An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
The DOI matches its Crossref record, with a small difference in title or year; 26 of the 26 references it cites were found in a registry or an index.
Abstract
An implanted neuroprosthesis supplying functional neuromuscular stimulation was used to provide grasp and release to tetraplegic individuals. This article describes the results, at a minimum of three years, for the first five patients to have operative implantation of an eight-channel stimulator-receiver. All of the patients had a clinically complete spinal cord injury with motor function remaining at the level of the fifth or sixth cervical nerve root. In addition to implantation of the stimulator system, each patient had augmentative operations on the hand to improve function. The procedures included tendon transfers, side-to-side tendon anastomoses, arthrodesis of the interphalangeal joint of the thumb, and rotational osteotomy of the radius. The neuroprosthesis provides two grasp patterns controlled by voluntary motion of the shoulder or wrist. Functional evaluations included measurement of pinch force, a grasp-release test, evaluation of the level of functional independence, and usage surveys. Pinch force ranged from eight to twenty-five newtons. All five patients demonstrated functional grasp patterns, had increased independence, and were able to use the neuroprosthesis at home on a regular basis. The implanted stimulator has proved to be safe and reliable, with seven years as the longest time in situ at the time of writing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“for control of hand movements”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Kilgore, 1997
Citations
Cites
The pacemaker-twiddler's syndrome: a new complication of implantable transvenous pacemakers.
Bayliss, C. E., Beanlands, D. S., & Baird, R. J. (1968) · PubMed Central · Cited by 315
Moberg, E. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557020-00012 · Cited by 308
Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325979 · Cited by 281
Self-citationImplantable functional neuromuscular stimulation in the tetraplegic hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Stroh, K. C., Smith, B., Buckett, J. R., Kilgore, K. L., & Jatich, J. W. (1989) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(89)80017-6 · Cited by 212
Self-citationWuolle, K. S., Van Doren, C. L., Thrope, G. B., Keith, M. W., & Peckham, P. H. (1994) · The Journal of Hand Surgery · doi:10.1016/0363-5023(94)90008-6 · Cited by 198
Self-citationMcDowell, C. L., Moberg, E. A., & House, J. H. (1986) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(86)80213-1 · Cited by 198
Moberg, E., L. McDowell, C., & H. House, J. (1989) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(89)80064-4 · Cited by 178
Synthesis of hand grasp using functional neuromuscular stimulation
Kilgore, K. L., Peckham, P. H., Thrope, G. B., Keith, M. W., & Gallaher-Stone, K. A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32109 · Cited by 152
Self-citationPeckham, P. H., Mortimer, J. T., & Marsolais, E. B. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363440 · Cited by 145
Self-citationPeckham, P. H., Keith, M. W., & Freehafer, A. A. (1988) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198870010-00027 · Cited by 136
Self-citation
Research works printed but not linked: 4
- Bayliss, 1968, Canadian Med Assn J, 99, 371
- Handa, 1989, Automedica, 11, 221
- Kilgore, 1995, J Spinal Cord Med, 18, 147
- Wijman, 1990, Arch Phys Med and Rehab, 71, 1053
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485
Brain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Self-citationSmith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Self-citationAn Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, K. L., Hoyen, H. A., Bryden, A. M., Hart, R. L., Keith, M. W., & Peckham, P. H. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2008.01.007 · Cited by 189
Self-citationPopovic, M. R., Popovic, D. B., & Keller, T. (2002) · Neurological Research · doi:10.1179/016164102101200311 · Cited by 155
“shoulder position sensor (see Figure 2) [12,17].”
Mangold, S., Keller, T., Curt, A. E. P., & Dietz, V. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101644 · Cited by 143
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
“In these systems, activation of each muscle requires at least one electrode [6], [7].”
Self-citationA comparison between control methods for implanted FES hand-grasp systems
Hart, R. L., Kilgore, K. L., & Peckham, P. H. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681187 · Cited by 128
Self-citationApplications of cortical signals to neuroprosthetic control: a critical review
Lauer, R. T., Peckham, P. H., Kilgore, K. L., & Heetderks, W. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847817 · Cited by 120
Self-citationPrediction of upper limb muscle activity from motor cortical discharge during reaching
Pohlmeyer, E. A., Solla, S. A., Perreault, E. J., & Miller, L. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/003 · Cited by 118
Peckham, P. H., Kilgore, K. L., Keith, M. W., Bryden, A. M., Bhadra, N., & Montague, F. W. (2002) · The Journal Of Hand Surgery · doi:10.1053/jhsu.2002.30919 · Cited by 123
Self-citationTarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
A pilot study of myoelectrically controlled FES of upper extremity
Thorsen, R., Spadone, R., & Ferrarin, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928576 · Cited by 106
“, Valley View, OH, USA [7].”
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Clinical Applications of Electrical Stimulation After Spinal Cord Injury
Creasey, G. H., Ho, C. H., Triolo, R. J., Gater, D. R., DiMarco, A. F., Bogie, K. M., & Keith, M. W. (2004) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2004.11753774 · Cited by 102
Self-citationMulcahey, M. J., Lutz, C. S., Kozin, S. H., & Betz, R. R. (2003) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(03)00485-4 · Cited by 95
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
“We have developed two generations of implantable neuroprosthetic systems, which were used initially to provide hand grasping function in cervical spinal cord injury [13], and more recently to provide standing and stepping function in thoracic spinal cord injury [16].”
BackgroundMethodSelf-citationLocal field potentials allow accurate decoding of muscle activity
Flint, R. D., Ethier, C., Oby, E. R., Miller, L. E., & Slutzky, M. W. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00832.2011 · Cited by 91
“Implanted clinical FES systems such as the Freehand (Kilgore et al. 1997) are currently restricted to the use of residual movement and the activity of muscles in the shoulder or neck to control stimulation.”
BackgroundWalking after incomplete spinal cord injury using an implanted FES system: A case report
Hardin, E., Kobetic, R., Murray, L., Corado-Ahmed, M., Pinault, G., Sakai, J., Nogan Bailey, S., Ho, C., & Triolo, R. J. (2007) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.03.0333 · Cited by 90
“Fully implanted pacemaker-like systems, on the other hand, offer numerous advantages over surface and percutaneous stimulation for long-term clinical use, including improved convenience, cosmesis, reliability, and repeatability [26].”
BackgroundPersons with C5 or C6 tetraplegia achieve selected functional gains using a neuroprosthesis
Alon, G., & McBride, K. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50073 · Cited by 80
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2_1 · Cited by 77
Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes
Akers, J. M., Peckham, P. H., Keith, M. W., & Merritt, K. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.593301 · Cited by 77
Self-citationChae, J., & Hart, R. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199811000-00013 · Cited by 72
Self-citationSatisfaction with and usage of a hand neuroprosthesis
Wuolle, K. S., Van Doren, C. L., Bryden, A. M., Hunter Peckham, P., Keith, M. W., Kilgore, K. L., & Grill, J. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90123-5 · Cited by 70
Self-citationChapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Assessment of upper limb in tetraplegia: Considerations in evaluation and outcomes research
Mulcahey, M. J., Hutchinson, D., & Kozin, S. H. (2007) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.10.0167 · Cited by 73
Wuolle, K. S., Bryden, A. M., Peckham, P. H., Murray, P. K., & Keith, M. W. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00292-2 · Cited by 77
Self-citationSurgical Technique for Installing an Eight-Channel Neuroprosthesis for Standing
Davis, J. A., Triolo, R. J., Uhlir, J. P., Bhadra, N., Lissy, D. A., Nandurkar, S., & Marsolais, E. B. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200104000-00035 · Cited by 68
Implantable transducer for two-degree of freedom joint angle sensing
Johnson, M. W., Peckham, P. H., Bhadra, N., Kilgore, K. L., Gazdik, M. M., Keith, M. W., & Strojnik, P. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788471 · Cited by 65
Self-citationDesign and Testing of an Advanced Implantable Neuroprosthesis With Myoelectric Control
Hart, R. L., Bhadra, N., Montague, F. W., Kilgore, K. L., & Peckham, P. H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2079952 · Cited by 66
Self-citationFunctional reorganization of upper-body movement after spinal cord injury
Casadio, M., Pressman, A., Fishbach, A., Danziger, Z. C., Acosta, S., Chen, D., Tseng, H.-Y., & Mussa-Ivaldi, F. A. (2010) · Experimental Brain Research · doi:10.1007/s00221-010-2427-8 · Cited by 60
Lemay, M. A., Calagan, J. E., Hogan, N., & Bizzi, E. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918272 · Cited by 58
Knutson, J. S., Naples, G. G., Peckham, P. H., & Keith, M. W. (2002) · PubMed · Cited by 51
Self-citationThe function of the finger intrinsic muscles in response to electrical stimulation
Lauer, R. T., Kilgore, K. L., Peckham, P. H., Bhadra, N., & Keith, M. W. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750547 · Cited by 50
Self-citationBody machine interface: Remapping motor skills after spinal cord injury
Casadio, M., Pressman, A., Acosta, S., Danzinger, Z., Fishbach, A., Mussa-Ivaldi, F. A., Muir, K., Tseng, H.-Y., & Chen, D. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975384 · Cited by 51
Reduction of Costs of Disability Using Neuroprostheses
Creasey, G. H., Kilgore, K. L., Brown-Triolo, D. L., Dahlberg, J. E., Peckham, P. H., & Keith, M. W. (2000) · Assistive Technology · doi:10.1080/10400435.2000.10132010 · Cited by 46
Self-citationReciprocal EMG control of elbow extension by FES
Giuffrida, J. P., & Crago, P. E. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.1000113 · Cited by 50
Herring, E. Z., Graczyk, E. L., Memberg, W. D., Adams, R., Baca-Vaca, G. F., Hutchison, B. C., Krall, J. T., Alexander, B. J., Conlan, E. C., Alfaro, K. E., et al. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002769 · Cited by 49
“FES has been used for many years to activate paralyzed muscles in people with neurological de fi cits, 5,6 both in the lower (standing/transfer/walking functions 8,9 ) and upper (reaching/ grasping functions 6,7,31 ) extremities.”
Koch, J., Schuettler, M., Pasluosta, C., & Stieglitz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36df · Cited by 43
Repair and Neurorehabilitation Strategies for Spinal Cord Injury
Ruff, R. L., McKerracher, L. J., & Selzer, M. E. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1444.004 · Cited by 53
OrthoJacket: an active FES-hybrid orthosis for the paralysed upper extremity
Schill, O., Wiegand, R., Schmitz, B., Matthies, R., Eck, U., Pylatiuk, C., Reischl, M., Schulz, S., & Rupp, R. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.056 · Cited by 47
Meiners, T., Abel, R. F., Lindel, K., & Mesecke, U. (2002) · Spinal Cord · doi:10.1038/sj.sc.3101384 · Cited by 41
Bryden, A. M., Sinnott, A., & Mulcahey, M. J. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/ln94-nmvk-59v3-cc1f · Cited by 40
Self-citationRestoration of elbow extension via functional electrical stimulation in individuals with tetraplegia
Memberg, W. D., Crago, P. E., & Keith, M. W. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.11.0477 · Cited by 41
“Individuals who are candidates for triceps stimulation generally are already receiving a hand-grasp neuroprosthesis [18].”
BackgroundSelf-citationImplantation of a 16-Channel Functional Electrical Stimulation Walking System
Sharma, M., Marsolais, E. B., Polando, G., Triolo, R. J., Davis, J. A., Bhadra, N., & Uhlir, J. P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199802000-00029 · Cited by 37
Implanted neuroprosthesis for assisting arm and hand function after stroke: A case study
Knutson, J. S., Chae, J., Hart, R. L., Keith, M. W., Hoyen, H. A., Harley, M. Y., Hisel, T. Z., Bryden, A. M., Kilgore, K. L., & Peckham, P. H. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.09.0171 · Cited by 35
“The stimulating and EMG-recording electrodes and IST were implanted according to procedures described in detail elsewhere [4,13–14].”
MethodSelf-citationBryden, A. M., Memberg, W. D., & Crago, P. E. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(00)90226-0 · Cited by 38
Self-citationIntegrated CMOS Amplifier for ENG Signal Recording
Uranga, A., Navarro, X., & Barniol, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834253 · Cited by 37
Lower extremity applications of functional neuromuscular stimulation after spinal cord injury
Triolo, R., & Bogie, K. (1999) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/uxue-5l1r-wkkv-1rgp · Cited by 34
Tigra, W., Dali, M., William, L., Fattal, C., Gélis, A., Divoux, J., Coulet, B., Teissier, J., Guiraud, D., & Coste, C. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00676-4 · Cited by 37
Neuroprosthetic devices: how far are we from recovering movement in paralyzed patients?
Pancrazio, J. J., & Peckham, P. H. (2009) · Expert Review of Neurotherapeutics · doi:10.1586/ern.09.12 · Cited by 35
Self-citationAn Update on Functional Electrical Stimulation after Spinal Cord Injury
Gorman, P. H. (2000) · Neurorehabilitation and neural repair · doi:10.1177/154596830001400402 · Cited by 32
An artificial grasping evaluation system for the paralysed hand
Castro, M. C. F., & Cliquet, A. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347047 · Cited by 32
Prediction of muscle activity during loaded movements of the upper limb
Tibold, R., & Fuglevand, A. J. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-6 · Cited by 33
“individuals [1-16].”
Variations in Innervation of the Flexor Digitorum Profundus Muscle
Bhadra, N., Keith, M. W., & Peckham, P. H. (1999) · The Journal Of Hand Surgery · doi:10.1053/jhsu.1999.0700 · Cited by 29
Self-citationAustralian Experience with the Freehand System®for Restoring Graspin Quadriplegia
Carroll, S., Coope, C., Brown, D., Sormann, G. W., Flood, S. J., & Denison., M. L. (2000) · Australian and New Zealand Journal of Surgery · doi:10.1046/j.1440-1622.2000.01899.x · Cited by 29
Effectiveness of supplemental grasp-force feedback in the presence of vision
Zafar, M., & Doren, C. L. V. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347046 · Cited by 29
“, 1992), or neuroprostheses (KEITH et al., 1989; HANDA et al., 1992; NATHAN, 1993; KILGORE et al., 1997; Prochazka et al., 1997; for a review see TRIOLO et al., 1996), but none of these treatments compensates for the loss of proprioceptive and tactile sensation that accompanies paralysis.”
BackgroundQu, H., Xie, Y., Liu, X., He, X., Hao, M., Bao, Y., Xie, Q., & Lan, N. (2016) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.10.0227 · Cited by 30
Murray, W. M., Bryden, A. M., Kilgore, K. L., & Keith, M. W. (2002) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200212000-00012 · Cited by 28
Self-citationIn vivo determination of available brachioradialis excursion during tetraplegia reconstruction
Kozin, S. H., & Bednar, M. S. (2001) · The Journal Of Hand Surgery · doi:10.1053/jhsu.2001.24970 · Cited by 27
Artificial Grasping System for the Paralyzed Hand
Castro, M. C. F., & Cliquet, A. (2000) · Artificial Organs · doi:10.1046/j.1525-1594.2000.06524.x · Cited by 31
Gant, K. L., Guerra, S., Zimmerman, L., Parks, B. A., Prins, N. W., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabb13 · Cited by 28
Artificial Organs and Vanishing Boundaries
Malchesky, P. S. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025002075.x · Cited by 27
Neuroprostheses for the upper extremity
Keith, M. W. (2001) · Microsurgery · doi:10.1002/micr.1049 · Cited by 27
Self-citationIndications and future directions for upper limb neuroprostheses in tetraplegic patients: a review
Keith, M. W., & Hoyen, H. A. (2002) · Hand Clinics · doi:10.1016/s0749-0712(02)00034-3 · Cited by 23
“Furthermore, the strength is immediate; rehabilitation is rapid and persists over the follow-up period [11].”
BackgroundSelf-citationImplanted Neuroprostheses for Restoration of Hand Function in Tetraplegic Patients
Cornwall, R., & Hausman, M. R. (2004) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200403000-00002 · Cited by 26
Kilgore, K. L., Bryden, A. M., Keith, M. W., Hoyen, H. A., Hart, R. L., Nemunaitis, G. A., & Peckham, P. H. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2403-252 · Cited by 29
Self-citationKalsi‐Ryan, S., & Verrier, M. C. (2011) · Physiotherapy Canada · doi:10.3138/ptc.2009-46 · Cited by 27
Twenty year experience with implanted neuroprostheses
Kilgore, K. L., Peckham, P. H., & Keith, M. W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335272 · Cited by 24
Self-citationCoste, C., William, L., da Fonseca, L. O., Hiairrassary, A., Andreu, D., Geffrier, A., Teissier, J., Fattal, C., & Guiraud, D. (2022) · Scientific Reports · doi:10.1038/s41598-022-19906-x · Cited by 31
Évolution de la prise en charge chirurgicale du membre supérieur tétraplégique depuis 50 ans
Fattal, C., Teissier, J., Leclercq, C., Revol, M. P., & Enjalbert, M. (2003) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/s0168-6054(03)00014-x · Cited by 20
Biomechatronics – Assisting the Impaired Motor System
Veltink, P. H., Koopman, H. F. J. M., van der Helm, F. C. T., & Nene, A. V. (2001) · Archives of Physiology and Biochemistry · doi:10.1076/apab.109.1.1.4282 · Cited by 23
“Of course, this is not an option for prosthetic systems which substitute a missing part of a limb, but can be considered for FES systems (Thoma et al., 1983; Cameron et al., 1997; Donaldson et al., 1997a; Donaldson et al., 1997b; Kilgore et al., 1997; Smith et al., 1998).”
BackgroundElectrical Stimulation of the Neuromuscular System
Durand, D. M., Grill, W. M., & Kirsch, R. F. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_5 · Cited by 24
“This electrode has been used in an implanted hand grasp neuroprosthesis (Grandjean and Mortimer, 1986; Smith et al., 1987; Keith et al., 1989; Kilgore et al., 1997) and in lower extremity systems (Triolo et ai, 1996a,b).”
MethodConcepts and Methods in Neuromodulation and Functional Electrical Stimulation: An Introduction
Holsheimer, J. (1998) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.1998.tb00018.x · Cited by 25
Triolo, R. J., Bailey, S. N., Foglyano, K. M., Kobetic, R., Lombardo, L. M., Miller, M. E., & Pinault, G. C. J. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.08.470 · Cited by 19
“This is consistent with previous reports of the stability of all eight electrodes in one participant with an UE NP utilizing the same technology after nine years [37].”
Functional Neuromuscular Stimulation in Spinal Cord Injury
Chae, J., Kilgore, K. L., Triolo, R. J., & Creasey, G. H. (2000) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(18)30155-4 · Cited by 21
Self-citationFattal, C., & Leblond, C. (2005) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2005.03.006 · Cited by 18
“D’autres tests proposés dans le même cadre de chirurgie du membre supérieur tétraplégique, sont administrés en simple observation ou soumis en questionnaire et sont confinés dans le cadre restreint de leurs concepteurs qui en sont les uniques utilisateurs [32,33] : Hand and Arm Function test [89], le COT — Common obje…”
BackgroundSelf-Reported Use of an Implanted FES Hand System by Adolescents with Tetraplegia
Davis, S. E., Mulcahey, M. J., Smith, B. T., & Betz, R. R. (1998) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.1998.11719530 · Cited by 18
Kilgore, K. L., Hart, R. L., Montague, F. W., Bryden, A. M., Keith, M. W., Hoyen, H. A., Sams, C. J., & Peckham, P. H. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259939 · Cited by 20
Self-citationKnutson, J. S., Hoyen, H. A., Kilgore, K. L., & Peckham, P. H. (2004) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.04.0053 · Cited by 20
“The implantable neuroprosthetic handgrasp system developed at the Cleveland Department of Veterans Affairs (VA) Medical Center and Case Western Reserve University [2,3] provides palmar and lateral pinch, enabling users to grasp, hold, and release objects.”
MethodSelf-citationKozin, S. H. (2002) · Journal of the American Society for Surgery of the Hand · doi:10.1053/jssh.2002.34792 · Cited by 17
Bryden, A. M., Kilgore, K. L., Keith, M. W., & Peckham, P. H. (2008) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1304-37 · Cited by 18
Self-citationThe Syndrome of Spastic Paresis
Dietz, V., & Young, R. R. (2003) · Elsevier eBooks · doi:10.1016/b978-012125831-3/50282-3 · Cited by 20
DESIGN PRINCIPLES OF A NEUROMOTOR PROSTHETIC DEVICE
Serruya, M. D., & Donoghue, J. P. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0040 · Cited by 21
Brain–Computer Interface—FES Integration: Towards a Hands‐free Neuroprosthesis Command System
Boord, P., Barriskill, A., Craig, A., & Nguyen, H. (2004) · Neuromodulation (Malden, Mass.) · doi:10.1111/j.1094-7159.2004.04212.x · Cited by 20
An implantable upper extremity neuroprosthesis in a growing child with a C5 spinal cord injury
Smith, B., Mulcahey, M. J., & Betz, R. (2001) · Spinal Cord · doi:10.1038/sj.sc.3101123 · Cited by 16
An Implanted Upper Extremity Neuroprosthesis Utilizing Myoelectric Control
Kilgore, K. L., Peckham, P. H., Montague, F. W., Hart, R. L., Bryden, A. M., Keith, M. W., Hoyen, H. A., & Bhadra, N. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419634 · Cited by 15
Self-citationA Neuroprosthesis for High Tetraplegia
Yu, D., Kirsch, R. F., Bryden, A. M., Memberg, W. D., & Acosta, A. M. (2001) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2001.11753565 · Cited by 15
Self-citationFattal, C. (2003) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2003.08.001 · Cited by 14
“L’ADL test (Activities of Daily Living Test) Il a été décrit de façon très synthétique par Kilgore en vue de l’évaluation des résultats de l’implantation d’une neuroprothèse de stimulation du membre supérieur [78].”
BackgroundInfluentialRehabilitation of the Hand and Upper Extremity in Tetraplegia
Peljovich, A. E., Bryden, A. M., Malone, K. J., Hoyen, H. A., Hernandez-Gonzalez, E., & Keith, M. W. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-05602-1.00132-x · Cited by 16
Self-citationWang, Z., Wang, H., Bi, Z.-Y., Zhou, Y. C., Zhou, Y., & Lv, X. (2016) · Neural Regeneration Research · doi:10.4103/1673-5374.197139 · Cited by 14
“Many novel FES systems have been designed as surface or implantable stimulation systems for controlling arms and hands (Saxena et al., 1995; Ijzerman et al., 1996; Kilgore et al., 1997; Knutson et al., 2012; Hara et al., 2013).”
BackgroundRestoration of Upper Extremity Function in Tetraplegia
Peckham, P. H., Keith, M. W., & Kilgore, K. L. (1999) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/uckb-nvgc-g71t-hjew · Cited by 15
Self-citationElectrical Activation of Spinal Neural Circuits: Application to Motor-System Neural Prostheses
Grill, W. M. (2000) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2000.00097.x · Cited by 14
“Furthermore, movements(2) including hand grasp and release(7), methods must be developed to coordinate artifistanding(8–10), stepping (11,12), and overhead cially the timing and levels of muscle contractions to produce functional movements.”
BackgroundKnutson, J. S., Audu, M. L., & Triolo, R. J. (2006) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/9uu4-kl3v-cpl2-q7vf · Cited by 17
Metadata
- Authors
- KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L.
- Affiliations
- Case Western Reserve University (US)
- MetroHealth Medical Center (US)
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1997-04
- Volume
- 79
- Issue
- 4
- Pages
- 533-41
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W34364292
- Semantic Scholar
- 1fd9809258e6624b00cc50820fc7aa74a50acf2e
- Cited by
- 192
- References
- 26
- Citations by year
- 2026: 3 · 2023: 4 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 4 · 2014: 9 · 2013: 7 · 2012: 7
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Food and Drug Administration (FD000832)
- National Center for Research Resources (M01RR000080, M01RR00080-31)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- upper limb prosthesis, tetraplegia, spinal cord injury, neuromuscular electrical stimulation, grasp and release, tendon transfer, pinch strength, functional independence, long-term follow-up
- MeSH terms
- Activities of Daily Living, Adult, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Quadriplegia, Hand Strength, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.