Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves
The DOI matches its Crossref record; 77 of the 78 references it cites were found in a registry or an index.
Abstract
Objective An important goal of neuroprosthetic research is to establish bidirectional communication between the user and new prosthetic limbs that are capable of controlling >20 different movements. One strategy for achieving this goal is to interface the prosthetic limb directly with efferent and afferent fibres in the peripheral nervous system using an array of intrafascicular microelectrodes. This approach would provide access to a large number of independent neural pathways for controlling high degree-of-freedom prosthetic limbs, as well as evoking multiple-complex sensory percepts. Approach Utah Slanted Electrode Arrays (USEAs, 96 recording/stimulating electrodes) were implanted for 30 days into the median (Subject 1-M, 31 years post-amputation) or ulnar (Subject 2-U, 1.5 years post-amputation) nerves of two amputees. Neural activity was recorded during intended movements of the subject's phantom fingers and a linear Kalman filter was used to decode the neural data. Microelectrode stimulation of varying amplitudes and frequencies was delivered via single or multiple electrodes to investigate the number, size and quality of sensory percepts that could be evoked. Device performance over time was assessed by measuring: electrode impedances, signal-to-noise ratios (SNRs), stimulation thresholds, number and stability of evoked percepts. Main results The subjects were able to proportionally, control individual fingers of a virtual robotic hand, with 13 different movements deco…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Instead, electrical stimulation has shown promise in providing tactile feedback through stimulation of afferent sensory axons (3, 5–7).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [3]
In the citing paper
“Electrodes placed within a peripheral nerve can record distinct efferent motor action potentials but over time are susceptible to decline in signal amplitude (3, 4).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [3]
In the citing paper
“Nonetheless, P3 and P4’s SNRs were substantially larger for RPNIs with implanted bipolar electrodes than measured SNR in nerve cuff electrodes or intraneural probes, whose SNR ranges from 4 to 15 (3, 9, 21, 22).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [3]
In the citing paper
“Very recently, Davis et al implanted USEAs in the median and ulnar nerves of two human subjects with amputated arms. The subjects were able to proportionally control individual fingers of a virtual robotic hand, with as much as 13 different movements after offline decoding and two movements after online decoding (Davis et al., 2016).”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Davis et al., 2016
In the citing paper
“In addition, stimulation of the individual electrodes evoked multiple percepts that were spatially distributed across the phantom hands in anatomically appropriate distributions.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Davis et al., 2016
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“for Subject 2-U, and we hypothesize this may be due to the stabilization in the surrounding tissue as the acute inflammatory response begins to resolve [69].”
BackgroundNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“to record neural signals that can be used to control external devices, suggesting the viability of this type of interface for longer duration implant times [10].”
BackgroundNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Merzenich, M. M., Kaas, J. H., Wall, J., Nelson, R. J., Sur, M., & Felleman, D. (1983) · Neuroscience · doi:10.1016/0306-4522(83)90024-6 · Cited by 1,042
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 3×
“Electrophysiological recordings from, and electrical stimulation of, peripheral nerves using transversal multichannel intrafascicular electrodes have enable human subjects to make three different grasp movements utilizing sensory feedback provided by sensors in a prosthetic hand [43, 44].”
BackgroundA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 6×
“Recent studies have shown modulation of stimulation intensity with a time-variant pulse width results in more natural evoked perceptions [45] and employing these methods may improve the quality of percepts produced by microelectrodes.”
BackgroundMethodInfluentialMerzenich, M. M., Kaas, J. H., Wall, J. T., Sur, M., Nelson, R. J., & Felleman, D. J. (1983) · Neuroscience · doi:10.1016/0306-4522(83)90208-7 · Cited by 735
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“Maximum stimulation was limited by either: (1) the comfort level of the subject, (2) a perceived change in the quality of the percept or (3) if the maximum safety limit for delivering electricity to tissue was reached [64].”
BackgroundCognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Self-citationKaas, J. H., Merzenich, M. M., & Killackey, H. P. (1983) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.06.030183.001545 · Cited by 661
Decoding motor imagery from the posterior parietal cortex of a tetraplegic human
Aflalo, T., Kellis, S., Klaes, C., Lee, B., Shi, Y., Pejsa, K., Shanfield, K., Hayes-Jackson, S., Aisen, M., Heck, C., et al. (2015) · Science · doi:10.1126/science.aaa5417 · Cited by 649
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Decoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
How Somatotopic Is the Motor Cortex Hand Area?
Schieber, M. H., & Hibbard, L. S. (1993) · Science · doi:10.1126/science.8332915 · Cited by 464
Bayesian Population Decoding of Motor Cortical Activity Using a Kalman Filter
Wu, W., Gao, Y., Bienenstock, E., Donoghue, J. P., & Black, M. J. (2006) · Neural Computation · doi:10.1162/089976606774841585 · Cited by 456
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 7×
“limbs using an array of 96 microelectrodes, the Utah Slanted Electrode Array (USEA) [52], which increases the number of electrodes that have been used to interface with a peripheral nerve by 80 more electrodes per nerve over previously investigated neural interfaces [44, 45].”
BackgroundMethodInfluentialSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 11×
“Furthermore, impedances may stabilize after 30 days as shown in previous studies of USEAs implanted in the feline sciatic nerve [70].”
MethodInfluentialSelf-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“with control of up to three different movements from offline decodes [37, 43, 44], and sensory feedback has been provided via electrical stimulation [37, 38, 40, 44, 45, 49, 56, 57] with”
Self-citationClinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Self-citationSensations evoked by intraneural microstimulation of C nociceptor fibres in human skin nerves.
Ochoa, J., & Torebjörk, E. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017737 · Cited by 299
Allard, T., Clark, S. A., Jenkins, W. M., & Merzenich, M. M. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.66.3.1048 · Cited by 295
Brief, Noninjurious Electric Waveform for Stimulation of the Brain
Lilly, J. C., Hughes, J. R., Alvord, E. C., & Galkin, T. W. (1955) · Science · doi:10.1126/science.121.3144.468 · Cited by 287
Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers
Hargrove, L. J., Simon, A. M., Young, A. J., Lipschutz, R. D., Finucane, S. B., Smith, D. G., & Kuiken, T. A. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300126 · Cited by 253
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Self-citationSpataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Resnik, L., Klinger, S. L., & Etter, K. (2014) · Prosthetics & Orthotics International · doi:10.1177/0309364613506913 · Cited by 214
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
The application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
Pei, X., Leuthardt, E. C., Gaona, C. M., Brunner, P., Wolpaw, J. R., & Schalk, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.029 · Cited by 204
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 2×
“with control of up to three different movements from offline decodes [37, 43, 44], and sensory feedback has been provided via electrical stimulation [37, 38, 40, 44, 45, 49, 56, 57] with”
MethodSelf-citationA recurrent neural network for closed-loop intracortical brain–machine interface decoders
Sussillo, D., Nuyujukian, P., Fan, J. M., Kao, J. C., Stavisky, S. D., Ryu, S., & Shenoy, K. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026027 · Cited by 186
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Using the electrocorticographic speech network to control a brain–computer interface in humans
Leuthardt, E. C., Gaona, C., Sharma, M., Szrama, N., Roland, J., Freudenberg, Z., Solis, J., Breshears, J., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036004 · Cited by 161
Kim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., Friehs, G. M., & Black, M. J. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2107750 · Cited by 160
Detecting Neural-State Transitions Using Hidden Markov Models for Motor Cortical Prostheses
Kemere, C., Santhanam, G., Yu, B. M., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00924.2007 · Cited by 157
Xerri, C. (1999) · Cerebral Cortex · doi:10.1093/cercor/9.3.264 · Cited by 145
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Self-citationChestek, C. A., Gilja, V., Blabe, C. H., Foster, B. L., Shenoy, K. V., Parvizi, J., & Henderson, J. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026002 · Cited by 134
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 1×
“Several strategies are being investigated for providing sensory feedback from these new prosthetic limbs including surface vibrators [49], and extraneural [41, 42, 45, 50] or intraneural [44, 51–54] electrodes.”
BackgroundWang, W., Degenhart, A. D., Collinger, J. L., Vinjamuri, R., Sudre, G. P., Adelson, P. D., Holder, D. L., Leuthardt, E. C., Moran, D. W., Boninger, M. L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333704 · Cited by 118
Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111 · cited 1×
“Several strategies are being investigated for providing sensory feedback from these new prosthetic limbs including surface vibrators [49], and extraneural [41, 42, 45, 50] or intraneural [44, 51–54] electrodes.”
BackgroundMinocycline increases quality and longevity of chronic neural recordings
Rennaker, R. L., Miller, J., Tang, H., & Wilson, D. A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l01 · Cited by 108
Leuthardt, E. C., Freudenberg, Z., Bundy, D., & Roland, J. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0980 · Cited by 92
Davis, T. S., Parker, R. A., House, P. A., Bagley, E., Wendelken, S., Normann, R. A., & Greger, B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/065003 · Cited by 91
Self-citationPoston, B., Santos, A. D.-D., Jesunathadas, M., Hamm, T. M., & Santello, M. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00185.2010 · Cited by 91
Hand Shape Representations in the Human Posterior Parietal Cortex
Klaes, C., Kellis, S., Aflalo, T., Lee, B., Pejsa, K., Shanfield, K., Hayes-Jackson, S., Aisen, M., Heck, C., Liu, C., et al. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.2747-15.2015 · Cited by 89
Temporal evolution of gamma activity in human cortex during an overt and covert word repetition task
Leuthardt, E. C., Pei, X.-M., Breshears, J., Gaona, C., Sharma, M., Freudenberg, Z., Barbour, D., & Schalk, G. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00099 · Cited by 81
Clark, G. A., Wendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Normann, R. A., Warren, D. J., & Hutchinson, D. T. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944001 · Cited by 78
Self-citationKellis, S. S., House, P. A., Thomson, K. E., Brown, R., & Greger, B. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0974 · Cited by 74
Self-citationJia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70 · cited 2×
“Motor intent has been decoded online and offline [37, 43, 44, 55]”
BackgroundMethodInvasive neural prosthesis for neural signal detection and nerve stimulation
Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., & Warwick, K. (2005) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.854 · Cited by 66
Electrocorticographic (ECoG) correlates of human arm movements
Anderson, N., Blakely, T. M., Schalk, G., Leuthardt, E. C., & Moran, D. W. (2012) · Experimental Brain Research · doi:10.1007/s00221-012-3226-1 · Cited by 61
Schultz, A. E., Marasco, P. D., & Kuiken, T. A. (2009) · Brain Research · doi:10.1016/j.brainres.2008.11.039 · Cited by 58
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56
Wark, H. A. C., Mathews, K. S., Normann, R. A., & Fernandez, E. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046027 · Cited by 54
Self-citationAdvances in Upper Extremity Prosthetics
Zlotolow, D. A., & Kozin, S. H. (2012) · Hand Clinics · doi:10.1016/j.hcl.2012.08.014 · Cited by 53
"Safe" charge-injection waveforms for iridium oxide (AIROF) microelectrodes
Troyk, P. R., Detlefsen, D. E., Cogan, S. F., Ehrlich, J., Bak, M., McCreery, D. B., Bullara, L., & Schmidt, E. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404155 · Cited by 44
Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33 · cited 1×
“Several strategies are being investigated for providing sensory feedback from these new prosthetic limbs including surface vibrators [49], and extraneural [41, 42, 45, 50] or intraneural [44, 51–54] electrodes.”
BackgroundReal-Time Animation Software for Customized Training to Use Motor Prosthetic Systems
Davoodi, R., & Loeb, G. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178864 · Cited by 29
Decoding hand trajectories from micro-electrocorticography in human patients
Kellis, S., Hanrahan, S. J., Davis, T. S., House, P. A., Brown, R. B., & Greger, B. E. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346866 · Cited by 19
Self-citationDecoding Dexterous Finger Movements in a Neural Prosthesis Model Approaching Real-World Conditions
Egan, J., Baker, J. J., House, P. A., & Greger, B. E. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2210910 · Cited by 12
Self-citation
Research works printed but not linked: 1
- Burck, 2011, Revolutionizing prosthetics: systems engineering challenges and opportunities, Johns Hopkins APL Tech. Dig., 30, 186
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Despite this and other prior translational successes (Clark et al., 2014; Davis et al., 2016; Wendelken et al., 2017), the large degree of trauma and FBR associated with current Utah array designs poses difficult challenges for their widespread clinical use.”
BackgroundMethodGeorge, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Self-citationA closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Metadata
- Authors
- Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B.
- Affiliations
- University of Utah (US)
- Corresponding author
- Greger, B
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-03-22
- Volume
- 13
- Issue
- 3
- Pages
- 036001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2303037278
- Semantic Scholar
- e78d378d1bc89d57daf9f4e7bde4f867b2dc4ff8
- Cited by
- 314
- References
- 78
- Citations by year
- 2026: 7 · 2025: 21 · 2024: 26 · 2023: 22 · 2022: 35 · 2021: 34 · 2020: 45 · 2019: 52 · 2018: 34 · 2017: 32 · 2016: 6
- FWCI
- 23.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Advancing Translational Sciences (1ULTR001067)
- Defence Advanced Research Projects Agency, Microsystems Technology Office (N66001-12-C-4042)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- upper limb amputation, median nerve, ulnar nerve, neuroprosthetics, sensory feedback, electrical stimulation, stimulation threshold, electrode impedance, peripheral nerve interfaces
- MeSH terms
- Amputees, Artificial Limbs, Electric Stimulation, Electrodes, Implanted, Humans, Median Nerve, Microelectrodes, Movement, Neural Pathways, Phantom Limb, Prosthesis Design, Robotics, Ulnar Nerve, Upper Extremity, Feedback, Sensory, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.