Abstract
Despite not recording directly from neural cells, the surface electromyogram (EMG) signal contains information on the neural drive to muscles, i.e., the spike trains of motor neurons. Using this property, myoelectric control consists of the recording of EMG signals for extracting control signals to command external devices, such as hand prostheses. In commercial control systems, the intensity of muscle activity is extracted from the EMG and used for single degrees of freedom activation (direct control). Over the past 60 years, academic research has progressed to more sophisticated approaches but, surprisingly, none of these academic achievements has been implemented in commercial systems so far. We provide an overview of both commercial and academic myoelectric control systems and we analyze their performance with respect to the characteristics of the ideal myocontroller. Classic and relatively novel academic methods are described, including techniques for simultaneous and proportional control of multiple degrees of freedom and the use of individual motor neuron spike trains for direct control. The conclusion is that the gap between industry and academia is due to the relatively small functional improvement in daily situations that academic systems offer, despite the promising laboratory results, at the expense of a substantial reduction in robustness. None of the systems so far proposed in the literature fulfills all the important criteria needed for widespread acceptance by the patients, i.e. intuitive, closed-loop, adaptive, and robust real-time ( 200 ms delay) control, minimal number of recording electrodes with low sensitivity to repositioning, minimal training, limited complexity and low consumption. Nonetheless, in recent years, important efforts have been invested in matching these criteria, with relevant steps forwards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“When the neuromuscular system is probed for information extraction, the interfacing can be realized at the level of the brain and other supraspinal areas [1]–[3], peripheral nerves [4]–[6], or muscles [7], [8].”
BackgroundA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573 · cited 2×
“Because most myoelectric control schemes use macro-features of the surface EMG, that depend on the neural and peripheral information contained in the signal, their performance is influenced by the factors that can affect the motor unit action potential shapes or the neural drive to the muscle [23], [30].”
BackgroundSelf-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 3×
“As alternative to conventional control algorithms implemented in commercial devices, pattern recognition methods have been applied for several decades for classifying EMG signals [10], [11].”
BackgroundMethodUpper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“The notion of surface EMG recordings as sources of neural information is emphasized by the emerging procedure of targeted muscle reinnervation (TMR), that redirects nerves that would reach the missing limb muscles to innervate accessory muscles, from which surface EMG is recorded and the motion intent of the amputees…”
BackgroundScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Behaviour of human motor units in different muscles during linearly varying contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014293 · Cited by 719
Shared and specific muscle synergies in natural motor behaviors
d'Avella, A., & Bizzi, E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0500199102 · Cited by 707
Computations Underlying the Execution of Movement: A Biological Perspective
Bizzi, E., Mussa-Ivaldi, F. A., & Giszter, S. (1991) · Science · doi:10.1126/science.1857964 · Cited by 677
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Self-citationClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Self-citationKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583 · cited 1×
“When these muscle activities are mapped into controlling DoFs associated to the natural function of the redirected nerves, the direct control is intuitive and allows multiple DoFs to be controlled naturally [15], [37], [38].”
BackgroundDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Decomposition of Surface EMG Signals
De Luca, C. J., Adam, A., Wotiz, R., Gilmore, L. D., & Nawab, S. H. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00009.2006 · Cited by 511
Control scheme governing concurrently active human motor units during voluntary contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014294 · Cited by 510
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495 · cited 1×
“Among these potential options, the muscle interfacing is currently the only viable way to control external devices in commercial and clinical systems [9]–[12].”
BackgroundSensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Resolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
Influence of amplitude cancellation on the simulated surface electromyogram
Keenan, K. G., Farina, D., Maluf, K. S., Merletti, R., & Enoka, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00894.2004 · Cited by 389
Self-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383 · cited 3×
“The surface EMG is obtained by convolution of each motor neuron spike train by the motor unit action potential [7], [21], [22]:”
BackgroundMethodSelf-citationInfluence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Self-citationLinear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Self-citationNegro, F., Holobar, A., & Farina, D. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.178509 · Cited by 336
Self-citationLearning to integrate arbitrary signals from vision and touch
Ernst, M. O. (2007) · Journal of Vision · doi:10.1167/7.5.7 · Cited by 332
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318 · cited 1×
“sively tested and validated on a large set of both simulated [94]”
BackgroundSelf-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Hargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 2×
“This approach has the interesting property of being unsupervised since any multichannel recording can be factorized, although in practice a short calibration is needed to solve the factorization indeterminacies [82], [84].”
BackgroundSelf-citationEMG-Based Control of a Robot Arm Using Low-Dimensional Embeddings
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2039378 · Cited by 267
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Self-citationHolobar, A., Minetto, M. A., Botter, A., Negro, F., & Farina, D. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2041593 · Cited by 255
Self-citationProsthesis rejection in acquired major upper-limb amputees: a population-based survey
Østlie, K., Lesjø, I. M., Franklin, R. J., Garfelt, B., Skjeldal, O. H., & Magnus, P. (2012) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2011.635405 · Cited by 241
New perspectives on spinal motor systems
Bizzi, E., Tresch, M. C., Saltiel, P., & d'Avella, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35039000 · Cited by 230
Hargrove, L. J., Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039590 · Cited by 219
Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
Self-citationDavidson, J. (2002) · Journal of Hand Therapy · doi:10.1016/s0894-1130(02)50011-9 · Cited by 206
Myoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 203
The size-principle: a deterministic output emerges from a set of probabilistic connections
Henneman, E. (1985) · Journal of Experimental Biology · doi:10.1242/jeb.115.1.105 · Cited by 192
Bionic prosthetic hands: A review of present technology and future aspirations
Clement, R. G. E., Bugler, K. E., & Oliver, C. W. (2011) · The Surgeon · doi:10.1016/j.surge.2011.06.001 · Cited by 189
Geng, Y., Zhou, P., & Li, G. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-74 · Cited by 183
Jiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181
Self-citationGazzoni, M., Farina, D., & Merletti, R. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.01.002 · Cited by 179
Self-citationMuceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
Self-citationMyoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Lorrain, T., Jiang, N., & Farina, D. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-25 · Cited by 165
Self-citationAccessing the Neural Drive to Muscle and Translation to Neurorehabilitation Technologies
Farina, D., & Negro, F. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2183586 · Cited by 162
Self-citationExamining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158 · cited 1×
“, force) (closed-loop control) [39], [40].”
Signal processing for the multistate myoelectric channel
Parker, P. A., Stuller, J. A., & Scott, R. N. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10545 · Cited by 147
Cognitive vision system for control of dexterous prosthetic hands: Experimental evaluation
Došen, S., Cipriani, C., Kostić, M., Controzzi, M., Carrozza, M. C., & Popović, D. B. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-42 · Cited by 145
Using Ultrasound Images of the Forearm to Predict Finger Positions
Castellini, C., Passig, G., & Zarka, E. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2207916 · Cited by 143
Real-Time Motor Unit Identification From High-Density Surface EMG
Glaser, V., Holobar, A., & Zazula, D. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2247631 · Cited by 143
Self-citationTHE USE OF MYO-ELECTRIC CURRENTS IN THE OPERATION OF PROSTHESES
Battye, C. K., Nightingale, A., & Whillis, J. (1955) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.37b3.506 · Cited by 129
Effect of arm position on the prediction of kinematics from EMG in amputees
Jiang, N., Muceli, S., Graimann, B., & Farina, D. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0979-4 · Cited by 126
Self-citationSebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 125
Fluctuating emg signals: Investigating long-term effects of pattern matching algorithms
Kaufmann, P. M., Englehart, K. B., & Platzner, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627288 · Cited by 123
Effect of motor-unit firing time statistics on e.m.g. spectra
Lago, P. J. A., & Jones, N. B. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457923 · Cited by 122
A three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 119
Targeted Reinnervation for Improved Prosthetic Function
Kuiken, T. (2006) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2005.10.001 · Cited by 111
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · cited 1×
“When the neuromuscular system is probed for information extraction, the interfacing can be realized at the level of the brain and other supraspinal areas [1]–[3], peripheral nerves [4]–[6], or muscles [7], [8].”
BackgroundScheme, E., & Englehart, K. B. (2013) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e318289950b · Cited by 101
Real-Time, Simultaneous Myoelectric Control Using Force and Position-Based Training Paradigms
Ameri, A., Scheme, E., Kamavuako, E. N., Englehart, K. B., & Parker, P. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281595 · Cited by 98
Non-invasive characterization of motor unit behaviour in pathological tremor
Holobar, A., Glaser, V, Gallego, J. A., Dideriksen, J. L., & Farina, D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056011 · Cited by 91
Self-citationChapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Statistics of the myoelectric signal from monopolar and bipolar electrodes
Parker, P. A., & Scott, R. N. (1973) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477404 · Cited by 68
Long term stability of surface EMG pattern classification for prosthetic control
Amsüss, S., Paredes, L. P., Rudigkeit, N., Graimann, B., Herrmann, J. M., & Farina, D. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610327 · Cited by 68
Self-citationSebelius, F., Eriksson, L., Balkenius, C., & Laurell, T. (2006) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331332546 · Cited by 57
Farina, D., Rehbaum, H., Holobar, A., Vujaklija, I., Jiang, N., Hofer, C., Salminger, S., van Vliet, H.-W., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2306000 · Cited by 51
Self-citationSelektive Nerventransfers zur verbesserten Steuerung myoelektrischer Armprothesen
Aszmann, O., Dietl, H., & Frey, M. (2008) · Handchirurgie · Mikrochirurgie · Plastische Chirurgie · doi:10.1055/s-2007-989415 · Cited by 49
Self-citationTransradial Prosthesis: Artificial Vision for Control of Prehension
Dosen, S. S., & Popović, D. B. (2010) · Artificial Organs · doi:10.1111/j.1525-1594.2010.01040.x · Cited by 49
Rehbaum, H., Jiang, N., Paredes, L. P., Amsuess, S., Graimann, B., & Farina, D. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346187 · Cited by 45
Self-citationSignal Processing for Proportional Myoelectric Control
Evans, H. B., Pan, Z., Parker, P. A., & Scott, R. N. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325330 · Cited by 42
Control of upper-limb prostheses
Luca, C. J. D. (1978) · Journal of Medical Engineering & Technology · doi:10.3109/03091907809161756 · Cited by 41
Muceli, S., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627622 · Cited by 40
Self-citationA new hierarchical approach for simultaneous control of multi-joint powered prostheses
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290709 · Cited by 33
Controlling a prosthetic arm with a throat microphone
Mainardi, E., & Davalli, A. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352968 · Cited by 30
Time-dependent spectral features for limb position invariant myoelectric pattern recognition
Khushaba, R. N., Shi, L., & Kodagoda, S. (2012) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit.2012.6380840 · Cited by 29
Effects of Long-Term Myoelectric Signals on Pattern Recognition
He, J., Zhang, D., Sheng, X., & Zhu, X. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40852-6_40 · Cited by 28
Task discrimination from myoelectric activity: A learning scheme for EMG-based interfaces
Liarokapis, M. V., Artemiadis, P., & Kyriakopoulos, K. J. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650366 · Cited by 25
Study on fatigue feature from forearm SEMG signal based on wavelet analysis
Wan, B., Xu, L., Ren, Y., Wang, L., Qiu, S., Liu, X., Liu, X., Qi, H., Ming, D., & Wang, W. (2010) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2010.5723504 · Cited by 24
ART2 Neural Network for Surface EMG Decomposition
Xu, Z., Xiao, S., & Chi, Z. (2001) · Neural Computing and Applications · doi:10.1007/s005210170015 · Cited by 23
Stieglitz, T., Schüettler, M., & Koch, K. P. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.015 · Cited by 23
Evaluation of classifier topologies for the real-time classification of simultaneous limb motions
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B. E. V. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611081 · Cited by 17
The Use of Brain-Computer Interfacing in Ambient Intelligence
Garipelli, G., Galán, F., Chavarriaga, R., Ferrez, P. W., Lew, E. Y. L., & Millán, J. D. R. (2008) · Communications in computer and information science · doi:10.1007/978-3-540-85379-4_34 · Cited by 15
Ortiz-Catalan, M., Håkansson, B. E. V., & Brånemark, R. (2013) · Chalmers Research (Chalmers University of Technology) · Cited by 11
Motion recognition for simultaneous control of multifunctional transradial prostheses
Jiang, N., Tian, L., Fang, P., Dai, Y., & Li, G. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609822 · Cited by 9
Self-citation
Cited by
Progress and prospects of the human–robot collaboration
Ajoudani, A., Zanchettin, A. M., Ivaldi, S., Albu-Schäffer, A., Kosuge, K., & Khatib, O. (2018) · Autonomous Robots · doi:10.1007/s10514-017-9677-2 · Cited by 832
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Proportional and simultaneous control of a large number of degrees of freedom of the prosthesis can allow achieving more natural and dexterous control using unsupervised or supervised methods (Fougner et al., 2012; Farina et al., 2014).”
BackgroundMethodGesture recognition by instantaneous surface EMG images
Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J. (2016) · Scientific Reports · doi:10.1038/srep36571 · Cited by 595
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Comparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Metadata
- Authors
- Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-07
- Volume
- 22
- Issue
- 4
- Pages
- 797-809
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2066327120
- Cited by
- 992
- References
- 100
- FWCI
- 30.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.