Organ-on-a-chip: recent breakthroughs and future prospects
Open accessThe DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
The organ-on-a-chip (OOAC) is in the list of top 10 emerging technologies and refers to a physiological organ biomimetic system built on a microfluidic chip. Through a combination of cell biology, engineering, and biomaterial technology, the microenvironment of the chip simulates that of the organ in terms of tissue interfaces and mechanical stimulation. This reflects the structural and functional characteristics of human tissue and can predict response to an array of stimuli including drug responses and environmental effects. OOAC has broad applications in precision medicine and biological defense strategies. Here, we introduce the concepts of OOAC and review its application to the construction of physiological models, drug development, and toxicology from the perspective of different organs. We further discuss existing challenges and provide future perspectives for its application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilineage potential of adult human mesenchymal stem cells
Pittenger, M. F., Mackay, A. M., Beck, S. C., Jaiswal, R. K., Douglas, R., Mosca, J. D., Moorman, M. A., Simonetti, D. W., Craig, S., & Marshak, D. R. (1999) · Science · doi:10.1126/science.284.5411.143 · Cited by 21,052
Embryonic Stem Cell Lines Derived from Human Blastocysts
Thomson, J. A., Itskovitz-Eldor, J., Shapiro, S. S., Waknitz, M. A., Swiergiel, J. J., Marshall, V. S., & Jones, J. M. (1998) · Science · doi:10.1126/science.282.5391.1145 · Cited by 15,926
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 1×
“The microchannel is small, but has a large surface area and high mass transfer, favoring its use in microfluidic technology applications including low regent usage, controllable volumes, fast mixing speeds, rapid responses, and precision control of physical and chemical properties [1, 5, 6].”
BackgroundMicrofluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Growing Self-Organizing Mini-Guts from a Single Intestinal Stem Cell: Mechanism and Applications
Sato, T., & Clevers, H. (2013) · Science · doi:10.1126/science.1234852 · Cited by 1,170
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993 · cited 2×
“This produced a pathological model of pulmonary edema through the introduction of interleukin-2 (IL-2) [65].”
BackgroundBioprinting 3D microfibrous scaffolds for engineering endothelialized myocardium and heart-on-a-chip
Zhang, Y. S., Arneri, A., Bersini, S., Shin, S.-R., Zhu, K., Goli-Malekabadi, Z., Aleman, J., Colosi, C., Busignani, F., Dell'Erba, V., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.003 · Cited by 951
Kim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
A complex human gut microbiome cultured in an anaerobic intestine-on-a-chip
Jalili-Firoozinezhad, S., Gazzaniga, F. S., Calamari, E. L., Camacho, D. M., Fadel, C. W., Bein, A., Swenor, B., Nestor, B., Cronce, M. J., Tovaglieri, A., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0397-0 · Cited by 855
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Small airway-on-a-chip enables analysis of human lung inflammation and drug responses in vitro
Benam, K. H., Villenave, R., Lucchesi, C., Varone, A., Hubeau, C., Lee, H.-H., Alves, S. E., Salmon, M., Ferrante, T. C., Weaver, J. C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3697 · Cited by 816
Development of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657 · cited 1×
“simple “rocker” on a chip fluid motion, or through a more complex programmable “pulsatile” format, arranged in a single loop for organization-specific configurations [32].”
BackgroundMulti-tissue interactions in an integrated three-tissue organ-on-a-chip platform
Skardal, A., Murphy, S. V., Devarasetty, M., Mead, I., Kang, H.-W., Seol, Y.-J., Shrike Zhang, Y., Shin, S.-R., Zhao, L., Aleman, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08879-x · Cited by 623
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615 · cited 1×
“Culture systems require the control of external and internal cell environments [28].”
BackgroundZhang, B., Montgomery, M., Chamberlain, M. D., Ogawa, S., Korolj, A., Pahnke, A., Wells, L. A., Massé, S., Kim, J., Reis, L., et al. (2016) · Nature Materials · doi:10.1038/nmat4570 · Cited by 593
Zhang, D., Shadrin, I. Y., Lam, J., Xian, H.-Q., Snodgrass, H. R., & Bursac, N. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.026 · Cited by 565
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.
Figeys, D., & Pinto, D. (2000) · Analytical Chemistry · doi:10.1021/ac002800y · Cited by 562
VanDussen, K. L., Marinshaw, J. M., Shaikh, N., Miyoshi, H., Moon, C., Tarr, P. I., Ciorba, M. A., & Stappenbeck, T. S. (2015) · Gut · doi:10.1136/gutjnl-2013-306651 · Cited by 525
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Biomimetic model to reconstitute angiogenic sprouting morphogenesis in vitro
Nguyen, D.-H. T., Stapleton, S. C., Yang, M. T., Cha, S. S., Choi, C. K., Galie, P. A., & Chen, C. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221526110 · Cited by 493
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Self-citationWagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
Tubuloids derived from human adult kidney and urine for personalized disease modeling
Schutgens, F., Rookmaaker, M. B., Margaritis, T., Rios, A., Ammerlaan, C., Jansen, J., Gijzen, L., Vormann, M., Vonk, A., Viveen, M., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0048-8 · Cited by 449
Marsano, A., Conficconi, C., Lemme, M., Occhetta, P., Gaudiello, E., Votta, E., Cerino, G., Redaelli, A., & Rasponi, M. (2016) · Lab on a Chip · doi:10.1039/c5lc01356a · Cited by 447
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Fluid shear stress threshold regulates angiogenic sprouting
Galie, P. A., Nguyen, D.-H. T., Choi, C. K., Cohen, D. M., Janmey, P. A., & Chen, C. S. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1310842111 · Cited by 421
A lung-on-a-chip array with an integrated bio-inspired respiration mechanism
Stucki, A. O., Stucki, J. D., Hall, S. R. R., Felder, M., Mermoud, Y., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c4lc01252f · Cited by 410
Wevers, N. R., Kasi, D. G., Gray, T., Wilschut, K. J., Smith, B., van Vught, R., Shimizu, F., Sano, Y., Kanda, T., Marsh, G., et al. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0108-3 · Cited by 353
Surface modification for PDMS‐based microfluidic devices
Zhou, J., Khodakov, D. A., Ellis, A. V., & Voelcker, N. H. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100482 · Cited by 344
Microscale 3-D hydrogel scaffold for biomimetic gastrointestinal (GI) tract model
Sung, J. H., Yu, J., Luo, D., Shuler, M. L., & March, J. C. (2011) · Lab Chip · doi:10.1039/c0lc00273a · Cited by 320
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Control of stem cell fate and function by engineering physical microenvironments
Kshitiz, Park, J., Kim, P., Helen, W., Engler, A. J., Levchenko, A., & Kim, D.-H. (2012) · Integrative Biology · doi:10.1039/c2ib20080e · Cited by 267
Microfluidics—downsizing large-scale biology
Mitchell, P. (2001) · Nature Biotechnology · doi:10.1038/90754 · Cited by 264
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac051856v · Cited by 264
Mesenchymal Stem Cell Preparations—Comparing Apples and Oranges
Wagner, W., & Ho, A. D. (2007) · Stem Cell Reviews · doi:10.1007/s12015-007-9001-1 · Cited by 263
Organs-on-a-Chip Module: A Review from the Development and Applications Perspective
Sosa-Hernández, J. E., Villalba-Rodríguez, A. M., Romero-Castillo, K. D., Aguilar-Aguila-Isaías, M. A., García-Reyes, I. E., Hernández-Antonio, A., Ahmed, I., Sharma, A., Parra-Saldívar, R., & Iqbal, H. M. N. (2018) · Micromachines · doi:10.3390/mi9100536 · Cited by 244
Nanofiber membrane supported lung-on-a-chip microdevice for anti-cancer drug testing
Yang, X., Li, K., Zhang, X., Liu, C., Guo, B., Wen, W., & Gao, X. (2018) · Lab on a Chip · doi:10.1039/c7lc01224a · Cited by 240
Self-citationSung, J. H., Esch, M. B., Prot, J.-M., Long, C. J., Smith, A., Hickman, J. J., & Shuler, M. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41017j · Cited by 233
Liver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Daw, R., & Finkelstein, J. (2006) · Nature · doi:10.1038/442367a · Cited by 230
Tsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Khodabukus, A., Madden, L., Prabhu, N. K., Koves, T. R., Jackman, C. P., Muoio, D. M., & Bursac, N. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.058 · Cited by 221
Maschmeyer, I., Hasenberg, T., Jaenicke, A., Lindner, M., Lorenz, A. K., Zech, J., Garbe, L.-A., Sonntag, F., Hayden, P., Ayehunie, S., et al. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.03.002 · Cited by 218
State-of-the-art of 3D cultures (organs-on-a-chip) in safety testing and pathophysiology
Alépée, N. (2014) · ALTEX · doi:10.14573/altex.1406111 · Cited by 217
Paguirigan, A. L., & Beebe, D. J. (2008) · BioEssays · doi:10.1002/bies.20804 · Cited by 208
Humayun, M., Chow, C.-W., & Young, E. W. K. (2018) · Lab on a Chip · doi:10.1039/c7lc01357d · Cited by 206
van Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
Microsensor systems for cell metabolism – from 2D culture to organ-on-chip
Kieninger, J., Weltin, A., Flamm, H., & Urban, G. A. (2018) · Lab on a Chip · doi:10.1039/c7lc00942a · Cited by 198
Shin, W., Hinojosa, C. D., Ingber, D. E., & Kim, H. J. (2019) · iScience · doi:10.1016/j.isci.2019.04.037 · Cited by 186
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Marx, U., Walles, H., Hoffmann, S., Lindner, G., Horland, R., Sonntag, F., Klotzbach, U., Sakharov, D., Tonevitsky, A., & Lauster, R. (2012) · Alternatives to Laboratory Animals · doi:10.1177/026119291204000504 · Cited by 177
Jang, K.-J., Cho, H. S., Kang, D. H., Bae, W. G., Kwon, T.-H., & Suh, K.-Y. (2011) · Integr. Biol. · doi:10.1039/c0ib00018c · Cited by 177
Muscle on a chip: In vitro contractility assays for smooth and striated muscle
Grosberg, A., Nesmith, A. P., Goss, J. A., Brigham, M. D., McCain, M. L., & Parker, K. K. (2012) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2012.04.001 · Cited by 176
Human induced pluripotent stem cells and their use in drug discovery for toxicity testing
Scott, C. W., Peters, M. F., & Dragan, Y. P. (2013) · Toxicology Letters · doi:10.1016/j.toxlet.2013.02.020 · Cited by 174
Riahi, R., Shaegh, S. A. M., Ghaderi, M., Zhang, Y. S., Shin, S. R., Aleman, J., Massa, S., Kim, D., Dokmeci, M. R., & Khademhosseini, A. (2016) · Scientific Reports · doi:10.1038/srep24598 · Cited by 172
Musah, S., Dimitrakakis, N., Camacho, D. M., Church, G. M., & Ingber, D. E. (2018) · Nature Protocols · doi:10.1038/s41596-018-0007-8 · Cited by 167
Ma, L.-D., Wang, Y.-T., Wang, J.-R., Wu, J.-L., Meng, X.-S., Hu, P., Mu, X., Liang, Q.-L., & Luo, G.-A. (2018) · Lab on a Chip · doi:10.1039/c8lc00333e · Cited by 166
Self-citationKang, Y. B. (., Sodunke, T. R., Lamontagne, J., Cirillo, J., Rajiv, C., Bouchard, M. J., & Noh, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25659 · Cited by 165
Tzatzalos, E., Abilez, O. J., Shukla, P., & Wu, J. C. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.010 · Cited by 162 · cited 1×
“[87] reported that the hiPSC-CMs can represent an unlimited potential for healthy and disease-specific CMs to assess the efficacy of drugs for dilated cardiomyopathy.”
BackgroundSelf-citationA microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159
Liver-Kidney-on-Chip To Study Toxicity of Drug Metabolites
Theobald, J., Ghanem, A., Wallisch, P., Banaeiyan, A. A., Andrade-Navarro, M. A., Taškova, K., Haltmeier, M., Kurtz, A., Becker, H., Reuter, S., et al. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00417 · Cited by 157
Physiologically relevant organs on chips
Yum, K., Hong, S. G., Healy, K. E., & Lee, L. P. (2014) · Biotechnology Journal · doi:10.1002/biot.201300187 · Cited by 150
Lu, S., Cuzzucoli, F., Jiang, J., Liang, L.-G., Wang, Y., Kong, M., Zhao, X., Cui, W., Li, J., & Wang, S. (2018) · Lab on a Chip · doi:10.1039/c8lc00852c · Cited by 144
Zhou, Q., Patel, D., Kwa, T., Haque, A., Matharu, Z., Stybayeva, G., Gao, Y., Diehl, A. M., & Revzin, A. (2015) · Lab on a Chip · doi:10.1039/c5lc00874c · Cited by 138
Comparison of Human Induced Pluripotent and Embryonic Stem Cells: Fraternal or Identical Twins?
Narsinh, K. H., Plews, J., & Wu, J. C. (2011) · Molecular Therapy · doi:10.1038/mt.2011.41 · Cited by 135
Self-citationMulti-Organs-on-Chips: Towards Long-Term Biomedical Investigations
Zhao, Y., Kankala, R. K., Wang, S.-B., & Chen, A.-Z. (2019) · Molecules · doi:10.3390/molecules24040675 · Cited by 134
Wang, L., Liu, W., Wang, Y., Wang, J.-C., Tu, Q., Liu, R., & Wang, J. (2013) · Lab Chip · doi:10.1039/c2lc40661f · Cited by 133
The Hepatic Microvascular System in Health and Its Response to Toxicants
Mccuskey, R. S. (2008) · The Anatomical Record · doi:10.1002/ar.20663 · Cited by 128
Progress, obstacles, and limitations in the use of stem cells in organ-on-a-chip models
Wnorowski, A., Yang, H., & Wu, J. C. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.001 · Cited by 124
Self-citationA pumpless multi‐organ‐on‐a‐chip (MOC) combined with a pharmacokinetic–pharmacodynamic (PK–PD) model
Lee, H., Kim, D. S., Ha, S. K., Choi, I., Lee, J. M., & Sung, J. H. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26087 · Cited by 124
Sellgren, K. L., Hawkins, B. T., & Grego, S. (2015) · Biomicrofluidics · doi:10.1063/1.4935594 · Cited by 119
Layered Patterning of Hepatocytes in Co-Culture Systems using Microfabricated Stencils
Cho, C. H., Park, J., Tilles, A. W., Berthiaume, F., Toner, M., & Yarmush, M. L. (2010) · BioTechniques · doi:10.2144/000113317 · Cited by 116
Projection-Based 3D Printing of Cell Patterning Scaffolds with Multiscale Channels
Xue, D., Wang, Y., Zhang, J., Mei, D., Wang, Y., & Chen, S. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03867 · Cited by 116
Stem Cell Culture and Differentiation in Microfluidic Devices Toward Organ-on-a-Chip
Zhang, J., Wei, X., Zeng, R., Xu, F., & Li, X. (2017) · Future Science OA · doi:10.4155/fsoa-2016-0091 · Cited by 115
Incorporating mechanical strain in organs-on-a-chip: Lung and skin
Guenat, O. T., & Berthiaume, F. (2018) · Biomicrofluidics · doi:10.1063/1.5024895 · Cited by 108
Automated microfluidic cell culture of stem cell derived dopaminergic neurons
Kane, K. I. W., Moreno, E. L., Hachi, S., Walter, M., Jarazo, J., Oliveira, M. A. P., Hankemeier, T., Vulto, P., Schwamborn, J. C., Thoma, M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-34828-3 · Cited by 105
Hegde, M., Jindal, R., Bhushan, A., Bale, S. S., McCarty, W. J., Golberg, I., Usta, O. B., & Yarmush, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00071d · Cited by 104
Mimicking Epithelial Tissues in Three-Dimensional Cell Culture Models
Torras, N., García-Díaz, M., Fernández‐Majada, V., & Martínez, E. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00197 · Cited by 101
Introducing an automated high content confocal imaging approach for Organs-on-Chips
Peel, S., Corrigan, A. M., Ehrhardt, B., Jang, K.-J., Caetano-Pinto, P., Boeckeler, M., Rubins, J. E., Kodella, K., Petropolis, D. B., Ronxhi, J., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00829a · Cited by 98
Integration Concepts for Multi-Organ Chips: How to Maintain Flexibility?!
Rogal, J., Probst, C., & Loskill, P. (2017) · Future Science OA · doi:10.4155/fsoa-2016-0092 · Cited by 86
‘Organs-on-chips’ go mainstream
Reardon, S. (2015) · Nature · doi:10.1038/523266a · Cited by 83
Alexander, F. A., Eggert, S., & Wiest, J. (2018) · Genes · doi:10.3390/genes9020114 · Cited by 82
Zhao, M.-T., Chen, H., Liu, Q., Shao, N.-Y., Sayed, N., Wo, H.-T., Zhang, J. Z., Ong, S.-G., Liu, C., Kim, Y., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1708991114 · Cited by 78
Self-citationSchneider, O., Zeifang, L., Fuchs, S., Sailer, C., & Loskill, P. (2019) · Tissue Engineering Part A · doi:10.1089/ten.tea.2019.0002 · Cited by 73
Park, D., Lim, J., Park, J. Y., & Lee, S.-H. (2015) · Stem Cells Translational Medicine · doi:10.5966/sctm.2015-0095 · Cited by 70
Temporal Monitoring of Differentiated Human Airway Epithelial Cells Using Microfluidics
Blume, C., Reale, R., Held, M., Millar, T. M., Collins, J. E., Davies, D. E., Morgan, H., & Swindle, E. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0139872 · Cited by 70
Organ-on-a-Chip: New Platform for Biological Analysis
An, F., Qu, Y., Liu, X., Zhong, R., & Luo, Y. (2015) · Analytical Chemistry Insights · doi:10.4137/aci.s28905 · Cited by 67
A human proximal tubule-on-a-chip to study renal disease and toxicity
Sakolish, C. M., Philip, B., & Mahler, G. J. (2019) · Biomicrofluidics · doi:10.1063/1.5083138 · Cited by 66
Organ-on-a-chip technology: turning its potential for clinical benefit into reality
Haddrick, M., & Simpson, P. B. (2019) · Drug Discovery Today · doi:10.1016/j.drudis.2019.03.011 · Cited by 63
Al‐Lamki, R. S., Bradley, J. R., & Pober, J. S. (2017) · Frontiers in Medicine · doi:10.3389/fmed.2017.00148 · Cited by 59
Zhang, X., Wang, T., Wang, P., & Hu, N. (2016) · Micromachines · doi:10.3390/mi7070122 · Cited by 58
Cardiac Meets Skeletal: What’s New in Microfluidic Models for Muscle Tissue Engineering
Visone, R., Gilardi, M., Marsano, A., Rasponi, M., Bersini, S., & Moretti, M. (2016) · Molecules · doi:10.3390/molecules21091128 · Cited by 56
Microfluidic Gel Patterning Method by Use of a Temporary Membrane for Organ‐On‐Chip Applications
Tibbe, M. P., Leferink, A., van den Berg, A., Eijkel, J. C. T., & Segerink, L. I. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700200 · Cited by 56
RhoA mediates flow-induced endothelial sprouting in a 3-D tissue analogue of angiogenesis
Song, J. W., Daubriac, J., Tse, J. M., Bazou, D., & Munn, L. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40389g · Cited by 54
Heylman, C., Sobrino, A., Shirure, V. S., Hughes, C. C., & George, S. C. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214525295 · Cited by 53
Yildirimer, L., Zhang, Q., Kuang, S., Cheung, C.-W. J., Chu, K. A., He, Y., Yang, M., & Zhao, X. (2019) · Biofabrication · doi:10.1088/1758-5090/ab17aa · Cited by 53
Wang, Y., Huang, X., Shen, Y., Hang, R., Zhang, X., Wang, Y., Yao, X., & Tang, B. H. (2019) · Journal of Materials Science · doi:10.1007/s10853-019-03447-2 · Cited by 50
Conceptual Design of Micro-Bioreactors and Organ-on-Chips for Studies of Cell Cultures
Mandenius, C. (2018) · Bioengineering · doi:10.3390/bioengineering5030056 · Cited by 48
Dabaghi, M., Fusch, G., Saraei, N., Rochow, N., Brash, J. L., Fusch, C., & Selvaganapathy, P. R. (2018) · Biomicrofluidics · doi:10.1063/1.5034791 · Cited by 46
Lee, S. H., & Jun, B. (2018) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2018.11.041 · Cited by 46
Microtechnology-Based Multi-Organ Models
Lee, S., & Sung, J. (2017) · Bioengineering · doi:10.3390/bioengineering4020046 · Cited by 42
Farewell to Animal Testing: Innovations on Human Intestinal Microphysiological Systems
Kang, T., & Kim, H. (2016) · Micromachines · doi:10.3390/mi7070107 · Cited by 40
Yang, S. H., Choi, J. W., Huh, D., Jo, H. A., Kim, S., Lim, C. S., Lee, J. C., Kim, H. C., Kwon, H. M., Jeong, C. W., et al. (2017) · Experimental Cell Research · doi:10.1016/j.yexcr.2017.03.026 · Cited by 39
Microfluidic Technology for Cell Manipulation
Kwon, J., & Oh, J. H. (2018) · Applied Sciences · doi:10.3390/app8060992 · Cited by 36
A liver-immune coculture array for predicting systemic drug-induced skin sensitization
Chong, L. H., Li, H., Wetzel, I., Cho, H., & Toh, Y. (2018) · Lab on a Chip · doi:10.1039/c8lc00790j · Cited by 34
Maturation of Human Stem Cell-derived Cardiomyocytes in Biowires Using Electrical Stimulation
Sun, X., & Nunes, S. S. (2017) · Journal of Visualized Experiments · doi:10.3791/55373 · Cited by 32
Research on the Methods for the Mass Production of Multi-Scale Organs-On-Chips
Lantada, A. D., Pfleging, W., Besser, H., Guttmann, M., Wissmann, M., Plewa, K., Smyrek, P., Piotter, V., & García-Ruiz, J. P. (2018) · Polymers · doi:10.3390/polym10111238 · Cited by 32
Development of Microfluidic Stretch System for Studying Recovery of Damaged Skeletal Muscle Cells
Kim, W., Kim, J.-S., Park, H., & Jeon, J. S. (2018) · Micromachines · doi:10.3390/mi9120671 · Cited by 31
Emerging In Vitro Systems to Screen and Predict Drug-Induced Kidney Toxicity
Nieskens, T. T. G., & Sjogren, A.-K. M. (2019) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2018.12.009 · Cited by 31
Advancements and Potential Applications of Microfluidic Approaches—A Review
Ahmed, I., Akram, Z., Bule, M. H., & Iqbal, H. M. N. (2018) · Chemosensors · doi:10.3390/chemosensors6040046 · Cited by 30
Multi-organ on a chip for personalized precision medicine
Palaninathan, V., Kumar, V., Maekawa, T., Liepmann, D., Paulmurugan, R., Eswara, J. R., Ajayan, P. M., Augustine, S., Malhotra, B. D., Viswanathan, S., et al. (2018) · MRS Communications · doi:10.1557/mrc.2018.148 · Cited by 29
Li, Y., Lin, M.-W., Yen, M.-H., Fan, S. M., Wu, J., Young, T., Cheng, J., & Lin, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b05978 · Cited by 28
Self-citationMicrofluidic-based biomimetic models for life science research
Jiang, K., Dong, C., Xu, Y., & Wang, L. (2016) · RSC Advances · doi:10.1039/c6ra05691a · Cited by 26
Microdevice Platform for In Vitro Nervous System and Its Disease Model
Choi, J., Cho, H., & Choi, J.-W. (2017) · Bioengineering · doi:10.3390/bioengineering4030077 · Cited by 23
Advances in microfluidic platforms for analyzing and regulating human pluripotent stem cells
Qian, T., Shusta, E. V., & Palecek, S. P. (2015) · Current Opinion in Genetics & Development · doi:10.1016/j.gde.2015.07.007 · Cited by 21
Embossed Membranes with Vascular Patterns Guide Vascularization in a 3D Tissue Model
Hong, S., Kang, E. Y., Byeon, J., Jung, S., & Hwang, C. (2019) · Polymers · doi:10.3390/polym11050792 · Cited by 20
Cited by
Induced pluripotent stem cells (iPSCs): molecular mechanisms of induction and applications
Cerneckis, J., Cai, H., & Shi, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01809-0 · Cited by 452
Design Challenges in Polymeric Scaffolds for Tissue Engineering
Echeverria Molina, M. I., Malollari, K. G., & Komvopoulos, K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.617141 · Cited by 397
Pokrajac, L., Abbas, A., Chrzanowski, W., Dias, G. M., Eggleton, B. J., Maguire, S., Maine, E., Malloy, T., Nathwani, J., Nazar, L., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c10919 · Cited by 365
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Precision Medicine: Disease Subtyping and Tailored Treatment
Wang, R. C., & Wang, Z. (2023) · Cancers · doi:10.3390/cancers15153837 · Cited by 315
Metadata
- Authors
- Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X.
- Venue
- BioMedical Engineering OnLine
- Published
- 2020-02-12
- Volume
- 19
- Issue
- 1
- Pages
- 9-9
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W3007262342
- Cited by
- 701
- References
- 129
- FWCI
- 31.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.