The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Label-free cell separation and sorting in microfluidic systems
Open accessAbstract
Cell separation and sorting are essential steps in cell biology research and in many diagnostic and therapeutic methods. Recently, there has been interest in methods which avoid the use of biochemical labels; numerous intrinsic biomarkers have been explored to identify cells including size, electrical polarizability, and hydrodynamic properties. This review highlights microfluidic techniques used for label-free discrimination and fractionation of cell populations. Microfluidic systems have been adopted to precisely handle single cells and interface with other tools for biochemical analysis. We analyzed many of these techniques, detailing their mode of separation, while concentrating on recent developments and evaluating their prospects for application. Furthermore, this was done from a perspective where inertial effects are considered important and general performance metrics were proposed which would ease comparison of reported technologies. Lastly, we assess the current state of these technologies and suggest directions which may make them more accessible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationHigh gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationMassively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Berger, S. A., Talbot, L., & Yao, L. S. (1983) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.15.010183.002333 · Cited by 1,363
Microfluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Pathogenesis and Treatment of Sickle Cell Disease
Bunn, H. F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371107 · Cited by 1,154 · cited 2×
“liv er ce lls 2– 3 × 10 6 /m L – ∼ 0 5 ce lls /m in – – – [4 3, 45 ]”
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Li, J., Zhang, Z., Rosenzweig, J., Wang, Y. Y., & Chan, D. W. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.8.1296 · Cited by 893
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Laurell, T., Petersson, F., & Nilsson, A. (2007) · Chem. Soc. Rev. · doi:10.1039/b601326k · Cited by 874
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Differential exoprotease activities confer tumor-specific serum peptidome patterns
Villanueva, J. (2005) · Journal of Clinical Investigation · doi:10.1172/jci26022 · Cited by 741
English, D., & Andersen, B. R. (1974) · Journal of Immunological Methods · doi:10.1016/0022-1759(74)90109-4 · Cited by 726
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationContinuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Critical particle size for fractionation by deterministic lateral displacement
Inglis, D. W., Davis, J. A., Austin, R. H., & Sturm, J. C. (2006) · Lab on a Chip · doi:10.1039/b515371a · Cited by 421
Equilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413
Self-citationCummings, E. B., & Singh, A. K. (2003) · Analytical Chemistry · doi:10.1021/ac0340612 · Cited by 375
Sheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Self-citationPetersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2005) · Lab Chip · doi:10.1039/b405748c · Cited by 360
Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330
Sudarsan, A. P., & Ugaz, V. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507976103 · Cited by 324
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications
Crowley, T. A., & Pizziconi, V. (2005) · Lab on a Chip · doi:10.1039/b502930a · Cited by 280
Silicon-based microfilters for whole blood cell separation
Ji, H. M., Samper, V., Chen, Y., Heng, C. K., Lim, T. M., & Yobas, L. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9131-x · Cited by 272
Soft inertial microfluidics for high throughput separation of bacteria from human blood cells
Wu, Z., Willing, B., Bjerketorp, J., Jansson, J. K., & Hjort, K. (2009) · Lab on a Chip · doi:10.1039/b817611f · Cited by 263
Cheng, I.-F., Chang, H.-C., Hou, D., & Chang, H.-C. (2007) · Biomicrofluidics · doi:10.1063/1.2723669 · Cited by 262
Red blood cell magnetophoresis
Zborowski, M., Ostera, G. R., Moore, L. R., Milliron, S., Chalmers, J. J., & Schechter, A. N. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75069-3 · Cited by 260
Particle Focusing Mechanisms in Curving Confined Flows
Gossett, D. R., & Carlo, D. D. (2009) · Analytical Chemistry · doi:10.1021/ac901306y · Cited by 246
Self-citationAc electrokinetics: a survey of sub-micrometre particle dynamics
Green, N. G., Ramos, A., & Morgan, H. (2000) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/33/6/308 · Cited by 230
Biomimetic Autoseparation of Leukocytes from Whole Blood in a Microfluidic Device
Shevkoplyas, S. S., Yoshida, T., Munn, L. L., & Bitensky, M. W. (2005) · Analytical Chemistry · doi:10.1021/ac049037i · Cited by 225
VanDelinder, V., & Groisman, A. (2006) · Analytical Chemistry · doi:10.1021/ac060042r · Cited by 209
Morgan, H., Izquierdo, A. G., Bakewell, D., Green, N. G., & Ramos, A. (2001) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/34/10/316 · Cited by 209
Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations
Han, K.-H., & Frazier, A. B. (2006) · Lab Chip · doi:10.1039/b514539b · Cited by 205
An Equilibrium Method for Continuous-Flow Cell Sorting Using Dielectrophoresis
Vahey, M. D., & Voldman, J. (2008) · Analytical Chemistry · doi:10.1021/ac7020568 · Cited by 203
Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma
Faivre, M., Abkarian, M., Bickraj, K., & Stone, H. A. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043002001 · Cited by 196
Cell separation by non-inertial force fields in microfluidic systems
Tsutsui, H., & Ho, C.-M. (2009) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2008.08.006 · Cited by 190
Continuous flow microfluidic device for cell separation, cell lysis and DNA purification
Chen, X., Cui, D., Liu, C., Li, H., & Chen, J. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.11.057 · Cited by 185
Field-flow fractionation in bioanalysis: A review of recent trends
Roda, B., Zattoni, A., Reschiglian, P., Moon, M. H., Mirasoli, M., Michelini, E., & Roda, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.01.015 · Cited by 183
Magnetophoretic separation of blood cells at the microscale
Furlani, E. P. (2007) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/40/5/001 · Cited by 166
Vykoukal, J. V., Vykoukal, D. M., Freyberg, S., Alt, E., & Gascoyne, P. R. C. (2008) · Lab on a Chip · doi:10.1039/b717043b · Cited by 165
Choi, S., & Park, J.-K. (2007) · Lab on a Chip · doi:10.1039/b701227f · Cited by 162
Huang, R., Barber, T. A., Schmidt, M. A., Tompkins, R. G., Toner, M., Bianchi, D. W., Kapur, R., & Flejter, W. L. (2008) · Prenatal Diagnosis · doi:10.1002/pd.2079 · Cited by 158
Continuous magnetophoretic separation of blood cells in microdevice format
Han, K.-H., & Frazier, A. B. (2004) · Journal of Applied Physics · doi:10.1063/1.1803628 · Cited by 151
Krabchi, K., Gros‐Louis, F., Yan, J., Bronsard, M., Massé, J., Forest, J., & Drouin, R. (2001) · Clinical Genetics · doi:10.1034/j.1399-0004.2001.600209.x · Cited by 145
Optically Controlled Cell Discrimination and Trapping Using Optoelectronic Tweezers
Ohta, A. T., Chiou, P.-Y. E., Phan, H. L., Sherwood, S. W., Yang, J. M., Lau, A. N. K., Hsu, H.-Y., Jamshidi, A., & Wu, M. C. (2007) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.893558 · Cited by 140
Membrane-free microfiltration by asymmetric inertial migration
Seo, J., Lean, M. H., & Kole, A. (2007) · Applied Physics Letters · doi:10.1063/1.2756272 · Cited by 139
Silane–dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Aronsson, M., Rundström, G., Pettersson, C., Mendel-Hartvig, I., Bakker, J. W. P., Martinsson, E., Liedberg, B., MacCraith, B. D., Öhman, O., et al. (2008) · Lab on a Chip · doi:10.1039/b800297e · Cited by 132
Microvortex for focusing, guiding and sorting of particles
Hsu, C., Carlo, D. D., Chen, C., Irimia, D., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b813434k · Cited by 130
VanDelinder, V., & Groisman, A. (2007) · Analytical Chemistry · doi:10.1021/ac061659b · Cited by 129
Microfluidic devices for size-dependent separation of liver cells
Yamada, M., Kano, K., Tsuda, Y., Kobayashi, J., Yamato, M., Seki, M., & Okano, T. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9055-5 · Cited by 125
Deformability considerations in filtration of biological cells
Kuo, J. S., Zhao, Y., Schiro, P. G., Ng, L., Lim, D. S. W., Shelby, J. P., & Chiu, D. T. (2010) · Lab on a Chip · doi:10.1039/b922301k · Cited by 118
Lateral-driven continuous magnetophoretic separation of blood cells
Jung, J.-H., & Han, K.-H. (2008) · Applied Physics Letters · doi:10.1063/1.3036898 · Cited by 100
Gagnon, Z. R., & Chang, H. (2005) · Electrophoresis · doi:10.1002/elps.200500129 · Cited by 100
Continuous cell partitioning using an aqueous two‐phase flow system in microfluidic devices
Yamada, M., Kasim, V., Nakashima, M., Edahiro, J., & Seki, M. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20276 · Cited by 96
A planar microfabricated fluid filter
Brody, J. P., Osborn, T. D., Forster, F. K., & Yager, P. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80042-8 · Cited by 95
Fractionation of polydisperse colloid with acousto-optically generated potential energy landscapes
Milne, G., Rhodes, D. P., MacDonald, M. P., & Dholakia, K. (2007) · Optics Letters · doi:10.1364/ol.32.001144 · Cited by 87
Altered expression of CD11b/CD18 and CD62L on human monocytes after cell preparation procedures
Lundahl, J., Halldén, G., Hallgren, M., Sköld, C. M., & HED, J. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)00303-e · Cited by 87
Separation of particles by pulsed dielectrophoresis
Cui, H., Voldman, J., He, X., et al. (2009) · Lab on a Chip · doi:10.1039/b906202e · Cited by 85
Biochip for separating fetal cells from maternal circulation
Mohamed, H., Turner, J. N., & Caggana, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.06.025 · Cited by 83
Sun, T., Morgan, H., & Green, N. G. (2007) · Physical Review E · doi:10.1103/physreve.76.046610 · Cited by 81
Size-based microfluidic enrichment of neonatal rat cardiac cell populations
Murthy, S. K., Sethu, P., Vunjak‐Novakovic, G., Toner, M., & Radisic, M. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8169-5 · Cited by 78
Gupta, S., Feke, D. L., & Manas‐Zloczower, I. (1995) · Chemical Engineering Science · doi:10.1016/0009-2509(95)00154-w · Cited by 77
Multidirectional sorting modes in deterministic lateral displacement devices
Long, B., Heller, M., Beech, J. P., Linke, H., Bruus, H., & Tegenfeldt, J. O. (2008) · Physical Review E · doi:10.1103/physreve.78.046304 · Cited by 70
Centrifugation attenuates the fluid shear response of circulating leukocytes
Fukuda, S., & Schmid‐Schönbein, G. W. (2002) · Journal of Leukocyte Biology · doi:10.1189/jlb.72.1.133 · Cited by 70
Wang, X. (1999) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(98)00122-6 · Cited by 68
Methods in cell separation for biomedical application: cryogels as a new tool
Kumar, A., & Bhardwaj, A. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034008 · Cited by 66
A 3D paired microelectrode array for accumulation and separation of microparticles
Chen, D. F., Du, H., & Li, W. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/7/008 · Cited by 64
Gordon, J. E., Gagnon, Z. R., & Chang, H. (2007) · Biomicrofluidics · doi:10.1063/1.2818767 · Cited by 61
Microfluidic chips for cell sorting
Chen, P., Feng, X., Du, W., & Liu, B.-F. (2007) · Frontiers in bioscience · doi:10.2741/2859 · Cited by 61
Han, K.-H., Han, S., & Frazier, A. B. (2009) · Lab on a Chip · doi:10.1039/b909753h · Cited by 54
Diamagnetic capture mode magnetophoretic microseparator for blood cells
Han, K.-H., & Frazier, A. B. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859097 · Cited by 54
Hager, G., Castillo‐Tong, D. C., Schiebel, I., et al. (2005) · Gynecologic Oncology · doi:10.1016/j.ygyno.2005.04.042 · Cited by 31
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationDeformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Metadata
- Authors
- Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2010-04-25
- Volume
- 397
- Issue
- 8
- Pages
- 3249-3267
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2109591733
- Cited by
- 930
- References
- 88
- FWCI
- 24.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.