The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Multifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR‐II Probe
Open accessAbstract
Compared with imaging in the visible (400–650 nm) and near‐infrared window I (NIR‐I, 650–900 nm) regions, imaging in near‐infrared window II (NIR‐II, 1000–1700 nm) is a highly promising in vivo imaging modality with improved resolution and deeper tissue penetration. Here, a small molecule NIR‐II dye,5,5′‐(1H,5H‐benzo[1,2‐c:4,5‐c′] bis[1,2,5]thiadiazole)‐4,8‐diyl)bis(N,N‐bis(4‐(3‐((tert‐butyldimethylsilyl)oxy)propyl)phenyl) thiophen‐2‐amine), is successfully encapsulated into phospholipid vesicles to prepare a probe CQS1000. The novel NIR‐II probe is studied for in vivo multifunctional biological imaging. The results of this study indicate that the NIR‐II vesicle CQS1000 can noninvasively and dynamically visualize and monitor many physiological and pathological conditions of circulatory systems, including lymphatic drainage and routing, angiogenesis of tumor, and vascular deformity such as arterial thrombus formation and ischemia with high spatial and temporal resolution. More importantly, by virtue of the favorable half‐life of blood circulation of CQS1000, NIR‐II imaging is capable of aiding precise resection of tumor such as osteosarcoma and accelerating the process of lymph node dissection to complete sentinel lymph node biopsy for better decision making during the tumor surgery. Overall, CQS1000 is a highly promising NIR‐II probe for multifunctional biomedical imaging in physiological and pathological conditions, surpassing traditional NIR‐I imaging modality and pathologic assessments for clinical diagnosis and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liposomal drug delivery systems: From concept to clinical applications
Allen, T. M., & Cullis, P. R. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.037 · Cited by 4,839
O'Leary, D. H., Polak, J. F., Kronmal, R. A., Manolio, T. A., Burke, G. L., & Wolfson, S. K. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400103 · Cited by 4,685
Nanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233
Transplacental Carcinogenesis by Stilbestrol
Folkman, J. (1971) · New England Journal of Medicine · doi:10.1056/nejm197108122850711 · Cited by 2,640
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Traumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Cited by
Li, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Self-citationNear‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Jiang, Y., Li, J., Zhen, X., Xie, C., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201705980 · Cited by 601
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Self-citationDonor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Recent advances in near-infrared II fluorophores for multifunctional biomedical imaging
Ding, F., Zhan, Y., Lu, X., & Sun, Y. (2018) · Chemical Science · doi:10.1039/c8sc01153b · Cited by 538
Self-citationMiao, Q., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801778 · Cited by 537
Liu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 537
Self-citationJiang, Y., Upputuri, P. K., Xie, C., Lyu, Y., Zhang, L., Xiong, Q., Pramanik, M., & Pu, K. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02106 · Cited by 395
Self-citationWang, Q., Dai, Y., Xu, J., Cai, J., Niu, X., Zhang, L., Chen, R., Shen, Q., Huang, W., & Fan, Q. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201901480 · Cited by 369
Self-citationNIR-I-to-NIR-II fluorescent nanomaterials for biomedical imaging and cancer therapy
Zhao, J., Zhong, D., & Zhou, S. (2018) · Journal of Materials Chemistry B · doi:10.1039/c7tb02573d · Cited by 354
Zhu, S., Hu, Z., Tian, R., Yung, B. C., Yang, Q., Zhao, S., Kiesewetter, D. O., Niu, G., Sun, H., Antaris, A. L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802546 · Cited by 349
Self‐Assembling Peptide‐Based Hydrogels for Wound Tissue Repair
Guan, T., Li, J., Chen, C., & Liu, Y. (2022) · Advanced Science · doi:10.1002/advs.202104165 · Cited by 338
Imaging of Colorectal Cancers Using Activatable Nanoprobes with Second Near‐Infrared Window Emission
Xu, G., Yan, Q., Lv, X., Zhu, Y., Xin, K., Shi, B., Wang, R., Chen, J., Gao, W., Shi, P., et al. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712528 · Cited by 314
Yang, Y., Fan, X., Li, L., Yang, Y., Nuernisha, A., Xue, D., He, C., Qian, J., Hu, Q., Chen, H., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c00043 · Cited by 307
Self-citationConjugated Polymer Nanoparticles for Imaging, Cell Activity Regulation, and Therapy
Wang, Y., Feng, L., & Wang, S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806818 · Cited by 279
Liu, S., Ou, H., Li, Y., Zhang, H., Liu, J., Lu, X., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07193 · Cited by 277
Molecular Fluorophores for Deep-Tissue Bioimaging
Wang, S., Li, B., & Zhang, F. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00544 · Cited by 270
NIR-II bioimaging of small organic molecule
Su, Y., Yu, B., Wang, S., Cong, H., & Shen, Y. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120717 · Cited by 251
Cheng, K., Chen, H., Jenkins, C. H., Zhang, G., Zhao, W., Zhang, Z., Han, F., Fung, J., Yang, M., Jiang, Y., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05966 · Cited by 156
Self-citationYao, D., Wang, Y., Zou, R., Bian, K., Liu, P., Shen, S., Yang, W., Zhang, B., & Wang, D. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b20147 · Cited by 151
Zhang, W., Huang, T., Li, J., Sun, P., Wang, Y., Shi, W., Han, W., Wang, W., Fan, Q., & Huang, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02597 · Cited by 80
Swamy, M. M. M., Murai, Y., Monde, K., Tsuboi, S., & Jin, T. (2021) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.1c00253 · Cited by 59
Zhang, R., He, X., Jiang, J.-M., Li, P.-P., Wang, H.-Y., Li, L., Yang, J.-X., & Kong, L. (2021) · Bioorganic Chemistry · doi:10.1016/j.bioorg.2021.104789 · Cited by 7
Metadata
- Authors
- Shou, K., Qu, C., Sun, Y., Chen, H., Chen, S., Zhang, L., Xu, H., Hong, X., Yu, A., & Cheng, Z.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-04-24
- Volume
- 27
- Issue
- 23
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2609728077
- Cited by
- 209
- References
- 7
- FWCI
- 18.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.