Functional Magnetic Resonance Imaging with Echo Planar Imaging
The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Self-citationOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Analysis of functional MRI time‐series
Friston, K. J., Jezzard, P., & Turner, R. (1994) · Human Brain Mapping · doi:10.1002/hbm.460010207 · Cited by 1,682
Wada, J., & Rasmussen, T. (1960) · Journal of Neurosurgery · doi:10.3171/jns.1960.17.2.0266 · Cited by 1,576
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time
GRUBB, R. L., RAICHLE, M. E., EICHLING, J. O., & TER-POGOSSIAN, M. M. (1974) · Stroke · doi:10.1161/01.str.5.5.630 · Cited by 1,044
Engel, S. A., Rumelhart, D. E., Wandell, B. A., Lee, A. T., Glover, G. H., Chichilnisky, E.-J., & Shadlen, M. N. (1994) · Nature · doi:10.1038/369525a0 · Cited by 990
Functional Magnetic Resonance Imaging of Motor Cortex: Hemispheric Asymmetry and Handedness
Kim, S.-G., Ashe, J., Hendrich, K., Ellermann, J. M., Merkle, H., Uğurbil, K., & Georgopoulos, A. P. (1993) · Science · doi:10.1126/science.8342027 · Cited by 983
Frostig, R. D., Lieke, E. E., Ts'o, D. Y., & Grinvald, A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.16.6082 · Cited by 959
Functional magnetic resonance imaging of complex human movements
Rao, S. M., Binder, J. R., Bandettini, P. A., Hammeke, T. A., Yetkin, F. Z., Jesmanowicz, A., Lisk, L. M., Morris, G. L., Mueller, W. M., Estkowski, L. D., et al. (1993) · Neurology · doi:10.1212/wnl.43.11.2311 · Cited by 829
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Lactate rise detected by 1H NMR in human visual cortex during physiologic stimulation.
Prichard, J., Rothman, D., Novotny, E., Petroff, O., Kuwabara, T., Avison, M., Howseman, A., Hanstock, C., & Shulman, R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.13.5829 · Cited by 614
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Activation of a Cerebellar Output Nucleus During Cognitive Processing
Kim, S.-G., Uğurbil, K., & Strick, P. L. (1994) · Science · doi:10.1126/science.8052851 · Cited by 535
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Artifacts due to stimulus correlated motion in functional imaging of the brain
Hajnal, J. V., Myers, R., Oatridge, A., Schwieso, J. E., Young, I. R., & Bydder, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310307 · Cited by 486
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Self-citationEcho‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Functional magnetic resonance imaging of human auditory cortex
Binder, J. R., Rao, S. M., Hammeke, T. A., Yetkin, F. Z., Jesmanowicz, A., Bandettini, P. A., Wong, E. C., Estkowski, L. D., Goldstein, M. D., Haughton, V. M., et al. (1994) · Annals of Neurology · doi:10.1002/ana.410350606 · Cited by 399
Monitoring the patient's EEG during echo planar MRI
Ives, J. R., Warach, S., Schmitt, F., Edelman, R. R., & Schomer, D. L. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90156-p · Cited by 398
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Dynamic MR imaging of human brain oxygenation during rest and photic stimulation
Frahm, J., Bruhn, H., Merboldt, K., & Hänicke, W. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020505 · Cited by 385
Functional imaging of human motor cortex at high magnetic field
Kim, S. G., Ashe, J., Georgopoulos, A. P., Merkle, H., Ellermann, J. M., Menon, R. S., Ogawa, S., & Ugurbil, K. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.69.1.297 · Cited by 375
Jack, C. R., Thompson, R. M., Butts, R. K., Sharbrough, F. W., Kelly, P. J., Hanson, D. P., Riederer, S. J., Ehman, R. L., Hangiandreou, N. J., & Cascino, G. D. (1994) · Radiology · doi:10.1148/radiology.190.1.8259434 · Cited by 375
Dynamic mapping of the human visual cortex by high-speed magnetic resonance imaging.
Blamire, A. M., Ogawa, S., Ugurbil, K., Rothman, D., McCarthy, G., Ellermann, J. M., Hyder, F., Rattner, Z., & Shulman, R. G. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.22.11069 · Cited by 367
McCarthy, G., Blamire, A. M., Rothman, D. L., Gruetter, R., & Shulman, R. G. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.4952 · Cited by 366
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Functional MRI of human brain activation at high spatial resolution
Frahm, J., Merboldt, K., & Hänicke, W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290126 · Cited by 350
Bandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070104 · Cited by 349
Brain or veinoxygenation or flow? On signal physiology in functional MRI of human brain activation
Frahm, J., Merboldt, K., Hänicke, W., Kleinschmidt, A., & Boecker, H. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070108 · Cited by 342
Functional magnetic resonance imaging of Brocaʼs area during internal speech
Hinke, R. M., Hu, X., Stillman, A. E., Kim, S.-G., Merkle, H., Salmi, R., & Ugurbil, K. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00018 · Cited by 293
Activation of human primary visual cortex during visual recall: a magnetic resonance imaging study.
Le Bihan, D., Turner, R., Zeffiro, T. A., Cuénod, C. A., Jezzard, P., & Bonnerot, V (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.24.11802 · Cited by 290
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Somatotopic mapping of the human primary motor cortex with functional magnetic resonance imaging
Rao, S. M., Binder, J. R., Hammeke, T. A., Bandettini, P. A., Bobholz, J. A., Frost, J. A., Myklebust, B. M., Jacobson, R. D., & Hyde, J. S. (1995) · Neurology · doi:10.1212/wnl.45.5.919 · Cited by 281
Spiral K‐space MR imaging of cortical activation
Noll, D. C., Cohen, J. D., Meyer, C. H., & Schneider, W. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050112 · Cited by 254
Reduction of signal fluctuation in functional MRI using navigator echoes
Hu, X., & Kim, S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310505 · Cited by 252
Observation of a fast response in functional MR
Ernst, T., & Hennig, J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320122 · Cited by 240
15th annual meeting of the society for neuroscience
(1985) · Peptides · doi:10.1016/0196-9781(85)90125-1 · Cited by 238
Cohen, M. S., & Weisskoff, R. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90094-3 · Cited by 234
Inflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 T
Duyn, J. H., Moonen, C. T. W., van Yperen, G. H., de Boer, R. W., & Luyten, P. R. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070113 · Cited by 229
Potential pitfalls of functional MRI using conventional gradient‐recalled echo techniques
Kim, S., Hendrich, K., Hu, X., Merkle, H., & Uǧurbil, K. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070111 · Cited by 224
Functional topographic mapping of the cortical ribbon in human vision with conventional MRI scanners
Schneider, W., Noll, D. C., & Cohen, J. D. (1993) · Nature · doi:10.1038/365150a0 · Cited by 213
Haacke, E. M., Hopkins, A., Lai, S., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., Friedland, R., Klein, S., Thompson, L., et al. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070109 · Cited by 167
Functional mapping of activated human primary cortex with a clinical MR imaging system.
Connelly, A., Jackson, G. D., Frackowiak, R. S., Belliveau, J. W., Vargha-Khadem, F., & Gadian, D. G. (1993) · Radiology · doi:10.1148/radiology.188.1.8511285 · Cited by 163
Cao, Y., Vikingstad, E. M., Huttenlocher, P. R., Towle, V. L., & Levin, D. N. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.20.9612 · Cited by 141
Zhang, W., Williams, D. S., & Koretsky, A. P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290323 · Cited by 139
Magnetic resonance imaging of stationary blood: A review
Brooks, R. A., & Di Chiro, G. (1987) · Medical Physics · doi:10.1118/1.595994 · Cited by 137
Decrease of glucose in the human visual cortex during photic stimulation
Merboldt, K., Bruhn, H., Hanicke, W., Michaelis, T., & Frahm, J. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250119 · Cited by 129
Tyszka, J. M., Grafton, S. T., Chew, W., Woods, R. P., & Colletti, P. M. (1994) · Annals of Neurology · doi:10.1002/ana.410350617 · Cited by 125
Zhang, W., Williams, D. S., Detre, J. A., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250216 · Cited by 122
CSF‐suppressed quantitative single‐shot diffusion imaging
Kwong, K. K., McKinstry, R. C., Chien, D., Crawley, A. P., Pearlman, J. D., & Rosen, B. R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210120 · Cited by 119
Self-citationSimultaneous functional magnetic resonance imaging and electrophysiological recording
Huang‐Hellinger, F. R., Breiter, H. C., McCormack, G., Cohen, M. S., Kwong, K. K., Sutton, J. P., Savoy, R. L., Weisskoff, R. M., Davis, T. L., Baker, J. R., et al. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030103 · Cited by 117
Self-citationA quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain
Henkelman, R. M., Neil, J. J., & Xiang, Q. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320407 · Cited by 104
Localized 1H NMR measurement of glucose consumption in the human brain during visual stimulation.
Chen, W., Novotny, E. J., Zhu, X. H., Rothman, D. L., & Shulman, R. G. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9896 · Cited by 94
Functional NMR imaging using fast spin echo at 1.5 T
Constable, R. T., Kennan, R. P., Puce, A., McCarthy, G., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310617 · Cited by 93
Jezzard, P., Heineman, F. W., Taylor, J. F., Despres, D., Wen, H., Balaban, R. S., & Turner, R. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070107 · Cited by 88
Synthetic images by subspace transforms I. Principal components images and related filters
Sychra, J. J., Bandettini, P. A., Bhattacharya, N., & Lin, Q. (1994) · Medical Physics · doi:10.1118/1.597374 · Cited by 85
Spatial patterns of functional activation of the cerebellum investigated using high field (4 T) MRI
Ellerman, J. M., Flament, D., Kim, S. ‐., Fu, Q. ‐., Merkle, H., Ebner, T. J., & Ugurbil, K. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070110 · Cited by 80
Detection of brain activation using oxygenation sensitive functional spectroscopy
Hennig, J., Emst, T., Speck, O., Deuschl, G., & Feifel, E. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310115 · Cited by 68
Functional mapping of human motor cortical activation with conventional MR imaging at 1.5 T
Cao, Y., Towle, V. L., Levin, D. N., & Balter, J. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030613 · Cited by 66
Neil, J. J., Bosch, C. S., & Ackerman, J. J. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320109 · Cited by 57
Motor cortex stimulation measured by magnetic resonance imaging on a standard 1.5 T clinical scanner
Schad, L. R., Trost, U., Knopp, M. V., Müller, E., & Lorenz, W. J. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90464-o · Cited by 50
Detection of pseudodiffusion in rat brain following blood substitution with perfluorocarbon
Neil, J. J., & Ackerman, J. J. H. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90249-7 · Cited by 44
David, A. S., Blamire, A. M., & Breiter, H. (1994) · The British Journal of Psychiatry · doi:10.1192/bjp.164.1.2 · Cited by 41
Cho, Z., Ro, Y. M., Park, S. T., & Chung, S. T. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350102 · Cited by 36
A possible role of in-flow effects in functional MR-imaging
Gomišček, G., Beisteiner, R., Hittmair, K., Mueller, E., & Moser, E. (1993) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01769410 · Cited by 34
Hajnal, J. V., Collins, A. G., White, S. J., Pennock, J. M., Oatridge, A., Baudouin, C. J., YOUNG, I. R., & Bydder, G. M. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300520 · Cited by 32
A new T2*‐weighting technique for magnetic resonance imaging
Hu, X. P., & Kim, S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300417 · Cited by 22
Toward proton MR spectroscopic imaging of stimulated brain function
Singh, M. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159776 · Cited by 19
Merboldt, K., Krüger, G., Hänicke, W., Kleinschmidt, A. K., & Frahm, J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340423 · Cited by 18
Cited by
Whalen, P. J., Rauch, S. L., Etcoff, N. L., McInerney, S. C., Lee, M. B., & Jenike, M. A. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-01-00411.1998 · Cited by 2,205
“Our standard image acquisition protocol was used and previously has been detailed elsewhere (Cohen and Weisskoff, 1991; Kwong, 1995).”
MethodDynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Rauch, S. L., Whalen, P. J., Shin, L. M., McInerney, S. C., Macklin, M. L., Lasko, N. B., Orr, S. P., & Pitman, R. K. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(00)00828-3 · Cited by 1,111
“Further, lesion studies in animals suggest that medial frontal cortex may play a critical role in mediating the extinction of this learned association (Davis 1997; Morgan and LeDoux 1995).”
BackgroundPorro, C. A., Francescato, M. P., Cettolo, V., Diamond, M. E., Baraldi, P., Zuiani, C., Bazzocchi, M., & di Prampero, P. E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-23-07688.1996 · Cited by 924
“…T 2 * tissue relaxation-dependent proton signal increases can be detected by gradient-echo sequences on activation in specific brain regions, which are likely to reflect the interplay among local changes in blood flow, volume, and oxygenation (see Prichard and Rosen, 1994; Kwong, 1995).”
Background
Metadata
- Authors
- Kwong, K. K.
- Venue
- Functional MRI
- Publisher
- Springer Milan
- Published
- 1996
- Volume
- 11
- Issue
- 1
- Pages
- 73-90
- OpenAlex
- W1553065268
- Cited by
- 184
- References
- 88
- FWCI
- 66.88
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.