The DOI matches its Crossref record; 215 of the 215 references it cites were found in a registry or an index.
Powered ankle-foot prosthesis
Abstract
The minimum level of series compliance that adequately protects the transmission from damage during foot collision fails to satisfy bandwidth requirements. As a resolution to this difficulty, parallel motor elasticity is used to lower the forces borne by the SEA, enhancing system force bandwidth. To minimize prosthesis cost of transport (COT) and motor or transmission size, we select a parallel stiffness that supplies the necessary ankle stiffness during early stance period dorsiflexion, eliminating the need for SEA during that gait phase. In future investigations, we hope to apply the ankle-foot design to robotic, orthotic, and exoskeletal applications. In the design of biomimetic ankle-foot systems, we feel both series and parallel motor elasticity are of paramount importance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-Objective Optimization Using Evolutionary Algorithms
Deb, K., & Kalyanmoy, D. (2001) · Andalas University Repository (Andalas University) · Cited by 17,328
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 3,669
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,021
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
Raibert, M. H., & Tello, E. R. (1986) · IEEE Expert · doi:10.1109/mex.1986.4307016 · Cited by 2,725
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
A View of the Em Algorithm that Justifies Incremental, Sparse, and other Variants
Neal, R. M., & Hinton, G. E. (1998) · Learning in Graphical Models · doi:10.1007/978-94-011-5014-9_12 · Cited by 2,187
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
The development of Honda humanoid robot
Hirai, K., Hirose, M., Haikawa, Y., & Takenaka, T. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.677288 · Cited by 1,922
Efficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873
Central pattern generators for locomotion control in animals and robots: A review
Ijspeert, A. J. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.014 · Cited by 1,853
The spring-mass model for running and hopping
Blickhan, R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90224-8 · Cited by 1,673
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationRHex: A Simple and Highly Mobile Hexapod Robot
Saranli, U., Buehler, M., & Koditschek, D. E. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067570 · Cited by 1,322
Is imitation learning the route to humanoid robots?
Schaal, S. (1999) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(99)01327-3 · Cited by 1,314
From Swimming to Walking with a Salamander Robot Driven by a Spinal Cord Model
Ijspeert, A. J., Crespi, A., Ryczko, D., & Cabelguen, J.-M. (2007) · Science · doi:10.1126/science.1138353 · Cited by 1,214
The mechanics of running: How does stiffness couple with speed?
McMahon, T. A., & Cheng, G. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90042-2 · Cited by 1,121
Dynamic Optimization of Human Walking
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392310 · Cited by 1,107
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Impedance Control: An Approach to Manipulation: Part II—Implementation
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140713 · Cited by 973
Learning of action through adaptive combination of motor primitives
Thoroughman, K. A., & Shadmehr, R. (2000) · Nature · doi:10.1038/35037588 · Cited by 945
Compliant leg behaviour explains basic dynamics of walking and running
Geyer, H., Seyfarth, A., & Blickhan, R. (2006) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2006.3637 · Cited by 940
(1976) · Advances in Behavioral Biology · doi:10.1007/978-1-4757-0964-3 · Cited by 916
Brown, T. G. (1914) · The Journal of Physiology · doi:10.1113/jphysiol.1914.sp001646 · Cited by 912
Featherstone, R. (1987) · Springer eBooks · doi:10.1007/978-0-387-74315-8 · Cited by 875
Energy cost of walking of amputees: the influence of level of amputation.
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · PubMed · Cited by 873
On the central generation of locomotion in the low spinal cat
Grillner, S., & Zangger, P. (1979) · Experimental Brain Research · doi:10.1007/bf00235671 · Cited by 838
The sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804
Kaneko, K., Kanehiro, F., Kajita, S., Hirukawa, H., Kawasaki, T., Hirata, M., Akachi, K., & Isozumi, T. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307969 · Cited by 759
Stair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Self-citationEnergetics of Actively Powered Locomotion Using the Simplest Walking Model
Kuo, A. D. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427703 · Cited by 736
Control of whole body balance in the frontal plane during human walking
MacKinnon, C. D., & Winter, D. A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90027-c · Cited by 725
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Donelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Robot Motion: Planning and Control
Brady, M., Hollerbach, J. M., Johnson, T., Mason, M. T., & Lozano‐Pérez, T. (1983) · Medical Entomology and Zoology · Cited by 615
Contribution to the Synthesis of Biped Gait
Vukobratovic, M., & Juricic, D. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502596 · Cited by 609
In vivo behaviour of human muscle tendon during walking
Fukunaga, T., Kubo, K., Kawakami, Y., Fukashiro, S., Kanehisa, H., & Maganaris, C. N. (2001) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2000.1361 · Cited by 589
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Energy Generation and Absorption at the Ankle and Knee during Fast, Natural, and Slow Cadences
WINTER, D. A. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00021 · Cited by 579
Postural Stability of Biped Robots and the Foot-Rotation Indicator (FRI) Point
Goswami, A. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066376 · Cited by 576
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
A model of the neuro-musculo-skeletal system for human locomotion: I. Emergence of basic gait
Taga, G. (1995) · Biological Cybernetics · doi:10.1007/bf00204048 · Cited by 557
Convergent force fields organized in the frog's spinal cord
Giszter, S., Mussa-Ivaldi, F., & Bizzi, E. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-02-00467.1993 · Cited by 544
Biomechanical Motor Patterns in Normal Walking
Winter, D. A. (1983) · Journal of Motor Behavior · doi:10.1080/00222895.1983.10735302 · Cited by 530
Biomechanics of below-knee amputee gait
Winter, D. A., & Sienko, S. E. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90142-x · Cited by 521
Simultaneous positive and negative external mechanical work in human walking
Donelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00169-5 · Cited by 517
Constructive Incremental Learning from Only Local Information
Schaal, S., & Atkeson, C. G. (1998) · Neural Computation · doi:10.1162/089976698300016963 · Cited by 517
Angular momentum in human walking
Herr, H., & Popovic, M. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.008573 · Cited by 498
Self-citationMuscle-tendon interaction and elastic energy usage in human walking
Ishikawa, M., Komi, P. V., Grey, M. J., Lepola, V., & Bruggemann, G.-P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00189.2005 · Cited by 497
A movement criterion for running
Seyfarth, A., Geyer, H., Günther, M., & Blickhan, R. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00245-7 · Cited by 490
Length dependence of active force production in skeletal muscle
Rassier, D. E., MacIntosh, B. R., & Herzog, W. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.5.1445 · Cited by 488
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Self-citationProprioception and locomotor disorders
Dietz, V. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn939 · Cited by 487
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487
Self-citationA human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Measure of Man and Woman: Human Factors in Design
Tilley, A. R. (1993) · Cumulative Index of Computer Aided Architectural Design · Cited by 451
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Controlled Elitist Non-dominated Sorting Genetic Algorithms for Better Convergence
Deb, K., & Goel, T. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-44719-9_5 · Cited by 446
A Simple Model of Bipedal Walking Predicts the Preferred Speed–Step Length Relationship
Kuo, A. D. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1372322 · Cited by 444
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Ruina, A., Bertram, J. E. A., & Srinivasan, M. (2005) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.04.004 · Cited by 433
Length and moment arm of human leg muscles as a function of knee and hip-joint angles
Visser, J. J., Hoogkamer, J. E., Bobbert, M. F., & Huijing, P. A. (1990) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00236067 · Cited by 429
Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Eilenberg, M. F., Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039620 · Cited by 419
Self-citationSpinal cord pattern generators for locomotion
Dietz, V. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00120-2 · Cited by 419
A New Mathematical Formulation for Strapdown Inertial Navigation
Bortz, J. (1971) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1971.310252 · Cited by 416
Modular control of human walking: A simulation study
Neptune, R. R., Clark, D. J., & Kautz, S. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.009 · Cited by 415
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D. J., & Pratt, G. A. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803231 · Cited by 409
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
The effect of walking speed on muscle function and mechanical energetics
Neptune, R. R., Sasaki, K., & Kautz, S. A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.11.004 · Cited by 403
Rybak, I. A., Shevtsova, N. A., Lafreniere‐Roula, M., & McCrea, D. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.118703 · Cited by 399
Direction-dependent control of balance during walking and standing
O'Connor, S. M., & Kuo, A. D. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00131.2009 · Cited by 393
Gait dynamics on an inclined walkway
McIntosh, A. S., Beatty, K. T., Dwan, L. N., & Vickers, D. R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.025 · Cited by 384
Swing-leg retraction: a simple control model for stable running
Seyfarth, A., Geyer, H., & Herr, H. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00463 · Cited by 370
Self-citationGenerating the walking gait: role of sensory feedback
Pearson, K. G. (2004) · Progress in Brain Research · doi:10.1016/s0079-6123(03)43012-4 · Cited by 354
The human ankle during walking: implications for design of biomimetic ankle prostheses
Hansen, A. H., Childress, D. S., Miff, S. C., Gard, S. A., & Mesplay, K. P. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.01.017 · Cited by 347
Lichtwark, G. A., & Wilson, A. M. (2006) · Journal of Experimental Biology · doi:10.1242/jeb.02434 · Cited by 333
Popovic, M. B., Goswami, A., & Herr, H. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905058363 · Cited by 327
Self-citationAccelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
Automated Derivation of Primitives for Movement Classification
Fod, A., Matarić, M. J., & Jenkins, O. C. (2002) · Autonomous Robots · doi:10.1023/a:1013254724861 · Cited by 318
Major role for sensory feedback in soleus EMG activity in the stance phase of walking in man
Sinkjær, T., Andersen, J. B., Ladouceur, M., Christensen, L. O. D., & Nielsen, J. B. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00817.x · Cited by 309
McKibben artificial muscles: pneumatic actuators with biomechanical intelligence
Klute, G. K., Czerniecki, J. M., & Hannaford, B. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803170 · Cited by 308
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Self-citationDirect dynamics simulation of the impact phase in heel-toe running
Gerritsen, K. G. M., van den Bogert, A. J., & Nigg, B. M. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00127-p · Cited by 300
User‐adaptive control of a magnetorheological prosthetic knee
Herr, H., & Wilkenfeld, A. (2003) · Industrial Robot: An International Journal · doi:10.1108/01439910310457706 · Cited by 293
Self-citationWHOLE-BODY DYNAMIC BEHAVIOR AND CONTROL OF HUMAN-LIKE ROBOTS
KHATIB, O., SENTIS, L., PARK, J., & WARREN, J. (2004) · International Journal of Humanoid Robotics · doi:10.1142/s0219843604000058 · Cited by 293
A system for the analysis of foot and ankle kinematics during gait
Kidder, S. M., Abuzzahab, F. S., Harris, G. F., & Johnson, J. E. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.486054 · Cited by 291
Force–length characteristics of in vivo human skeletal muscle
Maganaris, C. N. (2001) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2001.00799.x · Cited by 278
Electromyography: Some Methodological Problems and Issues
Türker, K. S. (1993) · Physical Therapy · doi:10.1093/ptj/73.10.698 · Cited by 268
Design and analysis of series elasticity in closed-loop actuator force control
Robinson, D. W. (2000) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 265
Myoelectric teleoperation of a complex robotic hand
Farry, K. A., Walker, I. D., & Baraniuk, R. G. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538982 · Cited by 248
Positive force feedback in bouncing gaits?
Geyer, H., Seyfarth, A., & Blickhan, R. (2003) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2003.2454 · Cited by 247
Hogan, N., & Mann, R. W. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326652 · Cited by 241
A multisensory posture control model of human upright stance
Mergner, T., Maurer, C., & Peterka, R. J. (2003) · Progress in Brain Research · doi:10.1016/s0079-6123(03)42014-1 · Cited by 239
Mechanics and energetics of swinging the human leg
Doke, J., Donelan, J. M., & Kuo, A. D. (2005) · Journal of Experimental Biology · doi:10.1242/jeb.01408 · Cited by 238
Force‐length characteristics of the in vivo human gastrocnemius muscle
Maganaris, C. N. (2003) · Clinical Anatomy · doi:10.1002/ca.10064 · Cited by 235
Prediction of gastrocnemius length from knee and ankle joint posture
Grieve, D. W. (1978) · Medical Entomology and Zoology · Cited by 228
Rybak, I. A., Stecina, K., Shevtsova, N. A., & McCrea, D. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.118711 · Cited by 223
Development of a lightweight, underactuated exoskeleton for load-carrying augmentation
Walsh, C. J., Paluska, D., Pasch, K., Grand, W., Valiente, A., & Herr, H. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642234 · Cited by 220
Self-citationMechanical power and efficiency of level walking with different stride rates
Umberger, B. R., & Martin, P. E. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.000950 · Cited by 220
Lower extremity kinematic and kinetic adaptations in unilateral below-knee amputees during walking
Sanderson, D. J., & Martin, P. E. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)01112-0 · Cited by 215
Coordination and decentralized cooperation of multiple mobile manipulators
Khatib, Yokoi, K., Chang, K., Ruspini, D., Holmberg, R., & Casal, A. (1996) · Journal of Robotic Systems · doi:10.1002/(sici)1097-4563(199611)13:11<755::aid-rob6>3.0.co;2-u · Cited by 212
Energy expenditure in below-knee amputees: correlation with stump length.
Gonzalez, E. G., Corcoran, P. J., & Reyes, R.-D. (1974) · PubMed · Cited by 211
Calf muscle moment, work and efficiency in level walking; Role of series elasticity
Hof, A. L., Geelen, B. A., & Van den Berg, J. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90067-2 · Cited by 209
Ekeberg, Ö., & Pearson, K. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00065.2005 · Cited by 208
Artificial Muscles: Actuators for Biorobotic Systems
Klute, G. K., Czerniecki, J. M., & Hannaford, B. (2002) · The International Journal of Robotics Research · doi:10.1177/027836402320556331 · Cited by 208
Minassian, K., Persy, I., Rattay, F., Pinter, M. M., Kern, H., & Dimitrijevic, M. R. (2007) · Human Movement Science · doi:10.1016/j.humov.2007.01.005 · Cited by 203
Change in length of relaxed muscle fascicles and tendons with knee and ankle movement in humans
Herbert, R. D., Moseley, A. M., Butler, J. E., & Gandevia, S. C. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012756 · Cited by 202
Generation of human bipedal locomotion by a bio-mimetic neuro-musculo-skeletal model
Ogihara, N., & YAMAZAKI, N. (2001) · Biological Cybernetics · doi:10.1007/pl00007977 · Cited by 193
Spinal reflexes, mechanisms and concepts: From Eccles to Lundberg and beyond
Hultborn, H. (2006) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2006.04.001 · Cited by 191
Running stability is enhanced by a proximo-distal gradient in joint neuromechanical control
Daley, M. A., Felix, G., & Biewener, A. A. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.02668 · Cited by 191
Energetics of walking and running: insights from simulated reduced-gravity experiments
Farley, C. T., & McMahon, T. A. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.6.2709 · Cited by 189
Taga, G. (1998) · Biological Cybernetics · doi:10.1007/s004220050408 · Cited by 188
Powered Ankle-Foot Prosthesis for the Improvement of Amputee Ambulation
Au, S. K., Herr, H., Weber, J., & Martinez-Villalpando, E. C. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352965 · Cited by 182
Self-citationUpper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Kinematic and Kinetic Variations of Below-Knee Amputee Gait
Bateni, H., & Olney, S. J. (2002) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200203000-00003 · Cited by 173
Positive Force Feedback Control of Muscles
Prochazka, A., Gillard, D., & Bennett, D. J. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.6.3226 · Cited by 171
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Three-dimensional acceleration of the tibia during walking and running
Lafortune, M. A. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90166-k · Cited by 169
Activity Levels Among Lower-Limb Amputees: Self-Report Versus Step Activity Monitor
Stepien, J. M., Cavenett, S., Taylor, L., & Crotty, M. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.03.016 · Cited by 163
Development of a myoelectric discrimination system for a multi-degree prosthetic hand
Huang, H.-P., & Chen, C.-Y. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.770463 · Cited by 162
An autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Self-citationSagittal plane characterization of normal human ankle function across a range of walking gait speeds
Palmer, M. L. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 160
A new view of the EM algorithm that justifies incremental and other variants
Neal, R. M. (1993) · Cited by 160
Biomechanical Design of a Powered Ankle-Foot Prosthesis
Au, S. K., Weber, J., & Herr, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428441 · Cited by 158
Self-citationRehabilitation After Amputation
Esquenazi, A., & DiGiacomo, R. (2001) · Journal of the American Podiatric Medical Association · doi:10.7547/87507315-91-1-13 · Cited by 158
Torburn, L., Powers, C., Guiterrez, R., & Perry, J. (1995) · PubMed · Cited by 157
Simulations of neuromuscular control in lamprey swimming
Ekeberg, Ö., & Grillner, S. E. (1999) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1999.0441 · Cited by 155
Hybrid FES orthosis incorporating closed loop control and sensory feedback
Andrews, B. J., Baxendale, R. H., Barnett, R., Phillips, G. F., Yamazaki, T., Paul, J. P., & Freeman, P. A. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90099-4 · Cited by 155
Graupe, D., Magnussen, J., & Beex, A. A. L. (1978) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1978.1101783 · Cited by 154
Integrated GPS/INS System for Pedestrian Navigation in a Signal Degraded Environment
Godha, S., Lachapelle, G., Cannon, M. E., & Godha, S. (2006) · Cited by 153
Inertial sensing of human movement
Luinge, H. J. (2002) · University of Twente Research Information · Cited by 148
An EMG-Position Controlled System for an Active Ankle-Foot Prosthesis: An Initial Experimental Study
Au, S. K., Bonato, P., & Herr, H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501123 · Cited by 147
Self-citationBayesian Filtering of Myoelectric Signals
Sanger, T. D. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00936.2006 · Cited by 146
A distribution-moment model of energetics in skeletal muscle
Ma, S.-P., & Zahalak, G. I. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90323-f · Cited by 140
Neural network control of functional neuromuscular stimulation systems: computer simulation studies
Abbas, J. J., & Chizeck, H. J. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.469379 · Cited by 140
A Simply Stabilized Running Model
Ghigliazza, R. M., Altendorfer, R., Holmes, P. J., & Koditschek, D. E. (2003) · SIAM Journal on Applied Dynamical Systems · doi:10.1137/s1111111102408311 · Cited by 139
Exotendons for assistance of human locomotion
van den Bogert, A. J. (2003) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-2-17 · Cited by 139
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333984 · Cited by 136
Contribution of stretch reflexes to locomotor control: a modeling study
Yakovenko, S., Gritsenko, V., & Procházka, A. (2004) · Biological Cybernetics · doi:10.1007/s00422-003-0449-z · Cited by 135
Colborne, G., Naumann, S., Longmuir, P. E., & Berbrayer, D. (1992) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199210000-00004 · Cited by 132
Real-time gait assessment utilizing a new way of accelerometry
Willemsen, A., van Alste, J. A., & Boom, H. B. K. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90033-y · Cited by 130
Machine learning in control of functional electrical stimulation systems for locomotion
Kostov, A., Andrews, B. J., Popović, D. B., Stein, R. B., & Armstrong, W. W. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387193 · Cited by 130
Assessing sensory function in locomotor systems using neuro-mechanical simulations
Pearson, K. G., Ekeberg, Ö., & Büschges, A. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.08.007 · Cited by 127
Energy/speed relation of below-knee amputees walking on a motor-driven treadmill
Molen, N. H. (1973) · European Journal of Applied Physiology · doi:10.1007/bf00697597 · Cited by 122
Hsu, M., Nielsen, D. H., Lin, S.-J., & Shurr, D. G. (2006) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.07.310 · Cited by 118
Magnusson, S. P., Beyer, N., Abrahamsen, H., Aagaard, P., Neergaard, K., & Kjær, M. (2003) · The Journals of Gerontology Series A · doi:10.1093/gerona/58.2.b123 · Cited by 118
New horizons for orthotic and prosthetic technology: artificial muscle for ambulation
Herr, H., & Kornbluh, R. D. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.544510 · Cited by 115
Self-citationEstimation of speed and incline of walking using neural network
Aminian, K., Robert, P., Jéquier, E., & Schutz, Y. (1995) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.387322 · Cited by 114
Experiments and models of sensorimotor interactions during locomotion
Frigon, A., & Rossignol, S. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0129-x · Cited by 113
New control strategies for neuroprosthetic systems.
Crago, P. E., Lan, N., Veltink, P. H., Abbas, J. J., & Kantor, C. (1996) · PubMed · Cited by 113
Three machine learning techniques for automatic determination of rules to control locomotion
Jonić, S., Jankovic, T., Gajic, V., & Popvic, D. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748983 · Cited by 111
Human Arm Movements Described by a Low-Dimensional Superposition of Principal Components
Sanger, T. D. (2000) · Journal of Neuroscience · doi:10.1523/jneurosci.20-03-01066.2000 · Cited by 109
Positive force feedback in human walking
Grey, M. J., Nielsen, J. B., Mazzaro, N., & Sinkjær, T. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.130088 · Cited by 109
Rietman, J. S., Postema, K., & Geertzen, J. H. B. (2002) · Prosthetics and Orthotics International · doi:10.1080/03093640208726621 · Cited by 106
A method for inverse dynamic analysis using accelerometry
van den Bogert, A. J., Read, L., & Nigg, B. M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00155-7 · Cited by 99
Essentials of dynamic walking; analysis and design of two-legged robots
Wisse, M. (2004) · Research Repository (Delft University of Technology) · Cited by 96
Legged robots at MIT: what's new since Raibert?
Pratt, G. A. (2000) · IEEE Robotics & Automation Magazine · doi:10.1109/100.876907 · Cited by 93
A Simple Design for A Force-Plate to Measure Ground Reaction Forces
Heglund, N. C. (1981) · Journal of Experimental Biology · doi:10.1242/jeb.93.1.333 · Cited by 92
Lundberg, A., & Oslo, N. V.-A. I. (1969) · Universitetsforlaget eBooks · Cited by 87
Peeraer, L., Aeyels, B., & der Perre, G. V. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90037-n · Cited by 87
A model of scale effects in mammalian quadrupedal running
Herr, H., Huang, G. T., & McMahon, T. A. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.7.959 · Cited by 87
Self-citationFinite-state control of a trans-femoral (TF) prosthesis
Zlatnik, D., Steiner, B., & Schweitzer, G. (2002) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.998030 · Cited by 84
A review of the methods of processing EMG for use as a proportional control signal.
Hogan, N. (1976) · PubMed · Cited by 83
Automatic detection of gait events: a case study using inductive learning techniques
Kirkwood, C. A., Andrews, B. J., & Mowforth, P. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90046-0 · Cited by 82
Abul-Haj, C., & Hogen, N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1990.1438510 · Cited by 82
Rehabilitation after amputation
Dong-yu, Y. (2002) · Journal of Modern Rehabilitation · Cited by 81
Design and Control of an Electrically Powered Knee Prosthesis
Fite, K. B., Mitchell, J. E., Sup, F. C., & Goldfarb, M. T. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428531 · Cited by 79
Hitt, J. K., Bellman, R. D., Holgate, M. A., Sugar, T. G., & Hollander, K. W. (2007) · doi:10.1115/detc2007-34512 · Cited by 78
Kazunori, H. A. S. E., & YAMAZAKI, N. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.1040 · Cited by 76
Pratt, G. A. (2002) · Integrative and Comparative Biology · doi:10.1093/icb/42.1.174 · Cited by 74
Quantification of pelvic rotation as a determinant of gait
Kerrigan, D. C., Riley, P. O., Lelas, J. L., & Croce, U. D. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.18063 · Cited by 73
Pratt, J. E., Torres, A. L., Dilworth, P., & Pratt, G. A. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1996.568974 · Cited by 72
Herr, H., & McMahon, T. A. (2000) · The International Journal of Robotics Research · doi:10.1177/027836490001900602 · Cited by 70
Self-citationControl aspects of active above-knee prosthesis
Popović, D. B., Tomović, R., Tepavac, D., & Schwirtlich, L. B. (1991) · International Journal of Man-Machine Studies · doi:10.1016/s0020-7373(05)80159-2 · Cited by 67
Modeling the spinal cord neural circuitry controlling cat hindlimb movement during locomotion
Ivashko, D. G., Prilutsky, B. I., Markin, S. N., Chapin, J. K., & Rybak, I. A. (2003) · Neurocomputing · doi:10.1016/s0925-2312(02)00832-9 · Cited by 65
Principles of Walking and Running
McGeer, T. (1992) · Advances in comparative and environmental physiology · doi:10.1007/978-3-642-76693-0_4 · Cited by 64
Development of a human neuro-musculo-skeletal model for investigation of spinal cord injury
Paul, C., Bellotti, M., Jezernik, S., & Curt, A. E. P. (2005) · Biological Cybernetics · doi:10.1007/s00422-005-0559-x · Cited by 59
The neuromechanical tuning hypothesis
Procházka, A., & Yakovenko, S. (2007) · Progress in brain research · doi:10.1016/s0079-6123(06)65016-4 · Cited by 58
Within‐step modulation of leg muscle activity by afferent feedback in human walking
af Klint, R., Nielsen, J. B., Cole, J. D., Sinkjær, T., & Grey, M. J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2008.155002 · Cited by 56
Towards a general neural controller for quadrupedal locomotion
Maufroy, C., Kimura, H., & Takase, K. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.010 · Cited by 55
Force Regulation of Ankle Extensor Muscle Activity in Freely Walking Cats
Donelan, J. M., McVea, D. A., & Pearson, K. G. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90918.2008 · Cited by 55
Muscle fiber and tendon length changes in the human vastus lateralis during slow pedaling
Muraoka, T., Kawakami, Y., Tachi, M., & Fukunaga, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.5.2035 · Cited by 54
An automated accelerometry system for gait analysis
Smidt, G. L., Deusinger, R. H., Arora, J. S., & Albright, J. P. (1977) · Journal of Biomechanics · doi:10.1016/0021-9290(77)90009-4 · Cited by 50
Human leg design: optimal axial alignment under constraints
G�nther, M., Keppler, V., Seyfarth, A., & Blickhan, R. (2004) · Journal of Mathematical Biology · doi:10.1007/s00285-004-0269-3 · Cited by 48
Hayes, W. C., Gran, J. D., Nagurka, M. L., Feldman, J. M., & Oatis, C. A. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138419 · Cited by 48
Mechanical and neural stretch responses of the human soleus muscle at different walking speeds
Cronin, N. J., Ishikawa, M., Grey, M. J., af Klint, R., Komi, P. V., Avela, J., Sinkjær, T., & Voigt, M. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2008.162610 · Cited by 47
The study of kinematic transients in locomotion using the integrated kinematic sensor
Wu, G., & Ladin, Z. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.536775 · Cited by 46
Cited by
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Self-citationPowered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487
Self-citationVariable Stiffness Actuators: Review on Design and Components
Wolf, S., Grioli, G., Eiberger, O., Friedl, W., Grebenstein, M., Hoppner, H., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M. G., et al. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2501019 · Cited by 459
Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Eilenberg, M. F., Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039620 · Cited by 419
Self-citationBionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Self-citation
Metadata
- Authors
- Au, S., & Herr, H.
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2008-09
- Volume
- 15
- Issue
- 3
- Pages
- 52-59
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W2053186023
- Cited by
- 280
- References
- 215
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.