Fully Integrated Artificial Pancreas in Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9-10 mmol/L. The CLC system was fully integrated using automated data transfer CGM→algorithm→CSII. All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 mmol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The integrated closed-loop systems tested so far have reported favourable results;97”
From Type 1 diabetes (2014) · cites this paper as [97]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · cited 1×
“The control algorithms used by studies 1 and 2—sCTR and eCTR, respectively—were designed and tested in silico using computer simulation (26), and each algorithm had a different focus: in study 1, the”
MethodSelf-citationArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600 · cited 3×
“The rationale behind MPC was presented in detail in a recent review (7).”
BackgroundMethodSelf-citationAbnormal patterns of insulin secretion in non-insulin-dependent diabetes mellitus.
Polonsky, K. S., Given, B. D., Hirsch, L. J., Tillil, H., Shapiro, E. T., Beebe, C., Frank, B. H., Galloway, J. A., & Van Cauter, E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181903 · Cited by 567 · cited 1×
“Diabetes 61:2230–2237, 2012 The maintenance of close-to-normal blood glucose (BG) levels slows the onset and progression of long-term microvascular complications in patients with type 1 diabetes (1); therefore, the ultimate therapeutic goal of type 1 diabetes is to restore near normoglycemia (2).”
BackgroundWeinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Self-citationFeasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473 · cited 1×
“The development of both CGM and portable devices for continuous subcutaneous insulin infusion (CSII) incited the implementation of subcutaneous CLC systems (13).”
BackgroundHovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450 · cited 2×
“Previous studies report significant increase in time within target overnight (15) and reduction in glucose variability as shown by a recent across-trial meta-analysis (35).”
Background
Research works printed but not linked: 1
- Renard EM Farret A Place J Cobelli C Kovatchev BP Breton MD Closed-loop insulin delivery using subcutaneous infusion and glucose sensing, and equipped with a dedicated safety supervision algorithm, improves safety of glucose control in type 1 diabetes. Diabetologia 2010; 53(Suppl. 1): S25
Cited by
Items 101–200 of 354
Zisser, H., Renard, E., Kovatchev, B., Cobelli, C., Avogaro, A., Nimri, R., Magni, L., Buckingham, B. A., Chase, H. P., Doyle, F. J., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0066 · Cited by 48
Self-citationOvernight glucose control in people with type 1 diabetes
Boiroux, D., Duun‐Henriksen, A. K., Schmidt, S., Nørgaard, K., Madsbad, S., Poulsen, N. K., Madsen, H., & Jørgensen, J. B. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.08.005 · Cited by 56
Adaptive personalized multivariable artificial pancreas using plasma insulin estimates
Hajizadeh, I., Rashid, M. M., Samadi, S., Sevil, M., Hobbs, N., Brandt, R., & Çınar, A. (2019) · Journal of Process Control · doi:10.1016/j.jprocont.2019.05.003 · Cited by 56
Dexcom G4AP: An Advanced Continuous Glucose Monitor for the Artificial Pancreas
Garcia, A., Rack-Gomer, A. L., Bhavaraju, N. C., Hampapuram, H., Kamath, A., Peyser, T., Facchinetti, A., Zecchin, C., Sparacino, G., & Cobelli, C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700604 · Cited by 47
Self-citationGarcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Self-citationSchiavon, M., Man, C. D., Kudva, Y. C., Basu, A., & Cobelli, C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700606 · Cited by 52
Self-citationInfluences on Technology Use and Efficacy in Type 1 Diabetes
Franklin, V. L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816639315 · Cited by 52
Michou, P., Gkiourtzis, Ν., Christoforidis, A., Kotanidou, E. P., & Galli-Tsinopoulou, A. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110678 · Cited by 51
Wearable systems and mobile applications for diabetes disease management
Georga, E. I., Protopappas, V. C., Bellos, C. V., & Fotiadis, D. I. (2014) · Health and Technology · doi:10.1007/s12553-014-0082-y · Cited by 53
Reddy, M., Herrero, P., El-Sharkawy, M., Pesl, P., Jugnee, N., Pavitt, D. V., Godsland, I. F., Alberti, K. G. M. M., Toumazou, C., Johnston, D. G., et al. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815616134 · Cited by 51
Blood glucose level prediction based on support vector regression using mobile platforms
Reymann, M. P., Dorschky, E., Groh, B. H., Martindale, C., Blank, P., & Eskofier, B. M. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591358 · Cited by 40
Turksoy, K., Littlejohn, E., & Çınar, A. (2018) · IEEE Control Systems · doi:10.1109/mcs.2017.2766326 · Cited by 48
Psychosocial impact of the bionic pancreas during summer camp
Weissberg-Benchell, J., Hessler, D., Polonsky, W. H., & Fisher, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640289 · Cited by 47
The changing landscape of automated insulin delivery in the management of type 1 diabetes
Lakshman, R., Boughton, C. K., & Hovorka, R. (2023) · Endocrine Connections · doi:10.1530/ec-23-0132 · Cited by 49
Evaluating the Accuracy and Large Inaccuracy of Two Continuous Glucose Monitoring Systems
Leelarathna, L., Nodale, M., Allen, J. M., Elleri, D., Kumareswaran, K., Haidar, A., Caldwell, K., Wilinska, M. E., Acerini, C. L., Evans, M. L., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0245 · Cited by 43
Multicenter Closed-Loop/Hybrid Meal Bolus Insulin Delivery with Type 1 Diabetes
Chase, H. P., Doyle, F. J., Zisser, H., Renard, É., Nimri, R., Cobelli, C., Buckingham, B. A., Maahs, D. M., Anderson, S. M., Magni, L., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0050 · Cited by 47
Self-citationMarçal, D. F. D. S., Alexandrino, E. G., Cortez, L. E. R., & Bennemann, R. M. (2018) · journal of physical education · doi:10.4025/jphyseduc.v29i1.2917 · Cited by 50
Postprandial glucose fluxes and insulin sensitivity during exercise: A study in healthy individuals
Schiavon, M., Hinshaw, L., Mallad, A., Man, C. D., Sparacino, G., Johnson, M., Carter, R., Basu, R., Kudva, Y., Cobelli, C., et al. (2013) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00182.2013 · Cited by 45
Self-citationIacovacci, V., Ricotti, L., Dario, P., & Menciassi, A. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2327196 · Cited by 42
A cyber-physical system approach to artificial pancreas design
Ghorbani, M., & Bogdan, P. (2013) · International Conference on Hardware/Software Codesign and System Synthesis · doi:10.1109/codes-isss.2013.6659004 · Cited by 43
Overcoming barriers in clinical islet transplantation: Current limitations and future prospects
Chhabra, P., Sutherland, D. E. R., & Brayman, K. L. (2013) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2013.10.002 · Cited by 45
Closed loop insulin delivery in diabetes
Battelino, T., Omladič, J. Š., & Phillip, M. (2015) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2015.03.001 · Cited by 42
Model-Based Closed-Loop Glucose Control in Type 1 Diabetes: The DiaCon Experience
Schmidt, S., Boiroux, D., Duun-Henriksen, A. K., Frøssing, L., Skyggebjerg, O., Jørgensen, J. B., Poulsen, N. K., Madsen, H., Madsbad, S., & Nørgaard, K. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700515 · Cited by 35
In Silico Closed-Loop Control Validation Studies for Optimal Insulin Delivery in Type 1 Diabetes
Zavitsanou, S., Mantalaris, A., Georgiadis, M. C., & Pistikopoulos, E. N. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2427991 · Cited by 41
Technology to Optimize Pediatric Diabetes Management and Outcomes
Markowitz, J. T., Harrington, K. R., & Laffel, L. M. (2013) · Current Diabetes Reports · doi:10.1007/s11892-013-0419-3 · Cited by 41
Dai, X., Luo, Z.-C., Zhai, L., Zhao, W., & Huang, F. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0436-y · Cited by 41
Insight into continuous glucose monitoring: from medical basics to commercialized devices
Chmayssem, A., Nadolska, M., Tubbs, E., Sadowska, K., Vadgma, P., Shitanda, I., Tsujimura, S., Lattach, Y., Peacock, M., Tingry, S., et al. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05743-w · Cited by 40
Closed loop developments to improve glucose control at home
Renard, É., Cobelli, C., & Kovatchev, B. P. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.09.009 · Cited by 40
Self-citationAn electrochemical mass sensor for diagnosing diabetes in human serum
Singh, V., & Krishnan, S. (2013) · The Analyst · doi:10.1039/c3an01542d · Cited by 40
Amer, B. E., Yaqout, Y. E., Abozaid, A. M., Afifi, E., & Aboelkhier, M. M. (2023) · Diabetic Medicine · doi:10.1111/dme.15196 · Cited by 40
Kovatchev, B. P. (2012) · Scientifica · doi:10.6064/2012/283821 · Cited by 39
Self-citationImproving Glucose Prediction Accuracy in Physically Active Adolescents With Type 1 Diabetes
Hobbs, N., Hajizadeh, I., Rashid, M. M., Turksoy, K., Breton, M. D., & Çınar, A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818820550 · Cited by 38
Self-citationAutomated Insulin Delivery Algorithms
Çınar, A. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0100 · Cited by 37
Sparacino, G., Zanon, M., Facchinetti, A., Zecchin, C., Maran, A., & Cobelli, C. (2012) · Sensors · doi:10.3390/s121013753 · Cited by 37
Self-citationArtificial pancreas: fuzzy logic and control of glycemia
Nimri, R., & Phillip, M. (2014) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000073 · Cited by 37
Multivariable Adaptive Artificial Pancreas System in Type 1 Diabetes
Çınar, A. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0920-1 · Cited by 37
Integral Backstepping Based Automated Control of Blood Glucose in Diabetes Mellitus Type 1 Patients
Babar, S. A., Ahmad, I., Arslan, M., & Zafar, M. W. (2019) · IEEE Access · doi:10.1109/access.2019.2951010 · Cited by 37
“The controller calculates the required amount of insulin and forward the signal to insulin pump if insulin infusion is required [5].”
BackgroundZisser, H., Dassau, E., Lee, J. J., Harvey, R. A., Bevier, W., & Doyle, F. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815582061 · Cited by 34
Self-citationCapel, I., Rigla, M., García-Sáez, G., Rodríguez-Herrero, A., Pons, B., Subías, D., García-García, F., Gallach, M., Aguilar, M., Pérez-Gandía, C., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0229 · Cited by 29
Metabolic Management during Critical Illness: Glycemic Control in the ICU
Inzucchi, S. E., & Honiden, S. (2015) · Seminars in Respiratory and Critical Care Medicine · doi:10.1055/s-0035-1565253 · Cited by 36
Use of Wearable Sensors and Biometric Variables in an Artificial Pancreas System
Turksoy, K., Monforti, C., Park, M., Griffith, G., Quinn, L., & Çınar, A. (2017) · Sensors · doi:10.3390/s17030532 · Cited by 36
Hypo- and Hyperglycemic Alarms: Devices and Algorithms
Howsmon, D. P., & Bequette, B. W. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815583507 · Cited by 37
A cyber-physical system approach to artificial pancreas design
Ghorbani, M., & Bogdan, P. (2013) · International Conference on Hardware/Software Codesign and System Synthesis · doi:10.5555/2555692.2555709 · Cited by 34
Recent trends and techniques of blood glucose level prediction for diabetes control
Ahmed, B. M., Ali, M. E., Masud, M. M., & Naznin, M. (2024) · Smart Health · doi:10.1016/j.smhl.2024.100457 · Cited by 34
Colmegna, P. H., Sánchez‐Peña, R., Gondhalekar, R., Dassau, E., & Doyle, F. J. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816638857 · Cited by 34
Self-citationFabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes
Du, X., Durgan, C. J., Matthews, D. J., Motley, J. R., Tan, X., Pholsena, K., Árnadóttir, L., Castle, J. R., Jacobs, P. G., Cargill, R. S., et al. (2015) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0101504jss · Cited by 32
Thabit, H., Elleri, D., Leelarathna, L., Allen, J. M., Lubina-Solomon, A., Stadler, M., Walkinshaw, E., Iqbal, A., Choudhary, P., Wilinska, M. E., et al. (2015) · Diabetes Obesity and Metabolism · doi:10.1111/dom.12427 · Cited by 31
“…and children with type 1 diabetes have reported improvements in overnight glucose control whilst reducing the risk of nocturnal hypoglycaemia [7–9] and transitional studies, characterized by close monitoring in diabetes camp and hotel settings, have paved the way for closed-loop system use in…”
BackgroundMultivariable Recursive Subspace Identification with Application to Artificial Pancreas Systems
Hajizadeh, I., Rashid, M. M., Turksoy, K., Samadi, S., Feng, J., Sevil, M., Frantz, N., Lazaro, C., Maloney, Z., Littlejohn, E., et al. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.268 · Cited by 31
Copp, D. A., Gondhalekar, R., & Hespanha, J. P. (2017) · Optimal Control Applications and Methods · doi:10.1002/oca.2388 · Cited by 32
Automated Insulin Delivery Systems as a Treatment for Type 2 Diabetes Mellitus: A Review
Karol, A. B., O’Malley, G., Fallurin, R., & Levy, C. J. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.10.001 · Cited by 31
Islet transplantation-immunological challenges and current perspectives
Kabakchieva, P., Assyov, Y. S., Gerasoudis, S., Vasilev, G., Peshevska-Sekulovska, M., Sekulovski, M., Lazova, S., Miteva, D., Gulinac, M., Tomov, L., et al. (2023) · World Journal of Transplantation · doi:10.5500/wjt.v13.i4.107 · Cited by 31
Gondhalekar, R., Dassau, E., & Doyle, F. J. (2014) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2014.6859247 · Cited by 30
Self-citationQuemerais, M. A., Doron, M., Dutrech, F., Melki, V., Franc, S., Antonakios, M., Charpentier, G., Hanaire, H. P., Benhamou, P., Charpentier, G., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814545668 · Cited by 30
Redij, R., Kaur, A., Muddaloor, P., Sethi, A. K., Aedma, K., Rajagopal, A., Gopalakrishnan, K., Yadav, A., Damani, D. N., Chedid, V. G., et al. (2023) · Sensors · doi:10.3390/s23042302 · Cited by 29
The efficacy of low dose azathioprine/6-mercaptopurine in patients with inflammatory bowel disease.
Kim, D. U., Kim, Y., Kim, B. J., Chang, D. K., Son, H. J., Rhee, P., Kim, J. J., & Rhee, P. (2009) · PubMed · Cited by 29
Zecchin, C., Facchinetti, A., Sparacino, G., Man, C. D., Manohar, C. U., Levine, J. A., Basu, A., Kudva, Y. C., & Cobelli, C. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0105 · Cited by 29
Self-citationImproved postprandial glucose control with a customized Model Predictive Controller
Messori, M., Ellis, M. J., Cobelli, C., Christofides, P. D., & Magni, L. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172136 · Cited by 28
Self-citationBogdan, P. (2015) · Design, Automation, and Test in Europe · doi:10.5555/2755753.2755808 · Cited by 27
Integrated real time bowel sound detector for artificial pancreas systems
Mamun, K., & McFarlane, N. (2016) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.01.004 · Cited by 25
Sensor-based detection and estimation of meal carbohydrates for people with diabetes
Mahmoudi, Z., Cameron, F. M., Poulsen, N. K., Madsen, H., Bequette, B. W., & Jørgensen, J. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.09.012 · Cited by 25
Research Gaps, Challenges, and Opportunities in Automated Insulin Delivery Systems
Jacobs, P. G., Levy, C. J., Brown, S. A., Riddell, M. C., Çınar, A., Boughton, C. K., Breton, M. D., Dassau, E., Forlenza, G. P., Henderson, R. J., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251338754 · Cited by 24
Self-citationA Novel, Stable, Aqueous Glucagon Formulation Using Ferulic Acid as an Excipient
Bakhtiani, P. A., Caputo, N., Castle, J. R., Youssef, J. E., Carroll, J. M., David, L. L., Roberts, C. T., & Ward, W. K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814552476 · Cited by 24
Jaloli, M., & Cescon, M. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105762 · Cited by 23
The Artificial Pancreas: Is it Important to Understand How the β Cell Controls Blood Glucose?
Steil, G. M., & Grodsky, G. M. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700528 · Cited by 23
Sliding‐mode‐based controllers for automation of blood glucose concentration for type 1 diabetes
Babar, S. A., Ahmad, I., & Mughal, I. S. (2021) · IET Systems Biology · doi:10.1049/syb2.12015 · Cited by 23
“BGC is measured with the help of sensors, and the controller calculates the required amount of insulin to feed into the patient's body, and then the insulin pump injects the required amount of insulin into the body [10,11].”
BackgroundWeissberg-Benchell, J. A., Hessler, D., Fisher, L., Russell, S. J., & Polonsky, W. H. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0174 · Cited by 23
Clinical impact of blood glucose monitoring accuracy: an in-silico study
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710474 · Cited by 22
Self-citationAbbes, I. B., Richard, P.-Y., Lefebvre, M.-A., Guilhem, I., & Poirier, J.-Y. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700315 · Cited by 22
In silico testing of optimized Fuzzy P+D controller for artificial pancreas
Soylu, S., & Danışman, K. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.02.009 · Cited by 21
Jernelv, I. L., Strøm, K., Hjelme, D. R., & Aksnes, A. (2019) · Sensors · doi:10.3390/s19235130 · Cited by 21
“A blood glucose level (BGL) lower than 70 mg/dL is called hypoglycaemic, while a BGL above 180 mg/dL is called hyperglycaemic [39,40].”
BackgroundBringing closed-loop home: recent advances in closed-loop insulin delivery
Thabit, H., & Hovorka, R. (2014) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000048 · Cited by 20
Bio-inspired systems for treatment of diabetes
El-Sharkawy, M. (2016) · doi:10.25560/67962 · Cited by 20
Facchinetti, A., Sparacino, G., & Cobelli, C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700522 · Cited by 20
Self-citationBabar, S. A., Ahmad, I., Mughal, I. S., & Khan, S. A. (2021) · IEEE Access · doi:10.1109/access.2021.3057365 · Cited by 20
Messori, M., Cobelli, C., & Magni, L. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.09.148 · Cited by 20
“…Clinical Reference JDRF (2008) PAD MPL UVA 290 (Magni et al., 2007) (Kovatchev et al., 2010) JDRF pilot (2010) PAD MPL 216 (Patek et al., 2012) (Breton et al., 2012) JDRF (2011) PAD MPL UVA STF SDRI CLD SCMCI 2900 (Patek et al., 2012) (Zisser et al., 2014) (Chase et al., 2014) AP@home…”
Self-citationNimri, R., Yakoob, H., Schoenberg, B. E., & Dassau, E. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.2504 · Cited by 20
Self-citationGondhalekar, R., Dassau, E., & Doyle, F. J. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7170967 · Cited by 19
Self-citationDesign and in silico evaluation of an intraperitoneal–subcutaneous (IP–SC) artificial pancreas
Lee, J. J., Dassau, E., Zisser, H., & Doyle, F. J. (2014) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2014.02.024 · Cited by 19
“…AP, and several clinical and in silico evaluations of the P have been reported (Amrein et al., 2010; Atlas, Nimri, Miller, runberg, & Phillip, 2010; Breton et al., 2012; Cobelli et al., 2012; assau et al., 2010, 2013; Dua & Pistikopoulos, 2005; Harvey et al., 014; Hovorka et al., 2011; Kovatchev…”
BackgroundSelf-citationBalakrishnan, N. P., Lakshminarayanan, S., & Rangaiah, G. P. (2014) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2014.04.038 · Cited by 19
Ghorbani, M., & Bogdan, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944707 · Cited by 18
An Artificial Pancreas for Automated Blood Glucose Control in Patients With Type 1 Diabetes
Schmidt, S., Boiroux, D., Ranjan, A. G., J�rgensen, J., Madsen, H., & Nørgaard, K. (2015) · Therapeutic Delivery · doi:10.4155/tde.15.12 · Cited by 18
Two Decades of Research in Artificial Pancreas: Insights from a Bibliometric Analysis
Vargas, F. M. L., Arango, J. A., & Wandurraga, H. J. L. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211005500 · Cited by 18
Simulation-Based Evaluation of Treatment Adjustment to Exercise in Type 1 Diabetes
Deichmann, J., Bachmann, S., Burckhardt, M., Szinnai, G., & Kaltenbach, H. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.723812 · Cited by 18
The Closed‐Loop System Improved the Control of a Pregnant Patient with Type 1 Diabetes Mellitus
Guzmán, G. E., Viggiano, J. A., Salas, A. S.-D. L., Martínez, V., & Urbano, M. A. (2021) · Case Reports in Endocrinology · doi:10.1155/2021/7310176 · Cited by 18
Artificial Pancreas Systems: An Integrated Multivariable Adaptive Approach
Turksoy, K., Quinn, L. T., Littlejohn, E., & Çınar, A. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.00815 · Cited by 18
“Model-predictive controllers (MPC) used in vivo (Bruttomesso et al., 2009; Clarke et al., 2009; Breton et al., 2012) needed modification of model parameters for different patients in these studies.”
Felix dies natalis, insulin… ceterum autem censeo “beta is better”
Piemonti, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-021-01737-3 · Cited by 19
Lee, J. J., Dassau, E., Zisser, H., Harvey, R. A., Jovanovic, L. G., & Doyle, F. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700127 · Cited by 18
Self-citationContinuous Glucose Monitoring and Trend Accuracy: News About a Trend Compass
Signal, M., Gottlieb, R., Compte, A. L., & Chase, J. G. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814533091 · Cited by 17
Finan, D. A., McCann, T. W., Mackowiak, L., Dassau, E., Patek, S. D., Kovatchev, B. P., Doyle, F. J., Zisser, H., Anhalt, H., & Venugopalan, R. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813511730 · Cited by 17
Self-citationJabali, K. A., Ashiq, M., Ahmad, S., & Rehman, S. U. (2020) · Lincoln (University of Nebraska) · Cited by 17
Pavan, J., Salvagnin, D., Facchinetti, A., Sparacino, G., & Favero, S. D. (2022) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2022.3195072 · Cited by 17
Lee, J. J., Gondhalekar, R., & Doyle, F. J. (2014) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2014.7040485 · Cited by 17
“Thus, it is critical to develop a control algorithm that reacts quickly to the meal disturbance but does not deliver an excessive amount of insulin and induce hypoglycemia [3], [4], [5], [6], [7], [8].”
BackgroundSelf-citationCurrent advances in the utilization of nanotechnology for the diagnosis and treatment of diabetes
Devadasu, V. R., Alshammari, T. M., & Aljofan, M. (2017) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-017-0558-1 · Cited by 17
Diabetes Technology: Monitoring, Analytics, and Optimal Control
Kovatchev, B. P. (2018) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034389 · Cited by 17
“During 2008–2012, promising results were reported by several groups (Weinzimer et al. 2008; Bruttomesso et al. 2009; Clarke et al. 2009; ElKhatib et al. 2010; Hovorka et al. 2010, 2011; Renard et al. 2010; Zisser et al. 2011, 2014; Breton et al. 2012; Russell et al. 2012; Luijf et al. 2013; Sherr et al. 2013).”
BackgroundResultSelf-citationArtificial Pancreas Goes Outpatient: A New Diabetes Ecosystem
Renard, É., Cobelli, C., Zisser, H., & Kovatchev, B. P. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700601 · Cited by 16
Self-citationLeelarathna, L., Dellweg, S., Mader, J. K., Barnard, K. D., Benesch, C., Ellmerer, M., Heinemann, L., Kojzar, H., Thabit, H., Wilinska, M. E., et al. (2014) · BMJ Open · doi:10.1136/bmjopen-2014-006075 · Cited by 14
Automated Insulin Delivery—The Light at the End of the Tunnel
Turksoy, K., Frantz, N., Quinn, L., Dumin, M., Kilkus, J. M., Hibner, B. A., Çınar, A., & Littlejohn, E. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2017.02.055 · Cited by 14
Finan, D. A., McCann, T. W., Rhein, K., Dassau, E., Breton, M. D., Patek, S. D., Anhalt, H., Kovatchev, B. P., Doyle, F. J., Anderson, S. M., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814534589 · Cited by 13
Self-citationDeployment of modular MPC for type 1 diabetes control: the Italian experience 2008–2016
Favero, S. D., Toffanin, C., Magni, L., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00016-8 · Cited by 11
Self-citationArtificial pancreas systems: experiences from concept to commercialisation
Rodríguez-Sarmiento, D. L., Vargas, F. M. L., & Maira, G. (2022) · Expert Review of Medical Devices · doi:10.1080/17434440.2022.2150546 · Cited by 11
Metadata
- Authors
- Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., Toffanin, C., Hughes-Karvetski, C., Dassau, E., Zisser, H., Doyle, F. J., De Nicolao, G., Avogaro, A., Cobelli, C., Renard, E., Kovatchev, B., & on behalf of The International Artificial Pancreas (iAP) Study Group
- Affiliations
- University of Virginia (US)
- Centre National de la Recherche Scientifique (FR)
- University of Padua (IT)
- University of Pavia (IT)
- Department of Information Engineering, University of Padova, Padova, Italy
- University Hospital of Montpellier, Department of Endocrinology, Diabetes, and Nutrition, INSERM Clinical Investigation Center 1001, Institute of Functional Genomics, CNRS UMR5203, INSERM U661, University of Montpellier, Montpellier, France
- University of Virginia, Center for Diabetes Technology, Charlottesville, Virginia
- University of California, Santa Barbara (US)
- Department of Computer Engineering and System Sciences, University of Pavia, Pavia, Italy
- Corresponding author
- Breton, Marc
- ORCID
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2012-08-17
- Volume
- 61
- Issue
- 9
- Pages
- 2230-2237
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- PMC
- PMC3425406
- OpenAlex
- W2145097544
- Cited by
- 315
- References
- 34
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 4 · 2023: 9 · 2022: 6 · 2021: 15 · 2020: 7 · 2019: 23 · 2018: 28 · 2017: 33 · 2016: 27 · 2015: 36 · 2014: 52 · 2013: 45 · 2012: 7
- FWCI
- 35.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (R21DK085641, 5-R21-DK-85641)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Keywords
- artificial pancreas, feedback control, type 1 diabetes, continuous glucose monitoring, insulin pump therapy, glycemic control, hypoglycemia prevention, time in range, automated data transfer, adolescents and adults
- MeSH terms
- Adolescent, Adult, Algorithms, Automation, Blood Glucose, Computer Simulation, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin Infusion Systems, Middle Aged, Cross-Over Studies, Pancreas, Artificial
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.