The effect of contacting force on photoplethysmographic signals
Open accessAbstract
Photoplethysmography (PPG) has been used in oxygen saturation measurement, heart rate monitoring, and the assessment of peripheral circulation and large artery compliance. However, the waveform of the photoplethysmographic signal may be affected by the contacting force between the sensor and the measurement site. The aim of this study is to investigate the change in pulse amplitude (AC), DC amplitude, ratio of AC/DC and normalized pulse area of the reflective photoplethysmographic signals with increasing contacting force, from 0.2 N to 1.8 N. Signals were recorded from the fingers of fifteen healthy subjects. With increasing contacting force, the DC amplitude increased and the normalized pulse area decreased, whereas the pulse amplitude and the ratio of AC/DC increased first and then decreased. For different subjects, the pulse amplitude and the ratio of AC/DC peaked at different contacting forces, from 0.2 N to 1.0 N, and most of the subjects achieved their maximum pulse amplitude within 0.2-0.4 N. Over the range of contacting force between 0.2 N and 0.8 N, the DC amplitude and the normalized pulse area had significant changes (p < 0.001). The results suggest that the effects of contacting force should be carefully examined in the design of photoplethysmography-based health care devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As reported by Teng and Zhang, with an applied force at the finger of 0.2–1.8 N, there was an increase in AC amplitude and AC/DC ratio until the parameters reached a peak and then decreased, while the pulse area decreased, and the DC offset increased [206].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [206]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,846
Medical instrumentation: Application and design
Undar, A., Calhoon, J., & da Rocha, A. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,019
(1997) · Institute of Physics eBooks · doi:10.1887/0750304677 · Cited by 455
(1997) · Series in medical physics and biomedical engineering · doi:10.1201/9781420050790 · Cited by 364
Nakajima, K., TAMURA, T., & Miike, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00066-6 · Cited by 244
Mauck, G. W., Smith, C. R., Geddes, L. A., & BOURLAND, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
Mascaro, S. A., & Asada, H. H. (2001) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.964669 · Cited by 192
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
Dorlas, J. C., & Nijboer, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160
Research works printed but not linked: 7
- Challoner A V J, 1979, Noninvasive Physiological Measurements, 1, 125
- de Pater I W, 1962, Acta Physiol. Pharmacol. Neerl., 10, 378
- Driscoll M D, 1995, Clin. Invest. Med., 18, 370
- Eldrup-Jorgensen S, 1966, Surgery, 59, 505
- Hertzman A B, 1937, Am. J. Physiol., 119, 334
- Sapoznikov D, 1974, Eur. J. Cardiol., 1, 447
- Yamakoshi K, 1995, Homeostasis, 36, 90
Cited by
Sorted by citations
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“Changes in the AC pulse amplitude, DC amplitude, ratio of AC/DC amplitudes and normalized pulse area of the reflected PPG signal have been investigated [35].”
BackgroundHow accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2017) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 619
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 589
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Current progress of photoplethysmography and SPO2 for health monitoring
TAMURA, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 274
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Васильев, П. В., Ерофеев, Н. П., Podolyan, N. P., & Владимирович, Р. Р. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 250
Kim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 260
Sun, Y., Hu, S., Azorin-Peris, V., Chambers, J. A., Zhu, Y., & Greenwald, S. E. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602852 · Cited by 213
Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review
Sim, J. K., Brothers, M. C., Slocik, J. M., Islam, A. E., Maruyama, B., Grigsby, C. C., Naik, R. R., & Kim, S. S. (2022) · Advanced Science · doi:10.1002/advs.202104426 · Cited by 195
Non-contact detection of oxygen saturation based on visible light imaging device using ambient light
Kong, L., Zhao, Y., Dong, L., Jian, Y., Jin, X., Li, B., Feng, Y., Liu, M., Liu, X., & Wu, H. R. (2013) · Optics Express · doi:10.1364/oe.21.017464 · Cited by 187
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Noncontact imaging photoplethysmography to effectively access pulse rate variability
Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R. S., & Greenwald, S. E. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061205 · Cited by 167
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150
Sun, Y., Azorin-Peris, V., Kalawsky, R. S., Hu, S., Papin, C., & Greenwald, S. E. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.3.037005 · Cited by 133
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 134
Photoplethysmography and nociception
Korhonen, I., & Yli‐Hankala, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02026.x · Cited by 105
Theoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94
Self-citationOrigin of Photoplethysmographic Waveform at Green Light
Kamshilin, A. A., & Борисович, М. Н. (2017) · Physics Procedia · doi:10.1016/j.phpro.2017.01.024 · Cited by 90
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70
Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring
Tseng, H.-J., Tian, W., & Wu, W.-J. (2013) · Sensors · doi:10.3390/s130505478 · Cited by 70
Foo, J. Y. A. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.01.001 · Cited by 70
A new approach for non-intrusive monitoring of blood pressure on a toilet seat
Kim, J. S., Chee, Y. J., Park, J. W., Choi, J. W., & Park, K. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/2/010 · Cited by 64
Levin, R. J., & Wylie, K. R. (2007) · The Journal of Sexual Medicine · doi:10.1111/j.1743-6109.2007.00669.x · Cited by 60
Data-driven estimation of blood pressure using photoplethysmographic signals
Gao, S. C., Wittek, P., Zhao, L., & Jiang, W. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590814 · Cited by 59
Müller, A. M., Wang, N. X., Yao, J., Tan, C. S., Low, I. C. C., Lim, N., Tan, J., Tan, A. W. H., & Müller‐Riemenschneider, F. (2019) · JMIR mhealth and uhealth · doi:10.2196/14120 · Cited by 56
Skin inhomogeneity as a source of error in remote PPG-imaging
Moço, A., Stuijk, S., & de Haan, G. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004718 · Cited by 57
Chan, G. S. H., Middleton, P. M., Celler, B. G., Wang, L., & Lovell, N. H. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/009 · Cited by 52
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Self-citationHuynh, S., Balan, R. K., Ko, J., & Lee, Y. (2019) · ACM Conference on Embedded Networked Sensor Systems (SenSys) · doi:10.1145/3356250.3360036 · Cited by 52
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Shaltis, P., Reisner, A. T., & Asada, H. H. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615331 · Cited by 48
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
Grabovskis, A., Marcinkevics, Z., Rubins, U., & Kviesis-Kipge, E. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.2.027004 · Cited by 47
Hsiu, H., Hsu, C.-L., & Wu, T.-L. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411910396288 · Cited by 46
Peripheral photoplethysmography variability analysis of sepsis patients
Middleton, P. M., Tang, C. H. H., Chan, G. S. H., Bishop, S. M., Savkin, A. V., & Lovell, N. H. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0713-z · Cited by 45
Electromechanical properties of knitted wearable sensors: part 1 – theory
Wang, J., Long, H., Soltanian, S., Servati, P., & Ko, F. (2013) · Textile Research Journal · doi:10.1177/0040517513487789 · Cited by 44
Paloheimo, M., Sahanne, S., & Uutela, K. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq065 · Cited by 44
Non-contact remote estimation of cardiovascular parameters
Fan, Q., & Li, K. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.09.022 · Cited by 44
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 46
Middleton, P. M., Chan, G. S. H., O’Lone, E., Steel, E., Carroll, R., Celler, B. G., & Lovell, N. H. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9140-1 · Cited by 41
The effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Self-citationEffects of Contact Pressure in Reflectance Photoplethysmography in an In Vitro Tissue-Vessel Phantom
May, J. M., Mejía‐Mejía, E., Nomoni, M., Budidha, K., Choi, C., & Kyriacou, P. A. (2021) · Sensors · doi:10.3390/s21248421 · Cited by 44
Determinants of photoplethysmography signal quality at the wrist
Charlton, P. H., Marozas, V., Mejía‐Mejía, E., Kyriacou, P. A., & Mant, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000585 · Cited by 38
Remote photoplethysmography based on implicit living skin tissue segmentation
Bobbia, S., Benezeth, Y., & Dubois, J. (2016) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2016.7899660 · Cited by 38
Chiang, P.-Y., Chao, P. C.-P., Tarng, D., & Yang, C. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701780 · Cited by 35
Relations between ac-dc components and optical path length in photoplethysmography
Lee, C., Shin, H., & Lee, M. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3600769 · Cited by 34
Effects of skin surface temperature on photoplethysmograph
Jeong, I. C., Yoon, H., Kang, H., & Yeom, H. (2014) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.5.4.429 · Cited by 33
Wang, H., Wang, L., Sun, N., Yao, Y., Hao, L., Xu, L., & Greenwald, S. E. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01563 · Cited by 39
ImpediBands: Body Coupled Bio-Impedance Patches for Physiological Sensing Proof of Concept
Sel, K., Ibrahim, B., & Jafari, R. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2995810 · Cited by 33
Optical Fibre-Based Pulse Oximetry Sensor with Contact Force Detection
Liu, C., Correia, R., Ballaji, H., Korposh, S., Hayes-Gill, B., & Morgan, S. (2018) · Sensors · doi:10.3390/s18113632 · Cited by 32
Berwal, D., Kuruba, A., Shaikh, A. M., Udupa, A., & Baghini, M. S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3170069 · Cited by 32
Jeong, I., Jun, S., Um, D., Oh, J., & Yoon, H.-R. (2010) · Yonsei Medical Journal · doi:10.3349/ymj.2010.51.3.345 · Cited by 31
Bousefsaf, F., Maaoui, C., & Pruski, A. (2016) · Bio-Medical Materials and Engineering · doi:10.3233/bme-161606 · Cited by 31
Reflectance Forehead Pulse Oximetry: Effects of Contact Pressure During Walking
Dresher, R. P., & Mendelson, Y. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260136 · Cited by 31
Variations of HRV analysis in different approaches
Chang, F. C., Chang, C.-C., Chiu, C. C., Hsu, S.-Y., & Lin, Y. (2007) · Computers in cardiology · doi:10.1109/cic.2007.4745410 · Cited by 30
A Non-Invasive Hemoglobin Detection Device Based on Multispectral Photoplethysmography
Zhu, J., Sun, R., Liu, H., Wang, T., Cai, L., Chen, Z., & Heng, B. (2023) · Biosensors · doi:10.3390/bios14010022 · Cited by 28
Contactless and Cuffless Monitoring of Blood Pressure on a Chair Using E-Textile Materials
Wu, K.-F., Chan, C.-H., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2006.360107 · Cited by 28
Self-citationA contact-force regulated photoplethysmography (PPG) platform
Sim, J. K., Ahn, B., & Doh, I. (2018) · AIP Advances · doi:10.1063/1.5020914 · Cited by 27
Multi-channel pulse oximetry for wearable physiological monitoring
Mendelson, Y., Dao, D. K., & Chon, K. H. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575518 · Cited by 27
The Effect of Light Conditions on Photoplethysmographic Image Acquisition Using a Commercial Camera
Liu, H., Wang, Y., & Wang, L. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2360200 · Cited by 27
Algorithm for identifying and separating beats from arterial pulse records
Treo, E. F., Herrera, M. C., & Valentinuzzi, M. E. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-48 · Cited by 26
Influence of a skin status on the light interaction with dermis
Kamshilin, A. A., Mamontov, O. V., Koval, V. T., Zayats, G. A., & Владимирович, Р. Р. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004326 · Cited by 25
PPG delineator for real-time ubiquitous applications
Farooq, U., Jang, D.-G., Park, J.-H., & Park, S.-H. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626023 · Cited by 25
A new method to estimate arterial blood pressure using photoplethysmographic signal
Jeong, I. C., Ko, J. I., Hwang, S. O., & Yoon, H. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260663 · Cited by 24
Wang, C.-F., Wang, T.-Y., Kuo, P.-H., Wang, H., Li, S.-Z., Lin, C., Chan, S.-C., Liu, T., Lo, Y., Lin, S.-H., et al. (2023) · Biosensors · doi:10.3390/bios13030321 · Cited by 24
Middleton, P. M., Chan, G. S. H., O’Lone, E., Steel, E., Carroll, R., Celler, B. G., & Lovell, N. H. (2009) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00843.x · Cited by 23
Piezoresistive Soft Condensed Matter Sensor for Body-Mounted Vital Function Applications
Melnykowycz, M., Tschudin, M., & Clemens, F. J. (2016) · Sensors · doi:10.3390/s16030326 · Cited by 24
Real-Time Temporal Superpixels for Unsupervised Remote Photoplethysmography
Bobbia, S., Luguern, D., Benezeth, Y., Nakamura, K., Gómez, R., & Dubois, J. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00182 · Cited by 23
Non-Contact Reflectance Photoplethysmography: Progress, Limitations, and Myths
Špetlík, R., Čech, J., & Matas, J. (2018) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2018.00111 · Cited by 22
Wearable Forehead Pulse Oximetry: Minimization of Motion and Pressure Artifacts
Dresher, R. P. (2006) · Digital WPI · Cited by 22
Investigating the impact of contact pressure on photoplethysmograms
Sirkiä, J., Panula, T., & Kaisti, M. (2024) · Biomedical Engineering Advances · doi:10.1016/j.bea.2024.100123 · Cited by 26
The In Vivo Diagnosis of Malaria: Feasibility Study Into a Magneto-Optic Fingertip Probe
Newman, D. M., Matelon, R. J., Wears, M. L., & Savage, L. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2029068 · Cited by 20
A Wrist-worn Respiration Monitoring Device using Bio-Impedance
Sel, K., Brown, A., Jang, H., Krumholz, H. M., Lu, N., & Jafari, R. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176367 · Cited by 19
Carek, A. M., & Inan, O. T. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2683801 · Cited by 20
A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation
Katan, M., Pearl, O., Tzroya, A., Duadi, H., & Fixler, D. (2024) · Biosensors · doi:10.3390/bios14030132 · Cited by 18
Extraction of photoplethysmographic waveform variability by lowpass filtering
Chan, G. S. H., Middleton, P. M., Lovell, N. H., & Celler, B. G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615746 · Cited by 17
A novel method based on two cameras for accurate estimation of arterial oxygen saturation
Liu, H., Ivanov, K., Wang, Y., & Wang, L. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0045-1 · Cited by 17
Blood pressure assessment with in-ear photoplethysmography
Xing, X., Ma, Z., Xu, S., Zhang, M., Zhao, W., Song, M., & Dong, W. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac2a71 · Cited by 16
Vessel calibre and haemoglobin effects on pulse oximetry
McEwen, M., Bull, G. P., & Reynolds, K. J. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/001 · Cited by 16
Effect of lingual gauze swab placement on pulse oximeter readings in anaesthetised dogs and cats
Mair, A. R., Martínez‐Taboada, F., & Nitzan, M. (2016) · Veterinary Record · doi:10.1136/vr.103861 · Cited by 19
The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2024) · Applied Sciences · doi:10.3390/app14135704 · Cited by 14
Hoevenaars, D., Yocarini, I. E., Paraschiakos, S., Holla, J., de Groot, S., Kraaij, W., & Janssen, T. W. J. (2022) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/27637 · Cited by 13
Feasibility of Wearable PPG for Simultaneous Hand Gesture and Force Level Classification
Li, D., Kang, P., Zhu, K., Li, J., & Shull, P. B. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3241126 · Cited by 13
Chen, Y. J., Lin, L., Yang, S., Hwang, K., Liao, C., & Ho, W. (2023) · IEEE Access · doi:10.1109/access.2023.3307637 · Cited by 13
Yuan, H., Poeggel, S., Newe, T., Lewis, E., Viphavakit, C., & Leen, G. (2017) · Sensors · doi:10.3390/s17030556 · Cited by 13
Hsiao, C.-C., Horng, J., Lee, R.-G., & Lin, R. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8123084 · Cited by 13
Impairing Factors in Remote-PPG Pulse Transit Time Measurements on the Face
Moço, A., Stuijk, S., van Gastel, M., & de Haan, G. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00184 · Cited by 11
Photoplethysmography system for blood pulsation detection in unloaded artery conditions
Grabovskis, A., Marcinkevics, Z., Rubenis, O., Rubins, U., & Lusa, V. (2012) · SPIE Proceedings · doi:10.1117/12.922649 · Cited by 11
Kasbekar, R. S., & Mendelson, Y. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aacfe5 · Cited by 10
An Exploration of Blue PPG Signal Using a Novel Color Sensorbased PPG System
Shchelkanova, E., Shchelkanov, A., Shchapova, L., & Shibata, T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175745 · Cited by 10
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2023) · Sensors · doi:10.3390/s23146628 · Cited by 9
Inter-Method Reliability of Pulse Volume Related Measures Derived Using Finger-Photoplethysmography
Matsumura, K., Shimizu, K., Rolfe, P. J., Kakimoto, M., & Yamakoshi, T. (2017) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000197 · Cited by 9
Lee, J., Yang, S.-M., Park, J., Kim, H. C., Kim, E., Jang, Y., Kim, J., & Kim, H. (2018) · Pediatric Anesthesia · doi:10.1111/pan.13415 · Cited by 9
Intra-beat biomarker for accurate continuous non-invasive blood pressure monitoring
Abiri, A., Chou, E., Qian, C., Rinehart, J. B., & Khine, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-19096-6 · Cited by 10
Development of a remote photoplethysmographic technique for human biometrics
Shi, P. A., Hu, S., Echiadis, A., Azorin-Peris, V., Zheng, J., & Zhu, Y. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.807360 · Cited by 9
Bousefsaf, F., Maaoui, C., & Pruski, A. (2014) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit.2014.6996985 · Cited by 9
Metadata
- Authors
- Teng, X. F., & Zhang, Y. T.
- Affiliations
- Chinese University of Hong Kong (HK)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2004-08-12
- Volume
- 25
- Issue
- 5
- Pages
- 1323-1335
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1965659123
- Cited by
- 171
- References
- 32
- Citations by year
- 2026: 6 · 2025: 11 · 2024: 12 · 2023: 12 · 2022: 8 · 2021: 8 · 2020: 7 · 2019: 6 · 2018: 13 · 2017: 14 · 2016: 7 · 2015: 6 · 2014: 6 · 2013: 6 · 2012: 7
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Innovation and Technology Fund
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, contact force, pulse amplitude, finger photoplethysmography
- MeSH terms
- Adult, Biomechanical Phenomena, Female, Humans, Male, Pressure, Pulse, Reproducibility of Results, Artifacts, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review