The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
MRI‐based myelin water imaging: A technical review
Abstract
Multiexponential T2 relaxation time measurement in the central nervous system shows a component that originates from water trapped between the lipid bilayers of myelin. This myelin water component is of significant interest as it provides a myelin‐specific MRI signal of value in assessing myelin changes in cerebral white matter in vivo. In this article, the various acquisition and analysis strategies proposed to date for myelin water imaging are reviewed and research conducted into their validity and clinical applicability is presented. Comparisons between the imaging methods are made with a discussion regarding potential difficulties and model limitations. Magn Reson Med 73:70–81, 2015. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coefficient Alpha and the Internal Structure of Tests
Cronbach, L. J. (1951) · Psychometrika · doi:10.1007/bf02310555 · Cited by 43,931
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Functional connectivity in single and multislice echoplanar imaging using resting-state fluctuations
Lowe, M. J., Mock, B. J., & Sorenson, J. A. (1998) · NeuroImage · doi:10.1006/nimg.1997.0315 · Cited by 1,394
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Basic Neurochemistry: Molecular, Cellular, and Medical Aspects
Davison, A. (1989) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.8.1021-a · Cited by 941
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914
Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75611 · Cited by 800
In vivo measurement of T2 distributions and water contents in normal human brain
Whittall, K. P., Mackay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 793
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
The role of microglia and macrophages in the pathophysiology of the CNS
Stollg, G., & Jander, S. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00083-5 · Cited by 683
Quantitative interpretation of NMR relaxation data
Whittall, K. P., & MacKay, A. L. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90011-5 · Cited by 628
Exponential analysis in physical phenomena
Istratov, A. A., & Vyvenko, O. F. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149581 · Cited by 615
Brück, W., Bitsch, A., Kolenda, H., Brück, Y., Stiefel, M., & Lassmann, H. (1997) · Annals of Neurology · doi:10.1002/ana.410420515 · Cited by 519
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Practical T2 quantitation for clinical applications
Poon, C. S., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020512 · Cited by 393
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379
Water content and myelin water fraction in multiple sclerosis
Laule, C., Vavasour, I. M., Moore, G. R. W., Oger, J., Li, D. K. B., Paty, D. W., & MacKay, A. L. (2004) · Journal of Neurology · doi:10.1007/s00415-004-0306-6 · Cited by 369
Insights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347
GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique
Oshio, K., & Feinberg, D. A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200219 · Cited by 340
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Rapid whole cerebrum myelin water imaging using a 3D GRASE sequence
Prasloski, T., Rauscher, A., MacKay, A. L., Hodgson, M., Vavasour, I. M., Laule, C., & Mädler, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.064 · Cited by 268
Applications of stimulated echo correction to multicomponent T2 analysis
Prasloski, T., Mädler, B., Xiang, Q., MacKay, A., & Jones, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23157 · Cited by 253
Characterizing white matter with magnetization transfer andT2
Stanisz, G. J., Kecojevic, A., Bronskill, M. J., & Henkelman, R. M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1128::aid-mrm18>3.0.co;2-9 · Cited by 250
Quantitation of intrinsic magnetic susceptibility‐related effects in a tissue matrix. Phantom study
Yablonskiy, D. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390312 · Cited by 245
Hennig, J. (1991) · Concepts in Magnetic Resonance · doi:10.1002/cmr.1820030302 · Cited by 241
Analysis of biological NMR relaxation data with continuous distributions of relaxation times
Kroeker, R. M., & Mark Henkelman, R. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90074-0 · Cited by 210
Real‐time shimming to compensate for respiration‐induced B0 fluctuations
van Gelderen, P., de Zwart, J. A., Starewicz, P., Hinks, R. S., & Duyn, J. H. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21136 · Cited by 193
Age, gender, and hemispheric differences in iron deposition in the human brain: An in vivo MRI study
Xu, X., Wang, Q., & Zhang, M. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.017 · Cited by 193
Transverse relaxometry with stimulated echo compensation
Lebel, R. M., & Wilman, A. H. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22487 · Cited by 187
Du, Y. P., Chu, R., Hwang, D., Brown, M. S., Kleinschmidt‐DeMasters, B. K., Singel, D., & Simon, J. H. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21409 · Cited by 186
Criteria for analysis of multicomponent tissue T2 relaxation data
Graham, S. J., Stanchev, P. L., & Bronskill, M. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350315 · Cited by 179
Fischer, H. W., Rinck, P. A., van Haverbeke, Y., & Muller, R. N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160212 · Cited by 176
Christensen, K. A., Grant, D. M., Schulman, E. M., & Walling, C. (1974) · The Journal of Physical Chemistry · doi:10.1021/j100612a022 · Cited by 175
Is multicomponent T2 a good measure of myelin content in peripheral nerve?
Webb, S., Munro, C. A., Midha, R., & Stanisz, G. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10411 · Cited by 172
In vivo multi-slice mapping of myelin water content using T2* decay
Hwang, D., Kim, D.-H., & Du, Y. P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.023 · Cited by 169
Wilhelm, M. J., Ong, H. H., Wehrli, S. L., Li, C., Tsai, P.-H., Hackney, D. B., & Wehrli, F. W. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1115107109 · Cited by 168
Dula, A. N., Gochberg, D. F., Valentine, H. L., Valentine, W. M., & Does, M. D. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22267 · Cited by 156
Quantitative magnetization transfer imaging using balanced SSFP
Gloor, M., Scheffler, K., & Bieri, O. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21705 · Cited by 155
Broadband Decoupling in High-Resolution Nuclear Magnetic Resonance Spectroscopy
Levitt, M. H., Freeman, R., & Frenkiel, T. A. (1983) · Advances in magnetic and optical resonance · doi:10.1016/b978-0-12-025511-5.50008-6 · Cited by 154
Deoni, S., Matthews, L., & Kolind, S. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24429 · Cited by 150
Oh, J., Han, E. T., Pelletier, D., & Nelson, S. J. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.016 · Cited by 148
Postprocessing technique to correct for background gradients in image-basedR*2 measurements
Fernandez-Seara, M., & Wehrli, F. W. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<358::aid-mrm3>3.0.co;2-i · Cited by 146
Magnetization Transfer and T2 Relaxation Components in Tissue
Harrison, R., Bronskill, M. J., & Henkelman, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330406 · Cited by 140
Labadie, C., Lee, J. H., Rooney, W. D., Jarchow, S., Aubert-Frécon, M., SPRINGER, C. S. J., & Möller, H. E. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24670 · Cited by 138
Menon, R. S., & Allen, P. S. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200205 · Cited by 136
Three‐pool model of white matter
Lancaster, J. L., Andrews, T. J., Hardies, L. J., Dodd, S. J., & Fox, P. T. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10230 · Cited by 133
Stewart, W. A., MacKay, A. L., Whittall, K. P., Moore, G. R. W., & Paty, D. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290608 · Cited by 128
Horch, R. A., Gore, J. C., & Does, M. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22980 · Cited by 121
On the origin of apparent low tissue signals in balanced SSFP
Bieri, O., & Scheffler, K. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21056 · Cited by 116
Raj, D., Paley, D. P., Anderson, A. W., Kennan, R. P., & Gore, J. C. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/321 · Cited by 116
Compartmental study of T1 and T2 in rat brain and trigeminal nerve in vivo
Does, M. D., & Gore, J. C. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10060 · Cited by 115
Investigation of analysis techniques for complicated NMR relaxation data
Whittall, K. P., Bronskill, M. J., & Henkelman, R. M. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90213-d · Cited by 113
McCreary, C. R., Bjarnason, T. A., Skihar, V., Mitchell, J. R., Yong, V. W., & Dunn, J. F. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.071 · Cited by 107
Fast 3D imaging using variable‐density spiral trajectories with applications to limb perfusion
Lee, J. H., Hargreaves, B. A., Hu, B. S., & Nishimura, D. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10644 · Cited by 100
Characterization of the NMR behavior of white matter in bovine brain
Bjarnason, T. A., Vavasour, I. M., Chia, C. L. L., & MacKay, A. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20680 · Cited by 98
Harkins, K. D., Dula, A. N., & Does, M. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23053 · Cited by 94
Direct visualization of short transverse relaxation time component (ViSTa)
Oh, S., Bilello, M., Schindler, M. K., Markowitz, C., Detre, J. A., & Lee, J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.047 · Cited by 92
Water compartments in the myelinated nerve. III. Pulsed NMR result
Vasilescu, V., Katona, É., Simplăceanu, V., & Demco, D. E. (1978) · Cellular and Molecular Life Sciences · doi:10.1007/bf01932339 · Cited by 90
Proton Relaxation Studies of Water Compartmentalization in a Model Neurological System
Menon, R. S., Rusinko, M. S., & Allen, P. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280208 · Cited by 89
Simulations of NMR pulse sequences during equilibrium and non-equilibrium chemical exchange
Helgstrand, M., Härd, T., & Allard, P. (2000) · Journal of Biomolecular NMR · doi:10.1023/a:1008309220156 · Cited by 87
Levesque, I. R., & Pike, G. B. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22131 · Cited by 83
Self-citationOn the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Multi-component T1 relaxation and magnetisation transfer in peripheral nerve
Does, M. D., Beaulieu, C., Allen, P. S., & Snyder, R. E. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00139-8 · Cited by 83
k‐space detection and correction of physiological artifacts in fMRI
Wowk, B. G., McIntyre, M. C., & Saunders, J. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380625 · Cited by 79
Spencer, R. G. S., & Fishbein, K. W. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1925 · Cited by 78
Myelin water imaging: Implementation and development at 3.0T and comparison to 1.5T measurements
Kolind, S., Mädler, B., Fischer, S., Li, D. K. B., & MacKay, A. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21966 · Cited by 76
Multislice Brain Myelin Water Fractions at 3T in Multiple Sclerosis
Oh, J., Han, E. T., Lee, M., Nelson, S. J., & Pelletier, D. (2007) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2007.00098.x · Cited by 75
Nguyen, T. D., Wisnieff, C., Cooper, M. A., Kumar, D., Raj, A., Spincemaille, P., Wang, Y., Vartanian, T., & Gauthier, S. A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24128 · Cited by 74
Meyers, S. M., Vavasour, I. M., Mädler, B., Harris, T., Fu, E., Li, D. K. B., Traboulsee, A. L., MacKay, A. L., & Laule, C. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24106 · Cited by 72
Dortch, R. D., Harkins, K. D., Juttukonda, M. R., Gore, J. C., & Does, M. D. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24571 · Cited by 68
High‐resolution myelin water measurements in rat spinal cord
Kozłowski, P., Liu, J., Yung, A. C., & Tetzlaff, W. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21527 · Cited by 64
MT effects and T1 quantification in single‐slice spoiled gradient echo imaging
Ou, X., & Gochberg, D. F. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21550 · Cited by 62
Feasibility of in vivo myelin water imaging using 3D multigradient‐echo pulse sequences
Lenz, C., Klarhöfer, M., & Scheffler, K. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23241 · Cited by 57
T2 Accuracy on a whole‐body imager
Foltz, W. D., Stainsby, J. A., & Wright, G. A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380512 · Cited by 52
Robust myelin water quantification: Averaging vs. spatial filtering
Jones, C. K., Whittall, K. P., & MacKay, A. L. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10492 · Cited by 49
Reproducibility of in vivo magnetic resonance imaging–based measurement of myelin water
Levesque, I. R., Chia, C. L. L., & Pike, G. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22170 · Cited by 47
Self-citationInsight into in vivo magnetization exchange in human white matter regions
Kalantari, S., Laule, C., Bjarnason, T. A., Vavasour, I. M., & MacKay, A. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22873 · Cited by 47
Deoni, S., Rutt, B. K., & Jones, D. K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21079 · Cited by 46
Echo time optimization for linear combination myelin imaging
Vidarsson, L., Conolly, S., Lim, K. O., Gold, G. E., & Pauly, J. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20360 · Cited by 44
Reproducibility and reliability of MR measurements in white matter: Clinical implications
Vavasour, I. M., Clark, C. M., Li, D. K. B., & MacKay, A. L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.036 · Cited by 43
Quantitative T2 analysis: The effects of noise, regularization, and multivoxel approaches
Bjarnason, T. A., McCreary, C. R., Dunn, J. F., & Mitchell, J. R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22173 · Cited by 42
The Blood-Cerebrospinal Fluid Barrier
(2005) · CRC Press eBooks · doi:10.1201/9780367801007 · Cited by 40
Rapid three‐dimensional multicomponent relaxation imaging of the cervical spinal cord
Kolind, S., & Deoni, S. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22634 · Cited by 39
Disruption of the blood-cerebrospinal fluid barrier by transient cerebral ischemia
Nagahiro, S., Goto, S., Korematsu, K., Sumi, M., Takahashi, M., & Ushio, Y. (1994) · Brain Research · doi:10.1016/0006-8993(94)91553-9 · Cited by 39
Linear combination of multiecho data: Short T2 component selection
Jones, C. K., Xiang, Q., Whittall, K. P., & MacKay, A. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10713 · Cited by 38
Skinner, M. G., Kolind, S., & MacKay, A. L. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.09.046 · Cited by 34
Sahraian, M. A., & Radue, E. W. (2007) · Springer eBooks · doi:10.1007/978-3-540-71372-2 · Cited by 31
In vivo multiecho T2 relaxation measurements using variable TR to decrease scan time
Laule, C., Kolind, S., Bjarnason, T. A., Li, D. K. B., & MacKay, A. L. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.02.016 · Cited by 29
Rapid Acquisition Transverse Relaxometric Imaging
Does, M. D., & Gore, J. C. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2168 · Cited by 27
Temporal phase correction of multiple echo T2 magnetic resonance images
Bjarnason, T. A., Laule, C., Bluman, J., & Kozłowski, P. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.019 · Cited by 16
Intra and inter-site reproducibility of myelin water volume fraction values derived using McDESPOT.
Deoni, S., Samson, R. S., & Wheeler‐Kingshott, C. A. M. G. (2009) · UCL Discovery (University College London) · Cited by 9
Cited by
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
TE dependent Diffusion Imaging (TEdDI) distinguishes between compartmental T2 relaxation times
Veraart, J., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.030 · Cited by 212
Granberg, T., Fan, Q., Treaba, C. A., Ouellette, R., Herranz, E., Mangeat, G., Louapre, C., Cohen-Adad, J., Klawiter, E. C., Sloane, J. A., et al. (2017) · Brain · doi:10.1093/brain/awx247 · Cited by 184
Lazari, A., & Lipp, I. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117744 · Cited by 176
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Metadata
- Authors
- Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-03-06
- Volume
- 73
- Issue
- 1
- Pages
- 70-81
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1603992028
- Cited by
- 285
- References
- 95
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.