Light-Sheet Microscopy in Neuroscience
Open accessThe DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Light-sheet microscopy is an imaging approach that offers unique advantages for a diverse range of neuroscience applications. Unlike point-scanning techniques such as confocal and two-photon microscopy, light-sheet microscopes illuminate an entire plane of tissue, while imaging this plane onto a camera. Although early implementations of light sheet were optimized for longitudinal imaging of embryonic development in small specimens, emerging implementations are capable of capturing light-sheet images in freely moving, unconstrained specimens and even the intact in vivo mammalian brain. Meanwhile, the unique photobleaching and signal-to-noise benefits afforded by light-sheet microscopy's parallelized detection deliver the ability to perform volumetric imaging at much higher speeds than can be achieved using point scanning. This review describes the basic principles and evolution of light-sheet microscopy, followed by perspectives on emerging applications and opportunities for both imaging large, cleared, and expanded neural tissues and high-speed, functional imaging in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 3×
“The most common method for in vivo optical sectioning is laser point scanning, as used in conventional confocal and two-photon microscopy (Denk et al. 1990, White et al. 1987).”
BackgroundMethodGreen fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802 · cited 1×
“In particular, genetically encoded fluorescent proteins can now be expressed in specific cell types, enabling detailed structural mapping and connectivity tracing (Chalfie et al. 1994).”
BackgroundUltrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundMillisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 1×
“…the optical manipulation of cellular activity, and the evolution of a wide range of model organisms, from worms and flies to mice and marmosets, we now have the potential to optically interrogate complete brain circuits and nervous systems in real time (Boyden et al. 2005, Packer et al. 2015).”
BackgroundSpatially resolved, highly multiplexed RNA profiling in single cells
Chen, K. H., Boettiger, A. N., Moffitt, J. R., Wang, S., & Zhuang, X. (2015) · Science · doi:10.1126/science.aaa6090 · Cited by 2,969 · cited 3×
“…circuits, and cell types have further increased the utility of this approach, providing a bridge between in vivo recordings of cellular function and behavior and the subcellular-level structures and connectivity of the brain (Chatterjee et al. 2018, K.H. Chen et al. 2015, Zolnik et al. 2017).”
BackgroundOptical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Lattice light-sheet microscopy: Imaging molecules to embryos at high spatiotemporal resolution
Chen, B.-C., Legant, W. R., Wang, K., Shao, L., Milkie, D. E., Davidson, M. W., Janetopoulos, C., Wu, X. S., Hammer, J. A., Liu, Z., et al. (2014) · Science · doi:10.1126/science.1257998 · Cited by 1,919 · cited 1×
“…et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach 2010, Planchon et al. 2011), Airy beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination…”
iDISCO: A Simple, Rapid Method to Immunolabel Large Tissue Samples for Volume Imaging
Renier, N., Wu, Z., Simon, D. J., Yang, J., Ariel, P., & Tessier-Lavigne, M. (2014) · Cell · doi:10.1016/j.cell.2014.10.010 · Cited by 1,818 · cited 1×
“…of rich biochemical information as well as fluorescent proteins, improved labeling during postprocessing, improved clearing performance, and decreased tissue processing time and complexity (Chung & Deisseroth 2013, Kim et al. 2015, Murakami et al. 2018, Renier et al. 2014, Yang et al. 2014).”
BackgroundReconstruction of Zebrafish Early Embryonic Development by Scanned Light Sheet Microscopy
Keller, P. J., Schmidt, A. D., Wittbrodt, J., & Stelzer, E. H. K. (2008) · Science · doi:10.1126/science.1162493 · Cited by 1,560 · cited 1×
“…included adding additional optical paths for illumination and the detection of fluorescence from different directions to reduce the need for sample rotation, although multiobjective approaches often made sample positioning even more challenging (Keller et al. 2008, 2010; Tomer et al. 2012).”
BackgroundIn vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505 · cited 1×
“…A uthor M anuscript The parallel development and maturation of multiphoton microscopy fueled this optical revolution, providing the ability to visualize the activity of single cells up to around 1 mm deep into the scattering mammalian brain (Denk et al. 1990, Horton et al. 2013, Kobat et al. 2009).”
BackgroundChen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501 · cited 3×
“…circuits, and cell types have further increased the utility of this approach, providing a bridge between in vivo recordings of cellular function and behavior and the subcellular-level structures and connectivity of the brain (Chatterjee et al. 2018, K.H. Chen et al. 2015, Zolnik et al. 2017).”
BackgroundWhole-brain functional imaging at cellular resolution using light-sheet microscopy
Ahrens, M. B., Orger, M. B., Robson, D. N., Li, J. M., & Keller, P. J. (2013) · Nature Methods · doi:10.1038/nmeth.2434 · Cited by 1,392 · cited 2×
“This detection refocusing can be achieved by physically moving the detection objective (e.g., using a piezo) (Ahrens et al. 2013), by using optical components such as an electrically tunable lens in the detection path to adjust the focal plane without moving the detection objective (Fahrbach et al.…”
BackgroundMethodInfluentialUltramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain
Dodt, H.-U., Leischner, U., Schierloh, A., Jährling, N., Mauch, C. P., Deininger, K., Deussing, J. M., Eder, M., Zieglgänsberger, W., & Becker, K. (2007) · Nature Methods · doi:10.1038/nmeth1036 · Cited by 1,238 · cited 1×
“Light-Sheet Imaging of Cleared and Expanded Tissues Early tissue clearing techniques dehydrated samples, replacing water with oils that matched the refractive index of lipid membranes to reduce scattering (Dodt et al. 2007).”
BackgroundOptimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundRapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination
Planchon, T. A., Gao, L., Milkie, D. E., Davidson, M. W., Galbraith, J. A., Galbraith, C. G., & Betzig, E. (2011) · Nature Methods · doi:10.1038/nmeth.1586 · Cited by 1,112 · cited 2×
“…et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach 2010, Planchon et al. 2011), Airy beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon…”
BackgroundMethodInfluentialUltrafast neuronal imaging of dopamine dynamics with designed genetically encoded sensors
Patriarchi, T., Cho, J. R., Merten, K., Howe, M. W., Marley, A., Xiong, W.-H., Folk, R. W., Broussard, G. J., Liang, R., Jang, M. J., et al. (2018) · Science · doi:10.1126/science.aat4422 · Cited by 1,074 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundSensitive red protein calcium indicators for imaging neural activity
Dana, H., Mohar, B., Sun, Y., Narayan, S., Gordus, A., Hasseman, J. P., Tsegaye, G., Holt, G. T., Hu, A., Walpita, D., et al. (2016) · eLife · doi:10.7554/elife.12727 · Cited by 1,034
Simultaneous Denoising, Deconvolution, and Demixing of Calcium Imaging Data
Pnevmatikakis, E. A., Soudry, D., Gao, Y., Machado, T. A., Merel, J., Pfau, D., Reardon, T., Mu, Y., Lacefield, C., Yang, W., et al. (2016) · Neuron · doi:10.1016/j.neuron.2015.11.037 · Cited by 1,029 · cited 1×
“Dimensionality reduction methods that turn a movie of flashing cells into an interpretable map of cell locations and their activity patterns are applicable to fast 3D light-sheet data (Pnevmatikakis et al. 2016).”
MethodSingle-Cell Phenotyping within Transparent Intact Tissue through Whole-Body Clearing
Yang, B., Treweek, J. B., Kulkarni, R. P., Deverman, B. E., Chen, C.-K., Lubeck, E., Shah, S., Cai, L., & Gradinaru, V. (2014) · Cell · doi:10.1016/j.cell.2014.07.017 · Cited by 925 · cited 1×
“…of rich biochemical information as well as fluorescent proteins, improved labeling during postprocessing, improved clearing performance, and decreased tissue processing time and complexity (Chung & Deisseroth 2013, Kim et al. 2015, Murakami et al. 2018, Renier et al. 2014, Yang et al. 2014).”
BackgroundWhite, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858 · cited 1×
“The most common method for in vivo optical sectioning is laser point scanning, as used in conventional confocal and two-photon microscopy (Denk et al. 1990, White et al. 1987).”
MethodCLARITY for mapping the nervous system
Chung, K., & Deisseroth, K. (2013) · Nature Methods · doi:10.1038/nmeth.2481 · Cited by 747 · cited 1×
“…of rich biochemical information as well as fluorescent proteins, improved labeling during postprocessing, improved clearing performance, and decreased tissue processing time and complexity (Chung & Deisseroth 2013, Kim et al. 2015, Murakami et al. 2018, Renier et al. 2014, Yang et al. 2014).”
BackgroundA large field of view two-photon mesoscope with subcellular resolution for in vivo imaging
Sofroniew, N. J., Flickinger, D., King, J., & Svoboda, K. (2016) · eLife · doi:10.7554/elife.14472 · Cited by 645
Deep tissue multiphoton microscopy using longer wavelength excitation
Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C. (2009) · Optics Express · doi:10.1364/oe.17.013354 · Cited by 574 · cited 1×
“…A uthor M anuscript The parallel development and maturation of multiphoton microscopy fueled this optical revolution, providing the ability to visualize the activity of single cells up to around 1 mm deep into the scattering mammalian brain (Denk et al. 1990, Horton et al. 2013, Kobat et al. 2009).”
BackgroundObserving the cell in its native state: Imaging subcellular dynamics in multicellular organisms
Liu, T.-L., Upadhyayula, S., Milkie, D. E., Singh, V., Wang, K., Swinburne, I. A., Mosaliganti, K. R., Collins, Z. M., Hiscock, T. W., Shea, J., et al. (2018) · Science · doi:10.1126/science.aaq1392 · Cited by 570 · cited 2×
“…of the light sheet to reduce striping (Huisken & Stainier 2007); beam shaping and adaptive optics (Dalgarno et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach 2010, Planchon et al. 2011), Airy beams…”
BackgroundBouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566 · cited 2×
“Bouchard et al. (2015) subsequently demonstrated swept confocally aligned planar excitation (SCAPE) microscopy, which combined a scanning galvanometer mirror with oblique plane illumination to enable the excitation sheet to be swept laterally across the sample, while maintaining the focus of the…”
BackgroundSelf-citationPacker, A. M., Russell, L. E., Dalgleish, H. W. P., & Häusser, M. (2015) · Nature Methods · doi:10.1038/nmeth.3217 · Cited by 565 · cited 2×
“…the optical manipulation of cellular activity, and the evolution of a wide range of model organisms, from worms and flies to mice and marmosets, we now have the potential to optically interrogate complete brain circuits and nervous systems in real time (Boyden et al. 2005, Packer et al. 2015).”
BackgroundTomer, R., Khairy, K., Amat, F., & Keller, P. J. (2012) · Nature Methods · doi:10.1038/nmeth.2062 · Cited by 545 · cited 1×
“…included adding additional optical paths for illumination and the detection of fluorescence from different directions to reduce the need for sample rotation, although multiobjective approaches often made sample positioning even more challenging (Keller et al. 2008, 2010; Tomer et al. 2012).”
BackgroundKeller, P. J., Schmidt, A. D., Santella, A., Khairy, K., Bao, Z., Wittbrodt, J., & Stelzer, E. H. K. (2010) · Nature Methods · doi:10.1038/nmeth.1476 · Cited by 528 · cited 2×
“…beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination (Keller et al. 2010, Mertz & Kim 2010), and nonlinear photoactivation (Cella Zanacchi et al. 2013).”
BackgroundHigh-speed in vivo calcium imaging reveals neuronal network activity with near-millisecond precision
Grewe, B. F., Langer, D., Kasper, H., Kampa, B. M., & Helmchen, F. (2010) · Nature Methods · doi:10.1038/nmeth.1453 · Cited by 522 · cited 1×
“Diverse innovations have increased imaging speeds and fields of view and have enabled combined imaging and photomanipulation in awake, behaving animals performing complex tasks (Grewe et al. 2010, Nadella et al. 2016, Packer et al. 2015, Sofroniew et al. 2016, Weisenburger & Vaziri 2018).”
BackgroundQuantitative assessment of fluorescent proteins
Cranfill, P. J., Sell, B. R., Baird, M. A., Allen, J. R., Lavagnino, Z., de Gruiter, H. M., Kremers, G.-J., Davidson, M. W., Ustione, A., & Piston, D. W. (2016) · Nature Methods · doi:10.1038/nmeth.3891 · Cited by 497 · cited 1×
“Recent results have suggested that for fluorescent proteins, photobleaching half-lives shorten with higher incident power (Cranfill et al. 2016).”
BackgroundDeep and fast live imaging with two-photon scanned light-sheet microscopy
Truong, T. V., Supatto, W., Koos, D. S., Choi, J. M., & Fraser, S. E. (2011) · Nature Methods · doi:10.1038/nmeth.1652 · Cited by 489 · cited 2×
“…beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination (Keller et al. 2010, Mertz & Kim 2010), and nonlinear photoactivation (Cella Zanacchi et al. 2013).”
BackgroundHigh-speed recording of neural spikes in awake mice and flies with a fluorescent voltage sensor
Gong, Y., Huang, C., Li, J. Z., Grewe, B. F., Zhang, Y., Eismann, S., & Schnitzer, M. J. (2015) · Science · doi:10.1126/science.aab0810 · Cited by 462 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundOptical recording of action potentials in mammalian neurons using a microbial rhodopsin
Kralj, J. M., Douglass, A. D., Hochbaum, D. R., Maclaurin, D., & Cohen, A. E. (2012) · Nature Methods · doi:10.1038/nmeth.1782 · Cited by 460 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundSpace–time wiring specificity supports direction selectivity in the retina
EyeWirers, T., Kim, J. S., Greene, M. J., Zlateski, A., Lee, K., Richardson, M., Turaga, S. C., Purcaro, M., Balkam, M., Robinson, A., et al. (2014) · Nature · doi:10.1038/nature13240 · Cited by 450 · cited 1×
“New algorithms to vectorize connectivity and extract features such as cell density, projection density, spine density, and interactions between cell types from these enormous data sets are needed, on par with analysis efforts developed for modern electron microscopy connectomics (Kim et al. 2014).”
MethodMultifocal multiphoton microscopy
Bewersdorf, J., Pick, R., & Hell, S. W. (1998) · Optics Letters · doi:10.1364/ol.23.000655 · Cited by 429 · cited 1×
“…require more complex hardware configurations to maintain optical sectioning but include multispot scanning confocal and two-photon microscopy (Bewersdorf et al. 1998, Gräf et al. 2005, Watson et al. 2009), line-scanning confocal microscopy (Castellano-Munoz et al. 2012, Rajadhyaksha et al.…”
Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM)
Huisken, J., & Stainier, D. Y. R. (2007) · Optics Letters · doi:10.1364/ol.32.002608 · Cited by 424 · cited 1×
“These improvements included varying the in-plane propagation direction of the light sheet to reduce striping (Huisken & Stainier 2007); beam shaping and adaptive optics (Dalgarno et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams…”
BackgroundCortical column and whole-brain imaging with molecular contrast and nanoscale resolution
Gao, R., Asano, S. M., Upadhyayula, S., Pisarev, I., Milkie, D. E., Liu, T.-L., Singh, V., Graves, A., Huynh, G. H., Zhao, Y., et al. (2019) · Science · doi:10.1126/science.aau8302 · Cited by 370
Optically sectioned imaging by oblique plane microscopy
Dunsby, C. (2008) · Optics Express · doi:10.1364/oe.16.020306 · Cited by 348
Rapid 3D light-sheet microscopy with a tunable lens
Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J. (2013) · Optics Express · doi:10.1364/oe.21.021010 · Cited by 347 · cited 1×
“…(e.g., using a piezo) (Ahrens et al. 2013), by using optical components such as an electrically tunable lens in the detection path to adjust the focal plane without moving the detection objective (Fahrbach et al. 2013), or by extending the detection objective’s depth of field (Tomer et al. 2015).”
MethodHolekamp, T. F., Turaga, D., & Holy, T. E. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.011 · Cited by 336
Brain-wide 3D imaging of neuronal activity in Caenorhabditis elegans with sculpted light
Schrödel, T., Prevedel, R., Aumayr, K., Zimmer, M., & Vaziri, A. (2013) · Nature Methods · doi:10.1038/nmeth.2637 · Cited by 333 · cited 1×
“…with longer integration times that permit the use of lower repetition rate and thus higher peak-power lasers, supports its feasibility within thermal damage and saturation limits (for further modeling and analysis of these effects, see Hillman et al. 2018, Schrodel et al. 2013, Truong et al. 2011).”
BackgroundSiedentopf, H., & Zsigmondy, R. (1902) · Annalen der Physik · doi:10.1002/andp.19023150102 · Cited by 321 · cited 1×
“Light-sheet microscopy is an approach that was first proposed over 100 years ago (Siedentopf & Zsigmondy 1902).”
Wu, Y., Ghitani, A., Christensen, R., Santella, A., Du, Z., Rondeau, G., Bao, Z., Colón-Ramos, D., & Shroff, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108494108 · Cited by 304 · cited 1×
“Other configurations were proposed to circumvent this constraint such as inverted SPIM, which mounted the orthogonal excitation and detection arms at 45° to horizontal, permitting imaging of intact samples from above or below (Wu et al. 2011).”
MethodVideo-rate confocal scanning laser microscope for imaging human tissues in vivo
Rajadhyaksha, M., Anderson, R. R., & Webb, R. H. (1999) · Applied Optics · doi:10.1364/ao.38.002105 · Cited by 300 · cited 1×
“…optical sectioning but include multispot scanning confocal and two-photon microscopy (Bewersdorf et al. 1998, Gräf et al. 2005, Watson et al. 2009), line-scanning confocal microscopy (Castellano-Munoz et al. 2012, Rajadhyaksha et al. 1999), and spinning-disk confocal microscopy (Gräf et al. 2005).”
MethodMurakami, T. C., Mano, T., Saikawa, S., Horiguchi, S. A., Shigeta, D., Baba, K., Sekiya, H., Shimizu, Y., Tanaka, K. F., Kiyonari, H., et al. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0109-1 · Cited by 292 · cited 1×
“…of rich biochemical information as well as fluorescent proteins, improved labeling during postprocessing, improved clearing performance, and decreased tissue processing time and complexity (Chung & Deisseroth 2013, Kim et al. 2015, Murakami et al. 2018, Renier et al. 2014, Yang et al. 2014).”
Background3‐D PSF fitting for fluorescence microscopy: implementation and localization application
KIRSHNER, H., AGUET, F., SAGE, D., & UNSER, M. (2013) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03675.x · Cited by 277
Adaptive light-sheet microscopy for long-term, high-resolution imaging in living organisms
Royer, L. A., Lemon, W. C., Chhetri, R. K., Wan, Y., Coleman, M., Myers, E. W., & Keller, P. J. (2016) · Nature Biotechnology · doi:10.1038/nbt.3708 · Cited by 274 · cited 1×
“…sheet to reduce striping (Huisken & Stainier 2007); beam shaping and adaptive optics (Dalgarno et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach 2010, Planchon et al. 2011), Airy beams (Vettenburg et al.…”
BackgroundBrain heating induced by near-infrared lasers during multiphoton microscopy
Podgorski, K., & Ranganathan, G. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00275.2016 · Cited by 269
Deconvolution-free Subcellular Imaging with Axially Swept Light Sheet Microscopy
Dean, K. M., Roudot, P., Welf, E. S., Danuser, G., & Fiolka, R. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.05.013 · Cited by 253 · cited 3×
“Others are implementing higher NA beam waist scanning, in some cases reading out only the rows of the camera corresponding to where the waist is narrow (Dean et al. 2015, Migliori et al. 2018), although this approach decreases the light efficiency of the system.”
BackgroundPepperkok, R., Squire, A., Geley, S., & Bastiaens, P. I. H. (1999) · Current Biology · doi:10.1016/s0960-9822(99)80117-1 · Cited by 249 · cited 1×
“To image a volume of 512 × 512 × 100 (Lx × Ly × Lz) voxels at 10 volumes per second (VPS), the integration time per voxel would reach tp = 4 ns, the fluorescence lifetime of green fluorescent protein (Pepperkok et al. 1999).”
BackgroundStochastic electrotransport selectively enhances the transport of highly electromobile molecules
Kim, S.-Y., Cho, J. H., Murray, E., Bakh, N., Choi, H., Ohn, K., Ruelas, L., Hubbert, A., McCue, M., Vassallo, S. L., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1510133112 · Cited by 246 · cited 1×
“…of rich biochemical information as well as fluorescent proteins, improved labeling during postprocessing, improved clearing performance, and decreased tissue processing time and complexity (Chung & Deisseroth 2013, Kim et al. 2015, Murakami et al. 2018, Renier et al. 2014, Yang et al. 2014).”
BackgroundKeller, P. J., & Ahrens, M. B. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.039 · Cited by 245 · cited 1×
“However, modern cameras, lasers, small model organisms such as worms, fish, and flies, and modern tissue-clearing techniques have unlocked the potential of this approach for diverse neuroscience applications (Keller & Ahrens 2015).”
BackgroundSPED Light Sheet Microscopy: Fast Mapping of Biological System Structure and Function
Tomer, R., Lovett-Barron, M., Kauvar, I., Andalman, A., Burns, V. M., Sankaran, S., Grosenick, L., Broxton, M., Yang, S., & Deisseroth, K. (2015) · Cell · doi:10.1016/j.cell.2015.11.061 · Cited by 239 · cited 1×
“…(e.g., using a piezo) (Ahrens et al. 2013), by using optical components such as an electrically tunable lens in the detection path to adjust the focal plane without moving the detection objective (Fahrbach et al. 2013), or by extending the detection objective’s depth of field (Tomer et al. 2015).”
MethodWhole-animal functional and developmental imaging with isotropic spatial resolution
Chhetri, R. K., Amat, F., Wan, Y., Höckendorf, B., Lemon, W. C., & Keller, P. J. (2015) · Nature Methods · doi:10.1038/nmeth.3632 · Cited by 235 · cited 1×
“Additional methods have incorporated deconvolution and computational reconstruction of multiple projections to yield higher isotropic resolution (Chhetri et al. 2015, Wu et al. 2016), although the routine deconvolution of large, high-speed data sets remains very computationally demanding.”
Method3D single-molecule super-resolution microscopy with a tilted light sheet
Gustavsson, A.-K., Petrov, P. N., Lee, M. Y., Shechtman, Y., & Moerner, W. E. (2018) · Nature Communications · doi:10.1038/s41467-017-02563-4 · Cited by 193 · cited 1×
“Multiple studies have also demonstrated light-sheet approaches for subcellular imaging (Gustavsson et al. 2018, Liu et al. 2018).”
BackgroundImproved calcium imaging in transgenic mice expressing a troponin C–based biosensor
Heim, N., Garaschuk, O., Friedrich, M. W., Mank, M., Milos, R. I., Kovalchuk, Y., Konnerth, A., & Griesbeck, O. (2007) · Nature Methods · doi:10.1038/nmeth1009 · Cited by 185 · cited 1×
“…to change fluorescence in response to calcium and a host of other cellular signaling molecules, enabling unprecedented optical readouts of cellular function (Akerboom et al. 2012, Chen et al. 2013, Dana et al. 2016, Gong et al. 2015, Heim et al. 2007, Kralj et al. 2012, Patriarchi et al. 2018).”
BackgroundScanning light-sheet microscopy in the whole mouse brain with HiLo background rejection
Mertz, J., & Kim, J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3324890 · Cited by 183 · cited 1×
“…beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination (Keller et al. 2010, Mertz & Kim 2010), and nonlinear photoactivation (Cella Zanacchi et al. 2013).”
BackgroundNontoxic, double-deletion-mutant rabies viral vectors for retrograde targeting of projection neurons
Chatterjee, S., Sullivan, H. A., MacLennan, B. J., Xu, R., Hou, Y., Lavin, T. K., Lea, N. E., Michalski, J. E., Babcock, K. R., Dietrich, S., et al. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0091-7 · Cited by 174 · cited 1×
“…circuits, and cell types have further increased the utility of this approach, providing a bridge between in vivo recordings of cellular function and behavior and the subcellular-level structures and connectivity of the brain (Chatterjee et al. 2018, K.H. Chen et al. 2015, Zolnik et al. 2017).”
BackgroundLive Cell Spinning Disk Microscopy
Gräf, R., Rietdorf, J., & Zimmermann, T. (2005) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/b102210 · Cited by 164
Stelzer, E. H. K., & Lindek, S. (1994) · Optics Communications · doi:10.1016/0030-4018(94)90533-9 · Cited by 163 · cited 2×
“…benefits over point scanning in terms of simplicity, light efficiency, low phototoxicity, and the potential for high volumetric imaging speeds, while the resolution benefits of its theta geometry extend its utility to imaging scattering tissues (Engelbrecht & Stelzer 2006, Stelzer & Lindek 1994).”
BackgroundMethodRandom-access scanning microscopy for 3D imaging in awake behaving animals
Nadella, K. M. N. S., Roš, H., Baragli, C., Griffiths, V. A., Konstantinou, G., Koimtzis, T., Evans, G. J., Kirkby, P. A., & Silver, R. A. (2016) · Nature Methods · doi:10.1038/nmeth.4033 · Cited by 151 · cited 1×
“Diverse innovations have increased imaging speeds and fields of view and have enabled combined imaging and photomanipulation in awake, behaving animals performing complex tasks (Grewe et al. 2010, Nadella et al. 2016, Packer et al. 2015, Sofroniew et al. 2016, Weisenburger & Vaziri 2018).”
BackgroundA line scanned light-sheet microscope with phase shaped self-reconstructing beams
Fahrbach, F. O., & Rohrbach, A. (2010) · Optics Express · doi:10.1364/oe.18.024229 · Cited by 143 · cited 1×
“…adaptive optics (Dalgarno et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach 2010, Planchon et al. 2011), Airy beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et…”
BackgroundVaadia, R. D., Li, W., Voleti, V., Singhania, A., Hillman, E. M. C., & Grueber, W. B. (2019) · Current Biology · doi:10.1016/j.cub.2019.01.060 · Cited by 137
Self-citationTemperature Rise under Two-Photon Optogenetic Brain Stimulation
Picot, A., Domínguez, S., Liu, C., Chen, I.-W., Tanese, D., Ronzitti, E., Berto, P., Papagiakoumou, E. I., Oron, D., Tessier, G., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.06.119 · Cited by 124 · cited 1×
“…pulsed laser sources as well as thermal effects in living tissues: Average powers exceeding 200 mW at the sample have been shown to cause brain heating, while pulse energies of 2 nJ are considered to be the upper limit for fluorophore saturation (Picot et al. 2018, Podgorski & Ranganathan 2016).”
BackgroundWeisenburger, S., & Vaziri, A. (2018) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-072116-031458 · Cited by 116 · cited 1×
“Diverse innovations have increased imaging speeds and fields of view and have enabled combined imaging and photomanipulation in awake, behaving animals performing complex tasks (Grewe et al. 2010, Nadella et al. 2016, Packer et al. 2015, Sofroniew et al. 2016, Weisenburger & Vaziri 2018).”
BackgroundLight sheet theta microscopy for rapid high-resolution imaging of large biological samples
Migliori, B., Datta, M. S., Dupré, C., Apak, M. C., Asano, S. M., Gao, R., Boyden, E. S., Hermanson, O., Yuste, R., & Tomer, R. (2018) · BMC Biology · doi:10.1186/s12915-018-0521-8 · Cited by 107 · cited 1×
“Others are implementing higher NA beam waist scanning, in some cases reading out only the rows of the camera corresponding to where the waist is narrow (Dean et al. 2015, Migliori et al. 2018), although this approach decreases the light efficiency of the system.”
BackgroundLight-Sheet Confined Super-Resolution Using Two-Photon Photoactivation
Zanacchi, F. C., Lavagnino, Z., Faretta, M., Furia, L., & Diaspro, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067667 · Cited by 65 · cited 1×
“…beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination (Keller et al. 2010, Mertz & Kim 2010), and nonlinear photoactivation (Cella Zanacchi et al. 2013).”
BackgroundWu, Y., Chandris, P., Winter, P. W., Kim, E. Y., Jaumouillé, V., Kumar, A., Guo, M. Y., Leung, J. M., Smith, C. D., Rey‐Suarez, I., et al. (2016) · Optica · doi:10.1364/optica.3.000897 · Cited by 57 · cited 1×
“Additional methods have incorporated deconvolution and computational reconstruction of multiple projections to yield higher isotropic resolution (Chhetri et al. 2015, Wu et al. 2016), although the routine deconvolution of large, high-speed data sets remains very computationally demanding.”
MethodOptically sectioned imaging by oblique plane microscopy
Kumar, S., Lin, Z., Lyon, A. R., MacLeod, K. T., & Dunsby, C. W. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.873471 · Cited by 56
Miniaturized selective plane illumination microscopy for high-contrast in vivo fluorescence imaging
Engelbrecht, C. J., Voigt, F. F., & Helmchen, F. (2010) · Optics Letters · doi:10.1364/ol.35.001413 · Cited by 56 · cited 1×
“In a related approach, Engelbrecht et al. (2010) created a miniaturized SPIM geometry using gradient-index lenses and a prism mirror, which could be inserted into the living brain for optically sectioned imaging.”
MethodHillman, E. M. C., Voleti, V., Patel, K., Li, W., Yu, H., Campos, C. P., Benezra, S. E., Bruno, R. M., & Galwaduge, P. T. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.03.007 · Cited by 54 · cited 7×
“This effect may in part explain the lower degree of photobleaching that is observed with spinning-disk confocal compared to single-point scanning (Hillman et al. 2018).”
BackgroundInfluentialSelf-citationZolnik, T. A., Sha, F., Johenning, F. W., Schreiter, E. R., Looger, L. L., Larkum, M. E., & Sachdev, R. N. S. (2016) · The Journal of Physiology · doi:10.1113/jp273116 · Cited by 45 · cited 1×
“…circuits, and cell types have further increased the utility of this approach, providing a bridge between in vivo recordings of cellular function and behavior and the subcellular-level structures and connectivity of the brain (Chatterjee et al. 2018, K.H. Chen et al. 2015, Zolnik et al. 2017).”
BackgroundChoi, H., Tzeranis, D. S., Cha, J. W., Clémenceau, P., de Jong, S. J. G., van Geest, L. K., Moon, J. H., Yannas, I. V., & So, P. T. C. (2012) · Optics Express · doi:10.1364/oe.20.026219 · Cited by 45 · cited 1×
“A uthor M anuscript A uthor M anuscript A uthor M anuscript A uthor M anuscript In terms of illumination power, one might expect that Lx × Ly more power is needed to illuminate a plane of area A = Lx × Ly (Choi et al. 2012).”
BackgroundLavagnino, Z., Zanacchi, F. C., Ronzitti, E., & Diaspro, A. (2013) · Optics Express · doi:10.1364/oe.21.005998 · Cited by 44 · cited 1×
“…et al. 2011), Airy beams (Vettenburg et al. 2014), lattice sheets (Chen et al. 2014), beam-waist scanning (Dean et al. 2015), two-photon excitation (Lavagnino et al. 2013, Truong et al. 2011), structured illumination (Keller et al. 2010, Mertz & Kim 2010), and nonlinear photoactivation (Cella…”
BackgroundTwo-photon imaging with diffractive optical elements
Yuste, R. (2009) · Frontiers in Neural Circuits · doi:10.3389/neuro.04.006.2009 · Cited by 43 · cited 1×
“…to maintain optical sectioning but include multispot scanning confocal and two-photon microscopy (Bewersdorf et al. 1998, Gräf et al. 2005, Watson et al. 2009), line-scanning confocal microscopy (Castellano-Munoz et al. 2012, Rajadhyaksha et al. 1999), and spinning-disk confocal…”
Wavefront corrected light sheet microscopy in turbid media
Dalgarno, H. I. C., Čižmár, T., Vettenburg, T., Nylk, J., Gunn‐Moore, F. J., & Dholakia, K. (2012) · Applied Physics Letters · doi:10.1063/1.4710527 · Cited by 35 · cited 1×
“…varying the in-plane propagation direction of the light sheet to reduce striping (Huisken & Stainier 2007); beam shaping and adaptive optics (Dalgarno et al. 2012, Lindek et al. 1996, Liu et al. 2018, Royer et al. 2016, Wilding et al. 2016); and the use of Bessel beams (Fahrbach & Rohrbach…”
Background
Cited by
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0
Voleti, V., Patel, K. B., Li, W., Perez Campos, C., Bharadwaj, S., Yu, H., Ford, C., Casper, M. J., Yan, R. W., Liang, W., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0579-4 · Cited by 320
Self-citationSingle-Virus Tracking: From Imaging Methodologies to Virological Applications
Liu, S.-L., Wang, Z.-G., Xie, H.-Y., Liu, A.-A., Lamb, D. C., & Pang, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00692 · Cited by 224
Pushing the frontiers: tools for monitoring neurotransmitters and neuromodulators
Wu, Z., Lin, D., & Li, Y. (2022) · Nature Reviews Neuroscience · doi:10.1038/s41583-022-00577-6 · Cited by 222
Widespread receptor-driven modulation in peripheral olfactory coding
Xu, L., Li, W., Voleti, V., Zou, D.-J., Hillman, E. M. C., & Firestein, S. (2020) · Science · doi:10.1126/science.aaz5390 · Cited by 166
Self-citation
Metadata
- Authors
- Hillman, E. M. C., Voleti, V., Li, W., & Yu, H.
- Venue
- Annual Review of Neuroscience
- Publisher
- Annual Reviews
- Published
- 2019-07-08
- Volume
- 42
- Issue
- 1
- Pages
- 295-313
- ISSN
- 0147-006X (ISSN-L)
- 1545-4126
- OpenAlex
- W2960054497
- Cited by
- 188
- References
- 76
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.