Broadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user's intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“…in peripheral nerves (Micera et al., 2011; Carboni et al., 2016; Ng et al., 2016), which however presents problems related to low signal amplitude and signal-to-noise ratio, small number of identified spike patterns, and potential intraneural damage (Navarro et al., 2005; Carboni et al., 2016).”
BackgroundConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“However, current prosthetic interfaces are unable to provide sufficient, intuitive and reliable control, which is one of the main reasons for device abandonment (Atkins et al., 1996; Biddiss et al., 2007; Peerdeman et al., 2011).”
BackgroundHeckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414 · cited 1×
“During maturation of the nervous system, the motor neuron, connecting axon, neuromuscular junction and muscle fibers are physiologically aligned in their properties (Buchthal and Schmalbruch, 1980; Heckman and Enoka, 2012).”
BackgroundFarina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359 · cited 4×
“It was shown that this approach at the motor unit level is theoretically superior to classic pattern recognition of the interference EMG using global parameters in TMR patients (Farina et al., 2017).”
BackgroundMethodSelf-citationOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · cited 2×
“Considering their complexity, it is apparent that the modern prostheses cannot be controlled intuitively with this traditional interface (Ortiz-Catalan et al., 2012; Kung et al., 2013).”
BackgroundTargeted reinnervation for transhumeral amputees: current surgical technique and update on results
Dumanian, G. A., Ko, J. H., O’Shaughnessy, K. D., Kim, P. S., Wilson, C. J., & Kuiken, T. A. (2009) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181b038c9 · Cited by 130 · cited 3×
“As a consequence, the innervation of multi-headed or segmentally innervated muscles (e.g., biceps, pectoralis muscle) is separated to increase the number of available myosignals (Dumanian et al., 2009).”
BackgroundInfluentialDevelopment of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117 · cited 6×
“EMG data are recorded either from within the muscle (e.g., IMES) or epimysially from the muscle surface (e.g., MyoPlant).”
BackgroundInfluentialMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · cited 2×
“For example, an alternative approach is the direct recording from efferent fibers in peripheral nerves (Micera et al., 2011; Carboni et al., 2016; Ng et al., 2016), which however presents problems related to low signal amplitude and signal-to-noise ratio, small number of identified spike patterns, and potential intran…”
BackgroundImplantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · cited 2×
“For example, an alternative approach is the direct recording from efferent fibers in peripheral nerves (Micera et al., 2011; Carboni et al., 2016; Ng et al., 2016), which however presents problems related to low signal amplitude and signal-to-noise ratio, small number of identified spike patterns, and potential intran…”
BackgroundInnovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71 · cited 4×
“Considering their complexity, it is apparent that the modern prostheses cannot be controlled intuitively with this traditional interface (Ortiz-Catalan et al., 2012; Kung et al., 2013).”
BackgroundInfluentialFully Implantable Multi-Channel Measurement System for Acquisition of Muscle Activity
Lewis, S., Russold, M., Dietl, H., Ruff, R., Audi, J. M. C., Hoffmann, K.-P., Abu-Saleh, L., Schroeder, D., Krautschneider, W. H., Westendorff, S., et al. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2253992 · Cited by 52 · cited 2×
“…tested in extensive pre-clinical large animal trials, showing good biocompatibility and stable electrode impedance over the course of several months, and reliable acquisition of multiple adjacent EMG signals (Poppendieck et al., 2011; Lewis et al., 2013a; Bergmeister K. D. et al., 2016).”
BackgroundSelf-citation
Research works printed but not linked: 47
- Amphlett, 1975, Cross innervation and the regulatory protein system of rabbit soleus muscle, Nature, 257, 602, 10.1038/257602a0 · DOI
- Aszmann, 2008, Selective nerve transfers to improve the control of myoelectrical arm prostheses, Handchir. Mikrochir. Plast. Chir., 40, 60, 10.1055/s-2007-989415 · DOI · Paper page
- Atkins, 1996, Epidemiologic over- view of individuals with upper-limb loss and their reported research priorities, Prosthet. Orthot, 8, 2, 10.1097/00008526-199600810-00003 · DOI · Paper page
- Baker, 2010, Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors, Neural Syst. Rehabil. Eng., 18, 424, 10.1109/TNSRE.2010.2047590 · DOI · Paper page
- Bergmeister, 2016, Experimental nerve transfer model in the rat forelimb, Euro. Surg., 48, 334, 10.1007/s10353-016-0386-4 · DOI
- Bergmeister, 2016, Prosthesis control with an implantable multichannel wireless electromyography system for high-level amputees: a large-animal study, Plast. Reconstr. Surg., 137, 153, 10.1097/PRS.0000000000001926 · DOI
- Buchthal, 1980, Motor unit of mammalian muscle, Physiol. Rev., 60, 90, 10.1152/physrev.1980.60.1.90 · DOI · Paper page
- Carboni, 2016, An integrated interface for peripheral neural system recording and stimulation: system design, electrical tests and in-vivo results, Biomed. Microdevices, 18, 1, 10.1007/s10544-016-0043-5 · DOI
- Chen, 2013, Cortical motor activity and reorganization following upper-limb amputation and subsequent targeted reinnervation, Neuroimage Clin., 3, 498, 10.1016/j.nicl.2013.10.001 · DOI
- Childress, 1985, Historical aspects of powered limb prostheses, Clin. Prosthet. Orthot., 9, 2
- Farina, 2014, Bionic limbs: clinical reality and academic promises, Sci. Transl. Med., 6, 257p, 10.1126/scitranslmed.3010453 · DOI · Paper page
- Farina, 2016, Characterization of human motor units from surface EMG decomposition, Proc. IEEE, 104, 353, 10.1109/JPROC.2015.2498665 · DOI · Paper page
- Farina, 2008, Multichannel thin-film electrode for intramuscular electromyographic recordings, J. Appl. Physiol., 104, 821, 10.1152/japplphysiol.00788.2007 · DOI · Paper page
- Fifer, 2014, Simultaneous neural control of simple reaching and grasping with the modular prosthetic limb using intracranial EEG, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 695, 10.1109/TNSRE.2013.2286955 · DOI · Paper page
- Hahne, 2012, Simultaneous and proportional control of 2D wrist movements with myoelectric signals, 2012 IEEE International Workshop on Machine Learning for Signal Processing (MLSP), 1
- Holobar, 2014, Blind source identification from the multichannel surface electromyogram, Physiol. Meas., 35, R143, 10.1088/0967-3334/35/7/R143 · DOI · Paper page
- Ison, 2015, High-density electromyography and motor skill learning for robust long-term control of a 7-DoF robot arm, IEEE Trans. Neural Syst. Rehabil. Eng., 4, 424, 10.1109/TNSRE.2015.2417775 · DOI
- Kapelner, 2016, Motor unit characteristics after targeted muscle reinnervation, PLoS ONE, 11, e0149772, 10.1371/journal.pone.0149772 · DOI
- Kapelner, 2015, Classification of motor unit activity following targeted muscle reinnervation, 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), 652, 10.1109/NER.2015.7146707 · DOI
- Karimimehr, 2017, A Real-time method for decoding the neural drive to muscles using single-channel intra-muscular EMG recordings, Int. J. Neural Syst., 27, 17500253, 10.1142/S0129065717500253 · DOI
- Kuiken, 1995, The hyper-reinnervation of rat skeletal muscle, Brain Res., 676, 113, 10.1016/0006-8993(95)00102-V · DOI
- Kuiken, 2007, Targeted reinnervation for enhanced prosthetic arm function in a woman with a proximal amputation: a case study, Lancet, 369, 371, 10.1016/S0140-6736(07)60193-7 · DOI · Paper page
- Kuiken, 2005, Prosthetic command signals following targeted hyper-reinnervation nerve transfer surgery, Conf. Proc. IEEE Eng. Med. Biol. Soc., 7, 7652, 10.1109/iembs.2005.1616284 · DOI
- Lee, 2014, Recapitulating flesh with silicon and steel: advancements in upper extremity robotic prosthetics, World Neurosurg., 81, 730, 10.1016/j.wneu.2014.03.012 · DOI
- Lewis, Implantable silicone electrode for measurement of muscle activity: results of first in vivo evaluation, Biomed. Tech., 7, 10.1515/bmt-2013-4368 · DOI
- Lowery, 2006, Simulation of intramuscular EMG signals detected using implantable myoelectric sensors (IMES), IEEE Trans. Biomed. Eng., 53, 1926, 10.1109/TBME.2006.881774 · DOI
- Miller, 2008, Improved myoelectric prosthesis control using targeted reinnervation surgery: a case series, IEEE Trans. Neural Syst. Rehabil. Eng., 16, 46, 10.1109/TNSRE.2007.911817 · DOI · Paper page
- Muceli, 2012, Simultaneous and proportional estimation of hand kinematics from EMG during mirrored movements at multiple degrees-of-freedom, IEEE Trans. Neural Syst. Rehabil. Eng., 20, 371, 10.1109/TNSRE.2011.2178039 · DOI · Paper page
- Muceli, 2015, Accurate and representative decoding of the neural drive to muscles in humans with multi-channel intramuscular thin-film electrodes, J. Physiol., 593, 3789, 10.1113/JP270902 · DOI · Paper page
- Negro, 2016, Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation, J. Neural Eng., 13, 026027, 10.1088/1741-2560/13/2/026027 · DOI · Paper page
- Parker, 2006, Myoelectric signal processing for control of powered limb prostheses, J. Electromyogr. Kinesiol., 16, 541, 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- Pasquina, 2014, First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand, J. Neurosci. Methods, 244, 85, 10.1016/j.jneumeth.2014.07.016 · DOI · Paper page
- Peerdeman, 2011, Myoelectric forearm prostheses: state of the art from a user-centered perspective, J. Rehabil. Res. Dev., 48, 719, 10.1682/JRRD.2010.08.0161 · DOI · Paper page
- Poppendieck, 2011, Evaluation of implantable epimysial electrodes as possible interface to control myoelectric hand prostheses
- Prewitt, 1967, Effect of cross innervation on biochemical characteristics of skeletal muscles, Am. J. Physiol., 213, 295, 10.1152/ajplegacy.1967.213.1.295 · DOI
- Resnik, 2014, The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm, Prosthet. Orthot. Int., 38, 492, 10.1177/0309364613506913 · DOI · Paper page
- Romanul, 1967, Slow and fast muscles after cross innervation: Enzymatic and physiological changes, Arch. Neurol., 17, 387, 10.1001/archneur.1967.00470280053006 · DOI · Paper page
- Salminger, 2015, Prosthetic reconstruction in high amputations of the upper extremity, Orthopade, 44, 413, 10.1007/s00132-015-3113-0 · DOI
- Scheme, 2011, Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use, J. Rehabil. Res. Dev., 48, 643, 10.1682/JRRD.2010.09.0177 · DOI · Paper page
- Stubblefield, 2009, Occupational therapy protocol for amputees with targeted muscle reinnervation, J. Rehabil. Res. Dev., 46, 481, 10.1682/JRRD.2008.10.0138 · DOI
- Sturma, 2014, Rehabilitation following targeted muscle reinnervation in amputees, 775, 10.1007/978-3-319-08072-7_107 · DOI
- Troyk, 2007, IMES: an implantable myoelectric sensor, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2007, 1730, 10.1109/iembs.2007.4352644 · DOI
- Turker, 1993, Electromyography: some methodological problems and issues, Phys. Ther., 73, 698, 10.1093/ptj/73.10.698 · DOI · Paper page
- Vujaklija, 2016, New developments in prosthetic arm systems, Orthop. Res. Rev., 8, 31, 10.2147/ORR.S71468 · DOI · Paper page
- Weir, 2003, Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work, Proceedings of the 25th Annual International Conference of the IEEE on Engineering in Medicine and Biology Society, 1562
- Williams, 1990, Practical methods for controlling powered upper-extremity prostheses, Assist. Technol., 2, 3, 10.1080/10400435.1990.10132142 · DOI · Paper page
- Yao, 2015, Sensory cortical re-mapping following upper-limb amputation and subsequent targeted reinnervation: A case report, Neuroimage Clin., 8, 329, 10.1016/j.nicl.2015.01.010 · DOI
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
Self-citationMuceli, S., Poppendieck, W., Hoffmann, K.-P., Dosen, S., Benito-León, J., Barroso, F. O., Pons, J. L., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab047a · Cited by 33
Self-citationMuceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaed85 · Cited by 30
Self-citation
Metadata
- Authors
- Bergmeister, K. D., Vujaklija, I., Muceli, S., Sturma, A., Hruby, L. A., Prahm, C., Riedl, O., Salminger, S., Manzano-Szalai, K., Aman, M., Russold, M.-F., Hofer, C., Principe, J., Farina, D., & Aszmann, O. C.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2017-07-19
- Volume
- 11
- Pages
- 421-421
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2737536553
- Cited by
- 52
- References
- 12
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Christian Doppler Forschungsgesellschaft
- European Research Council (ERC Advanced Grant DEMOVE (No. 267888))
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.