The issues of monitoring and fault diagnosis of drives with permanent magnet synchronous motors (PMSM) are currently very topical due to the increasing use of these drives in safety-critical devices. Every year, more and more articles on this subject are published. Therefore, the aim of this article is to update the overview of diagnostic methods and techniques for PMSM drives. Each of the main chapters of the article focuses on a specific element of the drive system (motor, power converter, measuring sensors), with particular emphasis on the components of the motor (stator windings, magnets, bearings, rotor). The main sections on PMSM fault diagnosis are divided according to the type of methods used to obtain the symptoms of the damage. In addition, a review of methods using the analysis of control structure signals for the diagnosis of damage to a vector-controlled motor is presented, as well as the latest achievements of researchers in the field of shallow and deep neural networks for the detection and classification of PMSM drives failures. Based on the presented literature analyses, some development trends and challenges related to the development of diagnostics and fault-tolerant control of PMSM drives are discussed in the conclusion part.
Verified 2026-11-19 · 1 reference not checked yet
Overview
CoChat Summary
TL;DR
This IEEE Access review surveys fault diagnosis and fault-tolerant control (FTC) for permanent magnet synchronous motor (PMSM) drives, covering motor, converter, and sensor faults and methods based on signal analysis, mathematical models, control-structure signals, and artificial intelligence. It synthesizes the literature and identifies future challenges in transient diagnostics, multiple-fault diagnosis, AI/deep learning, hardware implementation, and prognostics.
Key findings
- The review classifies PMSM faults into electrical, magnetic, and mechanical types and cites component failure statistics: stator winding failures account for 36–66% of AC motor breakdowns, bearing faults 13–41%, bearing failures about 40–50% of all electric motor failures, power semiconductor device damages about 35% of all adjustable-speed-drive faults, DC-link capacitors about 30% of frequency-converter failures, and transistor failures 12% of all electric-drive failures.
- Signal-analysis methods dominate PMSM diagnostics: FFT/MCSA/EPVA are widely used for inter-turn short circuits (ITSCs) and demagnetization, while time-frequency methods such as STFT, WT, WVD, CWD, and HHT address non-stationary conditions; control-structure signals can enable sensorless diagnostics but are sensitive to controller bandwidth.
- AI-based diagnostics are reviewed: shallow neural networks (MLP, RBF, SOM, PNN, BNN) require preprocessing, while deep networks (CNN, LSTM) allow direct feature extraction; Table IX reports literature classification accuracies such as MLP 99.02% on vibrations, CNN 99.38% on flux, CNN 99.28% on stator currents, and SOM 93.00% on vibrations.
- FTC is divided into passive and active approaches; active FTC uses fault detection and diagnosis with reconfiguration or compensation, speed-sensor FTC relies on sensorless estimators, current-sensor FTC uses observers, and inverter FTC often uses hardware redundancy; ITSC-FTC strategies remain relatively rare and mostly target torque-ripple or copper-loss reduction, with few limiting short-circuit current.
Methods
- Design: state-of-the-art review/survey; it compares itself with existing PMSM diagnostic surveys in Table I and organizes the literature by fault location and diagnostic method.
- Data or sample: no primary experimental sample; it analyzes published methods and presents tabular summaries (Tables II–X) for ITSC, demagnetization, bearing, eccentricity, unbalance, misalignment, converter, sensor faults, AI methods, and FTC.
- Main analysis: categorizes methods into frequency-domain, time-frequency, time-domain/statistical, model-based, control-structure-signal, and AI-based approaches, discussing advantages, disadvantages, and future trends.
Limitations
- Paper-stated: future challenges include diagnostics during transients, hardware implementation, failure prediction/prognostics, data storage and cloud transfer, multiple-fault diagnosis, AI/deep-learning development for PMSM drives, transfer learning, and real-time fault detection.
- Paper-stated: many PMSM fault diagnosis methods lack hardware implementation; deep neural networks are limited by structural complexity; few papers address ITSC-FTC and fault-current mitigation; control-structure-based mechanical fault diagnosis needs further work.
- Evident from the text: as a review, it reports no new experimental validation; some cited methods are simulation-only or inconclusive (e.g., DWT+NN bearing diagnosis in DTC is described as simulation-only and rather inconclusive), and the AI accuracy table is literature-derived rather than a controlled benchmark.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures

















Verification
Claims the paper makes
19 Valid · 20 Not valid · 149 Not checked · 149 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Greater sensitivity of this component to the stator winding fault compared to the FFT of the stator phase current is also emphasized.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Disputedcites [43] 43. P. Pietrzak and M. Wolkiewicz, "Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents," Energies, vol. 14, no. 6, p. 1630, Mar. 2021. sourceExperimental — accuracy not yet measured
Section 5 (page not provided) compares the fault indicators and identifies the 3fs component in the FFT spectrum of the stator phase current—not the 2fs component—as the most sensitive across the tested load-torque range. The Conclusions likewise describe both indicators as sensitive, without saying that 2fs is more sensitive. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
- Not matchedcites [45]- [47]
A range of references, not one source.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Partly supportedcites [20] 20. Y. Chen, S. Liang, W. Li, H. Liang, and C. Wang, "Faults and diagnosis methods of permanent magnet synchronous motors: A review." Applied Sciences, vol. 9, no. 10, art. 2116, Oct. 2019. sourceExperimental — accuracy not yet measured
Section 3.2.1 (Frequency Domain Methods) says that for an inter-turn short circuit, the most obvious feature is an increase in the third-harmonic amplitude, corresponding to 3fs. It does not establish that this is the greatest increase in magnitude among the components. (LLM, conf=0.83)
- Partly supportedcites [42] 42. M. Krzysztofiak, M. Skowron, and T. Orlowska-Kowalska, "Analysis of the Impact of Stator Inter-Turn Short Circuits on PMSM Drive with Scalar and Vector Control," Energies, vol. 14, no. 1, p. 153, Dec. 2020. sourceExperimental — accuracy not yet measured
Section 6 (Conclusions; page not available in our copy) reports that inter-turn short circuits increase the stator current’s 3fs harmonic and that its amplitude is much greater under field-oriented control than under scalar control. It does not establish that this is the greatest increase among fault-related components; the claim also omits the control-structure qualification. (LLM, conf=0.83)
- Supportedcites [43] 43. P. Pietrzak and M. Wolkiewicz, "Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents," Energies, vol. 14, no. 6, p. 1630, Mar. 2021. source
Section 6 (Conclusions; page not provided) calls the increase in the 3fs component’s amplitude the most significant symptom of stator-winding damage. Section 4.1 also reports a large increase in that component after an interturn short circuit. (LLM, conf=0.94)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In all of these papers, the Authors conclude that the increase of the 2fs component amplitude in the stator phase current space vector module spectrum is a symptom of a stator winding fault.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [43] 43. P. Pietrzak and M. Wolkiewicz, "Comparison of Selected Methods for the Stator Winding Condition Monitoring of a PMSM Using the Stator Phase Currents," Energies, vol. 14, no. 6, p. 1630, Mar. 2021. source
Section 2.2 states that, following an inter-turn short-circuit, the 2fs component increases in the FFT spectrum of the stator phase current space vector magnitude. This directly supports the attributed symptom of a stator winding fault. (LLM, conf=0.93)
- Not matchedcites [45]- [47]
A range of references, not one source.
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The limitation of this approach is mentioned in [60] to measure the ZSVC, the access to the neutral point of the stator winding is needed.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > A. FREQUENCY DOMAIN METHODS
What the sources say
- Supportedcites [60] 60. J. Fang, Y. Sun, Y. Wang, B. Wei and J. Hang, "Improved ZSVC-based fault detection technique for incipient stage inter-turn fault in PMSM," IET Electric Power Appl., vol. 13, no. 12, pp. 2015-2026, October 2019. source
The Conclusion explicitly states that an accessible neutral point of the stator windings is needed to measure the ZSVC. It also notes that this condition is met in a fault-tolerant PMSM drive system. (LLM, conf=0.95)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]- [146], [150], [151], [156]- [159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator inductance Ld [147], [148], BEMF [160] and unbalanced magnetic pull [153], [154]”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. ECCENTRICITY FAULTS
What the sources say
- Not checked — no full text of the sourcecites [135] 135. J. Rosero, J.L. Romeral, J. Cusido, J.A. Ortega, and A. Garcia, "Fault detection of eccentricity and bearing damage in a PMSM by means of wavelet transforms decomposition of the stator current", 2008 23 rd Ann. IEEE Appl. Power Electronics Conf. Exp., pp. 111-116, February 2008. source
- Not matchedcites [143]-[146]
A range of references, not one source.
- Supportedcites [150] 150. M. Karami, N. Mariun, M. Rezazadeh Mehrjou, M.Z.A. Ab Kadir, N. Misron, and M.A. Mohd Radzi, "Static eccentricity fault recognition in three-phase line start permanent magnet synchronous motor using finite element method", Mathematical Problems in Engineering, vol. 2014, Article ID 132647, 2014. source
This source is cited within the stator-current group of references, not for the entire list of signals. The Introduction identifies stator current as a prevalent monitored signal for motor fault detection, and Section 5 analyzes it for static eccentricity diagnosis in LSPMSMs. Page numbers are not available in our copy. (LLM, conf=0.93)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
150 more claims · 5 with their cited sources checked
Create a free account to see all 337 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 113
- Probably not a substantial claim. 91
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“The possibility of direct extraction of the input signal features in the diagnostics of PMSM stator windings faults has been described in [220], [222], [223], [229], [237].”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[237] + + CNN FFT IsABC”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > TABLE I COMPARISON OF THIS PAPER WITH EXISTING SURVEYS AND REVIEW PAPERS ON DIAGNOSTICS OF PMSM DRIVES
“[15] 2015 125 (120) 1997-2016”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“15. M. Cheng, J. Hang, and J.Zhang, "Overview of fault diagnosis theory and method for permanent magnet machine," Chinese Journal of Electrical Eng., vol. 1 no. 1, pp. 21-36, 2015..”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > IX. FAULT DETECTION OF PMSM DRIVE COMPONENTS AND FAULT-TOLERANT CONTROL A. FREQUENCY CONVERTER FAULTS
“The voltage-based method was also applied in [274] for open switch fault diagnosis in a voltage-oriented controlled AC/DC line side converter.”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > References
“274. M. Bourogaoui, H. B. A. Sethom, and I. S. Belkhodja. "Speed/position sensor fault tolerant control in adjustable speed drives -a review." ISA Transactions, vol. 64, pp. 269-284, 2016.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > B. SHALLOW NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + MLP DIRECT IsABC”
§ Fault diagnosis and fault-tolerant control of PMSM drivesstate of the art and future challenges > C. DEEP NEURAL NETWORKS APPLICATION IN PMSM DRIVES
“[216] + + MLP 98,50% (FFT) IsABC + Te + + MLP 96,10% (STAT) IsABC + Te”
Citations
Cites
Items 201–341 of 341
Pietrzak, P., & Wolkiewicz, M. (2021) · Energies · doi:10.3390/en14061630 · Cited by 40
Self-citationDiagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine
He, J., Somogyi, C., Strandt, A., & Demerdash, N. A. O. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953825 · Cited by 39
Lin, F., Zuo, S., & Deng, W. (2018) · Journal of Vibroengineering · doi:10.21595/jve.2017.18436 · Cited by 39
Jankowska, K. A., & Dybkowski, M. (2022) · Designs · doi:10.3390/designs6010018 · Cited by 39
A hybrid diagnosis method for inverter open-circuit faults in PMSM drives
Zhang, Z., Luo, G., Zhang, Z., & Tao, X. (2020) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2020.00023 · Cited by 39
Urresty, J.-C., Riba, J., Saavedra, H., & Romeral, L. (2011) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 39
Gritli, Y., Rossi, C., Casadei, D., Zarri, L., & Filippetti, F. (2012) · 2012 XXth International Conference on Electrical Machines · doi:10.1109/icelmach.2012.6350219 · Cited by 38 · cited 1×
“The work [105] proposes the application of WT to”
MethodNeural network based fault detection of PMSM stator winding short under load fluctuation
Quiroga, J., Cartes, D. A., Edrington, C. S., & Liu, L. (2008) · 2008 13th International Power Electronics and Motion Control Conference · doi:10.1109/epepemc.2008.4635364 · Cited by 38 · cited 6×
“ARTIFICIAL INTELLIGENCE-BASED METHODS OF PMSM FAULTS DETECTION – LITERATURE ANALYSIS No Fault category NN structure Preprocessing method Diagnostic signal 1 2 3 4 5 6 [120] + SOM FFT+ENV Vibrations [121] + MLP FFT+ENV Vibrations + RBF FFT+ENV Vibrations + SOM FFT+ENV Vibrations [214] + SOM CWT IsABC [215] + MLP SCA Is…”
BackgroundInfluentialSkowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12066 · Cited by 37
Self-citationNaseri, F., Schaltz, E., Lu, K., & Farjah, E. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1498 · Cited by 37 · cited 3×
“Moreover, this type of failure results in the degradation of the drive performance, which may lead to disastrous accidents in application requiring increased robustness, such as electric vehicles [252].”
BackgroundMethodWang, H., Zhao, W., Tang, H., Tao, T., & Saeed, S. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3099813 · Cited by 37
An open-circuit fault diagnosis method for PMSM drives using symmetrical and DC components
Huang, W., Du, J., Hua, W., & Fan, Q. (2021) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2021.000031 · Cited by 37
Stabilizing Sensorless Control Down to Zero Speed by Using the High-Frequency Current Amplitude
Szalai, T., Berger, G., & Petzoldt, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2279405 · Cited by 36 · cited 1×
“Moreover, speed estimation methods with increased accuracy in the range of low speeds, which combine classical observers with the HF injection methods [334], [335] can be used in FTC strategies.”
MethodHang, J., Zhang, J., Cheng, M., & Wang, Z. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647169 · Cited by 36 · cited 4×
“[165], [166] Stator current EPVA DWT Normalized energy NINV, TC, EV [165], CT HCC”
BackgroundMethodInfluentialCurrent sensors fault detection and tolerant control strategy for three-phase induction motor drives
Azzoug, Y., Sahraoui, M., Pusca, R., Ameid, T., Romary, R., & Cardoso, A. J. M. (2020) · Electrical Engineering · doi:10.1007/s00202-020-01120-5 · Cited by 36
Back-EMF Based Detection of Stator Winding Inter-turn Fault for PM Synchronous Motor Drives
Boileau, T., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544105 · Cited by 35 · cited 2×
“In [58] the second harmonic of active and reactive power spectrum is proposed as the FI independent on the motor control type.”
BackgroundNiu, J., Lu, S., Liu, Y., et al. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2883955 · Cited by 35
Change‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34 · cited 4×
“The models presented in the literature are described by differential equations, in a three-phase system A-B-C [42], [47], [83], [195], [196], [198], in a synchronous reference frame d-q for 3-phase motors [44], [72], [193], [194], [197], and also for multi-phase motors [213].”
MethodInfluentialKim, H.-K., Kang, D.-H., & Hur, J. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2439716 · Cited by 33
Wang, B., Wang, J., Griffo, A., & Huang, L. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908595 · Cited by 33 · cited 2×
“In order to limit the ITSC current, a strategy based on current injection technique was proposed for a triple redundant 3×3-phase PM synchronous reluctance machine [327].”
BackgroundMethodHe, Y., Zhang, Y., Xu, M., Wang, X., & Xiong, J. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2907450 · Cited by 33
Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33 · cited 5×
“According to [20], the greatest and most obvious increase in the case of this fault is the increase in the amplitude of the 3fs component, which has also been confirmed by the results presented by the authors in [42] and [43].”
BackgroundMethodResultSelf-citationMa, C., & Zuo, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301767 · Cited by 32
The Diagnosis Method of Stator Winding Faults in PMSMs Based on SOM Neural Networks
Cao, C., Zhang, W., Zhifu, W., & Li, Z. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.03.663 · Cited by 32 · cited 4×
“[121] + MLP 99,02% Vibrations + RBF 94,41% Vibrations + SOM 91,48% Vibrations [214] + SOM 93,30% IsABC [215] + MLP 99,37% IsABC”
BackgroundInfluentialInter-turn stator winding fault diagnosis and determination of fault percent in PMSM
Shamsinejad, M. A., & Taghipour, M. (2011) · IEEE Applied Power Electronics Colloquium (IAPEC) · doi:10.1109/iapec.2011.5779847 · Cited by 31
Karami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/132647 · Cited by 31 · cited 2×
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]-[146], [150], [151], [156]-[159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator i…”
BackgroundMethodCira, F., Arkan, M., Gumus, B., & Goktas, T. (2016) · IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2016.7793717 · Cited by 31 · cited 1×
“In [49] authors verified experimentally that both the current and the voltage negative sequence harmonics should be considered for accurate ITSC faults detection.”
BackgroundA sensorless PMSM drive using a two stage extended Kalman estimator
Akrad, A., Hilairet, M., & Diallo, D. (2008) · doi:10.1109/iecon.2008.4758398 · Cited by 30
Fault detection by means of wavelet transform in a PMSMW under demagnetization
Rosero, J., Romeral, L., Cusido, J., & Ortega, J. A. (2007) · IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2007.4460323 · Cited by 30 · cited 3×
“[102]-[104] CWT/DWT UDF, RS, RL, NINV, EV MS”
MethodImproved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30 · cited 2×
“The limitation of this approach is mentioned in [60] – to measure”
BackgroundStator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29 · cited 3×
“In [76] the stator phase current HHT and energy calculation is proposed for the detection of PMSM stator winding fault.”
BackgroundMethodAkar, M., Taşkın, S., ŞEKER, Ş. S., & Çankaya, İ. (2010) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.3906/elk-0911-298 · Cited by 29
Rosero, J., García, A., Cusidó, J., Romeral, L., & Ortega, J. A. (2007) · IEEE International Symposium on Intelligent Signal Processing, · doi:10.1109/wisp.2007.4447631 · Cited by 29
Galfarsoro, U., McCloskey, A., Zarate, S., et al. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3156075 · Cited by 29
Effect of Magnets Asymmetry on Stray Magnetic Flux Based Bearing Damage Detection in PMSM
Gurusamy, V., Baruti, K. H., Zafarani, M., Lee, W., & Akin, B. (2021) · IEEE Access · doi:10.1109/access.2021.3076779 · Cited by 28
Karami, M., Mariun, N., Kadir, M. Z. A. A., Misron, N., & Radzi, M. A. M. (2021) · Electric Power Components and Systems · doi:10.1080/15325008.2021.1937386 · Cited by 28
Quality Assurance Testing for Magnetization Quality Assessment of BLDC Motors Used in Compressors
Lee, K.-W., Hong, J., Lee, S. B., & Lee, S. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2075732 · Cited by 27
Permanent magnet synchronous machine stator windings fault detection by Hilbert–Huang transform
Alvarez‐Gonzalez, F., Griffo, A., & Wang, B. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8173 · Cited by 27
Mınaz, M. R., & Akcan, E. (2021) · IEEE Access · doi:10.1109/access.2021.3050418 · Cited by 26
Pietrzak, P., & Wolkiewicz, M. (2021) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc48073.2021.9432629 · Cited by 26
Self-citationGe, Y., Song, B., Pei, Y., Mollet, Y., & Gyselinck, J. J. C. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2878343 · Cited by 26
Guo, J., Lu, S., Zhai, C., & He, Q. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aa92d6 · Cited by 25
Dieterle, O., Greiner, T., & Heidrich, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835422 · Cited by 25 · cited 1×
“However, from the FTC point of view, the most commonly used motor structure includes multiphase and modular structures [314].”
Akar, M., Hekim, M., & Orhan, U. (2015) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.3906/elk-1210-58 · Cited by 24 · cited 6×
“ARTIFICIAL INTELLIGENCE-BASED METHODS OF PMSM FAULTS DETECTION – LITERATURE ANALYSIS No Fault category NN structure Preprocessing method Diagnostic signal 1 2 3 4 5 6 [120] + SOM FFT+ENV Vibrations [121] + MLP FFT+ENV Vibrations + RBF FFT+ENV Vibrations + SOM FFT+ENV Vibrations [214] + SOM CWT IsABC [215] + MLP SCA Is…”
BackgroundInfluentialCurrent Sensor Fault Diagnosis Based on a Sliding Mode Observer for PMSM Driven Systems
Huang, G., Luo, Y., Zhang, C., Huang, Y., & Zhao, K. (2015) · Sensors · doi:10.3390/s150511027 · Cited by 24 · cited 1×
“A model reference adaptive observer to estimate the phase current of PMSM by using the information of position, speed, and voltage in α-β frame was introduced in [293], whereas a SMOs were suggested to diagnose the CS faults of PMSM drive in [294] and [295].”
MethodA Digital Signal Processing Based Detection Circuit for Short-Circuit Protection of SiC MOSFET
Lee, S., Kim, K., Shim, M., & Nam, I. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3091679 · Cited by 24
Du, Y., Wu, L., Zhan, H., et al. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3051140 · Cited by 24
Diagnosis of Mechanical Unbalance Fault in Permanent Magnet Synchronous Machine Drives
Zhang, J., Hang, J., & Cheng, M. (2016) · Electric Power Components and Systems · doi:10.1080/15325008.2016.1169463 · Cited by 23
Khil, S. K. E., Jlassi, I., Estima, J. O., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062382 · Cited by 23 · cited 2×
“[254] IGBT Normalized residual analysis [255], [256] IGBT FI based on stator phase currents average”
MethodStudy of the Total Demagnetization Fault of an AFPM Wind Generator
Barmpatza, A. C., & Kappatou, J. C. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3021215 · Cited by 23
An effective method for detection of stator fault in PMSM with 1D-LBP
Mi̇naz, M. R. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.07.013 · Cited by 23
Sliding-Mode-Based Current and Speed Sensors Fault Diagnosis for Five-Phase PMSM
Bensalem, Y., Kouzou, A., Abbassi, R., Jerbi, H., Kennel, R. M., & Abdelrahem, M. (2021) · Energies · doi:10.3390/en15010071 · Cited by 23
Detection of magnet demagnetization in five-phase surface-mounted permanent magnet generators
Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., & Zarri, L. (2012) · 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254099 · Cited by 22 · cited 2×
“[179] or when the control structure is extended with some additional PI regulators to compensate for the damage [180]; – voltage decoupling signals, not applied in the diagnostics so far.”
BackgroundStator Short Circuits Detection in PMSM by means of Higher Order Spectral Analysis (HOSA)
Rosero, J., Ortega, J., Urresty, J., Cardenas, J., & Romeral, L. (2009) · 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2009.4802779 · Cited by 22 · cited 3×
“[65] MUSIC 3fs EV, ON, RL, RS Resolution is greater than MCSA.”
BackgroundMethodSensor fault diagnosis for improving the availability of electrical drives
Diao, S., Makni, Z., Bisson, J.-F., Diallo, D., & Marchand, C. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699625 · Cited by 21 · cited 1×
“A model reference adaptive observer to estimate the phase current of PMSM by using the information of position, speed, and voltage in α-β frame was introduced in [293], whereas a SMOs were suggested to diagnose the CS faults of PMSM drive in [294] and [295].”
MethodFault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Self-citationBearing Fault Detection of IPMSMs using Zoom FFT
Lee, J.-S., Yoon, T.-M., & Lee, K. (2016) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2016.11.5.1235 · Cited by 21
Lee, H., Jeong, H., & Kim, S. W. (2019) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec45492.2019.8994556 · Cited by 21
Doğan, Z., & Tetik, K. (2021) · IEEE Access · doi:10.1109/access.2021.3092605 · Cited by 21
Park, C. H., Lee, J., Ahn, G., Youn, M., & Youn, B. D. (2019) · 2019 IEEE 12th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864842 · Cited by 21
Machine Current Sensor FDI Strategy in PMSMs
Li, H., Qian, Y., Asgarpoor, S., & Sharif, H. (2019) · IEEE Access · doi:10.1109/access.2019.2950429 · Cited by 21
Tian, L., Wu, F., & Zhao, J. (2016) · Electronics Letters · doi:10.1049/el.2016.2713 · Cited by 20
Current sensors gain faults detection and isolation based on an adaptive observer for PMSM drives
Grouz, F., Sbita, L., & Boussak, M. (2013) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd.2013.6564061 · Cited by 20 · cited 1×
“The gain fault of CS was addressed in [301].”
BackgroundEKF-based fault diagnosis for open-phase faults of PMSM drives
Park, B.-G., Jinsu, J., Kim, T., & Hyun, D.-S. (2009) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2009.5157423 · Cited by 20 · cited 2×
“PARAMETER AND STATE OBSERVERS IN MOTOR DIAGNOSTICS Among the methods that use parameter estimators to detect PMSM motor failures, extended Kalman filters (EKF) are the most frequently used – to diagnose ITSC faults [188], [189], open phase failure [190] and demagnetization failure [191].”
MethodAhn, G., Lee, J., Park, C. H., Youn, M., & Youn, B. D. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864924 · Cited by 20
Artificial neural networks based fault detection in 3-Phase PMSM traction motor
Moosavi, S. S., Djerdir, A., Ait-Amirat, Y., & Kkuburi, D. A. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350089 · Cited by 19 · cited 2×
“26 VOLUME XX, 2017 [227] + MLP STAT IsABC + UsABC [228] + LSTM SCA IsABC [229] + CNN DIRECT IsABC [230] + + CNN FFT IsABC [231] + + MLP EWD IsABC [232] + + PNN VMD IsABC [233] + + CNN FFT IsABC [234] + MLP FFT+STAT IsABC [235] + MLP FFT IsABC [236] + BNN VKF-OT+WT Te [237] + + CNN FFT IsABC Fault categories: 1 – ITSCs…”
BackgroundIm, S.-H., & Gu, B.-G. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2941146 · Cited by 19
Guefack, F. L. T., Kiselev, A., & Kuznietsov, A. (2018) · 2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445403 · Cited by 19
Quantitative Fault Severity Estimation for High-Resistance Connection in PMSM Drive System
Hang, J., Yan, D., Xia, M., Ding, S., & Wang, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2901121 · Cited by 19
Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization
Casadei, D., Mengoni, M., Serra, G., Tani, A., & Zarri, L. (2011) · 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives · doi:10.1109/demped.2011.6063634 · Cited by 18 · cited 2×
“[97], [98] Zero sequence BEMF component FFT PDF, HS, ON SC, INV, AZP, AOF”
BackgroundMethodBearing fault detection in synchronous machine based on the statistical analysis of stator current
Picot, A., Obeid, Z., Regnier, J., Maussion, P., Poignant, S., & Darnis, O. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6389275 · Cited by 18
Multi-Condition PMSM Fault Diagnosis Based on Convolutional Neural Network Phase Tracker
Chen, Z., Liang, K., Peng, T., & Wang, Y. (2022) · Symmetry · doi:10.3390/sym14020295 · Cited by 18
Zhang, Y., Xiang, Z., Zhu, X., et al. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2020.3019295 · Cited by 18
Model-Based Hysteresis Loss Assessment in PMSMs With Ferrite Magnets
Egorov, D., Petrov, I., Link, J., et al. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714121 · Cited by 17 · cited 1×
“Authors of [202], [203], [204] performed an analysis of the effect of demagnetization on FEM model”
MethodDetection of Stator Short Circuits in PMSM by mean of joint Time-Frequency Analysis
Rosero, J., Cusidó, J., García, A., Romeral, L., & Ortega, J. A. (2007) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2007.4393131 · Cited by 17 · cited 1×
“[68] Stator current STFT RMS values of the local maxima EV, ON, RL, RS, TC, FL TR”
BackgroundAlvarez‐Gonzalez, F., Griffo, A., & Wang, B. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591661 · Cited by 17
An Indirect Testing Method for the Torque Ripple of Multiunit Permanent Magnet Synchronous Machines
Zeng, D., Zou, J., & Xu, Y. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908591 · Cited by 17
Wu, X., Huang, S., Liu, X., et al. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2717983 · Cited by 16 · cited 1×
“[330], [331] and HF signal injection, e.”
Shen, T., Kılıç, A., Thulfaut, C., & Reuss, H.-C. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915161 · Cited by 16
Bruno, A. L. O., Barros, C. M. V., Siebra, C., et al. (2019) · IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2019.8895013 · Cited by 16
(2021) · Journal of Applied Science and Engineering · doi:10.6180/jase.202104_24(2).0008 · Cited by 16
An Accurate Tool for Detecting Stator Inter-Turn Fault in LSPMSM
Maraaba, L. S., Al‐Hamouz, Z., & Abido, M. A. (2019) · IEEE Access · doi:10.1109/access.2019.2923812 · Cited by 15
Gao, F., Zhang, G., Li, M., Gao, Y., & Zhuang, S. (2020) · Energies · doi:10.3390/en13040899 · Cited by 15
Fault Diagnosis of Motor Bearing Based on Speed Signal Kurtosis Spectrum Analysis
Ren, B., Yang, M., Chai, N., Li, Y., & Xu, D. (2019) · 2019 22nd International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921477 · Cited by 15
Diagnosis and discernment between eccentricity and demagnetization faults in PMSM drives
Koura, M. B., Boudinar, A. H., Aimer, A. F., Bendiabdellah, A., & Gherabi, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-020-00204-6 · Cited by 15
Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558191 · Cited by 14
Adamczyk, M., & Orłowska-Kowalska, T. (2021) · Energies · doi:10.3390/en14206767 · Cited by 14
Self-citationEccentricity fault analysis in PMSM based marine propulsion motors
Ahsanullah, K., Jeyasankar, E., Vignesh, A., et al. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056162 · Cited by 14
Laamari, Y., Allaoui, S., Abdelmalik, A., & Saad, S. (2021) · Mathematical Modelling and Engineering Problems · doi:10.18280/mmep.080220 · Cited by 14
Hong, J., Lee, S. B., Kral, C., & Haumer, A. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063651 · Cited by 14
A Review of Fault Diagnosis Methods of Robot Joint Servo System
Wu, H. Q., & Feng, J. (2020) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma49215.2020.9233583 · Cited by 13
A Variable Speed Control of Permanent Magnet Synchronous Motor Without Current Sensors
Azzoug, Y., Sahraoui, M., Pusca, R., et al. (2020) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie45063.2020.9152572 · Cited by 13
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13 · cited 2×
“However, the instantaneous value of the angle between the reference voltage components has been directly used as an efficient FI in [181].”
MethodIntegrated prognosis of AC servo motor driven linear actuator using Hidden Semi-Markov models
Wu, X. Z., Li, Y., Guru, A. K., & Lundell, T. D. (2009) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2009.5075387 · Cited by 12 · cited 2×
“For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/ 2 VOLUME XX, 2017 HOT high order transform HT/HHT Hilbert/Hilbert-Huang transform IGBT insulated gate bipolar transistor IM induction motor IMF intrinsic mode functions IoT internet of Things IPMSM interior PM synchronous motor ITSC inter-tur…”
BackgroundInfluentialHong, J., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6064103 · Cited by 12
Zhang, G., Wang, G., Zhou, H., Li, C., Wang, G., & Xu, D. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721939 · Cited by 12
Fault diagnosis of wind turbine bearing using synchrosqueezing wavelet transform and order analysis
Jun, G., Wang, X., Zhai, C., Niu, J., & Lu, S. (2019) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2019.8833879 · Cited by 12
Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature
Mbo'o, C. P., & Hameyer, K. (2015) · 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303705 · Cited by 11 · cited 5×
“[116], [131], [132], [135]-[137] Stator current FFT fb =fs±kfu fu – characteristic failure frequency of the bearing k=1,2,3.”
BackgroundMethodInfluentialPhase-phase Short Fault Analysis of Permanent Magnet Synchronous Motor in Electric Vehicles
Wang, Z., Yang, J., Cao, C., & Zhong-li, G. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.06.112 · Cited by 11 · cited 4×
“The MLP network is characterized by an extremely simple mathematical description, thanks to which it is used in the case of mechanical damages: bearing damage [121, 231], eccentricity [231], and in the case of the damage to the stator electrical circuits [215-218], [224], [225], [232], supply voltage unbalance [219],…”
BackgroundMethodInfluentialEker, M., & Akar, M. (2017) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.3906/elk-1601-157 · Cited by 11 · cited 4×
“[158] AD-OT NINV, EV1, SC, TC, SE, DE, ME, RL, RS”
BackgroundMethodInfluentialA Model For Permanent Magnet Synchronous Machines With Demagnetization Faults
Ruschetti, C. R., Verucchi, C., Bossio, G. R., & García, G. O. (2013) · IEEE Latin America Transactions · doi:10.1109/tla.2013.6502839 · Cited by 10 · cited 2×
“14 VOLUME XX, 2017 [94]-[96] BEMF FFT PDF, NINV, AOF SC, OFF, MS”
MethodModelling and detection of bearing faults in Permanent Magnet Synchronous Motors
Rezig, A., N'Diaye, A., Mekideche, M. R., & Djerdir, A. (2012) · 2012 XXth International Conference on Electrical Machines · doi:10.1109/icelmach.2012.6350122 · Cited by 10
Senanayaka, J. S. L., Huynh, V. K., & Robbersmyr, K. G. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1037/3/032028 · Cited by 10
Finite Element Modeling of Stator Winding Faults in Permanent Magnet Synchronous Motor: Part II
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883937 · Cited by 10
Eccentricity Fault diagnosis in PMSM using Motor Current Signature Analysis
Gherabi, Z., Benouzza, N., Toumi, D., et al. (2019) · International Aegean Conference on Electrical Machines and Power Electronics & International Conference on Optimization of Electrical and Electronic Equipment (ACEMP-OPTIM) · doi:10.1109/acemp-optim44294.2019.9007164 · Cited by 10
Liu, X., Liang, D., Du, J., Yu, Y., Yang, X., & Luo, Z. (2014) · 2014 17th International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2014.7013721 · Cited by 9 · cited 1×
“[173] Torque Waveform plot EV, RL, RS SC, TW, PM”
BackgroundPMSM Model with Phase-to-Phase Short-Circuit and Diagnosis by ESA and EPVA
Bouchareb, C., & Naït‐Saïd, M. S. (2016) · Advances in Electrical and Electronic Engineering · doi:10.15598/aeee.v14i5.1928 · Cited by 9 · cited 2×
“The improvement and expansion of the analysis of stator phase current signals with FFT is presented in [43], [45]-[47].”
BackgroundSensorless harmonic speed control and detection of bearing faults in repetitive mechanical systems
Phung, V. T., & Pacas, M. (2017) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2017.7992294 · Cited by 9 · cited 1×
“Motor bearing inner- and outer-race faults can be distinguished using the approach shown in [177].”
Galfarsoro, U., McCloskey, A., Hernández, X., Almandoz, G., Zarate, S., & Arrasate, X. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864857 · Cited by 9
Jankowska, K., & Ewert, P. (2021) · Power Electronics and Drives · doi:10.2478/pead-2021-0008 · Cited by 9
Self-citationPietrzak, P., & Wolkiewicz, M. (2021) · Power Electronics and Drives · doi:10.2478/pead-2021-0004 · Cited by 9
Self-citationObeid, N. H., Battiston, A., Boileau, T., & Nahid‐Mobarakeh, B. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062352 · Cited by 8
Bavendiek, G., Müller, F., Steentjes, S., et al. (2019) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · doi:10.1002/jnm.2674 · Cited by 8
Angle misalignment detection and its suppression algorithm in rotor system based on speed signal
Huang, X., Yang, M., Ren, B., Chai, N., & Xu, D. (2020) · 2020 IEEE 9th International Power Electronics and Motion Control Conference (IPEMC2020-ECCE Asia) · doi:10.1109/ipemc-ecceasia48364.2020.9367852 · Cited by 8 · cited 4×
“[171], [174] Rotational speed FFT 2fr NINV, PM and AM [174] SC, RS, AM [171]”
BackgroundMethodInfluentialFinite Control Set MPC for Open-Phase Fault Tolerant Control of Synchronous Reluctance Motor
Kiselev, A., Catuogno, G. R., Kuznietsov, A., & Leidhold, R. (2020) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit45562.2020.9067220 · Cited by 8
Kommuri, S. K., Rath, J. J., Veluvolu, K. C., & Defoort, M. (2014) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2014.6987869 · Cited by 7
Galfarsoro, U., McCloskey, A., Zarate, S., et al. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270843 · Cited by 7
Fault Diagnosis of Permanent Magnet Synchronous Motor Based on Improved Probabilistic Neural Network
Dai, X., Zhang, Y., Qiao, L., et al. (2021) · Chinese Control Conference (CCC) · doi:10.23919/ccc52363.2021.9550728 · Cited by 7
Faults and Diagnosis Systems in Power Converters
Lee, K.-B., & Choi, U.-M. (2014) · Studies in Computational Intelligence · doi:10.1007/978-3-319-03401-0_4 · Cited by 6 · cited 13×
“Diagnostic symptom Method [240], [241] ESR calculation on-line AC current injection (in q axis) Indirect DC-link capacitor current estimation Direct measurement of DC-link and capacitor voltage ESR estimation with RLS method [242], [240] ESR calculation off-line Capacitor model Hardware measurement In the case of algo…”
BackgroundMethodInfluentialRefaat, S. S., Abu‐Rub, H., Saad, M., et al. (2013) · IEEE GCC Conference and Exhibition (GCCCE) · doi:10.1109/ieeegcc.2013.6705817 · Cited by 6 · cited 4×
“The MLP network is characterized by an extremely simple mathematical description, thanks to which it is used in the case of mechanical damages: bearing damage [121, 231], eccentricity [231], and in the case of the damage to the stator electrical circuits [215-218], [224], [225], [232], supply voltage unbalance [219],…”
BackgroundMethodInfluentialFault detection, isolation and reconfiguration of three-phase AC drive with current sensor fault
Meinguet, F., & Gyselinck, J. J. C. (2011) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2011.5994846 · Cited by 6 · cited 1×
“In [287], the FDD method with additional current sensors (five in total) is applied.”
MethodOpen switch fault diagnosis methods for an AC/DC line-side converter
Sobański, P., & Orłowska-Kowalska, T. (2017) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2017.7915604 · Cited by 6 · cited 4×
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundMethodInfluentialSelf-citationDemagnetisation fault detection in PMSM using zero sequence current components
Ding, S., Hang, J., Li, H., & Wang, Q. (2017) · Electronics Letters · doi:10.1049/el.2016.2600 · Cited by 6 · cited 5×
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
BackgroundMethodInfluentialSlimen, S. B., Bourogaoui, M., & Sethom, H. B. A. (2016) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem.2016.8066801 · Cited by 6
Modelling of Permanent Magnet Synchronous Generator with Non-linear Magnets
Ibrayeva, A., Lopez, F., & Eriksson, S. (2021) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit46573.2021.9453675 · Cited by 6
Chai, N., Yang, M., Ren, B., Huang, X., & Xu, D. (2020) · 2020 IEEE 9th International Power Electronics and Motion Control Conference (IPEMC2020-ECCE Asia) · doi:10.1109/ipemc-ecceasia48364.2020.9367979 · Cited by 6 · cited 2×
“[171], [174] Rotational speed FFT 2fr NINV, PM and AM [174] SC, RS, AM [171]”
BackgroundMethodApplication of selected higher-order methods to detect rotor unbalance of drive system with PMSM
Ewert, P., & Jaworski, M. (2021) · 2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC) · doi:10.1109/pemc48073.2021.9432610 · Cited by 6 · cited 3×
“In [163], selected higher order methods for detecting the unbalance of a PMSM drive system are presented.”
MethodSelf-citationA voltage based approach for fault detection and separation in permanent magnet synchronous machines
Haddad, R. Z., Lopez, C. A., Foster, S. N., & Strangas, E. G. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854806 · Cited by 6
D-Q current signature based single winding open fault detection for SM-PMAC machine drives
Kuruppu, S. S., & Kulatunga, N. A. (2013) · 2013 International Electric Machines & Drives Conference · doi:10.1109/iemdc.2013.6556310 · Cited by 5 · cited 3×
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
MethodIGBT open-circuit fault diagnosis based on the current prediction in the line-side AC/DC converter
Sobański, P., & Orłowska-Kowalska, T. (2017) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2017.7913068 · Cited by 5 · cited 3×
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundSelf-citationRotor Unbalance Fault Diagnosis in Wind Turbine by Markov Chain Monte Carlo Method
Corbalan, P., & Chiang, L. E. (2021) · doi:10.21203/rs.3.rs-493595/v1 · Cited by 4 · cited 3×
“In [168] and [169] the detection of the unbalance in PMSG is discussed.”
BackgroundImproved Rotating Speed Estimation and Bearing Fault Diagnosis Using Multi-Channel Vibration Signals
Wang, X., Niu, J., Lu, S., et al. (2020) · International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD) · doi:10.1109/icsmd50554.2020.9261718 · Cited by 4
Quality Assurance Testing for Magnetization Quality Assessment of BLDC Motors used in Compressors
Lee, K., Hong, J., Lee, S. B., & Lee, S.-T. (2009) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2009.5324825 · Cited by 4
Detecting eccentricity faults in a PMSM in non-stationary conditions
García, J. R., Romeral, J. L., & Rosero, E. (2012) · Ingeniería e Investigación · doi:10.15446/ing.investig.v32n1.28512 · Cited by 3 · cited 4×
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]-[146], [150], [151], [156]-[159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator i…”
BackgroundMethodInfluentialFaults detection in PMSM drive using Artificial Neural Network
Urbański, K. (2017) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2017.06.06 · Cited by 3 · cited 5×
“ARTIFICIAL INTELLIGENCE-BASED METHODS OF PMSM FAULTS DETECTION – LITERATURE ANALYSIS No Fault category NN structure Preprocessing method Diagnostic signal 1 2 3 4 5 6 [120] + SOM FFT+ENV Vibrations [121] + MLP FFT+ENV Vibrations + RBF FFT+ENV Vibrations + SOM FFT+ENV Vibrations [214] + SOM CWT IsABC [215] + MLP SCA Is…”
MethodInfluentialWu, Z., Niu, J., Lu, S., Liu, Y., & Liu, F. (2020) · International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD) · doi:10.1109/icsmd50554.2020.9261722 · Cited by 3
(2006) · doi:10.1007/3-540-30368-5_12 · Cited by 3
IGBT open-circuit fault diagnosis based on the voltage estimation in the line-side AC/DC converter
Sobański, P., & Orłowska-Kowalska, T. (2017) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2017.8001527 · Cited by 3
The frequency response of parallel misalignment in PMSM test bench
Liu, X., Liang, D., Ze, Q., & Yu, Y. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8002242 · Cited by 2 · cited 1×
“In [175], the frequency response of the tested PMSM drive with parallel misalignment was analyzed, while in [176] it was shown in simulations and in experimental tests that the virtual phase torque (VPT) diagram method based on self-”
MethodGao, C., Gao, M., Si, J., et al. (2019) · Applied Sciences · doi:10.3390/app9173599 · Cited by 2
YINQUAN, Y. (2014) · National University of Singapore · Cited by 2
Research works printed but not linked: 8
- 17. M. Krichen, N. Benhadj, M. Chaieb, and R. Neji, "Fault Detection and Diagnosis Methods in Permanent Magnet Synchronous Machines: A Review, " Int. Conf. Recent Adv. Electrical Syst. (ICRAES'17), Dec. 2017.
- 131. P. Varal, V. Patole, S. Shinde, P. Deshmukh, and D. Srivastava, "Bearing Fault Analysis of Permanent Magnet Synchronous Motor (PMSM) using Current Signature Analysis", Int. Research Journal of Engineering and Technology, vol. 4, no. 4, pp. 410-415, 2017.
- 134. A.H. Abbas, A.A. Al-Saffar, and D.K. Shary, "Bearings fault diagnosis in direct torque control permanent magnet synchronous motor based on discrete wavelet transform and artificial neural network", Int. Journal of Advances in Eng. & Technology, vol. 7, no. 2, pp. 341-351, 2014.
- 193. F. Meinguet, E. Semail,X. Kestelyn, Y. Mollet, and J. Gyselinck, "Change-detection algorithm for short-circuit fault detection in closed-loop AC drives," IET Electric Power Applications, vol. 8, no. 5, pp. 165-177, May 2014. · DOI · Paper page
- 194. M. A. Mazzoletti, G. R. Bossio, C. H. De Angelo, and D. R. Espinoza-Trejo, "A Model-Based Strategy for Interturn Short- Circuit Fault Diagnosis in PMSM," IEEE Trans. Ind. Electron., vol. 64, no. 9, pp. 7218-7228, Sept. 2017. · DOI · Paper page
- 211. S. Moon, H. Jeong, H. Lee, and S. W. Kim, "Interturn Short Fault Diagnosis in a PMSM by Voltage and Current Residual Analysis With the Faulty Winding Model," IEEE Trans. Energy Conv., vol. 33, no. 1, pp. 190-198, March 2018. · DOI · Paper page
- 325. J. Zhang, W. Zhan and M. Ehsani, "Fault-tolerant control of PMSM with inter-turn short-circuit fault," IEEE Trans. Energy Convers., vol. 34, no. 4, pp. 2267-2275, Dec. 2019. · DOI · Paper page
- 339. TERESA ORLOWSKA-KOWALSKA (M'93- SM'05) received the Ph.D. and D.Sc. degrees in electrical engineering from Wroclaw University of Technology (WUT), Wroclaw, Poland, in 1976 and 1990, respectively. Since 1993, she has been a Professor of electrical engineering (since 2004 - Full Professor) and the Head of the Electrical Drives Control Chair at the Faculty of Electrical Engineering, WUT. In the period 2002-2019 she has been the Director of the Institute of Electrical Machines, Drives, and Measurements, WUT. She is the author of over 400 journal papers and Conf. proceedings, two textbooks, two books, and fifty chapters in monographs. Her research interests include controlled electrical drives, applications of the observer theory and artificial intelligence methods in sensorless control of AC drives, control methods of the drive systems with elastic couplings, diagnostics and fault-tolerant control methods for AC drives. Prof. Orlowska-Kowalska is a member of the Electrical Engineering Committee of the Polish Academy of Science (since 1996), the Council of Provosts of IV Division of the Polish Academy of Science (2011-2018), and International Steering Committees of a few well-known conferences. In the period 2004-2014 she has been an Associate Editor for the IEEE Transactions on Industrial Electronics. She is a member of Editorial Boards of a few international journals and Editor-in-Chief of Power Electronics and Drives journal. She serves as a reviewer of many IEEE, IET, Elsevier, Springer, Taylor & Francis, MDPI, SAGE and other journals.
Cited by
Pietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
“Damage to PMs can be divided into mechanical damage of the PM (cracks, chipping) and those associated with the phenomenon of demagnetization [1,8].”
BackgroundSelf-citationCheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 80
El-Dalahmeh, M., Al‐Greer, M., Bashir, I., El‐Dalahmeh, M., Demirel, A., & Keysan, O. (2023) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2023.108894 · Cited by 73
Mueller, P. N., Woelfl, L., & Can, S. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.106834 · Cited by 58
Fault Diagnosis of Electric Motors by a Channel-Wise Regulated CNN and Differential of STFT
Mohammad‐Alikhani, A., Jamshidpour, E., Dhale, S., Akrami, M., Pardhan, S., & Nahid‐Mobarakeh, B. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3532556 · Cited by 53
Metadata
- Authors
- Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T.
- Affiliations
- Department of Electrical Machines, Drives and Measurements, Wrocław University of Science and Technology, Wrocław, Poland
- Wrocław University of Science and Technology (PL)
- ORCID
- Venue
- IEEE Access
- Published
- 2022
- Volume
- 10
- Pages
- 59979-60024
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4285271556
- Semantic Scholar
- dc069ddc2dd7fed25b6db8df368599dab4ad9d8b
- Cited by
- 328
- References
- 335
- Citations by year
- 2026: 72 · 2025: 112 · 2024: 81 · 2023: 52 · 2022: 11
- FWCI
- 21.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- IEEE Access (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Science Centre Poland (2017/27/B/ST7/00816)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- permanent magnet synchronous motor, fault diagnosis, fault-tolerant control, motor drives, stator winding faults, bearing defects, rotor faults, power converter faults, sensor faults, artificial neural networks, safety-critical systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-06, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-06 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.