The DOI matches its Crossref record; 190 of the 190 references it cites were found in a registry or an index.
Emerging synergy between nanotechnology and implantable biosensors: A review
Open accessAbstract
The development of implantable biosensors for continuous monitoring of metabolites is an area of sustained scientific and technological interest. On the other hand, nanotechnology, a discipline which deals with the properties of materials at the nanoscale, is developing as a potent tool to enhance the performance of these biosensors. This article reviews the current state of implantable biosensors, highlighting the synergy between nanotechnology and sensor performance. Emphasis is placed on the electrochemical method of detection in light of its widespread usage and substantial nanotechnology-based improvements in various aspects of electrochemical biosensor performance. Finally, issues regarding toxicity and biocompatibility of nanomaterials, along with future prospects for the application of nanotechnology in implantable biosensors, are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum computation with quantum dots
Loss, D., & DiVincenzo, D. P. (1998) · Physical Review A · doi:10.1103/physreva.57.120 · Cited by 6,840 · cited 1×
“…2005), enhanced reactivity and catalytic activity (Bell 2003), faster electron/ion transport (Baetzold 1981; Kim et al. 2009), negative refractivity (Anantha Ramakrishna 2005) and novel quantum mechanical properties (Engheta et al. 2005; Loss 2009; Loss and DiVincenzo 1998) become pronounced.”
BackgroundElectrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Avouris, P., Chen, Z., & Perebeinos, V. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.300 · Cited by 2,533
The Impact of Nanoscience on Heterogeneous Catalysis
Bell, A. T. (2003) · Science · doi:10.1126/science.1083671 · Cited by 2,510
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Gold Nanoparticles Are Taken Up by Human Cells but Do Not Cause Acute Cytotoxicity
Connor, E. E., Mwamuka, J., Gole, A., Murphy, C. J., & Wyatt, M. D. (2005) · Small · doi:10.1002/smll.200400093 · Cited by 2,406
Carbon‐Nanotube Based Electrochemical Biosensors: A Review
Wang, J. (2005) · Electroanalysis · doi:10.1002/elan.200403113 · Cited by 2,387
van Gelder, H. A. E. (1961) · The Two Reformations in the 16th Century · doi:10.1007/978-94-011-9562-1_10 · Cited by 1,652
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,646
Nanoelectronics from the bottom up
Lu, W., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,545
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Nanoparticles – known and unknown health risks
Hoet, P. H., Brüske-Hohlfeld, I., & Salata, O. V. (2004) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-2-12 · Cited by 1,374
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Electrochemical Biosensing Platforms Using Platinum Nanoparticles and Carbon Nanotubes
Hrapovic, S., Liu, Y., Male, K. B., & Luong, J. H. T. (2004) · Analytical Chemistry · doi:10.1021/ac035143t · Cited by 1,064
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Physics of negative refractive index materials
Ramakrishna, S. A. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/2/r06 · Cited by 900
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Nanostructures for enzyme stabilization
Kim, J., Grate, J. W., & Wang, P. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2005.05.067 · Cited by 842
Carbon nanotubes as nanomedicines: From toxicology to pharmacology☆
LACERDA, L., BIANCO, A., PRATO, M., & KOSTARELOS, K. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.015 · Cited by 839
Advances in polymers for anti-biofouling surfaces
Krishnan, S., Weinman, C. J., & Ober, C. K. (2008) · Journal of Materials Chemistry · doi:10.1039/b801491d · Cited by 824
Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Charge- and size-based separation of macromolecules using ultrathin silicon membranes
Striemer, C. C., Gaborski, T. R., McGrath, J. L., & Fauchet, P. M. (2007) · Nature · doi:10.1038/nature05532 · Cited by 753
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Biomolecule‐Functionalized Carbon Nanotubes: Applications in Nanobioelectronics
Katz, E., & Willner, I. (2004) · ChemPhysChem · doi:10.1002/cphc.200400193 · Cited by 749
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Circuit Elements at Optical Frequencies: Nanoinductors, Nanocapacitors, and Nanoresistors
Engheta, N., Salandrino, A., & Alù, A. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.095504 · Cited by 660
Jia, J., Wang, B., Wu, A., Cheng, G., Li, Z., & Dong, S. (2002) · Analytical Chemistry · doi:10.1021/ac011116w · Cited by 653
Conformal Coating on Ultrahigh-Aspect-Ratio Nanopores of Anodic Alumina by Atomic Layer Deposition
Elam, J. W., Routkevitch, D., Mardilovich, P. P., & George, S. M. (2003) · Chemistry of Materials · doi:10.1021/cm0303080 · Cited by 623
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Mano, N., Mao, F., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0346328 · Cited by 573
Popat, K. C., Eltgroth, M., LaTempa, T. J., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.037 · Cited by 561
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · cited 3×
“…forms a mass transfer barrier for analyte (glucose, lactate, etc.) diffusion to the sensing element, thereby degrading the in vivo sensor performance and long-term stability (Bhardwaj et al. 2008; Gerritsen et al. 1999; Gifford et al. 2006; Onuki et al. 2008; Wisniewski and Reichert 2000).”
BackgroundNonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Plastic-Compatible Low Resistance Printable Gold Nanoparticle Conductors for Flexible Electronics
Huang, D., Liao, F., Molesa, S., Redinger, D., & Subramanian, V. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1582466 · Cited by 524
Enzyme immobilization on electrospun polymer nanofibers: An overview
Wang, Z.-G., Wan, L.-S., Liu, Z.-M., Huang, X.-J., & Xu, Z.-K. (2009) · Journal of Molecular Catalysis B: Enzymatic · doi:10.1016/j.molcatb.2008.05.005 · Cited by 523
Aspartate Aminotransferase (AST/GOT) and Alanine Aminotransferase (ALT/GPT) Detection Techniques
Huang, X.-J., Choi, Y.-K., Im, H.-S., Yarimaga, O., Yoon, E., & Kim, H.-S. (2006) · Sensors · doi:10.3390/s6070756 · Cited by 520
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Ductility of Nanostructured Materials
Koch, C. C., Morris, D. G., Lu, K., & Inoue, A. (1999) · MRS Bulletin · doi:10.1557/s0883769400051551 · Cited by 517
Carbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules
Kim, S. N., Rusling, J. F., & Papadimitrakopoulos, F. (2007) · Advanced Materials · doi:10.1002/adma.200700665 · Cited by 502
Self-citationCross-linked redox gels containing glucose oxidase for amperometric biosensor applications
Gregg, B. A., & Heller, A. (1990) · Analytical Chemistry · doi:10.1021/ac00202a007 · Cited by 479
Nanoelectrodes, nanoelectrode arrays and their applications
Arrigan, D. W. M. (2004) · The Analyst · doi:10.1039/b415395m · Cited by 461
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W. (2006) · Applied Physics Letters · doi:10.1063/1.2356307 · Cited by 442
Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications
Ghindilis, A. L., Atanasov, P., & Wilkins, E. (1997) · Electroanalysis · doi:10.1002/elan.1140090902 · Cited by 440
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Chen, T., Barton, S. C., Binyamin, G., Gao, Z., Zhang, Y., Kim, H.-H., & Heller, A. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0163164 · Cited by 427
Nanobiocatalysis and its potential applications
Kim, J., Grate, J. W., & Wang, P. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.07.009 · Cited by 423
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Self-citationMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Welch, C. M., Banks, C. E., Simm, A. O., & Compton, R. G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3205-5 · Cited by 402
Characterization of implantable biosensor membrane biofouling
Wisniewski, N., Moussy, F., & Reichert, W. M. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 350
Yang, M., Yang, Y., Liu, Y., Shen, G., & Yu, R. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.04.009 · Cited by 348
Toxicology of carbon nanomaterials: Status, trends, and perspectives on the special issue
Hurt, R. H., Monthioux, M., & Kane, A. (2006) · Carbon · doi:10.1016/j.carbon.2005.12.023 · Cited by 343
Liu, Q., Lu, X., Li, J., Yao, X., & Li, J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.02.013 · Cited by 340
Spider silks and their applications
Kluge, J. A., Rabotyagova, O., Leisk, G. G., & Kaplan, D. L. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.02.006 · Cited by 338
Hu, Y., & Wilson, G. S. (1997) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1997.69041484.x · Cited by 337
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 335
Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes
Ye, J.-S., Wen, Y., De Zhang, W., Ming Gan, L., Xu, G. Q., & Sheu, F.-S. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.10.013 · Cited by 325
A Miniature Biofuel Cell Operating in A Physiological Buffer
Mano, N., Mao, F., & Heller, A. (2002) · Journal of the American Chemical Society · doi:10.1021/ja028514g · Cited by 306
Roadmap for 22nm and beyond (Invited Paper)
Iwai, H. (2009) · Microelectronic Engineering · doi:10.1016/j.mee.2009.03.129 · Cited by 300
A Conducting Polymer Nanojunction Sensor for Glucose Detection
Forzani, E. S., Zhang, H., Nagahara, L. A., Amlani, I., Tsui, R., & Tao, N. (2004) · Nano Letters · doi:10.1021/nl049080l · Cited by 293
Tang, H., Chen, J., Yao, S., Nie, L., Deng, G., & Kuang, Y. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.05.005 · Cited by 282
Ohara, T. J., Rajagopalan, R., & Heller, A. (1993) · Analytical Chemistry · doi:10.1021/ac00071a031 · Cited by 281
Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo. A review
O'Neill, R. D. (1994) · The Analyst · doi:10.1039/an9941900767 · Cited by 270
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268 · cited 1×
“Poly (lactic-co-glycolic acid) (PLGA) is the commonly used materials for microspheres (Hickey et al. 2002a, b).”
MethodSelf-citationAmperometric Biosensors Based on Redox Polymer−Carbon Nanotube−Enzyme Composites
Joshi, P. P., Merchant, S. A., Wang, Y., & Schmidtke, D. W. (2005) · Analytical Chemistry · doi:10.1021/ac0484169 · Cited by 262
Engineering the tissue which encapsulates subcutaneous implants. I. Diffusion properties
Sharkawy, A. A., Klitzman, B., Truskey, G. A., & Reichert, W. M. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3<401::aid-jbm11>3.0.co;2-e · Cited by 238
Can continuous glucose monitoring be used for the treatment of diabetes?
Reach, G., & Wilson, G. S. (1992) · Analytical Chemistry · doi:10.1021/ac00030a001 · Cited by 235
Harrison, D. J., Turner, R. F. B., & Baltes, H. P. (1988) · Analytical Chemistry · doi:10.1021/ac00170a003 · Cited by 232
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230
Self-citationLuckarift, H. R., Dickerson, M. B., Sandhage, K. H., & Spain, J. C. (2006) · Small · doi:10.1002/smll.200500376 · Cited by 227
A new class of amperometric biosensor incorporating a polymeric electron-transfer mediator
Hale, P. D., Inagaki, T., Karan, H. I., Okamoto, Y., & Skotheim, T. A. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00191a084 · Cited by 226
Chen, S., Yuan, R., Chai, Y., Zhang, L., Wang, N., & Li, X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.022 · Cited by 223
Two-dimensional enzyme electrode sensor for glucose
Gough, D. A., Lucisano, J. Y., & Tse, P. H. S. (1985) · Analytical Chemistry · doi:10.1021/ac00289a042 · Cited by 223
Designing synthetic materials to control stem cell phenotype
Saha, K., Pollock, J. F., Schaffer, D. V., & Healy, K. E. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.05.030 · Cited by 219
Hall, S. B., Khudaish, E. A., & Hart, A. L. (1998) · Electrochimica Acta · doi:10.1016/s0013-4686(97)00125-4 · Cited by 218
Zayats, M., Katz, E., Baron, R., & Willner, I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052841h · Cited by 210
An Ink-Jet-Deposited Passive Component Process for RFID
Redinger, D., Molesa, S., Yin, S., Farschi, R., & Subramanian, V. (2004) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2004.838451 · Cited by 206
Bowden, E. F., Hawkridge, F. M., & Blount, H. N. (1984) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(84)80193-x · Cited by 202
Microfabricated immunoisolating biocapsules
Desai, T. A., Chu, W. H., Tu, J. K., Beattie, G. M., Hayek, A., & Ferrari, M. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19980105)57:1<118::aid-bit14>3.0.co;2-g · Cited by 195
Third-Generation Biosensors Based on the Direct Electron Transfer of Proteins
Zhang, W., & Li, G. (2004) · Analytical Sciences · doi:10.2116/analsci.20.603 · Cited by 192
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10016 · Cited by 187
Self-citationRapid Changes in Local Extracellular Rat Brain Glucose Observed with an In Vivo Glucose Sensor
Hu, Y., & Wilson, G. S. (1997) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1997.68041745.x · Cited by 186
- Amperometric Enzyme Electrodes
(2015) · Electrochemical Biosensors · doi:10.1201/b15659-6 · Cited by 181
Application of Chronic Intravascular Blood Glucose Sensor in Dogs
Armour, J. C., Lucisano, J. Y., McKean, B. D., & Gough, D. A. (1990) · Diabetes · doi:10.2337/diab.39.12.1519 · Cited by 175
Amperometric enzyme electrodes
Albery, W. J., Bartlett, P. N., & Craston, D. H. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85006-3 · Cited by 170
Galeska, I., Kim, T.-K., Patil, S. D., Bhardwaj, U., Chatttopadhyay, D., Papadimitrakopoulos, F., & Burgess, D. J. (2005) · The AAPS Journal · doi:10.1208/aapsj070122 · Cited by 170
Self-citationIn Vivo Chemical Sensors: Tackling Biocompatibility
Frost, M. C., & Meyerhoff, M. E. (2006) · Analytical Chemistry · doi:10.1021/ac069475k · Cited by 163
Nanoporous anti-fouling silicon membranes for biosensor applications
Desai, T. A., Hansford, D. J., Leoni, L., Essenpreis, M., & Ferrari, M. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00088-9 · Cited by 163
All-polymer capacitor fabricated with inkjet printing technique
Liu, Y., Cui, T., & Varahramyan, K. (2003) · Solid-State Electronics · doi:10.1016/s0038-1101(03)00082-0 · Cited by 162
Gold nanoparticles integrated in a nanotube array for electrochemical detection of glucose
Zhou, Y.-G., Yang, S., Qian, Q.-Y., & Xia, X.-H. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2008.11.010 · Cited by 160
Moussy, F., Harrison, D. J., O'Brien, D. W., & Rajotte, R. V. (1993) · Analytical Chemistry · doi:10.1021/ac00063a023 · Cited by 158
Toxicity and Biocompatibility of Carbon Nanoparticles
Fiorito, S., Serafino, A., Andreola, F., Togna, A., & Togna, G. (2006) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2006.125 · Cited by 158
Polymer–Nanotube–Enzyme Composites as Active Antifouling Films
Asuri, P., Karajanagi, S. S., Kane, R. S., & Dordick, J. S. (2006) · Small · doi:10.1002/smll.200600312 · Cited by 156
Nanocomposites: From Fabrications to Electrochemical Bioapplications
Xiao, Y., & Li, C. M. (2008) · Electroanalysis · doi:10.1002/elan.200704125 · Cited by 153
Martin, F., Walczak, R. J., Boiarski, A. A., Cohen, M. J., West, T., Cosentino, C., & Mauro Ferrari, B. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.09.024 · Cited by 150
Engineered Microcapsules Fabricated from Reconstituted Spider Silk
Hermanson, K. D., Huemmerich, D., Scheibel, T., & Bausch, A. R. (2007) · Advanced Materials · doi:10.1002/adma.200602709 · Cited by 142
Yu, B., Long, N., Moussy, Y., & Moussy, F. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.002 · Cited by 141 · cited 5×
“…(covering the surface of the working electrode) that are used to either immobilize enzymes or eliminate interferences (McMahon et al. 2005), and (v) the presence of an outer membrane required to alleviate oxygen dependence and/or to prevent biofouling (Vaddiraju et al. 2008; Yu et al. 2006a).”
BackgroundInfluentialPerformance of subcutaneously implanted glucose sensors for continuous monitoring
Gerritsen, M., Jansen, J. A., & Lutterman, J. A. (1999) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(99)00006-6 · Cited by 140
Microsystem technologies for implantable applications
Receveur, R. A. M., Lindemans, F. W., & de Rooij, N. F. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r02 · Cited by 138
Application of quantum chemistry to nanotechnology: electron and spin transport in molecular devices
Kim, W. Y., Choi, Y. C., Min, S. K., Cho, Y., & Kim, K. S. (2009) · Chemical Society Reviews · doi:10.1039/b820003c · Cited by 133
Wisniewski, N., Klitzman, B. M., Miller, B., & Reichert, W. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4<513::aid-jbm1197>3.0.co;2-e · Cited by 131
Ainslie, K. M., & Desai, T. A. (2008) · Lab on a Chip · doi:10.1039/b806446f · Cited by 131
Third-Generation Biosensor for Lactose Based on Newly Discovered Cellobiose Dehydrogenase
Stoica, L., Ludwig, R., Haltrich, D., & Gorton, L. G. O. (2005) · Analytical Chemistry · doi:10.1021/ac050327o · Cited by 129
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128
Kang, B. S., Wang, H. T., Ren, F., Pearton, S. J., Morey, T. E., Dennis, D. M., Johnson, J. W., Rajagopal, P., Roberts, J. C., Piner, E. L., et al. (2007) · Applied Physics Letters · doi:10.1063/1.2825574 · Cited by 128
Ishihara, K., Tanaka, S., Furukawa, N., Nakabayashi, N., & Kurita, K. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<391::aid-jbm12>3.0.co;2-k · Cited by 118
Layered Titanate Nanosheets Intercalated with Myoglobin for Direct Electrochemistry
Zhang, L., Zhang, Q., & Li, J. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200600991 · Cited by 118
Protein interactions with subcutaneously implanted biosensors
Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.033 · Cited by 117
Palmisano, F., Zambonin, P. G., Centonze, D., & Quinto, M. (2002) · Analytical Chemistry · doi:10.1021/ac0258608 · Cited by 117
Manipulating redox systems: application to nanotechnology
Gilardi, G., & Fantuzzi, A. (2001) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01769-3 · Cited by 114
Yu, X., Kim, S. N., Papadimitrakopoulos, F., & Rusling, J. F. (2005) · Molecular BioSystems · doi:10.1039/b502124c · Cited by 113
Self-citationBharathi, S., & Nogami, M. (2001) · The Analyst · doi:10.1039/b105318n · Cited by 111
Sharkawy, A. A., Klitzman, B. M., Truskey, G. A., & Reichert, W. M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4<598::aid-jbm11>3.0.co;2-c · Cited by 110
Nanoporous microsystems for islet cell replacement
Desai, T. A., West, T., Cohen, M. J., Boiarski, T., & Rampersaud, A. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.11.006 · Cited by 107
Yoon, H., Ko, S., & Jang, J. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp800567h · Cited by 101
Myung, Y., Jang, D. M., Cho, Y. J., Kim, H. S., Park, J., Kim, J.-U., Choi, Y., & Lee, C. J. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp806633j · Cited by 101
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99
Self-citationKhan, G. F., Ohwa, M., & Wernet, W. (1996) · Analytical Chemistry · doi:10.1021/ac9510393 · Cited by 98
A reagentless nitric oxide biosensor based on hemoglobin–DNA films
Fan, C., Li, G., Zhu, J., & Zhu, D. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)01093-x · Cited by 97
Nanotechnology: Basic Concepts and Definitions
Kaehler, T. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.9.1797b · Cited by 96
Frost, M. C., Rudich, S. M., Zhang, H., Maraschio, M., & Meyerhoff, M. E. (2002) · Analytical Chemistry · doi:10.1021/ac025944g · Cited by 93
Evaluation of a Subcutaneous Glucose Sensor out to 3 Months in a Dog Model
GILLIGAN, B. J., Shults, M. C., Rhodes, R. K., & Updike, S. J. (1994) · Diabetes Care · doi:10.2337/diacare.17.8.882 · Cited by 90
Recent advances in carbon nanotube-based electronics
Sharma, P., & Ahuja, P. (2007) · Materials Research Bulletin · doi:10.1016/j.materresbull.2007.10.012 · Cited by 87
Effect of surface treatment on unalloyed titanium implants: Spectroscopic analyses
Kilpadi, D. V., Raikar, G. N., Liu, J., Lemons, J. E., Vohra, Y. K., & Gregory, J. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4<586::aid-jbm10>3.0.co;2-e · Cited by 86
Nanoporous materials for biomedical devices
Adiga, S. P., Curtiss, L. A., Elam, J. W., Pellin, M. J., Shih, C.-C., Shih, C., Lin, S., Su, Y.-Y., Gittard, S. D., Zhang, J., et al. (2008) · JOM · doi:10.1007/s11837-008-0028-9 · Cited by 84
Needle-Type Dual Microsensor for the Simultaneous Monitoring of Glucose and Insulin
Wang, J., & Zhang, X. (2001) · Analytical Chemistry · doi:10.1021/ac0009393 · Cited by 81
Ryu, W., Huang, Z., Prinz, F. B., Goodman, S. B., & Fasching, R. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.08.024 · Cited by 80
Flexible biosensors on spirally rolled micro tube for cardiovascular in vivo monitoring
Li, C., Han, J., & Ahn, C. H. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.043 · Cited by 79
Amperometric Glucose Sensors Based on Immobilized Glucose Oxidase-Polyquinone System
Kaku, T., Karan, H. I., & Okamoto, Y. (1994) · Analytical Chemistry · doi:10.1021/ac00080a006 · Cited by 79
Immobilization Techniques to Avoid Enzyme Loss from Oxidase-Based Biosensors: A One-Year Study
House, J. L., Anderson, E. M., & Ward, W. K. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100104 · Cited by 78
Barton, A. C., Collyer, S. D., Davis, F., Gornall, D. D., Law, K. A., Lawrence, E. C. D., Mills, D. W., Myler, S., Pritchard, J. A., Thompson, M., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.002 · Cited by 77
Kerner, W., Kiwit, M., Linke, B., Keck, F. S., Zier, H., & Pfeiffer, E. F. (1993) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(93)80032-k · Cited by 75
In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
Johnson, K. W., Mastrototaro, J. J., Howey, D. C., Brunelle, R. L., Burden-Brady, P. L., Bryan, N. A., Andrew, C. C., Rowe, H., Allen, D. J., Noffke, B. W., et al. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85053-d · Cited by 73
Organic Photodiodes for Biosensor Miniaturization
Wojciechowski, J., Shriver‐Lake, L. C., Yamaguchi, M. Y., Füreder, E., Pieler, R., Schamesberger, M., Winder, C., Prall, H.-J., Sonnleitner, M., & Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac8027323 · Cited by 72
Development of needle-type glucose sensor with high selectivity
Yang, Q., Atanasov, P., & Wilkins, E. S. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00126-9 · Cited by 72
Galeska, I., Hickey, T., Moussy, F. G., Kreutzer, D. L., & Papadimitrakopoulos, F. (2001) · Biomacromolecules · doi:10.1021/bm010112y · Cited by 71
Self-citationPolymer−Enzyme Composite Biosensor with High Glutamate Sensitivity and Low Oxygen Dependence
McMahon, C. P., & O'Neill, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac048686r · Cited by 70
New technology for multi-sensor silicon needles for biomedical applications
Errachid, A., Ivorra, A., Aguiló, J., Villa, R., Zine, N., & Bausells, J. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00826-7 · Cited by 68
In vitro Immunogenicity of Silicon-Based Micro- and Nanostructured Surfaces
Ainslie, K. M., Tao, S. L., Popat, K. C., & Desai, T. A. (2008) · ACS Nano · doi:10.1021/nn800071k · Cited by 67
Microfabrication of Multilayer, Asymmetric, Polymeric Devices for Drug Delivery
Tao, S. L., & Desai, T. A. (2005) · Advanced Materials · doi:10.1002/adma.200500017 · Cited by 66
WU, Y., ROJAS, A., GRIFFITH, G., SKRZYPCHAK, A., LAFAYETTE, N., BARTLETT, R., & MEYERHOFF, M. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.025 · Cited by 65 · cited 3×
“The deposition of active cells on the surface of implantable sensors can also cause a significant change in the local oxygen concentration, which also can lead to significant errors in the response of the implantable biosensor (Wu et al. 2007).”
BackgroundPreparation and characterization of implantable sensors with nitric oxide release coatings
Frost, M. C., Batchelor, M. M., Lee, Y.-M., Zhang, H., Kang, Y., Oh, B. K., Wilson, G. S., Gifford, R., Rudich, S. M., & Meyerhoff, M. E. (2003) · Microchemical Journal · doi:10.1016/s0026-265x(03)00033-x · Cited by 65
Lowry, J. P., & Fillenz, M. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00109-8 · Cited by 65
Detection of Interaction Between Metal Complex Indicator and DNA by Using Electrochemical Biosensor
Erdem, A., Meriç, B., Kerman, K., Dalbastı, T., & Özsöz, M. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199912)11:18<1377::aid-elan1377>3.0.co;2-b · Cited by 64
Male, K. B., Hrapovic, S., & Luong, J. H. T. (2007) · The Analyst · doi:10.1039/b712478c · Cited by 63
Yu, X., Sotzing, G. A., Papadimitrakopoulos, F., & Rusling, J. F. (2003) · Analytical Chemistry · doi:10.1021/ac034188r · Cited by 57
Self-citationEnzymatic glucose sensors. Improved long-term performance in vitro and in vivo.
Updike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · PubMed · Cited by 57
McMahon, C. P., Killoran, S. J., & O'Neill, R. D. (2005) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2005.03.026 · Cited by 55
Evaluation of silicon nanoporous membranes and ECM-based microenvironments on neurosecretory cells
A, C. A. L., Fleischman, A. J., Roy, S., & Desai, T. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.017 · Cited by 53
Updike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · ASAIO Journal · doi:10.1097/00002480-199404000-00007 · Cited by 52
Calcification-Resistant Nafion/Fe3+ Assemblies for Implantable Biosensors
Galeska, I., Chattopadhyay, D., Moussy, F. G., & Papadimitrakopoulos, F. (2000) · Biomacromolecules · doi:10.1021/bm0002813 · Cited by 50
Self-citationA third-generation hydrogen peroxide biosensor fabricated with hemoglobin and Triton X-100
Liu, X., Xu, Y., Ma, X., & Li, G. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.08.010 · Cited by 50
Glucose sensor with improved haemocompatibilty
Yang, Y., Zhang, S. F., Kingston, M. A., Jones, G., Wright, G., & Spencer, S. A. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00082-8 · Cited by 49
Enhanced Glucose Sensor Linearity Using Poly(Vinyl Alcohol) Hydrogels
Vaddiraju, S., Singh, H., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300434 · Cited by 49
Self-citationCoil-type implantable glucose biosensor with excess enzyme loading
Yu, B. (2005) · Frontiers in bioscience · doi:10.2741/1547 · Cited by 48
Corcuera, J. I. R. D., Cavalieri, R. P., & Powers, J. R. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.09.015 · Cited by 47
Sources of instability of ‘wired’ enzyme anodes in serum: urate and transition metal ions
Binyamin, G. N., Chen, T., & Heller, A. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00267-9 · Cited by 44
Platinum nanoparticle-modified carbon fiber ultramicroelectrodes for mediator-free biosensing
Wu, Z., Chen, L., Shen, G., & Yu, R. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.12.023 · Cited by 44
Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200611 · Cited by 43
Self-citationThe role of H2O2 outer diffusion on the performance of implantable glucose sensors
Vaddiraju, S., Burgess, D. J., Jain, F., & Papadimitrakopoulos, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.015 · Cited by 42
Self-citationBio‐/haemocompatibility: implications and outcomes for sensors?
Kyröläinen, M., Rigsby, P., Eddy, S., & Vadgama, P. M. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04255.x · Cited by 41
Enzyme sensors prepared by electrodeposition on platinized platinum electrodes
Kim, C. S., & Oh, S. M. (1996) · Electrochimica Acta · doi:10.1016/0013-4686(96)00030-8 · Cited by 41
Layer-by-Layer Assembled Semipermeable Membrane for Amperometric Glucose Sensors
Tipnis, R., Vaddiraju, S., Jain, F., Burgess, D. J., & Papadimitrakopoulos, F. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100209 · Cited by 41
Self-citationGlucose detection based on electrochemically formed Ir oxide films
Abu‐Irhayem, E., Elżanowska, H., Jhas, A. S., Skrzynecka, B., & Birss, V. I. (2002) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(02)01142-7 · Cited by 40
Kvist, P. H., Iburg, T. M., Aalbæk, B., Gerstenberg, M., Schoier, C., Kaastrup, P., Buch‐Rasmussen, T., Hasselager, E., & Jensen, H. E. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.546 · Cited by 39
Kohma, T., Oyamatsu, D., & Kuwabata, S. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.12.015 · Cited by 39
Amperometric Glucose Biosensor Based on Rhodium Dioxide‐Modified Carbon Ink
Kotzian, P., Brázdilová, P., Řezková, S., Kalcher, K., & Vytřas, K. (2006) · Electroanalysis · doi:10.1002/elan.200503549 · Cited by 38
Sachs, H. G., Schanze, T., Brunner, U., Sailer, H., & Wiesenack, C. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/008 · Cited by 38
Free-Standing Nanogold Membranes as Scaffolds for Enzyme Immobilization
Phadtare, S., Vathipadiekal, V., Wadgaonkar, P. P., Rao, M., & Sastry, M. (2004) · Langmuir · doi:10.1021/la035870j · Cited by 37
Anti‐inflammatory properties of micropatterned titanium coatings
Sahlin, H., Contreras, R., Gaskill, D. F., Bjursten, L. M., & Frangos, J. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30642 · Cited by 36
Poly-o-phenylenediamine as redox mediator for laccase
Pałys, B., Bokun, A. A., & Rogalski, J. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.05.029 · Cited by 33
Baravik, I. K., Tel‐Vered, R., Ovits, O., & Willner, I. (2009) · Langmuir · doi:10.1021/la902074w · Cited by 31
Novel Hyaluronic Acid Coating for Potential Use in Glucose Sensor Design
Praveen, S., Hanumantha, R., Belovich, J., & Davis, B. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503765691893 · Cited by 29
Crespi, F. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90152-j · Cited by 29
Summary and Future Perspectives
Smith, W. K., Nobel, P. S., Reiners, W. A., Vogelmann, T. C., & Critchley, C. (2004) · Ecological studies · doi:10.1007/0-387-27267-4_11 · Cited by 26
A Wire-Based Dual-Analyte Sensor for Glucose and Lactate: In Vitro and In Vivo Evaluation
Ward, W. K., House, J. L., Birck, J., Anderson, E. M., & Jansen, L. B. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198106 · Cited by 25
Tamiya, E., Sugiura, Y., Takeuchi, T., Suzuki, M., Karube, I., & Akiyama, A. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)87003-8 · Cited by 23
Thermostable Peroxidase−Polylysine Films for Biocatalysis at 90 °C
Guto, P. M., Kumar, C. V., & Rusling, J. F. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071525h · Cited by 23
Sundramoorthy, A. K., & Chen, S. (2006) · Talanta · doi:10.1016/j.talanta.2006.10.038 · Cited by 22
Oxygen tension at the subcutaneous implantation site of glucose sensors.
Fischer, U., Hidde, A., Herrmann, S., von Woedtke, T., Rebrin, K., & Abel, P. (1989) · PubMed · Cited by 22
Implantable flexible electrodes for functional electrical stimulation.
Schneider, A. M., & Stieglitz, T. C. (2004) · PubMed · Cited by 19
Mechanical and biological properties of nanoporous carbon membranes
Narayan, R. J., Aggarwal, R., Wei, W., Jin, C., Monteiro-Riviere, N. A., Crombez, R. C., & Shen, W. C. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034107 · Cited by 19
Methylene‐green‐mediated carbon paste glucose biosensor
Kulys, J. J., Wang, L., Hansen, H. E., Buch‐Rasmussen, T., Wang, J., & Özsöz, M. (1995) · Electroanalysis · doi:10.1002/elan.1140070112 · Cited by 19
Yeh, P. Y., Le, Y., Kizhakkedathu, J. N., & Chiao, M. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9181-8 · Cited by 15
Ishihara, K., Nakabayashi, N., Nishida, K., Sakakida, M., & Shichiri, M. (1994) · ACS symposium series · doi:10.1021/bk-1994-0556.ch016 · Cited by 13
APPLICATION OF POLYANION/Fe3 MULTILAYERED MEMBRANES IN PREVENTION OF BIOSENSOR MINERALIZATION
Galeska, I., Chattopadhyay, D., & Papadimitrakopoulos, F. (2002) · Journal of Macromolecular Science Part A · doi:10.1081/ma-120014846 · Cited by 12
Self-citationFrost, M. C., & Meyerhoff, M. E. (2004) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(04)81045-0 · Cited by 9
Cited by
Zhang, Q., Zhang, K., Xu, D., Yang, G., Huang, H., Nie, F., Liu, C., & Yang, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.09.003 · Cited by 1,404
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Remediation of wastewater using various nano-materials
Anjum, M., Miandad, R., Waqas, M., Gehany, F., & Barakat, M. A. (2019) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2016.10.004 · Cited by 779
Wearable and implantable wireless sensor network solutions for healthcare monitoring
Darwish, A., & Hassanien, A. E. (2011) · Sensors · doi:10.3390/s110605561 · Cited by 556
Metadata
- Authors
- Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 25
- Issue
- 7
- Pages
- 1553-1565
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1969066286
- Cited by
- 368
- References
- 190
- FWCI
- 20.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.