A regenerative microchannel neural interface for recording from and stimulating peripheral axons in vivo
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Neural interfaces are implanted devices that couple the nervous system to electronic circuitry. They are intended for long term use to control assistive technologies such as muscle stimulators or prosthetics that compensate for loss of function due to injury. Here we present a novel design of interface for peripheral nerves. Recording from axons is complicated by the small size of extracellular potentials and the concentration of current flow at nodes of Ranvier. Confining axons to microchannels of ~100 µm diameter produces amplified potentials that are independent of node position. After implantation of microchannel arrays into rat sciatic nerve, axons regenerated through the channels forming 'mini-fascicles', each typically containing ~100 myelinated fibres and one or more blood vessels. Regenerated motor axons reconnected to distal muscles, as demonstrated by the recovery of an electromyogram and partial prevention of muscle atrophy. Efferent motor potentials and afferent signals evoked by muscle stretch or cutaneous stimulation were easily recorded from the mini-fascicles and were in the range of 35-170 µV. Individual motor units in distal musculature were activated from channels using stimulus currents in the microampere range. Microchannel interfaces are a potential solution for applications such as prosthetic limb control or enhancing recovery after nerve injury.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, some subjects wearing prostheses with sensory feedback reported that stimulation eliminates phantom pains in the artificial limbs.[157,519]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [519]
In the citing paper
“While originally made from polyimide (FitzGerald et al., 2012), more recent microchannel designs are built from stretchable and softer materials such as PDMS (Musick et al., 2015; Lancashire et al., 2016).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as FitzGerald et al., 2012
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
CONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationInflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Fiber composition of the rat sciatic nerve
Schmalbruch, H. (1986) · The Anatomical Record · doi:10.1002/ar.1092150111 · Cited by 403
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Self-citationPrinciples Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., Davis, L., Jhamandas, J., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 210
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Self-citationEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 168
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Dworak, B. J., & Wheeler, B. C. (2009) · Lab Chip · doi:10.1039/b806689b · Cited by 158
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 129
Electrical Stimulation of Denervated Muscles: First Results of a Clinical Study
Mödlin, M., Forstner, C., Höfer, C., Mayr, W., Richter, W., Carraro, U., Protasi, F., & Kern, H. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29035.x · Cited by 113
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
(1998) · PubMed · Cited by 107
Sumner, A. J. (1990) · Muscle & Nerve · doi:10.1002/mus.880130905 · Cited by 107
Valero-Cabré, A., & Navarro, X. (2002) · Journal of Neurotrauma · doi:10.1089/089771502320914705 · Cited by 92
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 77
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
Self-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
Self-citationA Stimulator for Functional Activation of Denervated Muscles
Höfer, C., Mayr, W., Stöhr, H., Unger, E., & Kern, H. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06951.x · Cited by 75
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68
Self-citationPerformance of alternative amplifier configurations for tripolar nerve cuff recorded ENG
Pflaum, C., Riso, R. R., & Wiesspeiner, G. (2002) · Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.657000 · Cited by 63
Polyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56
Self-citationA review of printed circuit microelectrodes and their production
PICKARD, R. S. (1979) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(79)90019-0 · Cited by 54
(2001) · PubMed · Cited by 52
Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Yoshida, K., Jovanović, K., & Stein, R. B. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00176-4 · Cited by 49
Rutten, W. L. C., Frieswijk, T. A., Smit, J. P. A., Rozijn, T. H., & Meier, J. H. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96802-6 · Cited by 49
Rahal, M., Winter, J., Taylor, J., & Donaldson, N. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867963 · Cited by 47
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Self-citationLoeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46
Microchannel Electrodes for Recording and Stimulation:In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45
Self-citationOn Cuff Imbalance and Tripolar ENG Amplifier Configurations
Triantis, I. F., Demosthenous, A., & Donaldson, N. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840470 · Cited by 45
Changes in Crossed Spinal Reflexes After Peripheral Nerve Injury and Repair
Valero‐Cabré, A., & Navarro, X. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00305.2001 · Cited by 45
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
Bradley, R. M., Smoke, R. H., Akın, T., & Najafi, K. (1992) · Brain Research · doi:10.1016/0006-8993(92)91031-9 · Cited by 44
Use of an Experimentally Derived Leadfield in the Peripheral Nerve Pathway Discrimination Problem
Zariffa, J., Nagai, M. K., Schuettler, M., Stieglitz, T., Daskalakis, Z. J., & Popovic, M. R. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2091429 · Cited by 35
Rozman, J., Zorko, B., & Bunc, M. (2000) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.50.509 · Cited by 34
Wallman, L., Levinsson, A., Schouenborg, J., Holmberg, H., Danielsen, N., & Laurell, T. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.784137 · Cited by 29
Fascicle selective recording with a nerve cuff electrode
Struijk, J. J., Haugland, M. K., & Thomsen, M. (2002) · Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.656993 · Cited by 26
Meier, J. H., Rutten, W. L. C., & Boom, H. B. K. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.709558 · Cited by 22
Endoneural selective stimulating using wire-microelectrode arrays
Smit, J. P. A., Rutten, W. L. C., & Boom, H. B. K. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808943 · Cited by 20
Walter, Griffith, P., Sweeney, J., Scarpine, V., Bidnar, M., McLane, J., & Robinson, C. (1997) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.1997.11719475 · Cited by 18
Selective recording with a multi-contact nerve cuff electrode
Şahin, M., & Durand, D. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656997 · Cited by 17
The influence of bacterial collagenase on regeneration of severed rat sciatic nerves
Wehling, P., Pak, M., Cleveland, S., & Nieper, R. (1992) · Acta Neurochirurgica · doi:10.1007/bf01541795 · Cited by 15
Watling, C. P., Lago, N., Benmerah, S., FitzGerald, J. J., Tarte, E. J., McMahon, S. B., Lacour, S. P., & Cameron, R. E. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.032 · Cited by 15
Self-citationZheng, X., Zhang, J., Chen, T., & Chen, Z. (2008) · Microsurgery · doi:10.1002/micr.20465 · Cited by 14
Wieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038950 · Cited by 13
Recording with microchannel electrodes in a noisy environment
FitzGerald, J. J., Lacour, S. P., & Fawcett, J. W. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649084 · Cited by 10
Self-citation
Research works printed but not linked: 7
- Hoffer J A, 1974, Soc. Neurosci. Abstr, 4, 300
- Kline D G, 1995, Nerve Injuries: Operative Results from Major Nerve Injuries, Entrapments and Tumours
- Navarro X, 1998, J. Peripher. Nerv. Syst., 3, 91
- Navarro X, 2001, Restorative Neurol. Neurosci., 18, 9
- Pflaum C Riso R R Wiesspeiner G, 1996, Proc. 18th Annu. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, 375
- Sahin M Durand D M, 1996, Proc. IEEE Eng. Med. Biol. Soc., 369
- Struijk J J Haugland M K Thomsen M, 1996, Proc. IEEE Eng. Med. Biol. Soc., 361
Cited by
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
Qi, D., Liu, Z., Liu, Y., Jiang, Y., Leow, W. R., Pal, M., Pan, S., Yang, H., Wang, Y., Zhang, X., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702800 · Cited by 196
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Metadata
- Authors
- FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W.
- Affiliations
- University of Cambridge (GB)
- King's College London (GB)
- University of Birmingham (GB)
- Parc Científic de Barcelona (ES)
- ORCID
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-01-19
- Volume
- 9
- Issue
- 1
- Pages
- 016010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2070939443
- Semantic Scholar
- 946c5a96179ccd4e86f1be61283df0631ee68b4c
- Cited by
- 73
- References
- 59
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 6 · 2020: 2 · 2019: 7 · 2018: 8 · 2017: 8 · 2016: 8 · 2015: 9 · 2014: 6 · 2013: 6 · 2012: 1
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Portal (King's College London) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- Wellcome Trust
- Engineering and Physical Sciences Research Council (EP/H00727X/1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- neural interfaces, microchannel arrays, peripheral nerve regeneration, sciatic nerve, peripheral nerve stimulation, motor unit activation, electromyography, muscle atrophy prevention, nerve recovery, prosthetic control, nodes of Ranvier
- MeSH terms
- Action Potentials, Animals, Axons, Electric Stimulation, Equipment Design, Male, Miniaturization, Rats, Inbred Lew, Sciatic Nerve, Equipment Failure Analysis, Rats, Implantable Neurostimulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.