The DOI matches its Crossref record.
A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age
Abstract
The longitudinal (T1) and transverse (T2) hydrogen (1 H) nuclear magnetic resonance (NMR) relaxation times of normal human and animal tissue in the frequency range 1–100 MHz are compiled and reviewed as a function of tissue type, NMR frequency, temperature, species, in vivo versus in vitro status, time after excision, and age. The dominant observed factors affecting T1 are tissue type and NMR frequency (ν). All tissue frequency dispersions can be fitted to the simple expression T1=A νB in the range 1–100 MHz, with A and B tissue‐dependent constants. This equation provides as good or better fit to the data as previous more complex formulas. T2 is found to be multicomponent, essentially independent of NMR frequency, and dependent mainly on tissue type. Mean and raw values of T1 and T2 for each tissue are tabulated and/or plotted versus frequency and the fitting parameters A, B and the standard deviations determined to establish the normal range of relaxation times applicable to NMR imaging. The mechanisms for tissue NMR relaxation are reviewed with reference to the fast exchange two state (FETS) model of water in biological systems, and an overview of the dynamic state of water and macromolecular hydrogen compatible with the frequency, temperature, and multicomponent data is postulated. This suggests that 1 H tissue T1 is determined predominantly by intermolecular (possibly rotational) interactions between macromolecules and a single bound hydration layer, and the T2 is governed mainly by exchange diffusion of water between the bound layer and a free water phase. Deficiencies in measurement techniques are identified as major sources of data irreproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Rieke, V., & Butts Pauly, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21265 · Cited by 1,108
Adaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Peterfy, C. G., Schneider, E., & Nevitt, M. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.06.016 · Cited by 684
Piechnik, S. K., Ferreira, V. M., Dall'Armellina, E., Cochlin, L. E., Greiser, A., Neubauer, S., & Robson, M. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-69 · Cited by 670
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21122 · Cited by 652
The development of brain white matter microstructure
Lebel, C., & Deoni, S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.097 · Cited by 602
“The most historical of these measures are the longitudinal and transverse relaxation times (T1 and T2, respectively) (Bottomley et al., 1984).”
BackgroundHall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Aletras, A. H., Tilak, G. S., Natanzon, A., Hsu, L.-Y., Gonzalez, F. M., Hoyt, R. F., & Arai, A. E. (2006) · Circulation · doi:10.1161/circulationaha.105.576025 · Cited by 532
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 517
Quantitative MR Imaging of Brain Iron: A Postmortem Validation Study
Langkammer, C., Krebs, N., Goessler, W., Scheurer, E., Ebner, F., Yen, K., Fazekas, F., & Ropele, S. (2010) · Radiology · doi:10.1148/radiol.10100495 · Cited by 507
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Le Bihan, D., Delannoy, J., & Levin, R. L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717764 · Cited by 493
Automatic tumor segmentation using knowledge-based techniques
Clark, M. C., Hall, L. O., Goldgof, D. B., Velthuizen, R., Murtagh, F. R., & Silbiger, M. S. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700731 · Cited by 461
Ferreira, V. M., Piechnik, S. K., Dall'Armellina, E., Karamitsos, T. D., Francis, J. M., Choudhury, R. P., Friedrich, M. G., Robson, M. D., & Neubauer, S. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-42 · Cited by 460
Lifespan maturation and degeneration of human brain white matter
Yeatman, J. D., Wandell, B. A., & Mezer, A. A. (2014) · Nature Communications · doi:10.1038/ncomms5932 · Cited by 432
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
Myocardial T1 mapping: Application to patients with acute and chronic myocardial infarction
Messroghli, D. R., Walters, K., Plein, S., Sparrow, P., Friedrich, M. G., Ridgway, J. P., & Sivananthan, M. U. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21272 · Cited by 351
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325
Cardiac SSFP imaging at 3 Tesla
Schär, M., Kozerke, S., Fischer, S. E., & Boesiger, P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20024 · Cited by 307
High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo
de Graaf, R. A., Brown, P. B., McIntyre, S., Nixon, T. W., Behar, K. L., & Rothman, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20946 · Cited by 304
Le Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Mezer, A., Yeatman, J. D., Stikov, N., Kay, K. N., Cho, N.-J., Dougherty, R. F., Perry, M. L., Parvizi, J., Hua, L. H., Butts-Pauly, K., et al. (2013) · Nature Medicine · doi:10.1038/nm.3390 · Cited by 282
Piechnik, S. K., Ferreira, V. M., Lewandowski, A. J., Ntusi, N. A., Banerjee, R., Holloway, C., Hofman, M. B., Sado, D. M., Maestrini, V., White, S. K., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-13 · Cited by 273
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B. (2009) · RadioGraphics · doi:10.1148/rg.291075123 · Cited by 271
Clinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Gelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
A low-cost and shielding-free ultra-low-field brain MRI scanner
Liu, Y., Leong, A. T. L., Zhao, Y., Xiao, L., Mak, H. K. F., Tsang, A. C. O., Lau, G. K. K., Leung, G. K. K., & Wu, E. X. (2021) · Nature Communications · doi:10.1038/s41467-021-27317-1 · Cited by 261
The vertical occipital fasciculus: A century of controversy resolved by in vivo measurements
Yeatman, J. D., Weiner, K. S., Pestilli, F., Rokem, A., Mezer, A., & Wandell, B. A. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1418503111 · Cited by 258
An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing
Zur, Y., Stokar, S., & Bendel, P. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060206 · Cited by 253
Wisnieff, C., Ramanan, S., Olesik, J., Gauthier, S., Wang, Y., & Pitt, D. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25420 · Cited by 245
Cortical maturation and myelination in healthy toddlers and young children
Deoni, S. C. L., Dean, D. C., Remer, J., Dirks, H., & O’Muircheartaigh, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.058 · Cited by 221
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Effects of formalin fixation and temperature on MR relaxation times in the human brain
Birkl, C., Langkammer, C., Golob‐Schwarzl, N., Leoni, M., Haybaeck, J., Goessler, W., Fazekas, F., & Ropele, S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3477 · Cited by 111
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Metadata
- Authors
- Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1984-07
- Volume
- 11
- Issue
- 4
- Pages
- 425-448
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2011435635
- Cited by
- 1,192
- References
- 0
- FWCI
- 24.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.