Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 318

The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.

Nuts and bolts of chemical exchange saturation transfer MRI

Open access
Liu, Guanshu, Song, Xiaolei, Chan, Kannie W. Y., McMahon, Michael T.·2013·NMR in Biomedicine

Abstract

Chemical exchange saturation transfer (CEST) has emerged as a novel MRI contrast mechanism that is well suited for molecular imaging studies. This new mechanism can be used to detect small amounts of contrast agent through the saturation of rapidly exchanging protons on these agents, allowing a wide range of applications. CEST technology has a number of indispensable features, such as the possibility of simultaneous detection of multiple ‘colors’ of agents and of changes in their environment (e.g. pH, metabolites, etc.) through MR contrast. Currently, a large number of new imaging schemes and techniques are being developed to improve the temporal resolution and specificity and to correct for the influence of B0 and B1 inhomogeneities. In this review, the techniques developed over the last decade are summarized with the different imaging strategies and post‐processing methods discussed from a practical point of view, including the description of their relative merits for the detection of CEST agents. The goal of the present work is to provide the reader with a fundamental understanding of the techniques developed, and to provide guidance to help refine future applications of this technology. This review is organized into three main sections (‘Basics of CEST contrast’, ‘Implementation’ and ‘Post‐processing’), and also includes a brief Introduction and Summary. The ‘Basics of CEST contrast’ section contains a description of the relevant background theory for saturation transfer and frequency‐labeled transfer, and a brief discussion of methods to determine exchange rates. The ‘Implementation’ section contains a description of the practical considerations in conducting CEST MRI studies, including the choice of magnetic field, pulse sequence, saturation pulse, imaging scheme, and strategies to separate magnetization transfer and CEST. The ‘Post‐processing’ section contains a description of the typical image processing employed for B0/B1 correction, Z‐spectral interpolation, frequency‐selective detection and improvement of CEST contrast maps. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.2899

Cites

114 of 114 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 318

Metadata

Authors
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2013-01-10
Volume
26
Issue
7
Pages
810-828
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2135788803
Cited by
318
References
114
FWCI
21.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.