Acoustically detectable cellular-level lung injury induced by fluid mechanical stresses in microfluidic airway systems
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We describe a microfabricated airway system integrated with computerized air–liquid two-phase microfluidics that enables on-chip engineering of human airway epithelia and precise reproduction of physiologic or pathologic liquid plug flows found in the respiratory system. Using this device, we demonstrate cellular-level lung injury under flow conditions that cause symptoms characteristic of a wide range of pulmonary diseases. Specifically, propagation and rupture of liquid plugs that simulate surfactant-deficient reopening of closed airways lead to significant injury of small airway epithelial cells by generating deleterious fluid mechanical stresses. We also show that the explosive pressure waves produced by plug rupture enable detection of the mechanical cellular injury as crackling sounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Small-Airway Obstruction in Chronic Obstructive Pulmonary Disease
Hogg, J. C., Chu, F., Utokaparch, S., Woods, R., Elliott, W. M., Buzatu, L., Cherniack, R. M., Rogers, R. M., Sciurba, F. C., Coxson, H. O., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032158 · Cited by 3,782
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Tidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Respiratory Sounds: Advances Beyond the Stethoscope
PASTERKAMP, H., KRAMAN, S. S., & WODICKA, G. R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.3.9701115 · Cited by 634
Calcium Mobilization and Exocytosis After One Mechanical Stretch of Lung Epithelial Cells
Wirtz, H. R. W., & Dobbs, L. G. (1990) · Science · doi:10.1126/science.2173861 · Cited by 511
Weibel, E. R., & Gomez, D. M. (1962) · Science · doi:10.1126/science.137.3530.577 · Cited by 470
You, Y., Richer, E. J., Huang, T., & Brody, S. L. (2002) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00169.2002 · Cited by 442
Günther, A., Siebert, C., Schmidt, R., Ziegler, S., Grimminger, F., Yabut, M., Temmesfeld, B., Walmrath, D., Morr, H., & Seeger, W. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.1.8542113 · Cited by 417
Stretch induces cytokine release by alveolar epithelial cells in vitro
Vlahakis, N. E., Schroeder, M. A., Limper, A. H., & Hubmayr, R. D. (1999) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1999.277.1.l167 · Cited by 389
Bilek, A. M., Dee, K. C., & Gaver, D. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00764.2002 · Cited by 354
Cited by
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
“…microfluidic channel and integrated with a computer-controlled, two-phase (air – liquid) microfluidic switching system to mimic the propagation and rupture of liquid plugs that occur during the reopening of collapsed airways that causes mechanical airway injury in obstructive pulmonary disease [69].”
MethodSelf-citationHuman organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationZhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
A decade of progress in tissue engineering
Khademhosseini, A., & Langer, R. (2016) · Nature Protocols · doi:10.1038/nprot.2016.123 · Cited by 747
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Self-citationFundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“Lung-on-a-chip devices have been under development for about a decade [39].”
BackgroundA multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
A lung-on-a-chip array with an integrated bio-inspired respiration mechanism
Stucki, A. O., Stucki, J. D., Hall, S. R. R., Felder, M., Mermoud, Y., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c4lc01252f · Cited by 410
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
“Certain enhancements have been made to single cell culture models, such as microfluidics and flexible membranes to apply fluid and solid mechanical stresses to single cell alveolar models to simulate the effects of mechanical ventilation and physiologic or pathologic liquid plug flows [80-82].”
BackgroundAdvances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
Microfluidic system for formation of PC-3 prostate cancer co-culture spheroids
Hsiao, A. Y., Torisawa, Y.-S., Tung, Y.-C., Sud, S., Taichman, R. S., Pienta, K. J., & Takayama, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.047 · Cited by 323
“Since we have previously demonstrated that cells can be cultured normally inside a membrane-type device [34,41], the”
Self-citationMicrofluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
“The microfluidic device (Figure 1A) consisted of two channel layers of 12:1 base to curing agent poly(dimethylsiloxane) (PDMS, Sylgard 184, Dow Corning) that sandwiched a semi-porous, optically clear polyester membrane [41].”
MethodSelf-citationOrgans-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Bio-inspired intelligent structural color materials
Shang, L., Zhang, W., Xu, K., & Zhao, Y. (2019) · Materials Horizons · doi:10.1039/c9mh00101h · Cited by 301
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“Finally, vascular MPS are used as models for arterial thrombosis (Huh et al., 2007; Westein et al., 2013).”
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Smith, A. M., & Dragunow, M. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2013.12.001 · Cited by 256
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
Self-citationOrgans-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Douville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Lab Chip · doi:10.1039/c0lc00251h · Cited by 216
Self-citationUse of precision cut lung slices as a translational model for the study of lung biology
Liu, G., Betts, C., Cunoosamy, D. M., Åberg, P. M., Hornberg, J. J., Sivars, K. B., & Cohen, T. S. (2019) · Respiratory Research · doi:10.1186/s12931-019-1131-x · Cited by 206
Humayun, M., Chow, C.-W., & Young, E. W. K. (2018) · Lab on a Chip · doi:10.1039/c7lc01357d · Cited by 206
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Jang, K.-J., Cho, H. S., Kang, D. H., Bae, W. G., Kwon, T.-H., & Suh, K.-Y. (2011) · Integr. Biol. · doi:10.1039/c0ib00018c · Cited by 177
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“One application has used a design in which a two-phase microfluidic system mimics the physiological and pathophysiological effects associated with pulmonary airways [371].”
MethodChang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
Self-citationFlow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Self-citationAn On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
In vitro metabolic zonation through oxygen gradient on a chip
Tonon, F., Giobbe, G. G., Zambon, A., Luni, C., Gagliano, O., Floreani, A., Grassi, G., & Elvassore, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-49412-6 · Cited by 76
A 3D toolbox to enhance physiological relevance of human tissue models
Picollet-D’hahan, N., Dolega, M. E., Liguori, L., Marquette, C., Le Gac, S., Gidrol, X., & Martin, D. K. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.06.012 · Cited by 65
Biomimetic channel modeling local vascular dynamics of pro-inflammatory endothelial changes
Thomas, A., Daniel Ou-Yang, H., Lowe-Krentz, L., Muzykantov, V. R., & Liu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4936672 · Cited by 46
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
“Huh et al., 2007 [79]described an in vitro model of the human small airway to reproduce under flow conditions cellular level lung injury, which causes symptoms that are characteristic of 75 some pulmonary diseases [Fig.”
BackgroundEngineering cell heterogeneity into organs-on-a-chip
Mertz, D. R., Ahmed, T., & Takayama, S. (2018) · Lab on a Chip · doi:10.1039/c8lc00413g · Cited by 33
Self-citation
Metadata
- Authors
- Huh, D., Fujioka, H., Tung, Y.-C., Futai, N., Paine, R., Grotberg, J. B., & Takayama, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-11-27
- Volume
- 104
- Issue
- 48
- Pages
- 18886-18891
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2056071500
- Cited by
- 492
- References
- 40
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.