Opportunities and challenges in the development of exoskeletons for locomotor assistance
Open accessThe DOI matches its Crossref record; 243 of the 243 references it cites were found in a registry or an index.
Abstract
Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology. This Review highlights technological advances in exoskeleton technology from the past two decades, and challenges and opportunities in the exoskeleton-assisted rehabilitation of gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Winstein, C. J., Stein, J., Arena, R., Bates, B., Cherney, L. R., Cramer, S. C., Deruyter, F., Eng, J. J., Fisher, B., Harvey, R. L., et al. (2016) · Stroke · doi:10.1161/str.0000000000000098 · Cited by 3,293
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777
Physical fitness training for stroke patients
Saunders, D. H., Sanderson, M., Hayes, S., Kilrane, M., Greig, C. A., Brazzelli, M., & Mead, G. E. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003316.pub6 · Cited by 759
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652
Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
Self-citationThe Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Werner, C., Kugler, J., Pohl, M., & Elsner, B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub4 · Cited by 564
Locomotor adaptation on a split-belt treadmill can improve walking symmetry post-stroke
Reisman, D. S., Wityk, R., Silver, K., & Bastian, A. J. (2007) · Brain · doi:10.1093/brain/awm035 · Cited by 544
Hornby, T. G., Campbell, D. D., Kahn, J. H., Demott, T., Moore, J. L., & Roth, H. R. (2008) · Stroke · doi:10.1161/strokeaha.107.504779 · Cited by 541
Macko, R. F., Ivey, F. M., Forrester, L. W., Hanley, D., Sorkin, J. D., Katzel, L. I., Silver, K. H., & Goldberg, A. P. (2005) · Stroke · doi:10.1161/01.str.0000181076.91805.89 · Cited by 524
The Role of Variability in Motor Learning
Dhawale, A. K., Smith, M. A., & Ölveczky, B. P. (2017) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-072116-031548 · Cited by 516
Reducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
Self-citationIntention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
Strain-programmable fiber-based artificial muscle
Kanik, M., Orguc, S., Varnavides, G., Kim, J., Benavides, T., Gonzalez, D., Akintilo, T., Tasan, C. C., Chandrakasan, A. P., Fink, Y., et al. (2019) · Science · doi:10.1126/science.aaw2502 · Cited by 468
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Husemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Hornby, T. G., Reisman, D. S., Ward, I. G., Scheets, P. L., Miller, A., Haddad, D., Fox, E. J., Fritz, N. E., Hawkins, K., Henderson, C. E., et al. (2020) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0000000000000303 · Cited by 383
Design and Control of the MINDWALKER Exoskeleton
Wang, S., Wang, L., Meijneke, C., van Asseldonk, E., Hoellinger, T., Cheron, G., Ivanenko, Y., La Scaleia, V., Sylos-Labini, F., Molinari, M., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2365697 · Cited by 380
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Self-citationA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
Self-citationPowered robotic exoskeletons in post-stroke rehabilitation of gait: a scoping review
Louie, D. R., & Eng, J. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0162-5 · Cited by 350
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Mulroy, S., Gronley, J., Weiss, W., Newsam, C., & Perry, J. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00165-0 · Cited by 339
Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation
Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., & Hogan, N. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019783 · Cited by 337
Werner, C., von Frankenberg, S., Treig, T., Konrad, M., & Hesse, S. (2002) · Stroke · doi:10.1161/01.str.0000035734.61539.f6 · Cited by 328
Personalizing exoskeleton assistance while walking in the real world
Slade, P., Kochenderfer, M. J., Delp, S. L., & Collins, S. H. (2022) · Nature · doi:10.1038/s41586-022-05191-1 · Cited by 328
Physical fitness training for stroke patients
Saunders, D. H., Sanderson, M., Hayes, S., Johnson, L., Kramer, S., Carter, D., Jarvis, H., Brazzelli, M., & Mead, G. E. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003316.pub7 · Cited by 321
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
Automatic Gait-Pattern Adaptation Algorithms for Rehabilitation With a 4-DOF Robotic Orthosis
Jezernik, S., Colombo, G., & Morari, M. (2004) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2004.825515 · Cited by 312
Split-Belt Treadmill Adaptation Transfers to Overground Walking in Persons Poststroke
Reisman, D. S., Wityk, R., Silver, K., & Bastian, A. J. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309332880 · Cited by 301
Mechanics and energetics of level walking with powered ankle exoskeletons
Sawicki, G. S., & Ferris, D. P. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.009241 · Cited by 297
Morone, G., Paolucci, S., Cherubini, A., De Angelis, D., Venturiero, V., Coiro, P., & Iosa, M. (2017) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s114102 · Cited by 297
The Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Self-citationRepeated Split-Belt Treadmill Training Improves Poststroke Step Length Asymmetry
Reisman, D. S., McLean, H., Keller, J., Danks, K. A., & Bastian, A. J. (2013) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968312474118 · Cited by 281
Kermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Towards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 259
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
Self-citationEEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
Mannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
The rise of the body bots [robotic exoskeletons
Guizzo, E., & Goldstein, H. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1515961 · Cited by 238
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Mooney, L. M., & Herr, H. M. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0111-3 · Cited by 229
The development and testing of a human machine interface for a mobile medical exoskeleton
Strausser, K. A., & Kazerooni, H. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6095025 · Cited by 226
Galle, S., Malcolm, P., Collins, S. H., & De Clercq, D. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0235-0 · Cited by 225
Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Mechanical performance of artificial pneumatic muscles to power an ankle–foot orthosis
Gordon, K. E., Sawicki, G. S., & Ferris, D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.018 · Cited by 223
Dobkin, B. H., & Duncan, P. W. (2012) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968312439687 · Cited by 221
Development of a lightweight, underactuated exoskeleton for load-carrying augmentation
Walsh, C. J., Paluska, D., Pasch, K., Grand, W., Valiente, A., & Herr, H. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642234 · Cited by 220
Self-citationPerformance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
Progressive Staging of Pilot Studies to Improve Phase III Trials for Motor Interventions
Dobkin, B. H. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309331863 · Cited by 219
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
Self-citationNilsson, A., Vreede, K., Häglund, V., Kawamoto, H., Sankai, Y., & Borg, J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-92 · Cited by 206
Jackson, R. W., & Collins, S. H. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01133.2014 · Cited by 205
Peurala, S. H., Tarkka, I. M., Pitkänen, K., & Sivenius, J. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.02.005 · Cited by 204
Locomotor training for walking after spinal cord injury
Mehrholz, J., Kugler, J., & Pohl, M. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006676.pub3 · Cited by 203
Schmidt, K., Duarte, J. E., Grimmer, M., Sancho-Puchades, A., Wei, H., Easthope, C. S., & Riener, R. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00057 · Cited by 202
High accuracy decoding of user intentions using EEG to control a lower-body exoskeleton
Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610821 · Cited by 196
Kozlowski, A., Bryce, T., & Dijkers, M. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-110 · Cited by 193
Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton
del-Ama, A. J., Gil-Agudo, Á., Pons, J. L., & Moreno, J. C. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-27 · Cited by 190
Kolakowsky-Hayner, S. A. (2013) · Journal of Spine · doi:10.4172/2165-7939.s4-003 · Cited by 190
Buesing, C., Fisch, G., O’Donnell, M., Shahidi, I., Thomas, L., Mummidisetty, C. K., Williams, K. J., Takahashi, H., Rymer, W. Z., & Jayaraman, A. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0062-0 · Cited by 187
Electromechanical-Assisted Training for Walking After Stroke: Updated Evidence
Mehrholz, J., Elsner, B., Werner, C., Kugler, J., & Pohl, M. (2013) · Stroke · doi:10.1161/strokeaha.113.003061 · Cited by 187
Lerner, Z. F., Damiano, D. L., & Bulea, T. C. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aam9145 · Cited by 187
Gauging force by tapping tendons
Martin, J. A., Brandon, S. C. E., Keuler, E. M., Hermus, J. R., Ehlers, A. C., Segalman, D. J., Allen, M. S., & Thelen, D. G. (2018) · Nature Communications · doi:10.1038/s41467-018-03797-6 · Cited by 186
Development of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333698 · Cited by 182
Exercise after Stroke: Patient Adherence and Beliefs after Discharge from Rehabilitation
Miller, K. K., Porter, R. E., DeBaun-Sprague, E., Van Puymbroeck, M., & Schmid, A. A. (2017) · Topics in Stroke Rehabilitation · doi:10.1080/10749357.2016.1200292 · Cited by 181
Surface-stimulation technology for grasping and walking neuroprostheses
Popović, M. R., Keller, T., Papas, I., Dietz, V., & Morari, M. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897831 · Cited by 180
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
Fully autonomous hip exoskeleton saves metabolic cost of walking
Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487663 · Cited by 177
Review of hybrid exoskeletons to restore gait following spinal cord injury
del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0043 · Cited by 174
Risk management and regulations for lower limb medical exoskeletons: a review
He, Y., Eguren, D., Luu, T. P., & Contreras-Vidal, J. L. (2017) · Medical Devices Evidence and Research · doi:10.2147/mder.s107134 · Cited by 174
Advanced Neurotechnologies for the Restoration of Motor Function
Micera, S., Caleo, M., Chisari, C., Hummel, F. C., & Pedrocchi, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.01.039 · Cited by 171
Lajeunesse, V., Vincent, C., Routhier, F., Careau, E., & Michaud, F. (2016) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2015.1080766 · Cited by 170
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Dembia, C. L., Silder, A., Uchida, T. K., Hicks, J. L., & Delp, S. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0180320 · Cited by 170
Real-Time Neural Network-Based Gait Phase Estimation Using a Robotic Hip Exoskeleton
Kang, I., Kunapuli, P., & Young, A. J. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2961749 · Cited by 168
A neuromechanics-based powered ankle exoskeleton to assist walking post-stroke: a feasibility study
Takahashi, K. Z., Lewek, M. D., & Sawicki, G. S. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0015-7 · Cited by 166
Filli, L., Sutter, T., Easthope, C. A., Killeen, T., Meyer, C., Reuter, K., Lőrincz, L., Bolliger, M., Weller, M., Curt, A. E. P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22676-0 · Cited by 166
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Self-citationTefertiller, C., Hays, K., Jones, J., Jayaraman, A., Hartigan, C., Bushnik, T., & Forrest, G. F. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci17-00014 · Cited by 165
Lerner, Z. F., Damiano, D. L., Park, H., Gravunder, A. J., & Bulea, T. C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2595501 · Cited by 164
Simulating Ideal Assistive Devices to Reduce the Metabolic Cost of Running
Uchida, T. K., Seth, A., Pouya, S., Dembia, C. L., Hicks, J. L., & Delp, S. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163417 · Cited by 164
An autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Self-citationKoller, J. R., Jacobs, D. A., Ferris, D. P., & Remy, C. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0086-5 · Cited by 162
Real-Time Gait Phase Estimation for Robotic Hip Exoskeleton Control During Multimodal Locomotion
Kang, I., Molinaro, D. D., Duggal, S., Chen, Y., Kunapuli, P., & Young, A. J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3062562 · Cited by 162
An Efficient Robotic Tendon for Gait Assistance
Hollander, K. W., Ilg, R., Sugar, T. G., & Herring, D. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264391 · Cited by 161
A Universal Ankle–Foot Prosthesis Emulator for Human Locomotion Experiments
Caputo, J. M., & Collins, S. H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026225 · Cited by 161
Awad, L. N., Esquenazi, A., Francisco, G. E., Nolan, K. J., & Jayaraman, A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00702-5 · Cited by 161
Self-citationGregorczyk, K. N., Hasselquist, L., Schiffman, J. M., Bensel, C. K., Obusek, J. P., & Gutekunst, D. J. (2010) · Ergonomics · doi:10.1080/00140139.2010.512982 · Cited by 160
Stretching Your Energetic Budget: How Tendon Compliance Affects the Metabolic Cost of Running
Uchida, T. K., Hicks, J. L., Dembia, C. L., & Delp, S. L. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150378 · Cited by 158
A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients
Kwon, J., Park, J.-H., Ku, S., Jeong, Y., Paik, N.-J., & Park, Y.-L. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2908491 · Cited by 158
A passive exoskeleton with artificial tendons: Design and experimental evaluation
van Dijk, W., van der Kooij, H., & Hekman, E. E. G. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975470 · Cited by 156
Reducing the Energy Cost of Human Running Using an Unpowered Exoskeleton
Nasiri, R., Ahmadi, A., & Ahmadabadi, M. N. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2872889 · Cited by 155
Robotic Measurement of Arm Movements After Stroke Establishes Biomarkers of Motor Recovery
Krebs, H. I., Krams, M., Agrafiotis, D. K., DiBernardo, A., Chavez, J. C., Littman, G. S., Yang, E., Byttebier, G., Dipietro, L., Rykman, A., et al. (2014) · Stroke · doi:10.1161/strokeaha.113.002296 · Cited by 154
Yeung, L.-F., Ockenfeld, C., Pang, M., Wai, H., Soo, O.-Y., Li, S.-W., & Tong, R. K. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0394-7 · Cited by 152
Lee, H.-J., Lee, S., Chang, W. H., Seo, K., Shim, Y., Choi, B., Ryu, G.-H., & Kim, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2664801 · Cited by 150
Design of two lightweight, high-bandwidth torque-controlled ankle exoskeletons
Witte, K. A., Zhang, J., Jackson, R. W., & Collins, S. H. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139347 · Cited by 149
Autonomous exoskeleton reduces metabolic cost of human walking
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-151 · Cited by 145
Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., et al. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8461046 · Cited by 145
Self-citationReducing the metabolic cost of running with a tethered soft exosuit
Lee, G., Kim, J., Panizzolo, F. A., Zhou, Y. M., Baker, L. M., Galiana, I., Malcolm, P., & Walsh, C. J. (2017) · Science Robotics · doi:10.1126/scirobotics.aan6708 · Cited by 143
Self-citationWatanabe, H., Tanaka, N., Inuta, T., Saitou, H., & Yanagi, H. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.07.002 · Cited by 142
Emken, J. L., Bobrow, J. E., & Reinkensmeyer, D. J. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501108 · Cited by 142
Emken, J. L., Harkema, S. J., Beres-Jones, J. A., Ferreira, C. K., & Reinkensmeyer, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910683 · Cited by 141
Effects of intensive therapy using gait trainer or floor walking exercises early after stroke
Peurala, S., Airaksinen, O., Huuskonen, P., Jäkälä, P., Juhakoski, M., Sandell, K., Tarkka, I., & Sivenius, J. (2009) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0304 · Cited by 141
Yandell, M. B., Tacca, J. R., & Zelik, K. E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2904924 · Cited by 138
A lightweight, low-power electroadhesive clutch and spring for exoskeleton actuation
Diller, S., Majidi, C., & Collins, S. H. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487194 · Cited by 137
Seel, T., Schauer, T., & Raisch, J. (2012) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2012.6402423 · Cited by 132
Functional electrical stimulation of walking: Function, exercise and rehabilitation
Thrasher, T. A., & Popović, M. R. (2008) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2008.05.006 · Cited by 130
Kressler, J., Thomas, C. K., Field-Fote, E. C., Sanchez, J. C., Widerström-Noga, E. G., Cilien, D. C., Gant, K. L., Ginnety, K., González, H. F. J., Martínez, A., et al. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.04.026 · Cited by 130
Channa, A., Popescu, N., & Ciobanu, V. (2020) · Sensors · doi:10.3390/s20092713 · Cited by 130
The role of series ankle elasticity in bipedal walking
Zelik, K. E., Huang, T.-W. P., Adamczyk, P. G., & Kuo, A. D. (2013) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2013.12.014 · Cited by 128
Bang, D.-H., & Shin, W.-S. (2016) · Neurorehabilitation · doi:10.3233/nre-161325 · Cited by 127
The Cybathlon promotes the development of assistive technology for people with physical disabilities
Riener, R. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0157-2 · Cited by 127
A Rehabilitation-Internet-of-Things in the Home to Augment Motor Skills and Exercise Training
Dobkin, B. H. (2017) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968316680490 · Cited by 127
The role of user preference in the customized control of robotic exoskeletons
Ingraham, K. A., Remy, C. D., & Rouse, E. J. (2022) · Science Robotics · doi:10.1126/scirobotics.abj3487 · Cited by 126
Lv, G., Zhu, H., & Gregg, R. D. (2018) · IEEE Control Systems · doi:10.1109/mcs.2018.2866605 · Cited by 124
Taveggia, G., Borboni, A., Mulè, C., Villafañe, J. H., & Négrini, S. (2015) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0000000000000137 · Cited by 120
Automated detection of gait initiation and termination using wearable sensors
Novak, D., Reberšek, P., De Rossi, S. M. M., Donati, M., Podobnik, J., Beravs, T., Lenzi, T., Vitiello, N., Carrozza, M. C., & Munih, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.07.003 · Cited by 116
Gandolfi, M., Geroin, C., Picelli, A., Munari, D., Waldner, A., Tamburin, S., Marchioretto, F., & Smania, N. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00318 · Cited by 116
'Body-in-the-Loop' Optimization of Assistive Robotic Devices: A Validation Study
Koller, J. R., Gates, D. H., Ferris, D. P., & Remy, C. D. (2016) · Robotics: Science and Systems · doi:10.15607/rss.2016.xii.007 · Cited by 115
Design and Evaluation of a Soft Assistive Lower Limb Exoskeleton
Natali, C. D., Poliero, T., Sposito, M., Graf, E. S., Bauer, C. M., Pauli, C. A., Bottenberg, E., de Eyto, A., O'Sullivan, L. W., Hidalgo, A. F., et al. (2019) · Robotica · doi:10.1017/s0263574719000067 · Cited by 115
A hip–knee–ankle exoskeleton emulator for studying gait assistance
Bryan, G. M., Franks, P., Klein, S. C., Peuchen, R. J., & Collins, S. (2020) · Int. J. Robotics Res. · doi:10.1177/0278364920961452 · Cited by 113
Multi-joint actuation platform for lower extremity soft exosuits
Ding, Y., Galiana, I., Asbeck, A., Quinlivan, B., De Rossi, S. M. M., & Walsh, C. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907024 · Cited by 112
Self-citationGait training using a robotic hip exoskeleton improves metabolic gait efficiency in the elderly
Martini, E., Crea, S., Parri, A., Bastiani, L., Faraguna, U., McKinney, Z., Molino-Lova, R., Pratali, L., & Vitiello, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-43628-2 · Cited by 108
The Body Extender: A Full-Body Exoskeleton for the Transport and Handling of Heavy Loads
Fontana, M., Vertechy, R., Marcheschi, S., Salsedo, F., & Bergamasco, M. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360287 · Cited by 106
Stride management assist exoskeleton vs functional gait training in stroke: A randomized trial
Jayaraman, A., O’Brien, M. K., Madhavan, S., Mummidisetty, C. K., Roth, H., Hohl, K., Tapp, A., Brennan, K., Kocherginsky, M., Williams, K. J., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000006782 · Cited by 105
Orthopedic Rehabilitation Using the “Rutgers Ankle” Interface
Girone, M., Burdea, G., Bouzit, M., Popescu, V., & Deutsch, J. E. (2000) · Studies in health technology and informatics · doi:10.3233/978-1-60750-914-1-89 · Cited by 105
McCain, E. M., Dick, T. J. M., Giest, T. N., Nuckols, R. W., Lewek, M. D., Saul, K. R., & Sawicki, G. S. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0523-y · Cited by 103
Controlling negative and positive power at the ankle with a soft exosuit
Lee, S., Crea, S., Malcolm, P., Galiana, I., Asbeck, A. T., & Walsh, C. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487531 · Cited by 102
Self-citationJonsdottir, J., Cattaneo, D., Recalcati, M., Regola, A., Rabuffetti, M., Ferrarin, M., & Casiraghi, A. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309355986 · Cited by 100
A soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit
Bae, J., Maria De Rossi, S. M., O'Donnell, K., Hendron, K. L., Awad, L. N., Teles Dos Santos, T. R., De Araujo, V. L., Ding, Y., Holt, K. G., Ellis, T. D., et al. (2015) · 2015 IEEE International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2015.7281188 · Cited by 99
Self-citationDurandau, G., Rampeltshammer, W. F., van der Kooij, H., & Sartori, M. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3170239 · Cited by 98
Design and Control of a Lower Limb Exoskeleton for Robot-Assisted Gait Training
Beyl, P., Damme, M. V., Ham, R. V., Vanderborght, B., & Lefeber, D. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902784393 · Cited by 97
Torricelli, D., Rodriguez‐Guerrero, C., Veneman, J. F., Crea, S., Briem, K., Lenggenhager, B., & Beckerle, P. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.561774 · Cited by 96
Wearable Sensors to Monitor, Enable Feedback, and Measure Outcomes of Activity and Practice
Dobkin, B. H., & Martinez, C. A. (2018) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-018-0896-5 · Cited by 94
Reducing the energy cost of walking in older adults using a passive hip flexion device
Panizzolo, F. A., Bolgiani, C., Liddo, L. D., Annese, E., & Marcolin, G. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0599-4 · Cited by 93
Lee, S., Lee, H.-J., Chang, W. H., Choi, B., Lee, J., Kim, J., Ryu, G.-H., & Kim, Y. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0333-z · Cited by 92
Orekhov, G., Fang, Y., Cuddeback, C. F., & Lerner, Z. F. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00954-9 · Cited by 92
Efficacy of a hybrid assistive limb in post-stroke hemiplegic patients: a preliminary report
Maeshima, S., Osawa, A., Nishio, D., Hirano, Y., Takeda, K., Kigawa, H., & Sankai, Y. (2011) · BMC Neurology · doi:10.1186/1471-2377-11-116 · Cited by 90
Autonomous hip exoskeleton saves metabolic cost of walking uphill
Seo, K., Lee, J., & Park, Y. J. (2017) · 2017 International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2017.8009254 · Cited by 90
The effects of electroadhesive clutch design parameters on performance characteristics
Diller, S., Collins, S. H., & Majidi, C. (2018) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x18799474 · Cited by 90
Siviy, C., Bae, J., Baker, L. M., Porciuncula, F., Baker, T. C., Ellis, T. D., Awad, L. N., & Walsh, C. J. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2965072 · Cited by 90
Self-citationNuckols, R. W., Dick, T. J. M., Beck, O. N., & Sawicki, G. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-60360-4 · Cited by 90
Molinaro, D. D., Kang, I., Camargo, J., Gombolay, M. C., & Young, A. J. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3144025 · Cited by 90
Khazoom, C., Veronneau, C., Bigué, J.-P. L., Grenier, J., Girard, A., & Plante, J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2924852 · Cited by 89
Quintero, D., Villarreal, D. J., & Gregg, R. D. (2016) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2016.7759798 · Cited by 87
Real-Time Strap Pressure Sensor System for Powered Exoskeletons
Tamez-Duque, J., Cobian-Ugalde, R., Kilicarslan, A., Venkatakrishnan, A., Soto, R., & Contreras-Vidal, J. L. (2015) · Sensors · doi:10.3390/s150204550 · Cited by 83
Laidig, D., Schauer, T., & Seel, T. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009375 · Cited by 83
Farris, D. J., Hicks, J. L., Delp, S. L., & Sawicki, G. S. (2014) · Journal of Experimental Biology · doi:10.1242/jeb.107656 · Cited by 81
Awad, L. N., Bae, J., Kudzia, P., Long, A., Hendron, K. L., Holt, K. G., O’Donnell, K., Ellis, T. D., & Walsh, C. J. (2017) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000800 · Cited by 81
Self-citationLeroux, A. (2005) · International Journal of Rehabilitation Research · doi:10.1097/00004356-200503000-00003 · Cited by 80
Sale, P., Russo, E. F., Russo, M., Masiero, S., Piccione, F., Calabrò, R. S., & Filoni, S. (2016) · BMC Neurology · doi:10.1186/s12883-016-0536-0 · Cited by 79
Ochi, M., Wada, F., Saeki, S., & Hachisuka, K. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.04.033 · Cited by 77
Khan, A. S., Livingstone, D., Hurd, C., Duchcherer, J., Misiaszek, J. E., Gorassini, M. A., Manns, P. J., & Yang, J. F. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0585-x · Cited by 75
Ferrante, S., Ambrosini, E., Ravelli, P., Guanziroli, E., Molteni, F., Ferrigno, G., & Pedrocchi, A. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-47 · Cited by 73
Esquenazi, A., Lee, S., Packel, A. T., & Braitman, L. E. (2012) · PM&R · doi:10.1016/j.pmrj.2012.10.009 · Cited by 72
Gait Adaptation Using a Cable-Driven Active Leg Exoskeleton (C-ALEX) With Post-Stroke Participants
Hidayah, R., Bishop, L., Jin, X. H., Chamarthy, S., Stein, J. M., & Agrawal, S. K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3009317 · Cited by 71
Boehler, A., Hollander, K. W., Sugar, T. G., & Shin, D. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543504 · Cited by 70
Gait Training with a Robotic Leg Brace After Stroke: A Randomized Controlled Pilot Study
Stein, J. M., Bishop, L., Stein, D. J., & Wong, C. K. (2014) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000119 · Cited by 69
Grimmer, M., Quinlivan, B., Lee, S., Malcolm, P., Rossi, D. M., Siviy, C., & Walsh, C. J. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.023 · Cited by 69
Self-citationEnhancing Voluntary Motion With Modular, Backdrivable, Powered Hip and Knee Orthoses
Nesler, C., Thomas, G. C., Divekar, N., Rouse, E. J., & Gregg, R. D. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3145580 · Cited by 69
A new adaptive frequency oscillator for gait assistance
Seo, K., Hyung, S., Choi, B. K., Lee, Y., & Shim, Y. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139977 · Cited by 68
Lee, J., Seo, K., Lim, B., Jang, J., Kim, K., & Choi, H. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009297 · Cited by 68
Hitt, J. K., Oymagil, A. M., Sugar, T. G., Hollander, K. W., Boehler, A., & Fleeger, J. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363543 · Cited by 67
Kim, J., Heimgartner, R., Lee, G., Karavas, N. C., Perry, D., Ryan, D. L., Eckert-Erdheim, A. M., Murphy, P., Choe, D. K., Galiana, I., et al. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460474 · Cited by 67
Self-citationÁrmannsdóttir, A. L., Beckerle, P., Moreno, J. C., van Asseldonk, E. H. F., Manrique-Sancho, M.-T., del‐Ama, A. J., Veneman, J. F., & Briem, K. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819883500 · Cited by 67
Brain-controlled exoskeleton robot for BMI rehabilitation
Noda, T., Sugimoto, N., Furukawa, J.-I., Sato, M., Hyon, S.-H., & Morimoto, J. (2012) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2012.6651494 · Cited by 66
Dissociating motor learning from recovery in exoskeleton training post-stroke
Schweighofer, N., Wang, C., Mottet, D., Laffont, I., Bakhti, K., Reinkensmeyer, D. J., & Rémy‐Néris, O. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0428-1 · Cited by 66
Nuckols, R. W., & Sawicki, G. S. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00703-4 · Cited by 66
Limit Cycles to Enhance Human Performance Based on Phase Oscillators
Sugar, T. G., Bates, A. R., Holgate, M. A., Kerestes, J., Mignolet, M. P., New, P., Ramachandran, R. K., Redkar, S., & Wheeler, C. (2014) · Journal of Mechanisms and Robotics · doi:10.1115/1.4029336 · Cited by 65
Deep Learning Enables Exoboot Control to Augment Variable-Speed Walking
Shepherd, M. K., Molinaro, D. D., Sawicki, G. S., & Young, A. J. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3147565 · Cited by 64
Evidence for a Time-Invariant Phase Variable in Human Ankle Control
Gregg, R. D., Rouse, E. J., Hargrove, L. J., & Sensinger, J. W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089163 · Cited by 61
Varying negative work assistance at the ankle with a soft exosuit during loaded walking
Malcolm, P., Lee, S., Crea, S., Siviy, C., Saucedo, F., Galiana, I., Panizzolo, F. A., Holt, K. G., & Walsh, C. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0267-5 · Cited by 61
Self-citationAccelerating locomotor savings in learning: compressing four training days to one
Day, K. A., Leech, K. A., Roemmich, R. T., & Bastian, A. J. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00903.2017 · Cited by 61
Soft Sensing Shirt for Shoulder Kinematics Estimation
Jin, Y., Glover, C., Cho, H., Araromi, O. A., Graule, M. A., Li, N., Wood, R. J., & Walsh, C. J. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9196586 · Cited by 61
Self-citationShimada, H., Suzuki, T., Kimura, Y., Hirata, T., Sugiura, M., Endo, Y., Yasuhara, K., Shimada, K., Kikuchi, K., Oda, K., et al. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.039453 · Cited by 59
Can humans perceive the metabolic benefit provided by augmentative exoskeletons?
Medrano, R. L., Thomas, G. C., & Rouse, E. J. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01002-w · Cited by 59
Cited by
Wang, H., Ding, Q., Luo, Y., Wu, Z., Yu, J., Chen, H., Zhou, Y., Zhang, H., Tao, K., Chen, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202309868 · Cited by 290
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Self-citationWearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 173
Experiment-free exoskeleton assistance via learning in simulation
Luo, S., Jiang, M., Zhang, S., Zhu, J., Yu, S., Dominguez Silva, I., Wang, T., Rouse, E., Zhou, B., Yuk, H., et al. (2024) · Nature · doi:10.1038/s41586-024-07382-4 · Cited by 166
Metadata
- Authors
- Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J.
- Venue
- Nature Biomedical Engineering
- Published
- 2022-12-22
- Volume
- 7
- Issue
- 4
- Pages
- 456-472
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4312115223
- Cited by
- 258
- References
- 243
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.