The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Open accessAbstract
Perfusion is a fundamental biological function that refers to the delivery of oxygen and nutrients to tissue by means of blood flow. Perfusion MRI is sensitive to microvasculature and has been applied in a wide variety of clinical applications, including the classification of tumors, identification of stroke regions, and characterization of other diseases. Perfusion MRI techniques are classified with or without using an exogenous contrast agent. Bolus methods, with injections of a contrast agent, provide better sensitivity with higher spatial resolution, and are therefore more widely used in clinical applications. However, arterial spin-labeling methods provide a unique opportunity to measure cerebral blood flow without requiring an exogenous contrast agent and have better accuracy for quantification. Importantly, MRI-based perfusion measurements are minimally invasive overall, and do not use any radiation and radioisotopes. In this review, we describe the principles and techniques of perfusion MRI. This review summarizes comprehensive updated knowledge on the physical principles and techniques of perfusion MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Saver, J. L. (2006) · Stroke · doi:10.1161/01.str.0000196957.55928.ab · Cited by 2,181
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Kidwell, C. S., Saver, J. L., Mattiello, J., Starkman, S., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Vespa, P., Kalafut, M., et al. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200004)47:4<462::aid-ana9>3.0.co;2-y · Cited by 692
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Self-citationWu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Johnson, N. A., Jahng, G.-H., Weiner, M. W., Miller, B. L., Chui, H. C., Jagust, W. J., Gorno-Tempini, M. L., & Schuff, N. (2005) · Radiology · doi:10.1148/radiol.2343040197 · Cited by 587
Self-citationWong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Indicator Transit Time Considered as a Gamma Variate
THOMPSON, H. K., STARMER, C. F., WHALEN, R. E., & MCINTOSH, H. D. (1964) · Circulation Research · doi:10.1161/01.res.14.6.502 · Cited by 583
Law, M., Yang, S., Babb, J. S., Knopp, E. A., Golfinos, J. G., Zagzag, D., & Johnson, G. (2004) · PubMed Central · Cited by 508
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Self-citationCalamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Self-citationFunctional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Multisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1985) · Physical Review A · doi:10.1103/physreva.31.2753 · Cited by 400
Pintaske, J., Martirosian, P., Graf, H., Erb, G., Lodemann, K.-P., Claussen, C. D., & Schick, F. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197668.44926.f7 · Cited by 383
Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements
Günther, M., Oshio, K., & Feinberg, D. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20580 · Cited by 293
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI
Du, A. T., Jahng, G. H., Hayasaka, S., Kramer, J. H., Rosen, H. J., Gorno-Tempini, M. L., Rankin, K. P., Miller, B. L., Weiner, M. W., & Schuff, N. (2006) · Neurology · doi:10.1212/01.wnl.0000238163.71349.78 · Cited by 288
Self-citationCalamante, F., Gadian, D. G., & Connelly, A. (2002) · Stroke · doi:10.1161/01.str.0000014208.05597.33 · Cited by 283
Self-citationProjection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Velocity‐selective arterial spin labeling
Wong, E. C., Cronin, M. V., Wu, W., Inglis, B. A., Frank, L. R., & Liu, T. T. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20906 · Cited by 268
Efficiency of inversion pulses for background suppressed arterial spin labeling
Garcia, D. M., Duhamel, G., & Alsop, D. C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20556 · Cited by 260
Brix, G., Kiessling, F., Lucht, R., Darai, S., Wasser, K., Delorme, S., & Griebel, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20161 · Cited by 252
Regression algorithm correcting for partial volume effects in arterial spin labeling MRI
Asllani, I., Borogovac, A., & Brown, T. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21670 · Cited by 241
Gd-DTPA relaxivity depends on macromolecular content
Stanisz, G. J., & Henkelman, R. M. (2000) · Magnetic Resonance in Medicine · Cited by 235
Assessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Larsson, H. B. W., Courivaud, F., Rostrup, E., & Hansen, A. E. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22136 · Cited by 224
Vessel‐encoded arterial spin‐labeling using pseudocontinuous tagging
Wong, E. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21293 · Cited by 221
Arterial input function in perfusion MRI: A comprehensive review
Calamante, F. (2013) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.04.002 · Cited by 219
Self-citationProvenzale, J. M., Wang, G. R., Brenner, T., Petrella, J. R., & Sorensen, A. G. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.3.1780711 · Cited by 216
Dynamic Magnetic Resonance Perfusion Imaging of Brain Tumors
Covarrubias, D. J., Rosen, B. R., & Lev, M. H. (2004) · The Oncologist · doi:10.1634/theoncologist.9-5-528 · Cited by 213
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
Ordidge, R. J., Wylezinska, M., Hugg, J. W., Butterworth, E., & Franconi, F. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360410 · Cited by 199
Analysis of myocardial perfusion MRI
Jerosch‐Herold, M., Seethamraju, R. T., Swingen, C. M., Wilke, N. M., & Stillman, A. E. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20065 · Cited by 198
The Physiological Significance of the Time-to-Maximum (Tmax) Parameter in Perfusion MRI
Calamante, F., Christensen, S., Desmond, P. M., Østergaard, L., Davis, S. M., & Connelly, A. (2010) · Stroke · doi:10.1161/strokeaha.110.580670 · Cited by 192
Self-citationBrix, G., Bahner, M. L., Hoffmann, U., Horváth, A., & Schreiber, W. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja46269 · Cited by 186
On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1307 · Cited by 182
Partial volume correction of multiple inversion time arterial spin labeling MRI data
Chappell, M. A., Groves, A. R., MacIntosh, B. J., Donahue, M. J., Jezzard, P., & Woolrich, M. W. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22641 · Cited by 179
Wirestam, R., Knutsson, L., Østergaard, L., Bolling, M., Aunola, J.-P., Lindgren, A. G., Geijer, B., Holt�s, S., & St�hlberg, F. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200005)43:5<691::aid-mrm11>3.0.co;2-b · Cited by 165
Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
Calamante, F., Gadian, D. G., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10643 · Cited by 147
Self-citationBayesian estimation of cerebral perfusion using a physiological model of microvasculature
Mouridsen, K., Friston, K. J., Hjort, N., Gyldensted, L., Østergaard, L., & Kiebel, S. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.06.015 · Cited by 142
Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
Zaharchuk, G., Ledden, P. J., Kwong, K. K., Reese, T. G., Rosen, B. R., & Wald, L. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4>3.0.co;2-0 · Cited by 141
A Fully Automated Method for Quantitative Cerebral Hemodynamic Analysis Using DSC–MRI
Bjørnerud, A., & Emblem, K. E. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.4 · Cited by 136
Willats, L., & Calamante, F. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2833 · Cited by 130
Self-citationBjørnerud, A., Sorensen, A. G., Mouridsen, K., & Emblem, K. E. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.52 · Cited by 118
Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T
Fernández‐Seara, M. A., Wang, Z., Wang, J., Rao, H., Guenther, M., Feinberg, D. A., & Detre, J. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20674 · Cited by 114
Computer computations of cardiac output using the gamma function.
Starmer, C. F., & Clark, D. O. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.28.2.219 · Cited by 111
Whole‐brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
Talagala, S. L., Ye, F. Q., Ledden, P. J., & Chesnick, S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20124 · Cited by 110
Shin, W., Horowitz, S., Ragin, A. B., Chen, Y. J., Walker, M. T., & Carroll, T. J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21420 · Cited by 108
Quantitative imaging biomarkers in neuro-oncology
Waldman, A. D., Jackson, A., Price, S. J., Clark, C. A., Booth, T. C., Auer, D. P., Tofts, P. S., Collins, D. J., Leach, M. O., & Rees, J. H. (2009) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.92 · Cited by 108
An introduction to ASL labeling techniques
Wong, E. C. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24565 · Cited by 104
Silva, A. C., Williams, D. S., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380211 · Cited by 103
Kim, S. M., Kim, M. J., Rhee, H. Y., Ryu, C., Kim, E. J., Petersen, E. T., & Jahng, G. (2012) · Neuroradiology · doi:10.1007/s00234-012-1077-x · Cited by 98
Self-citationMultiple inversion recovery reduces static tissue signal in angiograms
Dixon, W. T., Sardashti, M., Castillo, M., & Stomp, G. P. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180202 · Cited by 97
Speck, O., Chang, L., DeSilva, N. M., & Ernst, T. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<381::aid-jmri2>3.0.co;2-y · Cited by 95
Singh, A. K., Haris, M., Rathore, D., Purwar, A., Sarma, M. K., Bayu, G., Husain, N., Rathore, R. K. S., & Gupta, R. K. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21080 · Cited by 95
Song, Y. S., Choi, S. H., Park, C., Yi, K. S., Lee, W. J., Yun, T. J., Kim, T. M., Lee, S., Kim, J., Sohn, C., et al. (2013) · Korean Journal of Radiology · doi:10.3348/kjr.2013.14.4.662 · Cited by 92
Self-citationSimonsen, C. Z., ��stergaard, L., Vestergaard‐Poulsen, P., Røhl, L., Bj�rnerud, A., & Gyldensted, C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199902)9:2<342::aid-jmri29>3.0.co;2-b · Cited by 86
Larsson, H., Hansen, A. E., Berg, H., Rostrup, E., & Haraldseth, O. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21328 · Cited by 84
Francis, S., Bowtell, R. W., & Gowland, P. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21442 · Cited by 80
Quantification of renal perfusion and function on a voxel‐by‐voxel basis: A feasibility study
Dujardin, M., Sourbron, S. P., Luypaert, R., Verbeelen, D. L., & Stadnik, T. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20608 · Cited by 79
Robson, P. M., Dai, W., Shankaranarayanan, A., Rofsky, N. M., & Alsop, D. C. (2010) · Radiology · doi:10.1148/radiol.092333 · Cited by 77
Hartkamp, N. S., Petersen, E. T., Vis, J. B. D., Bokkers, R. P. H., & Hendrikse, J. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2836 · Cited by 62
Kershaw, L. E., Hutchinson, C. E., & Buckley, D. L. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21674 · Cited by 56
Haller, S., Rodriguez, C. K., Moser, D. A., Toma, S., Hofmeister, J., Sinanaj, I., Ville, D. V. D., Giannakopoulos, P., & Lövblad, K. (2013) · Neuroscience · doi:10.1016/j.neuroscience.2013.07.021 · Cited by 56
Four‐phase single‐capillary stepwise model for kinetics in arterial spin labeling MRI
Li, K., Zhu, X., Hylton, N. M., Jahng, G., Weiner, M. W., & Schuff, N. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20390 · Cited by 53
Self-citationHayasaka, S., Du, A., Duarte, A., Kornak, J., Jahng, G., Weiner, M. W., & Schuff, N. W. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.052 · Cited by 51
Self-citationBrookes, M. J., Morris, P. G., Gowland, P. A., & Francis, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21199 · Cited by 50
Kao, Y., Guo, W., Wu, Y., Liu, K., Chai, W., Lin, C., Hwang, Y., Liou, A. J.-K., Wu, H., Cheng, H., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10440 · Cited by 50
Liang, X., Connelly, A., & Calamante, F. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.013 · Cited by 48
Self-citationArterial spin labeling with simultaneous multi‐slice echo planar imaging
Feinberg, D. A., Beckett, A. J. S., & Chen, L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24994 · Cited by 48
Parker, G. J. M., Baustert, I. C., Tanner, S. F., & Leach, M. O. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00124-1 · Cited by 46
Zanderigo, F., Bertoldo, A., Pillonetto, G., & Cobelli, C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013820 · Cited by 45
Whole brain perfusion measurements using arterial spin labeling with multiband acquisition
Kim, T., Shin, W., Zhao, T., Beall, E. B., Lowe, M. J., & Bae, K. T. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24880 · Cited by 40
Chappell, M. A., Okell, T. W., Jezzard, P., & Woolrich, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22524 · Cited by 39
Improved partial volume correction for single inversion time arterial spin labeling data
Liang, X., Connelly, A., & Calamante, F. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24279 · Cited by 36
Self-citationDual vessel arterial spin labeling scheme for regional perfusion imaging
Zimine, I., Petersen, E. T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21049 · Cited by 35
Li, K., Buonaccorsi, G. A., Thompson, G., Cain, J. R., Watkins, A., Russell, D., Qureshi, S., Evans, D. G., Lloyd, S., Zhu, X., et al. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23252 · Cited by 33
Self-citationMoody, A. R., Martel, A. L., Kenton, A., ALLDER, S., Horsfield, M. A., Delay, G. S., & Morgan, P. S. (2000) · Investigative Radiology · doi:10.1097/00004424-200007000-00002 · Cited by 32
Iterative blind deconvolution in magnetic resonance brain perfusion imaging
Grüner, R., & Taxt, T. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20850 · Cited by 29
Liang, X., Tournier, J., Masterton, R. A. J., Connelly, A., & Calamante, F. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22006 · Cited by 26
Self-citationJackson, A., Li, K., & Zhu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090300 · Cited by 26
Self-citationWater filtration and diffusion across the blood brain barrier in man.
Paulson, O. B., Hertz, M. M., Tg, B., & Lassen, N. A. (1977) · PubMed · Cited by 26
New developments in arterial spin labeling pulse sequences
Wong, E. C. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2954 · Cited by 24
Wu, Y., An, H., Krim, H., & Lin, W. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600374 · Cited by 15
Arterial spin labeling of cerebral perfusion territories using a separate labeling coil
Paiva, F. F., Tannús, A., Talagala, S. L., & Silva, A. C. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21320 · Cited by 14
Arterial spin labeling: its time is now
Alsop, D. C. (2012) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-012-0309-8 · Cited by 8
Wheeler-Kingshott (2000) · doi:10.1002/1522-2594(200011)44:5
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2<313::aid-jmri1045>3.0.co;2-w
Cited by
Bernardo-Castro, S., Sousa, J. A., Brás, A., Cecília, C., Rodrigues, B., Almendra, L., Machado, C., Santo, G., Silva, F., Ferreira, L., et al. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.594672 · Cited by 381
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F.
- Venue
- Korean Journal of Radiology
- Publisher
- XMLink
- Published
- 2014
- Volume
- 15
- Issue
- 5
- Pages
- 554
- ISSN
- 1229-6929 (ISSN-L)
- 2005-8330
- OpenAlex
- W2115962809
- Cited by
- 256
- References
- 116
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.