OpenMEEG: opensource software for quasistatic bioelectromagnetics
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Interpreting and controlling bioelectromagnetic phenomena require realistic physiological models and accurate numerical solvers. A semi-realistic model often used in practise is the piecewise constant conductivity model, for which only the interfaces have to be meshed. This simplified model makes it possible to use Boundary Element Methods. Unfortunately, most Boundary Element solutions are confronted with accuracy issues when the conductivity ratio between neighboring tissues is high, as for instance the scalp/skull conductivity ratio in electro-encephalography. To overcome this difficulty, we proposed a new method called the symmetric BEM, which is implemented in the OpenMEEG software. The aim of this paper is to present OpenMEEG, both from the theoretical and the practical point of view, and to compare its performances with other competing software packages. METHODS: We have run a benchmark study in the field of electro- and magneto-encephalography, in order to compare the accuracy of OpenMEEG with other freely distributed forward solvers. We considered spherical models, for which analytical solutions exist, and we designed randomized meshes to assess the variability of the accuracy. Two measures were used to characterize the accuracy. the Relative Difference Measure and the Magnitude ratio. The comparisons were run, either with a constant number of mesh nodes, or a constant number of unknowns across methods. Computing times were also compared. RESULTS: We observed more pronounced differences in accuracy in electroencephalography than in magnetoencephalography. The methods could be classified in three categories: the linear collocation methods, that run very fast but with low accuracy, the linear collocation methods with isolated skull approach for which the accuracy is improved, and OpenMEEG that clearly outperforms the others. As far as speed is concerned, OpenMEEG is on par with the other methods for a constant number of unknowns, and is hence faster for a prescribed accuracy level. CONCLUSIONS: This study clearly shows that OpenMEEG represents the state of the art for forward computations. Moreover, our software development strategies have made it handy to use and to integrate with other packages. The bioelectromagnetic research community should therefore be able to benefit from OpenMEEG with a limited development effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“Magnetoencephalography (MEG) is concerned with magnetic fields produced by sources within the brain, which, like for EEG, are modeled as dipoles [13].”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
IEEE Transactions on Biomedical Engineering
(2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.10 · Cited by 1,400
Nolte, G. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/22/002 · Cited by 1,022
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 1×
“The Dipoli solver implements a linear collocation method with Isolated Skull Approach (ISA) [24], whereas BEMCP implements a simple linear collocation method.”
A common formalism for the Integral formulations of the forward EEG problem
Kybic, J., Clerc, M., Abboud, T., Faugeras, O., Keriven, R., & Papadopoulo, T. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.837363 · Cited by 422
Self-citationOn Bioelectric Potentials in an Inhomogeneous Volume Conductor
Geselowitz, D. B. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86571-8 · Cited by 332
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
Source parameter estimation in inhomogeneous volume conductors of arbitrary shape
Oostendorp, T. F., & van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.19859 · Cited by 226
de Munck, J. C. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256433 · Cited by 193
Cited by
MEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784
Self-citationBrainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Self-citationReal-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
The Virtual Brain: a simulator of primate brain network dynamics
Sanz Leon, P., Knock, S. A., Woodman, M. M., Domide, L., Mersmann, J., McIntosh, A. R., & Jirsa, V. (2013) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2013.00010 · Cited by 523
The Virtual Epileptic Patient: Individualized whole-brain models of epilepsy spread
Jirsa, V. K., Proix, T., Perdikis, D., Woodman, M. M., Wang, H., Gonzalez-Martinez, J., Bernard, C., Bénar, C., Guye, M., Chauvel, P., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.049 · Cited by 430
Spatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view
Burle, B., Spieser, L., Roger, C., Casini, L., Hasbroucq, T., & Vidal, F. (2015) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.05.004 · Cited by 414
“The head model used here was based on a segmentation of the MNI152 template brain and the lead fi eld and forward solution were computed with the OpenMEEG software (Gramfort et al., 2010; Kybic et al., 2005), which is based on a symmetric Boundary Element Method.”
A fast pathway for fear in human amygdala
Méndez-Bértolo, C., Moratti, S., Toledano, R., Lopez-Sosa, F., Martínez-Alvarez, R., Mah, Y. H., Vuilleumier, P., Gil-Nagel, A., & Strange, B. A. (2016) · Nature Neuroscience · doi:10.1038/nn.4324 · Cited by 392
Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG
Mullen, T., Kothe, C., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Cauwenberghs, G., & Jung, T.-P. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609968 · Cited by 390
Rogasch, N. C., Thomson, R. H., Farzan, F., Fitzgibbon, B. M., Bailey, N. W., Hernandez-Pavon, J. C., Daskalakis, Z. J., & Fitzgerald, P. B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.037 · Cited by 309
An electroencephalographic signature predicts antidepressant response in major depression
Wu, W., Zhang, Y., Jiang, J., Lucas, M. V., Fonzo, G. A., Rolle, C. E., Cooper, C., Chin-Fatt, C., Krepel, N., Cornelssen, C. A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0397-3 · Cited by 302
Expectation and Attention in Hierarchical Auditory Prediction
Chennu, S., Noreika, V., Gueorguiev, D., Blenkmann, A., Kochen, S., Ibanez, A., Owen, A. M., & Bekinschtein, T. A. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.0114-13.2013 · Cited by 299
“The forward model was calculated using the OpenMEEG Boundary Element Method (Gramfort et al., 2010) on the cortical surface of a template MNI brain (colin27) with a 1 mm resolution.”
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Contrastive Learning of Subject-Invariant EEG Representations for Cross-Subject Emotion Recognition
Shen, X., Liu, X., Hu, X., Zhang, D., & Song, S. (2023) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2022.3164516 · Cited by 296
The effect of epoch length on estimated EEG functional connectivity and brain network organisation
Fraschini, M., Demuru, M., Crobe, A., Marrosu, F., Stam, C. J., & Hillebrand, A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036015 · Cited by 268
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Zhang, Y., Wu, W., Toll, R. T., Naparstek, S., Maron-Katz, A., Watts, M., Gordon, J., Jeong, J., Astolfi, L., Shpigel, E., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00614-8 · Cited by 241
Time-frequency mixed-norm estimates: Sparse M/EEG imaging with non-stationary source activations
Gramfort, A., Strohmeier, D., Haueisen, J., Hämäläinen, M. S., & Kowalski, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.051 · Cited by 234
“The computation of the gain matrix G , e.g., with a Boundary Element Method (BEM) [24, 16], requires modeling of the electromagnetic properties of the head [19] such as the specification of the tissue conductivities.”
Self-citationMixed-norm estimates for the M/EEG inverse problem using accelerated gradient methods
Gramfort, A., Kowalski, M., & Hämäläinen, M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/1937 · Cited by 223
“Computing the gain matrix accurately is particularly crucial for EEG, and involves complex numerical solvers (Kybic et al. 2005, Gramfort et al. 2010).”
Self-citationHassan, M., & Wendling, F. (2018) · IEEE Signal Processing Magazine · doi:10.1109/msp.2017.2777518 · Cited by 202
“When this information is combined with an accurate, possibly subject- or patient-specific representation of the volume conductor (the realistic head model [10] obtained by MRI segmentation), these methods considerably increase both the precision of localized sources and the estimation of associated time series, which…”
Bifurcation in brain dynamics reveals a signature of conscious processing independent of report
Sergent, C., Corazzol, M., Labouret, G., Stockart, F., Wexler, M., King, J.-R., Meyniel, F., & Pressnitzer, D. (2021) · Nature Communications · doi:10.1038/s41467-021-21393-z · Cited by 200
Differences in unity: The go/no-go and stop signal tasks rely on different mechanisms
Raud, L., Westerhausen, R., Dooley, N., & Huster, R. J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116582 · Cited by 199
Seeber, M., Scherer, R., Wagner, J., Solis-Escalante, T., & Müller-Putz, G. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.045 · Cited by 186
“Forward models were computed using OpenMEEG (Kybic et al., 2005; Gramfort et al., 2010) as boundary element models (BEM) consisting of four layers (brain, inner skull, outer skull, head surface) which were reconstructed from individual structural T1 MRI scans.”
The FieldTrip-SimBio pipeline for EEG forward solutions
Vorwerk, J., Oostenveld, R., Piastra, M. C., Magyari, L., & Wolters, C. H. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0463-y · Cited by 172
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
Transient modulations of neural responses to heartbeats covary with bodily self-consciousness
Park, H.-D., Bernasconi, F., Bello-Ruiz, J., Pfeiffer, C., Salomon, R., & Blanke, O. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.0311-16.2016 · Cited by 169
“The forward model was computed using the Open-MEEG Boundary Element Method (Gramfort et al., 2010) on the cortical surface of Colin27 MNI template.”
Dynamic reorganization of brain functional networks during cognition
Bola, M., & Sabel, B. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.057 · Cited by 160
Characterizing and minimizing the contribution of sensory inputs to TMS-evoked potentials
Biabani, M., Fornito, A., Mutanen, T. P., Morrow, J., & Rogasch, N. C. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.07.009 · Cited by 158
Canales-Johnson, A., Silva, C., Huepe, D., Rivera-Rei, Á., Noreika, V., Garcia, M. D. C., Silva, W., Ciraolo, C., Vaucheret, E., Sedeño, L., et al. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv076 · Cited by 146
“The forward model was calculated using the OpenMEEG Boundary Element Method (Gramfort et al. 2010) on the cortical surface of a templateMNI brain (colin27) with 1 mm reso-”
Can EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Hill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
“The forward model was solved using the openMEEG symmetric boundary element method (Gramfort et al., 2010; Kybic et al., 2005).”
Using fMRI connectivity to define a treatment-resistant form of post-traumatic stress disorder
Etkin, A., Maron-Katz, A., Wu, W., Fonzo, G. A., Huemer, J., Vértes, P. E., Patenaude, B., Richiardi, J., Goodkind, M. S., Keller, C. J., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aal3236 · Cited by 103
Predictive coding in autism spectrum disorder and attention deficit hyperactivity disorder
Gonzalez-Gadea, M. L., Chennu, S., Bekinschtein, T. A., Rattazzi, A., Beraudi, A., Tripicchio, P., Moyano, B., Soffita, Y., Steinberg, L., Adolfi, F., et al. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00543.2015 · Cited by 100
Closed-loop digital meditation improves sustained attention in young adults
Ziegler, D. A., Simon, A. J., Gallen, C. L., Skinner, S., Janowich, J. R., Volponi, J. J., Rolle, C. E., Mishra, J., Kornfield, J., Anguera, J. A., et al. (2019) · Nature Human Behaviour · doi:10.1038/s41562-019-0611-9 · Cited by 97
Heartbeat and somatosensory perception
Al, E., Iliopoulos, F., Nikulin, V. V., & Villringer, A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118247 · Cited by 86
Preterm Birth Changes Networks of Newborn Cortical Activity
Tokariev, A., Stjerna, S., Lano, A., Metsäranta, M., Palva, J. M., & Vanhatalo, S. (2019) · Cerebral Cortex · doi:10.1093/cercor/bhy012 · Cited by 53
Baird, B., Castelnovo, A., Riedner, B. A., Lutz, A., Ferrarelli, F., Boly, M., Davidson, R. J., & Tononi, G. (2018) · eneuro · doi:10.1523/eneuro.0293-18.2018 · Cited by 45
Identifying good practices for detecting inter-regional linear functional connectivity from EEG
Pellegrini, F., Delorme, A., Nikulin, V., & Haufe, S. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120218 · Cited by 43
Zhang, L., Gan, J. Q., & Wang, H. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00430 · Cited by 38
Shenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
Metadata
- Authors
- Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M.
- Venue
- BioMedical Engineering OnLine
- Published
- 2010
- Volume
- 9
- Issue
- 1
- Pages
- 45
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2145309136
- Cited by
- 1,154
- References
- 18
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.