The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Abstract
We describe a study designed to assess a brain-computer interface (BCI), originally described by Farwell and Donchin [9] in 1988. The system utilizes the fact that the rare events in the oddball paradigm elicit the P300 component of the event-related potential (ERP). The BCI presents the user with a matrix of 6 by 6 cells, each containing one letter of the alphabet. The user focuses attention on the cell containing the letter to be communicated while the rows and the columns of the matrix are intensified. Each intensification is an event in the oddball sequence, the row and the column containing the attended cell are "rare" items and, therefore, only these events elicit a P300. The computer thus detects the transmitted character by determining which row and which column elicited the P300. We report an assessment, using a boot-strapping approach, which indicates that an off line version of the system can communicate at the rate of 7.8 characters a minute and achieve 80% accuracy. The system's performance in real time was also assessed. Our data indicate that a P300-based BCI is feasible and practical. However, these conclusions are based on tests using healthy individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055 · cited 1×
“Vertical and horizontal EOG artifacts were removed from the EEG by an eye-movement correction method [10].”
MethodSelf-citationIs the P300 component a manifestation of context updating?
Donchin, E., & Coles, M. G. H. (1988) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00058027 · Cited by 3,585
Self-citationFarwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Self-citationEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Event-Related Brain Potentials in Man
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-155150-6.x5001-9 · Cited by 954
Fabiani, M., Gratton, G., Karis, D., & Donchin, E. (1987) · Digital Commons - University of South Florida (University of South Florida) · Cited by 451
Self-citationCOGNITIVE PSYCHOPHYSIOLOGY: THE ENDOGENOUS COMPONENTS OF THE ERP
DONCHIN, E., RITTER, W., & MCCALLUM, W. C. (1978) · Event-Related Brain Potentials in Man · doi:10.1016/b978-0-12-155150-6.50019-5 · Cited by 415
Self-citation
Research works printed but not linked: 1
- bauby, 1997, The Diving Bell and the Butterfly, 132
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Self-citationMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Duncan, C. C., Barry, R. J., Connolly, J. F., Fischer, C., Michie, P. T., Näätänen, R., Polich, J., Reinvang, I., & Van Petten, C. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.07.045 · Cited by 1,191
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
The BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Zander, T. O., & Kothe, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 887
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Renard, Y., Lotte, F., Gibert, G., Congedo, M., Maby, E., Delannoy, V., Bertrand, O., & Lécuyer, A. (2010) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.19.1.35 · Cited by 830
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Convolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711
Self-citationBlankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633
Brain-computer communication: Unlocking the locked in.
Kübler, A., Kotchoubey, B., Kaiser, J., Wolpaw, J. R., & Birbaumer, N. (2001) · Psychological Bulletin · doi:10.1037//0033-2909.127.3.358 · Cited by 553
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537
“However, these repetitions decrease the number of symbols spelled per minute, e.g., with 15 repetitions, only two characters are typically spelled per minute [1], [ 8 ].”
BackgroundMethodInfluentialBrain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
BCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Sellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
EEG source imaging enhances the decoding of complex right-hand motor imagery tasks
Edelman, B. J., Baxter, B., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467312 · Cited by 370
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362
On the suitability of near-infrared (NIR) systems for next-generation brain–computer interfaces
Coyle, S., Ward, T., Markham, C., & McDarby, G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/003 · Cited by 361
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Bostanov, V. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826702 · Cited by 346
An Asynchronously Controlled EEG-Based Virtual Keyboard: Improvement of the Spelling Rate
Scherer, R., Muller, G. R., Neuper, C., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827062 · Cited by 340
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Towards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
An auditory oddball (P300) spelling system for brain‐computer interfaces
Furdea, A., Halder, S., Krusienski, D. J., Bross, D., Nijboer, F., Birbaumer, N., & Kübler, A. (2009) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00783.x · Cited by 326
Piccione, F., Giorgi, F., Tonin, P., Priftis, K., Giove, S., Silvoni, S., Palmas, G., & Beverina, F. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.024 · Cited by 325
A Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
Parasuraman, R., & Rizzo, M. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195177619.001.0001 · Cited by 311
Kübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Flashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
An EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
Does the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Graz-BCI: state of the art and clinical applications
Pfurtscheller, G., Neuper, C., Muller, G. R., Obermaier, B., Krausz, G., Schlogl, A., Scherer, R., Graimann, B., Keinrath, C., Skliris, D., et al. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814454 · Cited by 286
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Brain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
Robust classification of EEG signal for brain-computer interface
Thulasidas, M., Guan, C., & Wu, J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.862695 · Cited by 261
Motivation modulates the P300 amplitude during brain–computer interface use
Kleih, S. C., Nijboer, F., Halder, S., & Kübler, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.034 · Cited by 258
Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258
Cortically coupled computer vision for rapid image search
Gerson, A. D., Parra, L. C., & Sajda, P. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875550 · Cited by 258
A Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
A Self-Paced and Calibration-Less SSVEP-Based Brain–Computer Interface Speller
Cecotti, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039594 · Cited by 253
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Noninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
Huggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215
BCI meeting 2005-workshop on BCI signal processing: feature extraction and translation
McFarland, D. J., Anderson, C. W., Muller, K.-R., Schlogl, A., & Krusienski, D. J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875637 · Cited by 204
BMI control of a third arm for multitasking
Penaloza, C. I., & Nishio, S. (2018) · Science Robotics · doi:10.1126/scirobotics.aat1228 · Cited by 169
A Collaborative Brain-Computer Interface for Improving Human Performance
Wang, Y., & Jung, T.-P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020422 · Cited by 147
Convolutional Neural Network for Multi-Category Rapid Serial Visual Presentation BCI
Manor, R., & Geva, A. B. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00146 · Cited by 144
Spüler, M., Bensch, M., Kleih, S., Rosenstiel, W., Bogdan, M., & Kübler, A. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.082 · Cited by 144
Unsupervised Brain Computer Interface Based on Intersubject Information and Online Adaptation
Lu, S., Guan, C., & Zhang, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015197 · Cited by 122
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
Effects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
Clinical evaluation of BrainTree, a motor imagery hybrid BCI speller
Perdikis, S., Leeb, R., Williamson, J., Ramsay, A., Tavella, M., Desideri, L., Hoogerwerf, E.-J., Al-Khodairy, A., Murray-Smith, R., & Millán, J. D. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036003 · Cited by 85
“event-related potentials (ERPs) [3, 4], sensorimotor rhythms (SMR) [5, 6], or low-frequency asynchronous switch design (LF-ASD) [7].”
BackgroundFuhrmann Alpert, G., Manor, R., Spanier, A. B., Deouell, L. Y., & Geva, A. B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2289898 · Cited by 74
A systematic deep learning model selection for p300-based brain-computer interfaces
Abibullaev, B., & Zollanvari, A. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2021.3051136 · Cited by 53
Cecotti, H., & Ries, A. J. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.07.500 · Cited by 50
Matran-Fernandez, A., & Poli, R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0178498 · Cited by 45
A comparison study of two P300 speller paradigms for brain–computer interface
Pan, J., Li, Y., Gu, Z., & Yu, Z. (2013) · Cognitive Neurodynamics · doi:10.1007/s11571-013-9253-1 · Cited by 46
Single-trial EEG RSVP classification using convolutional neural networks
Shamwell, J., Lee, H., Kwon, H., Marathe, A. R., Lawhern, V., & Nothwang, W. (2016) · SPIE Proceedings · doi:10.1117/12.2224172 · Cited by 34
PHOTHISONOTHAI, M., & NAKAGAWA, M. (2008) · IEICE Transactions on Information and Systems · doi:10.1093/ietisy/e91-d.1.44 · Cited by 33
Simistira Liwicki, F., Gupta, V., Saini, R., De, K., Abid, N., Rakesh, S., Wellington, S., Wilson, H., Liwicki, M., & Eriksson, J. (2023) · Scientific Data · doi:10.1038/s41597-023-02286-w · Cited by 28
Davanzo, N., & Avanzini, F. (2020) · IEEE Access · doi:10.1109/access.2020.3019978 · Cited by 16
“The ‘‘P300 speller’’ is perhaps the best known embodiment of this paradigm, and allows to select letters from a matrix [107].”
Background
Metadata
- Authors
- Donchin, E., Spencer, K. M., & Wijesinghe, R.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000-06
- Volume
- 8
- Issue
- 2
- Pages
- 174-179
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2168689324
- Cited by
- 1,222
- References
- 13
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.