Cortical responses elicited by photovoltaic subretinal prostheses exhibit similarities to visually evoked potentials
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We have previously developed a wireless photovoltaic retinal prosthesis, in which camera-captured images are projected onto the retina using pulsed near-IR light. Each pixel in the subretinal implant directly converts pulsed light into local electric current to stimulate the nearby inner retinal neurons. Here we report that implants having pixel sizes of 280, 140 and 70 μm implanted in the subretinal space in rats with normal and degenerate retina elicit robust cortical responses upon stimulation with pulsed near-IR light. Implant-induced eVEP has shorter latency than visible light-induced VEP, its amplitude increases with peak irradiance and pulse duration, and decreases with frequency in the range of 2–20 Hz, similar to the visible light response. Modular design of the arrays allows scalability to a large number of pixels, and combined with the ease of implantation, offers a promising approach to restoration of sight in patients blinded by retinal degenerative diseases. Visual prosthetics based on photovoltaic devices have been proposed to allow the functional restoration of lost sight. Mandel et al. assess the retinal responses to implanted retinal prosthetics in rats with degenerate retinas and find that they elicit responses in the visual cortex when stimulated by light.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ranibizumab and bevacizumab for neovascular age-related macular degeneration
(2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102673 · Cited by 2,669
Ranibizumab and Bevacizumab for Treatment of Neovascular Age-related Macular Degeneration
Martin, D. F., Maguire, M. G., Fine, S. L., Ying, G.-S., Jaffe, G. J., Grunwald, J. E., Toth, C., Redford, M., & Ferris, F. L. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.03.053 · Cited by 1,715
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 3×
“This approach is adopted by several groups, including Retina Implant AG, where a subretinal video camera having 1500 pixels (70 μm in size) is used to convert images into local electric current in each pixel, to stimulate the retina [8].”
BackgroundMethodResultInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 3×
“Implantation of the system including the extraocular receiving coil and signal decoding electronics box connected to the retinal stimulation array via transscleral cable is rather complex, with 30% of patients reporting implant-related complications [7].”
BackgroundResultFriedman, D. S. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.7.1019 · Cited by 656
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“Since epiretinal electrodes are positioned on top on the nerve fiber layer and axonal stimulation thresholds are similar to that of RGC somas [11], axonal stimulation is hard to avoid.”
BackgroundArtificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 3×
“It should be noted however, that subretinal stimulation in patients blinded by Retinitis Pigmentosa (light perception only) resulted in visual acuity up to 20/550 [16].”
BackgroundComparison of Age-related Macular Degeneration Treatments Trials Research, G. (2011) · doi:10.1056/nejmicm1005605 · Cited by 273
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163 · cited 1×
“Excitation of retinal ganglion cells (RGCs) by electrodes positioned on the epiretinal surface bypasses inner retinal circuitry and requires high frequency stimulation to elicit burst responses [9, 10].”
BackgroundMORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158 · cited 1×
“In these blinding conditions photoreceptors degenerate, yet the inner retinal neurons (inner nuclear and ganglion cell layers) that process the visual signals and relay them to the brain are relatively well preserved [4-6] .”
Background
Cited by
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Choi, C., Choi, M. K., Liu, S., Kim, M., Park, O. K., Im, C., Kim, J., Qin, X., Lee, G. J., Cho, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01824-6 · Cited by 540
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T., Mathieson, K., Huie, P., Harris, J., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 351
Self-citationA fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya-Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Di Paolo, M., Di Marco, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 290
Bioinspired Artificial Eyes: Optic Components, Digital Cameras, and Visual Prostheses
Lee, G. J., Choi, C., Kim, D., & Song, Y. M. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705202 · Cited by 252
Inorganic semiconductor biointerfaces
Jiang, Y., & Tian, B. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0062-3 · Cited by 238
Advances in retinal prosthesis systems
Bloch, E., Luo, Y., & da Cruz, L. (2019) · Therapeutic Advances in Ophthalmology · doi:10.1177/2515841418817501 · Cited by 201
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Tandon, B., Magaz, A., Balint, R., Blaker, J. J., & Cartmell, S. H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.12.012 · Cited by 176
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
“…mind that photoreceptors above the subretinal implant disappear shortly after chronic implantation due to their separation from the retinal pigmented epithelium, so the OPL becomes the most realistic approximation of the electrodes location in-vivo, even with a wild-type retina (Mandel et al 2013).”
BackgroundImproving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Characteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays
Ho, E., Lei, X., Flores, T., Lorach, H., Huang, T., Galambos, L., Kamins, T., Harris, J., Mathieson, K., & Palanker, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab34b3 · Cited by 65
“6 demonstrated that VEP is not present when conduction along the optic nerve is blocked [25].”
Photovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63
Thorn, J. T., Migliorini, E., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb5bc · Cited by 34
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Self-citationThe argus ii retinal prosthesis system
Bloch, E., & da Cruz, L. (2020) · Prosthesis · doi:10.5772/intechopen.84947 · Cited by 31
Implantation of modular photovoltaic subretinal prosthesis
Lee, D. Y., Lorach, H., Huie, P., & Palanker, D. (2016) · Ophthalmic Surgery, Lasers and Imaging Retina · doi:10.3928/23258160-20160126-11 · Cited by 30
Self-citationChapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21
Cicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
Metadata
- Authors
- Mandel, Y., Goetz, G., Lavinsky, D., Huie, P., Mathieson, K., Wang, L., Kamins, T., Galambos, L., Manivanh, R., Harris, J., & Palanker, D.
- Venue
- Nature Communications
- Published
- 2013-06-18
- Volume
- 4
- Issue
- 1
- Pages
- 1980-1980
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2145592817
- Cited by
- 130
- References
- 13
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.