Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice
Open accessAbstract
Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work toward putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Models that require a single calibration cuff measurement are convenient but potentially less accurate than those that use multiple measurements to form a patient-specific calibration curve”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [20]
In the citing paper
“Pulse wave propagation delay between the genders indicates baseline differences in arterial stiffness with women displaying lower degrees of pulse arrival latency delay indicating higher vascular stiffness [106,107].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [106]
In the citing paper
“New devices that promise to change the current paradigm of hypertension monitoring use either inflating wristband cuffs (e.g., Omron HeartGuide, currently undergoing clinical testing) or optical pulse wave-based metrics of BP [75,76].”
From Wearables and the Medical Revolution (2018) · cites this paper as [76]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“A number of effective R-wave detection methods have been described, with the most popular being the Pan and Tomp-kins method [156].”
MethodExpert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077 · cited 2×
“…1) reliably estimate aortic PWV in order to assess cardiovascular risk independent of BP more conveniently than traditionally employed tonometry [126]; 2) track BP changes (rather than BP levels) to help control BP in patients with known hypertension; and 3) indicate whether BP levels are not…”
BackgroundMethodPhotoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 3×
“The advantage of reflectance-mode PPG is that it is less restrictive in terms of measurement locations [66], [67], [69].”
BackgroundMethodBurt, V. L., Whelton, P., Roccella, E. J., Brown, C., Cutler, J. A., Higgins, M., Horan, M. J., & Labarthe, D. (1995) · Hypertension · doi:10.1161/01.hyp.25.3.305 · Cited by 2,998 · cited 1×
“Hypertension is a major cardiovascular risk factor that is treatable, yet high BP detection and control rates are abysmally low, especially in low resource settings [1], [2].”
BackgroundAnderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · cited 1×
“Infrared (IR) and red optical wavelengths should be used for transmission-mode PPG due to the “optical water window” [66] and higher tissue penetration depth [66], [67], [74].”
MethodLakatta, E. G., & Levy, D. (2003) · Circulation · doi:10.1161/01.cir.0000048892.83521.58 · Cited by 2,244 · cited 1×
“We similarly hypothesized the model from reviews [24], [25], in vitro animal studies [32], [34], an in vivo animal study [35], an in vitro human study [36], and an in vivo human study [33].”
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,085
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · cited 1×
“Flexible strain or pressure sensors placed over a superficial artery can measure waveforms indicative of BP via the tonometric principle [109]–[112].”
BackgroundHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C. M., Flack, J. M., Frohlich, E. D., Hill, M. D., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,592 · cited 1×
“Auscultation is the standard clinical method [7].”
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M., McDuff, D., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,514
Research works printed but not linked: 9
- 10.1016/0161-7346(79)90028-2 · DOI
- costanzo, 2003, Physiology
- froelicher, 2006, Exercise and the Heart
- katz, 2010, Physiology of the Heart
- patterson, 0, Development of an electrical impedance plethysmography system to monitor cardiac output, Proc 1st Annu Rocky Mountain Bioeng Symp, 56
- o’brien, 1993, The British hypertension society protocol for the evaluation of blood pressure measuring devices, J Hypertension, 11, 43s
- 2014, Standard for Wearable Cuffless Blood Pressure Measuring Devices
- 1993, Electronic or Automated Sphygmomanometers
- eckerle, 1988, Tonometry arterial, Encyclopedia of Medical Devices and Instrumentation
Cited by
Sorted by citations
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654
“, Omron HeartGuide, currently undergoing clinical testing) or optical pulse wave-based metrics of BP [75,76].”
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
“where P0 , P1 , and Am are varying among individuals [7].”
BackgroundMethodInfluentialBlood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387
“The PTT approach was thoroughly tested in the past 10 years [15,16] and a number of slight variations were proposed, however, the underlying principle remains unchanged.”
BackgroundSelf-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
“Pulse wave propagation delay between the genders indicates baseline differences in arterial stiffness with women displaying lower degrees of pulse arrival latency delay indicating higher vascular stiffness [106,107].”
BackgroundEl-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 300
Novel Methods for Pulse Wave Velocity Measurement
Pereira, T., Correia, C. M. B. A., & Cardoso, J. M. R. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0086-8 · Cited by 284
“However, major progress on the algorithms to determine the BP using the PWV measurement is still required, like the calibration of pulse transit time (PTT, in units of ms) to BP (in units of mmHg) [21].”
BackgroundOptical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 263
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Management of Hypertension in the Digital Era
Kario, K. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14742 · Cited by 247
Stergiou, G. S., Mukkamala, R., Avolio, A. P., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R. G., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 231
“Copyright © 2022 Wolters Kluwer preejectionperiod variations and smoothmuscle contraction mediated by varying sympathetic nervous activity and local mechanisms in the distal arm arteries [49].”
BackgroundCuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211
A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China
Liang, Y., Chen, Z., Liu, G., & Elgendi, M. (2018) · Scientific Data · doi:10.1038/sdata.2018.20 · Cited by 215
Dieffenderfer, J., Goodell, H., Mills, S., McKnight, M., Yao, S., Lin, F., Beppler, E., Bent, B., Lee, B., Misra, V., et al. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2573286 · Cited by 212
Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method
Chandrasekhar, A., Kim, C., Naji, M. B., Natarajan, K., Hahn, J., & Mukkamala, R. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8674 · Cited by 208
Ding, X., Yan, B. P., Zhang, Y., Liu, J., Zhao, N., & Tsang, H. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-11507-3 · Cited by 208
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 233
Kim, K., Choi, J., Jeong, Y., Cho, I., Kim, M., Kim, S., Oh, Y. S., & Park, I. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900978 · Cited by 186
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Huynh, T. H., Jafari, R., & Chung, W. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2865751 · Cited by 181
“In other words, the difference between SBP and DBP becomes large with increasing distance from the heart [1].”
BackgroundMethodInfluentialPhotoplethysmography and Deep Learning: Enhancing Hypertension Risk Stratification
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Biosensors · doi:10.3390/bios8040101 · Cited by 176
Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera
Jeong, I. C., & Finkelstein, J. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0439-z · Cited by 161
Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
Nabeel, P. M., Kiran, V. R., Joseph, J., Abhidev, V. V., & Sivaprakasam, M. (2019) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2019.2931587 · Cited by 168
“They are equally vital in applications such as cuffless BP measurement [11].”
BackgroundMethodInfluentialEsmaili, A., Kachuee, M., & Shabany, M. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2745081 · Cited by 155
“Among common interventions proposed in the literature for perturbing BP [12], [22]–[26], here, physical exercise is employed, since it has been shown to cause a sensible increase in both SBP and DBP up to 40 mmHg [27].”
BackgroundWearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“Summary: Cuff-based oscillometric devices are widely used, technologically robust, and have high accuracy [116], [117].”
BackgroundKim, C., Carek, A. M., Mukkamala, R., Inan, O. T., & Hahn, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2440291 · Cited by 155
“(see, for example, recent reviews on this topic [3], [4]).”
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102301 · Cited by 156
Miao, F., Wen, B., Hu, Z., Fortino, G., Wang, X., Liu, Z.-D., Tang, M., & Li, Y. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101919 · Cited by 150
Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Liu, J., Yan, B. P., Zhang, Y., Ding, X., Su, P., & Zhao, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 139
“To minimize the need of cuff for wearable BP measurement, the photoplethysmography (PPG)-based approach has attracted much attention [8]–[19].”
Li, H., Ma, Y., Liang, Z., Wang, Z., Cao, Y. K., Xu, Y., Zhou, H., Lu, B., Chen, Y., Han, Z., et al. (2020) · National Science Review · doi:10.1093/nsr/nwaa022 · Cited by 143
“Photoplethysmogram (PPG) detected by optical methods can be used for PTTmeasurement [42,43], while only one parameter PTTcannot give both systolic and diastolic blood pressure [11,44].”
MethodA review of wearable and unobtrusive sensing technologies for chronic disease management
Guo, Y., Liu, X., Peng, S., Jiang, X., Xu, K., Chen, C., Wang, Z., Dai, C., & Chen, W. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104163 · Cited by 146
Multi-Sensor Fusion Approach for Cuff-Less Blood Pressure Measurement
Miao, F., Liu, Z.-D., Liu, J., Wen, B., He, Q., & Li, Y. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2901724 · Cited by 137
“Two common technologies to measure pulse wave including photoplethysmography (i.e., PPG signal) and pressure sensing (i.e., PPW signal).”
BackgroundInfluentialContinuous PPG-Based Blood Pressure Monitoring Using Multi-Linear Regression
Haddad, S., Boukhayma, A., & Caizzone, A. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3128229 · Cited by 145
“Since the time interval starts from the R-peak of the ECG, the PAT includes both the PTT and the cardiac pre-ejection period (PEP) [16].”
MethodMonitoring vital signs over multiplexed radio by near-field coherent sensing
Hui, X., & Kan, E. C.-C. (2017) · Nature Electronics · doi:10.1038/s41928-017-0001-0 · Cited by 140
A Wearable Tele-Health System towards Monitoring COVID-19 and Chronic Diseases
Jiang, W., Majumder, S., Kumar, S., Subramaniam, S., Li, X., Khedri, R., Mondal, T. K., Abolghasemian, M., Satia, I., & Deen, M. J. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3069815 · Cited by 140
“from one arterial site to another [107].”
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“PTT is related to blood pressure [23], and can be used to calculate pulse wave velocity (PWV), a marker of cardiovascular risk [24].”
BackgroundMartin, S. L.-O., Carek, A. M., Kim, C., Ashouri, H., Inan, O. T., Hahn, J., & Mukkamala, R. (2016) · Scientific Reports · doi:10.1038/srep39273 · Cited by 131
Hypertension Assessment via ECG and PPG Signals: An Evaluation Using MIMIC Database
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Diagnostics · doi:10.3390/diagnostics8030065 · Cited by 132
“Therefore, the morphological information of PPG could be used to assess hypertension [6].”
MethodCuffless blood pressure estimation from PPG signals and its derivatives using deep learning models
El-Hajj, C., & Kyriacou, P. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102984 · Cited by 140
Zhang, Q., Zhou, D., & Zeng, X. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0317-z · Cited by 132
“Currently, the ECG signal is usually measured using a single- or multiple-lead configuration, referring to or modified from the traditional standard 12-lead configuration which can provide strong ECG signals with highly distinguishable morphologies [2, 3].”
BackgroundInfluentialBlood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar
Buxi, D., Jean-Michel, R., & Yuce, M. R. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2582472 · Cited by 123
“These are not expected to be affected by the smooth muscle contraction and surrounding tissue as the peripheral arteries would be [11].”
BackgroundInfluentialPramanik, P. K. D., Upadhyaya, B. K., Pal, S., & Pal, T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-815368-0.00001-4 · Cited by 122
Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring
Zhao, L., Liang, C., Huang, Y., Zhou, G., Xiao, Y., Ji, N., Zhang, Y., & Zhao, N. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00835-6 · Cited by 137
Franklin, D., Tzavelis, A., Lee, J. Y., Chung, H. U., Trueb, J. T., Arafa, H., Kwak, S. S., Huang, I. A., Liu, Y., Rathod, M., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01098-y · Cited by 119
Sharifi, I., Goudarzi, S., & Khodabakhshi, M. B. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2018.12.005 · Cited by 115
End-to-End Blood Pressure Prediction via Fully Convolutional Networks
Baek, S., Jang, J.-Y., & Yoon, S. (2019) · IEEE Access · doi:10.1109/access.2019.2960844 · Cited by 126
Zhang, Q., Zeng, X., Hu, W. W., & Zhou, D. (2017) · IEEE Access · doi:10.1109/access.2017.2707472 · Cited by 113
“Many investigations in wearable BP monitoring have been reported and summarized in several recently published surveys [2], [3].”
BackgroundMethodResultInfluentialWearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113
PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement
Chandrasekhar, A., Yavarimanesh, M., Natarajan, K., Hahn, J., & Mukkamala, R. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2976989 · Cited by 123
“PPG: waveform analysis [10] and pulse transit time (PTT) [1], [11].”
InfluentialDefinition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111
Konijnenburg, M., Stanzione, S., Yan, L., Jee, D., Pettine, J., van Wegberg, R., Kim, H. J., van Liempd, C., Fish, R., Schuessler, J., et al. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2605660 · Cited by 111
“12 shows the results where the PAT could be accurately calculated from an ECG signal and a PPG signal, allowing the system to determine the blood pressure.”
MethodInfluentialAguirre, N. A., Grall‐Maës, E., Cymberknop, L. J., & Armentano, R. L. (2021) · Sensors · doi:10.3390/s21062167 · Cited by 115
“Nevertheless, PAT is widely used by researchers as a good approximation of PTT, mainly due to the ease of its measurement [13].”
BackgroundIbrahim, B., & Jafari, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2946661 · Cited by 108
Holz, C., & Wang, E. J. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3132024 · Cited by 106
Kim, C., Carek, A. M., Inan, O. T., Mukkamala, R., & Hahn, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2797239 · Cited by 110
Conventional pulse transit times as markers of blood pressure changes in humans
Block, R., Yavarimanesh, M., Natarajan, K., Carek, A. M., Mousavi, A. S., Chandrasekhar, A., Kim, C., Zhu, J., Schifitto, G., Mestha, L. K., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-73143-8 · Cited by 107
A novel art of continuous noninvasive blood pressure measurement
Fortin, J., Rogge, D. E., Fellner, C., Flotzinger, D., Grond, J., Lerche, K., & Saugel, B. (2021) · Nature Communications · doi:10.1038/s41467-021-21271-8 · Cited by 104
Carek, A. M., Conant, J., Joshi, A. N., Kang, H., & Inan, O. T. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3130905 · Cited by 103
Cuffless blood pressure estimation using only a smartphone
Matsumura, K., Rolfe, P. J., Toda, S., & Yamakoshi, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-25681-5 · Cited by 102
Wang, W., Mohseni, P., Kilgore, K. L., & Najafizadeh, L. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3128383 · Cited by 109
Wang, E. J., Zhu, J., Jain, M., Lee, T.-J., Saba, E., Nachman, L., & Patel, S. (2018) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173999 · Cited by 103
“Various methods have been proposed to determine the calibration between PTT and BP [16].”
BackgroundMethodInfluentialCuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
Ganti, V. G., Carek, A. M., Nevius, B. N., Heller, J. A., Etemadi, M., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3021532 · Cited by 101
“linear models can have better accuracy, they tend to contain more than two unknown variables which dictates the need for more PTT and BP calibration points [6].”
InfluentialSmets, E., Raedt, W. D., & Hoof, C. A. V. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2883751 · Cited by 110
“However, recent advances in ambulant BP measurement based on the combination of ECG and PPG measurements through pulse transit time analysis, should allow ubiquitous BP measurements in the future [52].”
BackgroundMethodInfluentialPeng, C., Chen, M., Sim, H. K., Zhu, Y., & Jiang, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3021923 · Cited by 99
“Oscillometric method is the most popular noninvasive, automatic method for blood pressure monitoring [14]–[16].”
MethodBoosting the Battery Life of Wearables for Health Monitoring Through the Compression of Biosignals
Hooshmand, M., Zordan, D., Testa, D. D., Grisan, E., & Rossi, M. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2689164 · Cited by 99
“13 and 14 we respectively show the RMSE vs CE performance for PPG and respiratory (RESP) signals from the PhysioNet MIMIC-II waveform database [74].”
MethodInfluentialHypertension Assessment Using Photoplethysmography: A Risk Stratification Approach
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm8010012 · Cited by 99
“Meanwhile, arterial wave propagation theory [16] and PPG morphological theory have also been researched: The former is based on ECGs or other physiological signals and the PPG signal, while the latter is based on PPG morphological features.”
BackgroundGonzález, S., Hsieh, W., & Chen, T. P.-C. (2023) · Scientific Data · doi:10.1038/s41597-023-02020-6 · Cited by 99
“Many studies have shown interest in extending the use of PPG to BP monitoring 5–7 .”
BackgroundMethodMieloszyk, R. J., Twede, H., Lester, J., Wander, J., Basu, S., Cohn, G., Smith, G., Morris, D., Gupta, S., Tan, D., et al. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3153259 · Cited by 101
“Cuffless BP devices allow for indirect BP measurement by leveraging hemodynamic phenomena that are known to change in conjunction with changes in BP [28], specifically pulse wave velocity and morphological characteristics of the pulsatile pressure or volume waveform in the arterial tree.”
BackgroundMethodInfluentialXing, X., Ma, Z., Zhang, M., Zhou, Y., Dong, W., & Song, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-45175-2 · Cited by 101
Pulse arrival time as a surrogate of blood pressure
Finnegan, E., Davidson, S. M., Harford, M., Jorge, J., Watkinson, P., Young, D., Tarassenko, L., & Villarroel, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-01358-4 · Cited by 105
A Chair–Based Unobtrusive Cuffless Blood Pressure Monitoring System Based on Pulse Arrival Time
Tang, Z., TAMURA, T., Sekine, M., Huang, M., Chen, W., Yoshida, M., Sakatani, K., Kobayashi, H., & Kanaya, S. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2614962 · Cited by 91
“Although thesewearable BPmeasurement systemsmake it possible to perform ambulatory BP measurement, there are still shortcomings that need to be improved, such as discomfort of wear, restriction on activities, and hydrostatic effects on accuracy due to changes of measurement postures [10], [11], [15].”
BackgroundLiang, Y., Abbott, D., Howard, N., Lim, K. I., Ward, R. K., & Elgendi, M. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8030337 · Cited by 94
Rong, M., & Li, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102328 · Cited by 89
Javaid, A. Q., Ashouri, H., Dorier, A., Etemadi, M., Heller, J. A., Roy, S., & Inan, O. T. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2600945 · Cited by 88
“, cardiac output and systolic time intervals (STIs) [3]), blood pressure [4], and vascular health (e.”
BackgroundGao, M., Olivier, N. B., & Mukkamala, R. (2016) · Physiological Reports · doi:10.14814/phy2.12768 · Cited by 86
“As outlined in (Mukkamala et al. 2015), few studies have assessed noninvasive PTT estimates as markers of BP over a wide physiological BP range.”
BackgroundMethodResultInfluentialSelf-citationCuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time
Yoon, Y.-Z., Kang, J. M., Kwon, Y., Park, S., Noh, S., Kim, Y., Park, J., & Hwang, S. W. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2714674 · Cited by 90
“However, the variances of each parameter correlation to BP were larger, because each subject has different higher correlated parameters to BP. aPWA T1 −0.23 ± 0.33 −0.17 ± 0.37 −0.20 ± 0.35 −0.20 ± 0.29 T2 −0.09 ± 0.36 −0.20 ± 0.36 −0.15 ± 0.42 0.01 ± 0.32 Tn 0.00 ± 0.30 0.16 ± 0.35 0.08 ± 0.33 −0.12 ± 0.29 Tmax −0.22…”
BackgroundInfluentialDevelopment and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device
Watanabe, N., Bando, Y., Kawachi, T., Yamakita, H., Futatsuyama, K., Honda, Y., Yasui, H., Nishimura, K., Kamihara, T., Okumura, T., et al. (2017) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2017.07.015 · Cited by 88
“For cuff-less BP monitoring to be user-friendly (11), the use of multiple sensors should not limit portability or flexibility.”
BackgroundMukkamala, R., & Hahn, J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2756018 · Cited by 86
“However, smooth muscle contraction is a significantly greater factor in the periphery [1].”
BackgroundMethodInfluentialBi-Modal Arterial Compliance Probe for Calibration-Free Cuffless Blood Pressure Estimation
Nabeel, P. M., Joseph, J., Srinivasa, K., Sivaprakasam, M., & Chenniappan, M. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2866332 · Cited by 83
“In this approach, BP estimation is often performed using theoretical or heuristic regressionmodels that relate transit time estimates such as pulse arrival time (PAT), pulse transit time (PTT), and pulse wave velocity (PWV) with arterial pressure [9], [10].”
MethodCuff-Less Methods for Blood Pressure Telemonitoring
Bard, D. M., Joseph, J. I., & van Helmond, N. (2019) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2019.00040 · Cited by 84
Gurel, N. Z., Huang, M., Wittbrodt, M. T., Jung, H., Ladd, S. L., Shandhi, M. M. H., Ko, Y., Shallenberger, L. H., Nye, J. A., Pearce, B. D., et al. (2019) · Brain stimulation · doi:10.1016/j.brs.2019.08.002 · Cited by 87
“This is an interesting result considering the relationship of PPG and BP waveforms [56,83].”
Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters
Carlson, C., Turpin, V. G., Suliman, A., Ade, C. J., Warren, S., & Thompson, D. E. (2020) · Sensors · doi:10.3390/s21010156 · Cited by 90
“The average correlation coefficient for PAT-estimated systolic blood pressure was 0.48 +/− 0.25.”
BackgroundMethodInfluentialBarvik, D., Černý, M., Penhaker, M., & Noury, N. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3109643 · Cited by 85
The Microsoft Research Aurora Project: Important Findings on Cuffless Blood Pressure Measurement
Mukkamala, R., Shroff, S. G., Landry, C., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2022) · Hypertension · doi:10.1161/hypertensionaha.122.20410 · Cited by 82
Continuous Non-Invasive Blood Pressure Monitoring: A Methodological Review on Measurement Techniques
Le, T., Ellington, F., Lee, T.-Y., Vo, K., Khine, M., Krishnan, S. K., Dutt, N. D., & Cao, H. (2020) · IEEE Access · doi:10.1109/access.2020.3040257 · Cited by 84
“, physical exercises, valsalva maneuvers, and cold pressor) deployed that would perturb an individual’s BP and resulted in large variations of BP values induced by a set of interventions [9].”
BackgroundMethodInfluentialIbrahim, B., & Jafari, R. (2022) · Scientific Reports · doi:10.1038/s41598-021-03612-1 · Cited by 86
Estimating blood pressure trends and the nocturnal dip from photoplethysmography
Radha, M., de Groot, K., Rajani, N. B., Wong, C. C. P., Kobold, N., Vos, V., Fonseca, P. M., Mastellos, N., Wark, P. A., Velthoven, N., et al. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab030e · Cited by 90
“The main track of research is based on the Moens-Korteweg equations, which relate the propagation velocity of the blood pulse within arteries to BP [6,37,41].”
BackgroundMethodWearable Millimeter-Wave Device for Contactless Measurement of Arterial Pulses
Johnson, J. E., Shay, O., Kim, C., & Liao, C. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2948581 · Cited by 78
“Much of the work in this area involves measuring arterial pulsations to obtain a high-quality pulse signal with minimal artifacts [6] and then”
BackgroundRastegar, S., GholamHosseini, H., & Lowe, A. (2019) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-019-00813-x · Cited by 83
Zheng, Y., Poon, C. C. Y., Yan, B. P., & Lau, J. Y. W. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0558-6 · Cited by 82
Nabeel, P. M., Jayaraj, J., & Sivaprakasam, M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9550 · Cited by 80
Gurel, N. Z., Wittbrodt, M. T., Jung, H., Shandhi, M. M. H., Driggers, E. G., Ladd, S. L., Huang, M., Ko, Y., Shallenberger, L. H., Beckwith, J., et al. (2020) · Neurobiology of Stress · doi:10.1016/j.ynstr.2020.100264 · Cited by 82
“PEP is responsive to tasks requiring effortful active coping (Kelsey, 2012), similar to the speech task, N.Z. Gurel et al. Neurobiology of Stress 13 (2020) 100264 potentially indicating tcVNS helps to recover increased cardiac contractility.”
BackgroundInfluentialFinnegan, E., Davidson, S. M., Harford, M., Watkinson, P., Tarassenko, L., & Villarroel, M. (2023) · Scientific Reports · doi:10.1038/s41598-022-27170-2 · Cited by 87
An Accurate Bioimpedance Measurement System for Blood Pressure Monitoring
Huynh, T. H., Jafari, R., & Chung, W. (2018) · Sensors · doi:10.3390/s18072095 · Cited by 80
“Another reason is that detection points at the peak may be more accurate than the middle and the foot points, as can be seen in the ensemble average BI waveforms [1].”
BackgroundLin, W.-H., Wang, H., Samuel, O. W., Liu, G., Huang, Z., & Li, G. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaa454 · Cited by 78
“…can be approximately calculated as the time interval from a character point of electrocardiogram (ECG) to a character point of photoplethysmogram (PPG), and was also named as pulse arrival time (PAT) in some other studies (Payne et al 2006, Solà et al 2013, Mukkamala et al 2015, Martin et al 2016).”
ResultMaqsood, S., Xu, S., Tran, S. N., Garg, S., Springer, M., Karunanithi, M., & Mohawesh, R. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.116788 · Cited by 83
Metadata
- Authors
- Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S.
- Affiliations
- Michigan State University (US)
- University of Maryland, College Park (US)
- Georgia Institute of Technology (US)
- Palo Alto Research Center (US)
- Corresponding author
- Mukkamala, Ramakrishna
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-08
- Volume
- 62
- Issue
- 8
- Pages
- 1879-1901
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- PMC
- PMC4515215
- OpenAlex
- W2294418644
- Cited by
- 935
- References
- 212
- Citations by year
- 2026: 92 · 2025: 93 · 2024: 96 · 2023: 89 · 2022: 93 · 2021: 87 · 2020: 84 · 2019: 92 · 2018: 83 · 2017: 71 · 2016: 50 · 2015: 4
- FWCI
- 34.44
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health (U01 EB018818)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- blood pressure monitoring, pulse transit time, ubiquitous health monitoring, wearable sensors, hypertension detection, non-invasive blood pressure estimation
- MeSH terms
- Blood Pressure, Blood Pressure Determination, Clothing, Equipment Design, Humans, Signal Processing, Computer-Assisted, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review