in MRI
Welch, E. B., Manduca, A., Grimm, R. C., Ward, H. A., & Jack Jr., C. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10012 · Cited by 212 · cited 1×
“Other Issues There are a number of other trends at this preprocessing stage: 1) using the pulse sequence to monitor rigid-body motion [54], 2) developing monitoring techniques as summary measures for QC [55] or to acquire the rigid-body transformations through external monitoring [56], and 3) volume-by-volume motion c…”
BackgroundSurface-based approaches to spatial localization and registration in primate cerebral cortex
Van Essen, D. C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.024 · Cited by 204 · cited 1×
“Recent developments include the use of structural landmarks to constrain warps across cortical surface representations on a sphere or a flattened representation [110], [111].”
BackgroundRetrospective evaluation of intersubject brain registration
Hellier, P., Barillot, C., Corouge, I., Gibaud, B., Le Goualher, G., Collins, D. L., Evans, A., Malandain, G., Ayache, N., Christensen, G. E., et al. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816961 · Cited by 200 · cited 1×
“[105] have shown that global metrics assessing the registration of structural MRIs improve with increasing degrees of freedom, but local measures of the match between cortical sulci are not significantly different between simple, six-parameter, rigid-body transformations and highly flexible warps.”
BackgroundRegional Spatial Normalization: Toward an Optimal Target
Kochunov, P., Lancaster, J. L., Thompson, P., Woods, R., Mazziotta, J., Hardies, J., & Fox, P. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200109000-00023 · Cited by 196
An optimized method for estimating intracranial volume from magnetic resonance images
Eritaia, J., Wood, S. J., Stuart, G. W., Bridle, N., Dudgeon, P., Maruff, P. T., Velakoulis, D., & Pantelis, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<973::aid-mrm21>3.0.co;2-h · Cited by 196
Motion detection and correction in functional MR imaging
Jiang, A., Kennedy, D. N., Baker, J. R., Weisskoff, R. M., Tootell, R. B. H., Woods, R. P., Benson, R. R., Kwong, K. K., Brady, T. J., Rosen, B. R., et al. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030306 · Cited by 195
Mitra, P. P., Ogawa, S., Hu, X., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370407 · Cited by 185
Moeller, J. R., & Strother, S. C. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.47 · Cited by 183 · cited 8×
“He specializes in data analysis and optimization of positron emission tomography (PET) and fMRI neuroimaging techniques for both research and clinical applications.”
BackgroundInfluentialSelf-citationRemoval of Confounding Effects of Global Signal in Functional MRI Analyses
Desjardins, A. E., Kiehl, K. A., & Liddle, P. F. (2001) · NeuroImage · doi:10.1006/nimg.2000.0719 · Cited by 182 · cited 1×
“compared five approaches: grand-mean session scaling (GMS), proportional scaling (PS), ANCOVA, iterative masking of activation areas [129], and orthogonalization of the global estimate [131].”
Addendum: B-spline interpolation in medical image processing
Lehmann, T. M., Gonner, C., & Spitzer, K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932749 · Cited by 175 · cited 1×
“Whether one of these schemes or some other is used, most interpolation approaches leave residual errors in the realigned volumes [28], [43] (trilinear interpolation leaves much larger residual errors than sinc-related and Bspline schemes [41], [42]).”
BackgroundThe Skull Stripping Problem in MRI Solved by a Single 3D Watershed Transform
Hahn, H. K., & Peitgen, H. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_14 · Cited by 172 · cited 1×
“Segonne compared the hybrid algorithm with BET, BSE, Freesurfer’s strip skull [76], and Hahn and Peitgen’s [77] watershed algorithm and found that it performed best across a variety of metrics with few misclassified voxels.”
MethodArnold, J. B., Liow, J.-S., Schaper, K. A., Stern, J. J., Sled, J. G., Shattuck, D. W., Worth, A. J., Cohen, M. S., Leahy, R. M., Mazziotta, J. C., et al. (2001) · NeuroImage · doi:10.1006/nimg.2001.0756 · Cited by 172 · cited 1×
“[82] in which two locally adaptive algorithms provided the most reliable correction: nonparametric, nonuniform intensity normalization (N3) [83], and bias field corrector (BFC) [74].”
MethodQuantifying Head Motion Associated with Motor Tasks Used in fMRI
Seto, E., Sela, G., McIlroy, W. E., Black, S. E., Staines, W. R., Bronskill, M. J., McIntosh, A. R., & Graham, S. J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0829 · Cited by 170 · cited 1×
“[23] have demonstrated that a subject’s demographic group (i.”
BackgroundFunctional Magnetic Resonance Imaging
Zhong, J., & Bavelier, D. (2005) · Neurology · doi:10.1212/01.wnl.0000157470.95296.1c · Cited by 163
Diagnosis and exploration of massively univariate neuroimaging models
Luo, W., & Nichols, T. E. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00149-6 · Cited by 159 · cited 1×
“A number of simple approaches, such as plotting the time series of slice means, are discussed in [6], and many of these are available as supplemental software tools for the major packages, such as in the SPM2 diagnosis toolbox [17].”
MethodA Robust Method for Extraction and Automatic Segmentation of Brain Images
Kovacevic, N., Lobaugh, N. J., Bronskill, M. J., Levine, B., Feinstein, A., & Black, S. E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1221 · Cited by 158 · cited 1×
“[78] developed an algorithm with the goal of extracting the brain and surrounding cerebrospinal fluid (CSF) in the subarachnoid space for studying longitudinal structural changes.”
MethodA New Statistical Approach to Detecting Significant Activation in Functional MRI
Marchini, J., & Ripley, B. D. (2000) · NeuroImage · doi:10.1006/nimg.2000.0628 · Cited by 155 · cited 2×
“Finally, the FSL package has adopted a quite different nonlinear trend removal approach using a running lines smoother [142].”
BackgroundMethodStrother, S. C., Conte, S. L., Hansen, L. K., Anderson, J., Zhang, J., Pulapura, S. K., & Rottenberg, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.022 · Cited by 152 · cited 10×
“At the other end of the processing pipeline, the choice of data analysis approach may strongly interact with the preprocessing parameter choices, and these interactions are gradually being studied [1], [9]–[11].”
InfluentialSelf-citationLe, T. H., & Hu, X. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350305 · Cited by 146 · cited 1×
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundIndependent component analysis of fMRI data in the complex domain
Calhoun, V. D., Adalı, T., Pearlson, G. D., van Zijl, P. C. M., & Pekar, J. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10202 · Cited by 146 · cited 1×
“There has also been a recent focus on using complex-valued fMRI time series to improve activation detection [2]–[4] and remove vascular artifacts [5].”
BackgroundImproved image registration by using fourier interpolation
Eddyy, W. F., Fitzgerald, M., & Noll, D. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360615 · Cited by 142 · cited 1×
“The ideal scheme for performing these interpolations on band-limited images, without introducing artifacts, is Fourier interpolation [24], [39].”
BackgroundFunctional MRI statistical software packages: A comparative analysis
Gold, S., Christian, B., Arndt, S., Zeien, G., Cizadlo, T., Johnson, D. L., Flaum, M., & Andreasen, N. C. (1998) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1998)6:2<73::aid-hbm1>3.0.co;2-h · Cited by 139 · cited 1×
“Many fMRI studies in the literature are based on an analysis using the general linear model (GLM) within the statistical parametric mapping (SPM) software package [14] (Table 1).”
MethodCharacterization and Correction of Interpolation Effects in the Realignment of fMRI Time Series
Grootoonk, S., Hutton, C., Ashburner, J., Howseman, A., Josephs, O., Rees, G. E., Friston, K. J., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.1999.0515 · Cited by 138 · cited 3×
“[28] noted that “motion-correlated artifact is commonly the greatest source of global variance in the motion-corrected dataset” and suggested that these effects are most likely due to residual interpolation effects (see also [43]).”
BackgroundComparison of Detrending Methods for Optimal fMRI Preprocessing
Tanabe, J., Miller, D. E., Tregellas, J. R., Freedman, R., & Meyer, F. G. (2002) · NeuroImage · doi:10.1006/nimg.2002.1053 · Cited by 136 · cited 1×
“[141] tested five trend removal techniques and found that a cubic spline produced the largest number of significant voxels among linear, quadratic, cubic, and wavelet detrending approaches.”
Spatially filtering functional magnetic resonance imaging data
Lowe, M. J., & Sorenson, J. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370514 · Cited by 135 · cited 1×
“Spatial Filtering The importance of measuring and manipulating the spatial correlations of functional neuroimages has been extensively studied [115]–[117], and the dramatic impact a little spatial smoothing may have on signal detection power in fMRI should be carefully considered when specifying a preprocessing pipeli…”
BackgroundCorrection of differential intensity inhomogeneity in longitudinal MR images
Lewis, E. B., & Fox, N. C. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.030 · Cited by 134 · cited 1×
“A variety of algorithms have been developed for correcting intensity nonuniformities and new approaches are being continually developed [79], with an emphasis on correction in the presence of atrophy from dementia and aging [80] and longitudinal studies of structural changes over time [81].”
BackgroundThe Evaluation of Preprocessing Choices in Single-Subject BOLD fMRI Using NPAIRS Performance Metrics
LaConte, S. M., Anderson, J., Muley, S., Ashe, J., Frutiger, S. A., Rehm, K., Hansen, L. K., Yacoub, E. S., Hu, X. P., Rottenberg, D. A., et al. (2002) · NeuroImage · doi:10.1006/nimg.2002.1300 · Cited by 133 · cited 3×
“We have made a start on such a testing program using the resampling framework reported in [1], [11], [121], [146], [147].”
BackgroundMethodResultSelf-citationQuantitative comparison of four brain extraction algorithms
Boesen, K., Rehm, K., Schaper, K. A., Stoltzner, S. E., Woods, R. P., Eileen Luders, A., & Rottenberg, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.010 · Cited by 127
A meta-algorithm for brain extraction in MRI
Rex, D., Shattuck, D. W., Woods, R. P., Narr, K. L., Eileen Luders, A., Rehm, K., Stolzner, S. E., Rottenberg, D. A., & Toga, A. W. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.019 · Cited by 125
Coupling dense and landmark-based approaches for nonrigid registration
Hellier, P., & Barillot, C. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808365 · Cited by 122
Quantitative Comparisons of Image Registration Techniques Based on High-Resolution MRI of the Brain
Strother, S. C., Anderson, J. R., Xu, X., Liow, J., Bonar, D. C., & Rottenberg, D. A. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199411000-00021 · Cited by 121 · cited 2×
“Such QC bounds may be applied directly to the estimated rigid-body motion plots or to calculated mean-voxel or maximum-voxel displacement values [35].”
BackgroundMethodSelf-citationModeling both the magnitude and phase of complex-valued fMRI data
Rowe, D. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.034 · Cited by 121
Hierarchical estimation of a dense deformation field for 3-D robust registration
Hellier, P., Barillot, C., Memin, E., & Perez, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.925292 · Cited by 118
How to Estimate Global Activity Independent of Changes in Local Activity
Andersson, J. (1997) · NeuroImage · doi:10.1006/nimg.1997.0302 · Cited by 109 · cited 2×
“compared five approaches: grand-mean session scaling (GMS), proportional scaling (PS), ANCOVA, iterative masking of activation areas [129], and orthogonalization of the global estimate [131].”
BackgroundKjems, U., Hansen, L. K., Anderson, J., Frutiger, S. A., Muley, S., Sidtis, J. J., Rottenberg, D. A., & Strother, S. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.1033 · Cited by 106 · cited 1×
“We have made a start on such a testing program using the resampling framework reported in [1], [11], [121], [146], [147].”
MethodSelf-citationWoods, R. P. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00019-3 · Cited by 102 · cited 1×
“There have been several proposals for developing such optimal, group-specific templates [28], [101]–[104], but to date their use has not been compared with the standard MNI/ICBM population-based templates.”
MethodComparison of spatial normalization procedures and their impact on functional maps
Crivello, F., Schormann, T., Tzourio‐Mazoyer, N., Roland, P. E., Zilles, K., & Mazoyer, B. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10047 · Cited by 98 · cited 1×
“[113] also used PET and MRI scans with an affine and three warping algorithms: affine and the fifth-order polynomial in AIR 3.”
MethodSynthetic images by subspace transforms I. Principal components images and related filters
Sychra, J. J., Bandettini, P. A., Bhattacharya, N., & Lin, Q. (1994) · Medical Physics · doi:10.1118/1.597374 · Cited by 85 · cited 10×
“A variety of choices are available for the regressors: the raw rigid-body movement variables, the first few components of their PCA [28], or sine and cosine basis functions with a one-voxel cycle [43].”
MethodInfluentialSimulation of the Effects of Global Normalization Procedures in Functional MRI
Gavrilescu, M. C., Shaw, M. E., Stuart, G. W., Eckersley, P., Svalbe, I., & Egan, G. F. (2002) · NeuroImage · doi:10.1006/nimg.2002.1226 · Cited by 78 · cited 1×
“A variety of global normalization approaches have developed to model and control for this variation, originally in PET [128], [129] and, based on these, more recently in fMRI [130]–[132].”
BackgroundRehm, K., Schaper, K. A., Anderson, J., Woods, R. P., Stoltzner, S. E., & Rottenberg, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.011 · Cited by 77 · cited 1×
“[71] performed better than any individual algorithm, and this finding was echoed by Rex but by using a different consensus approach based on training datasets and somewhat different algorithms.”
MethodFiswidgets: A Graphical Computing Environment for Neuroimaging Analysis
Fissell, K., Tseytlin, E., Cunningham, D., Iyer, K., Carter, C. S., Schneider, W., & Cohen, J. D. (2003) · Neuroinformatics · doi:10.1385/ni:1:1:111 · Cited by 72
Enhanced Detection in Brain Activation Maps Using a Multifiltering Approach
Poline, J.-B., & Mazoyer, B. M. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.79 · Cited by 72 · cited 2×
“Spatial Filtering The importance of measuring and manipulating the spatial correlations of functional neuroimages has been extensively studied [115]–[117], and the dramatic impact a little spatial smoothing may have on signal detection power in fMRI should be carefully considered when specifying a preprocessing pipeli…”
BackgroundLeow, A., Yu, C. L., Lee, S. J., Huang, S.-C., Protas, H. D., Nicolson, R., Hayashi, K. M., Toga, A. W., & Thompson, P. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.022 · Cited by 72
IMPACT: Image‐based physiological artifacts estimation and correction technique for functional MRI
Chuang, K., & Chen, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1197 · Cited by 72 · cited 2×
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundMethodA quantitative comparison of motion detection algorithms in fMRI
Ardekani, B. A., Bachman, A. H., & Helpern, J. A. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00418-0 · Cited by 71
Retrospective coregistration of functional magnetic resonance imaging data using external monitoring
Tremblay, M., Tam, F., & Graham, S. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20319 · Cited by 65 · cited 1×
“Other Issues There are a number of other trends at this preprocessing stage: 1) using the pulse sequence to monitor rigid-body motion [54], 2) developing monitoring techniques as summary measures for QC [55] or to acquire the rigid-body transformations through external monitoring [56], and 3) volume-by-volume motion c…”
BackgroundDatabasing fMRI studies — towards a 'discovery science' of brain function
Horn, J. D. V., & Gazzaniga, M. S. (2002) · Nature reviews. Neuroscience · doi:10.1038/nrn788 · Cited by 64 · cited 1×
“This observation is supported by the fact that 67 of the 100 distributable, published datasets available from the fMRI Data Center [15] were originally analyzed using some version of SPM [16].”
BackgroundMRI intensity inhomogeneity correction by combining intensity and spatial information
Vovk, U., Pernu, F., & Likar, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/17/020 · Cited by 63 · cited 1×
“A variety of algorithms have been developed for correcting intensity nonuniformities and new approaches are being continually developed [79], with an emphasis on correction in the presence of atrophy from dementia and aging [80] and longitudinal studies of structural changes over time [81].”
BackgroundKjems, U., Strother, S. C., Anderson, J., Law, I. G., & Hansen, L. K. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.768840 · Cited by 56 · cited 2×
“, warps) with hundreds of degrees of freedom (SPM, [91]; AIR, [90]), and 3) highly flexible warps with thousands of degrees of freedom [92]–[99].”
BackgroundSelf-citationShaw, M. E., Strother, S. C., Gavrilescu, M. C., Podzebenko, K., Waites, A. B., Watson, J. D. G., Anderson, J., Jackson, G. D., & Egan, G. F. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00116-2 · Cited by 54 · cited 3×
“We have made a start on such a testing program using the resampling framework reported in [1], [11], [121], [146], [147].”
BackgroundMethodSelf-citationStudholme, C., Cardenas, V. A., Song, E., Ezekiel, F., Maudsley, A. A., & Weiner, M. W. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820029 · Cited by 53 · cited 1×
“A variety of algorithms have been developed for correcting intensity nonuniformities and new approaches are being continually developed [79], with an emphasis on correction in the presence of atrophy from dementia and aging [80] and longitudinal studies of structural changes over time [81].”
BackgroundParameter estimation in the magnitude-only and complex-valued fMRI data models
Rowe, D. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.12.048 · Cited by 51 · cited 1×
“There has also been a recent focus on using complex-valued fMRI time series to improve activation detection [2]–[4] and remove vascular artifacts [5].”
BackgroundDetecting bilateral abnormalities with voxel-based morphometry
Salmond, C. H., Ashburner, J., Vargha‐Khadem, F., Gadian, D. G., & Friston, K. J. (2000) · Human Brain Mapping · doi:10.1002/1097-0193(200011)11:3<193::aid-hbm50>3.0.co;2-z · Cited by 50 · cited 1×
“, warps) with hundreds of degrees of freedom (SPM, [91]; AIR, [90]), and 3) highly flexible warps with thousands of degrees of freedom [92]–[99].”
BackgroundAnisotropic 2-D and 3-D averaging of fMRI signals
Sole, A. F., Ngan, S.-C., Sapiro, G., Hu, X. P., & López, A. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.913175 · Cited by 48
k-Space based summary motion detection for functional magnetic resonance imaging
Caparelli, E. C., Tomasi, D. G., Arnold, S., Chang, L., & Ernst, T. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00339-2 · Cited by 43 · cited 1×
“Other Issues There are a number of other trends at this preprocessing stage: 1) using the pulse sequence to monitor rigid-body motion [54], 2) developing monitoring techniques as summary measures for QC [55] or to acquire the rigid-body transformations through external monitoring [56], and 3) volume-by-volume motion c…”
BackgroundSpatiotemporal wavelet analysis for functional MRI
Long, C., Brown, E. N., Manoach, D. S., & Solo, V. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.017 · Cited by 42 · cited 2×
“[11] have shown that optimal spatial smoothing settings vary from subject to subject, reinforcing the potential advantages of locally adaptive smoothing approaches [122]–[124] or combining results across multiple spatial smoothing scales [115], [117], [118].”
BackgroundComparison of functional MRI image realignment tools using a computer‐generated phantom
Morgan, V. L., Pickens, D. R., Hartmann, S. L., & Price, R. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1221 · Cited by 37 · cited 1×
“[32], who tested AFNI96 and AFNI98, SPM96 and SPM99b, and AIR3.”
BackgroundSubcortical, cerebellar, and magnetic resonance based consistent brain image registration
Magnotta, V. A., Bockholt, H. J., Johnson, H. J., Christensen, G. E., & Andreasen, N. C. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00100-9 · Cited by 34 · cited 1×
“[109] have shown average increases in relative regional overlap with increases in both the degrees of freedom of an intensity-based algorithm and the amount of anatomical landmark information used.”
BackgroundLiow, J. S., Rehm, K., Strother, S. C., Anderson, J., Mørch, N. J. S., Hansen, L. K., Schaper, K. A., & Rottenberg, D. A. (2000) · PubMed · Cited by 32
Self-citationDinov, I. D., Mega, M. S., Thompson, P. M., Woods, R. P., Sumners, D. L., Sowell, E. R., & Toga, A. W. (2002) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.992165 · Cited by 31 · cited 1×
“[112] compared PET activation resulting from seven- and 12–parameter affine and second- and fifth-order polynomial warps from AIR 3.”
Improving the spatial specificity of canonical correlation analysis in fMRI
Nandy, R. R., & Cordes, D. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20234 · Cited by 29
Bianciardi, M., Cerasa, A., Patria, F., & Hagberg, G. E. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.02.039 · Cited by 27 · cited 1×
“However, it is now clear that prewhitening—removal of temporal autocorrelation to whiten the residual noise—is feasible and should be used to improve parameter estimation efficiency for inferential significance testing of GLMs applied to single-voxel time series [84], [136].”
MethodImpact of inter-subject image registration on group analysis of fMRI data
Ardekani, B. A., Bachman, A. H., Strother, S. C., Fujibayashi, Y., & Yonekura, Y. (2004) · International Congress Series · doi:10.1016/j.ics.2004.02.169 · Cited by 26 · cited 2×
“[87] compared AFNI’s Talairach registration with SPM99’s warps and a highly flexible in-house algorithm (ART) and found a significant improvement in group-analysis results using ART.”
BackgroundMethodSelf-citationChanges in effective connectivity models in the presence of task‐correlated motion: An fMRI study
Gavrilescu, M. C., Stuart, G. W., Waites, A. B., Jackson, G. D., Svalbe, I., & Egan, G. F. (2003) · Human Brain Mapping · doi:10.1002/hbm.10149 · Cited by 26 · cited 1×
“I expect the interaction of preprocessing steps with the definition and analysis of ROIs to become an important topic, particularly for network analysis using structural equation models, which require a small number of stable time series to be extracted from predefined regions of the brain [10].”
MethodDeformation Based Representation of Groupwise Average and Variability
Kovacevic, N., Chen, X., Sled, J. G., Henderson, J., & Henkelman, R. M. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30135-6_75 · Cited by 23 · cited 1×
“There have been several proposals for developing such optimal, group-specific templates [28], [101]–[104], but to date their use has not been compared with the standard MNI/ICBM population-based templates.”
MethodComparison of matched BOLD and FAIR 4.0T-fMRI with [15O]water PET brain volumes
Zaini, M. R., Strother, S. C., Anderson, J., Liow, J., Kjems, U., Tegeler, C., & Kim, S.-G. (1999) · Medical Physics · doi:10.1118/1.598652 · Cited by 22 · cited 1×
“There are a number of other possible combinations of the above steps: 1) performing physiological correction before Registration I or after Registration III, 2) combining transformations from Registration I, II, and III into a single resampling step of the raw data into a common space, which minimizes interpolation sm…”
MethodSelf-citationMcKeown, M. J., & Hanlon, C. A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.12.021 · Cited by 17 · cited 1×
“This approach to data extraction and analysis was developed and widely used in the PET community in the 1980s and early 1990s before the development of voxel-based analysis techniques [126] and is becoming more common for fMRI analysis [127].”
MethodTIGER – A New Model for Spatio-temporal Realignment of FMRI Data
Bannister, P. R., Brady, J. M., & Jenkinson, M. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-27816-0_25 · Cited by 13
Exploratory Identification of Cardiac Noise in fMRI Images
Zöllei, L., Panych, L. P., Grimason, E., & Wells, W. M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39899-8_59 · Cited by 11 · cited 1×
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
BackgroundThe effects of geometric distortion correction on motion realignment in fMRI1
Elliott, M. A., Gualtieri, E., Hulvershorn, J., Ragland, J. D., & Gur, R. C. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.04.022 · Cited by 7 · cited 1×
“[50], who have recently shown that it improves registration of motion-corrected, EPI fMRI images to structural MRI images in 3 T and 4 T scanners, respectively.”
BackgroundReducing Activation-Related Bias in FMRI Registration
Freire, L., Orchard, J., Jenkinson, M., & Mangin, J. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-28626-4_34 · Cited by 6 · cited 1×
“Two possible approaches to solving this problem using modified computational frameworks with least squares cost functions have been proposed and are compared in [34].”
MethodA Developer's Commentary on Fiswidgets
Strother, S. C. (2003) · Neuroinformatics · doi:10.1385/ni:1:1:131 · Cited by 6
Self-citationA Gradient-Informed Robust Motion Correction Method for FMRI
Freire, L., & Jenkinson, M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39701-4_40 · Cited by 4
Identifying global anatomical differences: Deformation-based morphometry
(1998) · doi:10.1002/(sici)1097-0193(1998)6:5/6
Worsley (1996) · doi:10.1002/(sici)1097-0193(1996)4:1
High-resolution intersubject averaging and a coordinate system for the cortical surface
Fischl, B., Sereno, M. I., Tootell, R. B. H., & Dale, A. M. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<272::aid-hbm10>3.0.co;2-4 · cited 1×
“Recent developments include the use of structural landmarks to constrain warps across cortical surface representations on a sphere or a flattened representation [110], [111].”
BackgroundXiong (1999) · doi:10.1002/(sici)1097-0193(1999)8:2/3
Glover (2000) · doi:10.1002/1522-2594(200007)44:1<162::aid-mrm23>3.0.co;2-e · cited 2×
“Many other approaches have been proposed for suppressing the cardiac and respiratory noise, and they fall into four groups: two based on k-space/image measurements with application of the estimated physiological correction variables in k-space [62], [63] or the reconstructed images [64], [65] and two using external mo…”
Background
Research works printed but not linked: 14
- 10.1002/(SICI)1097-0193(1999)8:2/3<73::AID-HBM1>3.3.CO;2-Z · doi:10.1002/(sici)1097-0193(1999)8:2/3<73::aid-hbm1>3.3.co;2-z
- cox, 2004, A (Sort of) new image data format standard
- 10.1002/1522-2594(200101)45:1<167::AID-MRM1023>3.0.CO;2-M · DOI · Paper page
- toga, 2002, Brain Mapping The Methods
- 10.1002/(SICI)1097-0193(1999)7:4<267::AID-HBM5>3.0.CO;2-3 · DOI · Paper page
- 10.1002/(SICI)1522-2594(199905)41:5<964::AID-MRM16>3.0.CO;2-D · DOI · Paper page
- ward, 1999, Intracranial segmentation
- holmes, 1997, Statistical modeling of low-frequency confounds in fMRI. Neuroimage 5 (pt. 2 of 4):S480, NeuroImage, 5, 480s
- zhang, 2004, Exploring the Optimization of fMRI Processing Pipelines within the NPAIRS Framework, Annu Meeting Organ Hum Brain Mapping
- van horn, 2005, Number of distributable data sets originally processed with SPM., private communication
- 10.1002/(SICI)1097-0193(1996)4:1<74::AID-HBM5>3.3.CO;2-S · doi:10.1002/(sici)1097-0193(1996)4:1<74::aid-hbm5>3.3.co;2-s
- 10.1002/1522-2594(200012)44:6<925::AID-MRM14>3.0.CO;2-M · DOI
- 10.1002/(SICI)1097-0193(1998)6:5/6<339::AID-HBM3>3.0.CO;2-Q · doi:10.1002/(sici)1097-0193(1998)6:5/6<339::aid-hbm3>3.0.co;2-q
- talairach, 1988, Co-planar stereotaxic atlas of the human brain Stuttgart D
Cited by
fMRIPrep: A robust preprocessing pipeline for functional MRI
Esteban, O., Markiewicz, C. J., Blair, R. W., Moodie, C. A., Isik, A. I., Erramuzpe, A., Kent, J. D., Goncalves, M., DuPre, E., Snyder, M., et al. (2019) · Nature Methods · doi:10.1038/s41592-018-0235-4 · Cited by 3,905
Machine learning classifiers and fMRI: A tutorial overview
Pereira, F., Mitchell, T., & Botvinick, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.11.007 · Cited by 1,624
Zeng, L.-L., Shen, H., Liu, L., Wang, L., Li, B., Fang, P., Zhou, Z., Li, Y., & Hu, D. (2012) · Brain · doi:10.1093/brain/aws059 · Cited by 748
“Some physiological noises, such as cardiac and respira- tory rates, can alias into the low-frequency domain of functional MRI signals (Strother, 2006; Murphy et al., 2009).”
BackgroundMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
The secret lives of experiments: Methods reporting in the fMRI literature
Carp, J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.004 · Cited by 457
“While previous reports have reviewed and evaluated a wide range of analysis procedures (Churchill et al., 2012a,b; Strother, 2006), none has systematically evaluated the quality of methods reporting or the prevalence of competing analysis strategies in the research literature.”
Metadata
- Authors
- Strother, S. C.
- Affiliations
- University of Toronto (CA)
- Corresponding author
- Strother, S.C.
- ORCID
- Strother, S.C.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2006-03
- Volume
- 25
- Issue
- 2
- Pages
- 27-41
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2066954980
- Cited by
- 169
- References
- 144
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 5 · 2023: 8 · 2022: 10 · 2021: 11 · 2020: 5 · 2019: 7 · 2018: 9 · 2017: 9 · 2016: 7 · 2015: 5 · 2014: 10 · 2013: 14 · 2012: 12
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (P20 EB02013, P20EB002013)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Keywords
- fMRI preprocessing, BOLD fMRI, neuroimaging workflows, deoxyhemoglobin, functional neuroimaging
- MeSH terms
- Algorithms, Animals, Brain, Brain Mapping, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Oxygen, Technology Assessment, Biomedical, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.