Flexible and Stretchable Electronics for Biointegrated Devices
The DOI matches its Crossref record; 95 of the 98 references it cites were found in a registry or an index.
Abstract
Advances in materials, mechanics, and manufacturing now allow construction of high-quality electronics and optoelectronics in forms that can readily integrate with the soft, curvilinear, and time-dynamic surfaces of the human body. The resulting capabilities create new opportunities for studying disease states, improving surgical procedures, monitoring health/wellness, establishing human-machine interfaces, and performing other functions. This review summarizes these technologies and illustrates their use in forms integrated with the brain, the heart, and the skin.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health1–12.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [10]
In the citing paper
“Although the PVDF modulus is 3.6 GPa, our previous studies revealed that orders of magnitude reduction in stiffness and maximum intrinsic strain could be achieved when stiff films are patterned into serpentine ribbons.23”
From A Chest‐Laminated Ultrathin and Stretchable E‐Tattoo for the Measurement of Electrocardiogram, Seismocardiogram, and Cardiac Time Intervals (2019) · cites this paper as [23]
In the citing paper
“The soft mechanics and thin geometry enabled soft, nonirritating intimate contact with the skin through principles similar to those established for epidermal electronics (2, 36).”
From A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat (2016) · cites this paper as [36]
Citations
Cites
Studies of interference in serial verbal reactions
Stroop, J. R. (1935) · Journal of Experimental Psychology · doi:10.1037/h0054651 · Cited by 18,622
Yu, G., Gao, J., Hummelen, J. C., Wudl, F., & Heeger, A. J. (1995) · Science · doi:10.1126/science.270.5243.1789 · Cited by 10,348
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Cramming More Components onto Integrated Circuits (1965)
Moore, G. (2021) · Ideas That Created the Future · doi:10.7551/mitpress/12274.003.0027 · Cited by 6,241
The path to ubiquitous and low-cost organic electronic appliances on plastic
Forrest, S. R. (2004) · Nature · doi:10.1038/nature02498 · Cited by 5,165
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationKim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Efficient Tandem Polymer Solar Cells Fabricated by All-Solution Processing
Kim, J. Y., Lee, K., Coates, N. E., Moses, D., Nguyen, T.-Q., Dante, M., & Heeger, A. J. (2007) · Science · doi:10.1126/science.1141711 · Cited by 3,270
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
A Stretchable Form of Single-Crystal Silicon for High-Performance Electronics on Rubber Substrates
Khang, D.-Y., Jiang, H., Huang, Y., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1121401 · Cited by 1,689
Self-citationStretchable and Foldable Silicon Integrated Circuits
Kim, D.-H., Ahn, J.-H., Choi, W. M., Kim, H.-S., Kim, T.-H., Song, J., Huang, Y. Y., Liu, Z., Lu, C., & Rogers, J. A. (2008) · Science · doi:10.1126/science.1154367 · Cited by 1,676
Self-citationFlexible active-matrix displays and shift registers based on solution-processed organic transistors
Gelinck, G. H., Huitema, H. E. A., van Veenendaal, E., Cantatore, E., Schrijnemakers, L., van der Putten, J. B. P. H., Geuns, T. C. T., Beenhakkers, M., Giesbers, J. B., Huisman, B.-H., et al. (2004) · Nature Materials · doi:10.1038/nmat1061 · Cited by 1,582
Transfer printing by kinetic control of adhesion to an elastomeric stamp
Meitl, M. A., Zhu, Z.-T., Kumar, V., Lee, K. J., Feng, X., Huang, Y. Y., Adesida, I., Nuzzo, R. G., & Rogers, J. A. (2006) · Nature Materials · doi:10.1038/nmat1532 · Cited by 1,548
Self-citationSolid state electronic devices
Streetman, B. G. (1972) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,475
A hemispherical electronic eye camera based on compressible silicon optoelectronics
Ko, H. C., Stoykovich, M. P., Song, J., Malyarchuk, V., Choi, W. M., Yu, C.-J., Geddes III, J. B., Xiao, J., Wang, S., Huang, Y., et al. (2008) · Nature · doi:10.1038/nature07113 · Cited by 1,352
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Self-citationRogers, J. A., Bao, Z., Baldwin, K., Dodabalapur, A., Crone, B., Raju, V. R., Kuck, V., Katz, H., Amundson, K., Ewing, J., et al. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.091588098 · Cited by 1,117
Self-citationPerlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Controlled buckling of semiconductor nanoribbons for stretchable electronics
Sun, Y., Choi, W. M., Jiang, H., Huang, Y. Y., & Rogers, J. A. (2006) · Nature Nanotechnology · doi:10.1038/nnano.2006.131 · Cited by 933
Self-citationProgrammable polymer thin film and non-volatile memory device
Ouyang, J., Chu, C.-W., Szmanda, C. R., Ma, L., & Yang, Y. (2004) · Nature Materials · doi:10.1038/nmat1269 · Cited by 883
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Printed Assemblies of Inorganic Light-Emitting Diodes for Deformable and Semitransparent Displays
Park, S.-I., Xiong, Y., Kim, R.-H., Elvikis, P., Meitl, M., Kim, D.-H., Wu, J., Yoon, J., Yu, C.-J., Liu, Z., et al. (2009) · Science · doi:10.1126/science.1175690 · Cited by 852
Self-citationThree-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Kim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
Self-citationPentacene-based radio-frequency identification circuitry
Baude, P. F., Ender, D. A., Haase, M. A., Kelley, T. W., Muyres, D. V., & Theiss, S. D. (2003) · Applied Physics Letters · doi:10.1063/1.1579554 · Cited by 755
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Kim, D.-H., Song, J., Choi, W. M., Kim, H.-S., Kim, R.-H., Liu, Z., Huang, Y. Y., Hwang, K.-C., Zhang, Y.-W., & Rogers, J. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807476105 · Cited by 737
Self-citationA direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Synthesis, assembly and applications of semiconductor nanomembranes
Rogers, J. A., Lagally, M. G., & Nuzzo, R. G. (2011) · Nature · doi:10.1038/nature10381 · Cited by 715
Self-citationHeterogeneous Three-Dimensional Electronics by Use of Printed Semiconductor Nanomaterials
Ahn, J.-H., Kim, H.-S., Lee, K. J., Jeon, S., Kang, S. J., Sun, Y., Nuzzo, R. G., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1132394 · Cited by 693
Self-citationMapping and Ablation of Idiopathic Ventricular Fibrillation
Haïssaguerre, M., Shoda, M., Jaïs, P., Nogami, A., Shah, D. C., Kautzner, J., Arentz, T., Kalushe, D., Lamaison, D., Griffith, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027564.55739.b1 · Cited by 686
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Self-citationGaAs photovoltaics and optoelectronics using releasable multilayer epitaxial assemblies
Yoon, J., Jo, S., Chun, I. S., Jung, I., Kim, H.-S., Meitl, M., Menard, E., Li, X., Coleman, J. J., Paik, U., et al. (2010) · Nature · doi:10.1038/nature09054 · Cited by 617
Self-citationOrganic-Based Photovoltaics: Toward Low-Cost Power Generation
Shaheen, S. E., Ginley, D. S., & Jabbour, G. E. (2005) · MRS Bulletin · doi:10.1557/mrs2005.2 · Cited by 552
A 13.56-MHz RFID System Based on Organic Transponders
Cantatore, E., Geuns, T. C. T., Gelinck, G. H., van Veenendaal, E., Gruijthuijsen, A. F. A., Schrijnemakers, L., Drews, S., & de Leeuw, D. M. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886556 · Cited by 504
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Worrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 458
Kim, S., Wu, J., Carlson, A., Jin, S. H., Kovalsky, A., Glass, P., Liu, Z., Ahmed, N., Elgan, S. L., Chen, W., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005828107 · Cited by 442
Self-citationA Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, J., Kim, D.-H., Moss, J. D., Kim, Y.-S., Blanco, J. A., Annetta, N., Hicks, A., Xiao, J., Huang, Y., Callans, D. J., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000738 · Cited by 420
Self-citationCompeting Fracture in Kinetically Controlled Transfer Printing
Feng, X., Meitl, M. A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2007) · Langmuir · doi:10.1021/la701555n · Cited by 411
Self-citationBiaxially Stretchable “Wavy” Silicon Nanomembranes
Choi, W. M., Song, J., Khang, D.-Y., Jiang, H., Huang, Y. Y., & Rogers, J. A. (2007) · Nano Letters · doi:10.1021/nl0706244 · Cited by 406
Self-citationKim, D., Kim, Y., Wu, J., Liu, Z., Song, J., Kim, H., Huang, Y. Y., Hwang, K., & Rogers, J. A. (2009) · Advanced Materials · doi:10.1002/adma.200900405 · Cited by 403
Self-citationDrake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Flexible polymeric dry electrodes for the long-term monitoring of ECG
Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S.-H. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.11.019 · Cited by 340
Microseizures and the spatiotemporal scales of human partial epilepsy
Stead, M., Bower, M., Brinkmann, B. H., Lee, K., Marsh, W. R., Meyer, F. B., Litt, B., Van Gompel, J., & Worrell, G. A. (2010) · Brain · doi:10.1093/brain/awq190 · Cited by 311
Spiral Wave Dynamics in Neocortex
Huang, X., Xu, W., Liang, J., Takagaki, K., Gao, X., & Wu, J.-Y. (2010) · Neuron · doi:10.1016/j.neuron.2010.11.007 · Cited by 308
Catheter Ablation for Ventricular Tachycardia
Stevenson, W. G., & Soejima, K. (2007) · Circulation · doi:10.1161/circulationaha.106.655720 · Cited by 299
Dynamically tunable hemispherical electronic eye camera system with adjustable zoom capability
Jung, I., Xiao, J., Malyarchuk, V., Lu, C., Li, M., Liu, Z., Yoon, J., Huang, Y., & Rogers, J. A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015440108 · Cited by 289
Self-citationUnusual strategies for using indium gallium nitride grown on silicon (111) for solid-state lighting
Kim, H.-S., Brueckner, E., Song, J., Li, Y., Kim, S., Lu, C., Sulkin, J., Choquette, K., Huang, Y., Nuzzo, R. G., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1102650108 · Cited by 250
Self-citationTechnology Insight: neuroengineering and epilepsy—designing devices for seizure control
Stacey, W. C., & Litt, B. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0750 · Cited by 234
Technology and metrology of new electronic materials and devices
Vogel, E. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.142 · Cited by 193
Optimized Structural Designs for Stretchable Silicon Integrated Circuits
Kim, D., Liu, Z., Kim, Y., Wu, J., Song, J., Kim, H., Huang, Y., Hwang, K., Zhang, Y., & Rogers, J. A. (2009) · Small · doi:10.1002/smll.200900853 · Cited by 184
Self-citationRole of subdural electrocorticography in prediction of long-term seizure outcome in epilepsy surgery
Asano, E., Juhász, C., Shah, A., Sood, S., & Chugani, H. T. (2009) · Brain · doi:10.1093/brain/awp025 · Cited by 175
Mack, S., Meitl, M. A., Baca, A. J., Zhu, Z.-T., & Rogers, J. A. (2006) · Applied Physics Letters · doi:10.1063/1.2206688 · Cited by 174
Self-citationHigh-speed mechanically flexible single-crystal silicon thin-film transistors on plastic substrates
Ahn, J.-H., Kim, H.-S., Lee, K. J., Zhu, Z., Menard, E., Nuzzo, R. G., & Rogers, J. A. (2006) · IEEE Electron Device Letters · doi:10.1109/led.2006.874764 · Cited by 169
Self-citationGriffith, R. W., & Humphrey, D. R. (2006) · Neuroscience Letters · doi:10.1016/j.neulet.2006.07.018 · Cited by 167
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
DI BIASE, L., NATALE, A., BARRETT, C., TAN, C., ELAYI, C. S., CHING, C. K., WANG, P., AL‐AHMAD, A., ARRUDA, M., BURKHARDT, J. D., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01355.x · Cited by 163
Deep Brain Stimulation for Epilepsy
Halpern, C. H., Samadani, U., Litt, B., Jaggi, J. L., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.065 · Cited by 151
Characterization of micromachined spiked biopotential electrodes
Griss, P., Tolvanen-Laakso, H. K., Merilainen, P., & Stemme, G. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1001974 · Cited by 149
Reddy, V. Y., Neužil, P., d’Ávila, A., Laragy, M., Malchano, Z. J., Královec, Š., Kim, S. J., & Ruskin, J. N. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.11.006 · Cited by 149
Visually-Guided Balloon Catheter Ablation of Atrial Fibrillation
Reddy, V. Y., Neužil, P., Themistoclakis, S., Danik, S. B., Bonso, A., Rossillo, A., Raviele, A., Schweikert, R. A., Ernst, S., Kück, K., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.840587 · Cited by 144
Acquisition, Processing and Analysis of the Surface Electromyogram
Gerdle, B. U. C., Karlsson, S. J., Day, S. J., & Djupsjöbacka, M. (1999) · Springer eBooks · doi:10.1007/978-3-642-58552-4_26 · Cited by 140
Baca, A. J., Meitl, M. A., Ko, H. C., Mack, S., Kim, H. ‐., Dong, J., Ferreira, P. M., & Rogers, J. A. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601161 · Cited by 134
Self-citationSun, Y., & Rogers, J. A. (2007) · Journal of Materials Chemistry · doi:10.1039/b614793c · Cited by 123
Self-citationLight Emission Characteristics and Mechanics of Foldable Inorganic Light‐Emitting Diodes
Park, S., Le, A., Wu, J. C., et al. (2010) · Advanced Materials · doi:10.1002/adma.201000591 · Cited by 116
Self-citationSchmidt, B., Antz, M., Ernst, S., Ouyang, F. O., Falk, P., Chun, J., & Kück, K. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.01.017 · Cited by 114
First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
Ruffini, G., Dunne, S., Fuentemilla, L., Grau, C., Farrés, E., Marco-Pallarés, J., Watts, P. C. P., & Silva, S. R. P. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.03.007 · Cited by 113
Optoelectronic Devices and Material Technologies for Photo-Electronic Integrated Systems
Hayashi, I. (1993) · Japanese Journal of Applied Physics · doi:10.1143/jjap.32.266 · Cited by 108
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Bulk Quantities of Single-Crystal Silicon Micro-/Nanoribbons Generated from Bulk Wafers
Ko, H. C., Baca, A. J., & Rogers, J. A. (2006) · Nano Letters · doi:10.1021/nl061846p · Cited by 102
Self-citationMicro-spike EEG electrode and the vacuum-casting technology for mass production
Ng, W. C., Seet, H. L., Lee, K. S., et al. (2008) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2008.10.051 · Cited by 100
A Microelectrode/Microelectronic Hybrid Device for Brain Implantable Neuroprosthesis Applications
Patterson, W. R., Song, Y.-K., Bull, C. W., Ozden, I., Deangellis, A. P., Lay, C., McKay, J. L., Nurmikko, A. V., Donoghue, J. D., & Connors, B. W. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831521 · Cited by 100
The other transistor: early history of the metal-oxide semiconductor field-effect transistor
Arns, R. G. (1998) · Engineering Science and Education Journal · doi:10.1049/esej:19980509 · Cited by 99
Kim, T., Choi, W. M., Kim, D., Meitl, M. A., Menard, E., Jiang, H., Carlisle, J. A., & Rogers, J. A. (2008) · Advanced Materials · doi:10.1002/adma.200702434 · Cited by 98
Self-citationKim, D., Ahn, J., Kim, H., Lee, K. J., Kim, T., Yu, C., Nuzzo, R. G., & Rogers, J. A. (2008) · IEEE Electron Device Letters · doi:10.1109/led.2007.910770 · Cited by 94
Self-citationAhn, J., Kim, H., Menard, E., Lee, K. J., Zhu, Z., Kim, D., Nuzzo, R. G., Rogers, J. A., Amlani, I., Kushner, V. A., et al. (2007) · Applied Physics Letters · doi:10.1063/1.2742294 · Cited by 80
Self-citationNeuroprotective effect of FK506, an immunosuppressant, on transient global ischemia in gerbil
Tokime, T., Nozaki, K., & Kikuchi, H. (1996) · Neuroscience Letters · doi:10.1016/s0304-3940(96)12438-1 · Cited by 76
State-of-the-art and emerging technologies for atrial fibrillation ablation
Dewire, J., & Calkins, H. G. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2009.232 · Cited by 73
Feedback of Speech Muscle Activity during Silent Reading: Rapid Extinction
Hardyck, C. D., Petrinovich, L. F., & Ellsworth, D. W. (1966) · Science · doi:10.1126/science.154.3755.1467 · Cited by 73
Cryoballoon Pulmonary Vein Isolation with Real‐Time Recordings from the Pulmonary Veins
Chun, K. R. J., Fürnkranz, A., Metzner, A., Schmidt, B., Tilz, R. R., Zerm, T., Köster, I., Nuyens, D., Wißner, E., Ouyang, F. O., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01549.x · Cited by 71
Evaluation of Catheter Ablation of Periatrial Ganglionic Plexi in Patients With Atrial Fibrillation
Danik, S., Neužil, P., d’Ávila, A., Malchano, Z. J., Královec, Š., Ruskin, J. N., & Reddy, V. Y. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.04.064 · Cited by 64
Tokuda, T., Pan, Y., Uehara, A., Kagawa, K., Nunoshita, M., & Ohta, J. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.03.065 · Cited by 57
Usefulness of a New Radiofrequency Thermal Balloon Catheter for Pulmonary Vein Isolation:
Satake, S., Tanaka, K., Saito, S., et al. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02577.x · Cited by 47
Micropatterned dry electrodes for brain–computer interface
Matteucci, M., Carabalona, R., Casella, M., et al. (2007) · Microelectronic Engineering · doi:10.1016/j.mee.2007.01.243 · Cited by 44
MANSOUR, M. C., Forleo, G. B., Pappalardo, A., Heist, E. K., Avella, A., Laurenzi, F., Girolamo, P. D., Bencardino, G., Russo, A. D., Mantica, M., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.08.024 · Cited by 40
A 13.56MHz RFID System based on Organic Transponders
Cantatore, E., Geuns, T. C. T., Gruijthuijsen, A. F. A., et al. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696147 · Cited by 31
A 2.4-GHz Low-Power/Low-Voltage Wireless Plug-and-Play Module for EEG Applications
Carmo, J. P., Dias, N. S., Silva, H. R., Mendes, P. M., Couto, C., & Correia, J. H. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.908238 · Cited by 23
Advances in catheter ablation for the treatment of cardiac arrhythmias
Greenspon, A. J. (2000) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.899029 · Cited by 9
Research works printed but not linked: 3
- Moore G., 1965, Electronics, 38, 114
- Interwoven W., 1901, Arch. Neerl. Sc. Ex. Nat., 6, 625
- Chun KR, 2009, J. Cardiovasc. Electrophysiol., 30, 699
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Metadata
- Authors
- Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A.
- Affiliations
- Seoul National University (KR)
- MC10 (United States) (US)
- The University of Texas at Austin (US)
- University of Illinois Urbana-Champaign (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2012-08-15
- Volume
- 14
- Issue
- 1
- Pages
- 113-128
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2160524585
- Semantic Scholar
- 0c08bb354f271d29f58273d7f21287d7d8e52732
- Cited by
- 749
- References
- 98
- Citations by year
- 2026: 36 · 2025: 36 · 2024: 33 · 2023: 38 · 2022: 53 · 2021: 53 · 2020: 55 · 2019: 79 · 2018: 77 · 2017: 78 · 2016: 84 · 2015: 60 · 2014: 37 · 2013: 29 · 2012: 1
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Seoul National University Open Repository (Seoul National University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- flexible electronics, stretchable electronics, human-machine interaction, skin interface, health monitoring, disease surveillance, surgical applications, optoelectronics
- MeSH terms
- Biomedical Engineering, Brain, Electronics, Medical, Equipment and Supplies, Equipment Design, Humans, Myocardium, Prosthesis Design, Semiconductors, Skin, Prostheses and Implants, Nanostructures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.