Translating the Brain-Machine Interface
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces hold promise for the recovery of sensory and motor functions, but translational challenges remain.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [271]
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Electrical activity in the brain is accompanied by changes in blood f ow and oxygenation, and these parameters might be used in BMIs ( 16 ).”
MethodNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Current-generation algorithms and implanted systems have demonstrated improved decoding accuracies and reliability of performance in nonhuman primates (72) and provocative outcomes in tetraplegic patients (67, 68).”
BackgroundReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“Tathireddy, A new high-density (25 electrodes/ mm((2)) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures.”
BackgroundHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · cited 1×
“Design approaches include the use of conventional materials such as platinum electrodes embedded in silicone and unconventional f exible electrodes made of materials such as pyrelene, polyimide, and silk f ber (24).”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“Indeed, the technology and experimentation have progressed to the point of including BMIs of the motor ( 37 ) and sensory ( 26 ) systems, raising the potential for bidirectional communication to and from the nervous system ( 38 , 39 ) (Fig.”
BackgroundDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Harkema, S., Gerasimenko, Y., Hodes, J., Burdick, J., Angeli, C., Chen, Y., Ferreira, C., Willhite, A., Rejc, E., Grossman, R. G., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60547-3 · Cited by 1,229 · cited 2×
“Other neural prosthetic devices such as nerve (62–64), spinal cord (65, 66), and sensory-motor prostheses (26, 27, 67–70) that either restore motion or return sensory feedback are undergoing intense R&D as well as early-stage clinical demonstrations.”
BackgroundSpoken Language Development in Children Following Cochlear Implantation
Niparko, J. K. (2010) · JAMA · doi:10.1001/jama.2010.451 · Cited by 1,208
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149 · cited 1×
“Various computational methods are used to interpret changes in EEGs or ERPs as a subject’s intent to communicate a message to a computer (BCI) or to control a machine (BMI) such as a wheelchair ( 5 ) or a device that assists with rehabilitation ( 7 ).”
MethodViventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Truccolo, W., Eden, U. T., Fellows, M. R., Donoghue, J. P., & Brown, E. N. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00697.2004 · Cited by 1,049
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Restoring Voluntary Control of Locomotion after Paralyzing Spinal Cord Injury
van den Brand, R., Heutschi, J., Barraud, Q., DiGiovanna, J., Bartholdi, K., Huerlimann, M., Friedli, L., Vollenweider, I., Moraud, E. M., Duis, S., et al. (2012) · Science · doi:10.1126/science.1217416 · Cited by 767 · cited 1×
“Other neural prosthetic devices such as nerve ( 62 – 64 ), spinal cord ( 65 , 66 ), and sensory-motor prostheses ( 26 , 27 , 67 – 70 ) that either restore motion or return sensory feedback are undergoing intense R&D as well as early-stage clinical demonstrations.”
BackgroundKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · cited 2×
“…next silicon-based microfabricated electrode arrays, and most recently advanced two-and three-dimensional arrays ( 33 ) and integrated microelectrodes and circuits have greatly advanced the ability to record electrophysiological activity from a large number of neurons simultaneously ( 34–36 ).”
BackgroundFunctional organization of human sensorimotor cortex for speech articulation
Bouchard, K. E., Mesgarani, N., Johnson, K., & Chang, E. F. (2013) · Nature · doi:10.1038/nature11911 · Cited by 686 · cited 1×
“…gura-tion and interaction of articulators such as the lips, tongue, and palate), mapping the organization of speech-producing regions in the brain ( 29 ), and reconstructing speech by decoding the ECoG signals correlated with speech production (that is, word selection, phonetics formulation, and…”
BackgroundHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 1×
“Analogously, event (or stimulus)– related potentials (ERPs)—such as the P300 signal, which occurs ~300 ms af er a visual stimulus—are also used for BMIs (6).”
MethodActive tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Reconstructing Speech from Human Auditory Cortex
Pasley, B. N., David, S. V., Mesgarani, N., Flinker, A., Shamma, S. A., Crone, N. E., Knight, R. T., & Chang, E. F. (2012) · PLoS Biology · doi:10.1371/journal.pbio.1001251 · Cited by 604 · cited 2×
“Beyond these, more developed applications, such as prostheses that restore speech ( 28 – 30 ) or memory ( 73 ), are also being investigated, although these research projects are in early stages of feasibility testing and demonstration.”
BackgroundLaFleur, K., Cassady, K., Doud, A., Shades, K., Rogin, E., & He, B. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046003 · Cited by 583 · cited 1×
“Stateof-the-art BMIs control up to three degrees of freedom (12) (that is, three independent sets of BCI commands or BMI movements).”
BackgroundEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 1×
“Further, during any motor or BMI task, neurons have the ability to adapt to a task (“tuning”) and create a stable pattern of activity to facilitate reliable decoding ( 50 ). is adaptability of neurons can be an asset because, instead of tuning an algorithm to achieve the desired Fig.”
BackgroundA high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485 · cited 2×
“Another direction would be to provide sensory feedback through microstimulation, which involves the use of microelectrodes and electrical current to stimulate a small population of neurons (26, 27).”
BackgroundWeiskopf, N., Mathiak, K., Bock, S. W., Scharnowski, F., Veit, R., Grodd, W., Goebel, R., & Birbaumer, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827063 · Cited by 420
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“Other neural prosthetic devices such as nerve ( 62 – 64 ), spinal cord ( 65 , 66 ), and sensory-motor prostheses ( 26 , 27 , 67 – 70 ) that either restore motion or return sensory feedback are undergoing intense R&D as well as early-stage clinical demonstrations.”
BackgroundReconstructing Three-Dimensional Hand Movements from Noninvasive Electroencephalographic Signals
Bradberry, T. J., Gentili, R. J., & Contreras-Vidal, J. L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.6107-09.2010 · Cited by 360
Dynamic Analysis of Neural Encoding by Point Process Adaptive Filtering
Eden, U. T., Frank, L. M., Barbieri, R., Solo, V., & Brown, E. N. (2004) · Neural Computation · doi:10.1162/089976604773135069 · Cited by 350
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Chao (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00003 · Cited by 341
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Selecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
A cortical neural prosthesis for restoring and enhancing memory
Berger, T. W., Hampson, R. E., Song, D., Goonawardena, A., Marmarelis, V. Z., & Deadwyler, S. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046017 · Cited by 313
A Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces
Chi, Y. M., Wang, Y.-T., Wang, Y., Maier, C., Jung, T.-P., & Cauwenberghs, G. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2174652 · Cited by 297
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Dobkin, B. H. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.123067 · Cited by 256
A Brain-to-Brain Interface for Real-Time Sharing of Sensorimotor Information
Pais-Vieira, M., Lebedev, M., Kunicki, C., Wang, J., & Nicolelis, M. A. L. (2013) · Scientific Reports · doi:10.1038/srep01319 · Cited by 252
Neural decoding of treadmill walking from noninvasive electroencephalographic signals
Presacco, A., Goodman, R., Forrester, L., & Contreras-Vidal, J. L. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00104.2011 · Cited by 203
Retinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 199
Modulation of Muscle Synergy Recruitment in Primate Grasping
Overduin, S. A., d'Avella, A., Roh, J., & Bizzi, E. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2869-07.2008 · Cited by 190
Fighting Blindness with Microelectronics
Zrenner, E. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007399 · Cited by 190
Single-Neuron Stability during Repeated Reaching in Macaque Premotor Cortex
Chestek, C. A., Batista, A. P., Santhanam, G., Yu, B. M., Afshar, A., Cunningham, J. P., Gilja, V., Ryu, S. I., Churchland, M. M., & Shenoy, K. V. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0959-07.2007 · Cited by 174
Coadaptive Brain–Machine Interface via Reinforcement Learning
DiGiovanna, J., Mahmoudi, B., Fortes, J., Principe, J. C., & Sanchez, J. C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926699 · Cited by 174
Zhuang, J., Truccolo, W., Vargas-Irwin, C., & Donoghue, J. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2047015 · Cited by 174
Borton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171
Brain–machine interface via real-time fMRI: Preliminary study on thought-controlled robotic arm
Lee, J.-H., Ryu, J., Jolesz, F. A., Cho, Z.-H., & Yoo, S.-S. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2008.11.024 · Cited by 156
Hemodynamics for Brain-Computer Interfaces
Matthews, F., Pearlmutter, B., Wards, T., Soraghan, C., & Markham, C. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408445 · Cited by 153
A Dry EEG-System for Scientific Research and Brain–Computer Interfaces
Zander, T. O., Lehne, M., Ihme, K., Jatzev, S., Correia, J., Kothe, C., Picht, B., & Nijboer, F. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00053 · Cited by 150
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148 · cited 1×
“First metal microelectrodes, next silicon-based microfabricated electrode arrays, and most recently advanced two-and three-dimensional arrays ( 33 ) and integrated microelectrodes and circuits have greatly advanced the ability to record electrophysiological activity from a large number of neurons…”
BackgroundHermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 136
Nurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y.-K., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Ming, Y., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 127
Moran, D. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.09.010 · Cited by 103
Shanechi, M. M., Hu, R. C., Powers, M., Wornell, G. W., Brown, E. N., & Williams, Z. M. (2012) · Nature Neuroscience · doi:10.1038/nn.3250 · Cited by 96
Kinetic Trajectory Decoding Using Motor Cortical Ensembles
Fagg, A. H., Ojakangas, G. W., Miller, L. E., & Hatsopoulos, N. G. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029313 · Cited by 93
Brain Control of Movement Execution Onset Using Local Field Potentials in Posterior Parietal Cortex
Hwang, E. J., & Andersen, R. A. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.2081-09.2009 · Cited by 89
Rothschild, R. M. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00112 · Cited by 84
Signal Processing Challenges for Neural Prostheses
Linderman, M. D., Santhanam, G., Kemere, C. T., Gilja, V., O’Driscoll, S., Yu, B. M., Afshar, A., Ryu, S. I., Shenoy, K. V., & Meng, T. H. Y. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408439 · Cited by 84
Aggarwal, V., Mollazadeh, M., Davidson, A. G., Schieber, M. H., & Thakor, N. V. (2013) · Journal of Neurophysiology · doi:10.1152/jn.01038.2011 · Cited by 83
Self-citationPredicting Consumer Behavior: Using Novel Mind-Reading Approaches
Calvert, G. A., & Brammer, M. J. (2012) · IEEE Pulse · doi:10.1109/mpul.2012.2189167 · Cited by 75
Mollazadeh, M., Aggarwal, V., Davidson, A. G., Law, A. J., Thakor, N. V., & Schieber, M. H. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2999-11.2011 · Cited by 74
Self-citationFifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175636 · Cited by 74
Self-citationThe Argus® II retinal prosthesis system: An overview
Zhou, D. D., Dorn, J. D., & Greenberg, R. J. (2013) · 2013 IEEE International Conference on Multimedia and Expo Workshops (ICMEW) · doi:10.1109/icmew.2013.6618428 · Cited by 70
Collinger, J. L., Kryger, M. A., Barbara, R., Betler, T., Bowsher, K., Brown, E. H. P., Clanton, S. T., Degenhart, A. D., Foldes, S. T., Gaunt, R. A., et al. (2014) · Clinical and Translational Science · doi:10.1111/cts.12086 · Cited by 68 · cited 4×
“Motor prostheses have achieved the best translation from research in nonhuman primate models to human subjects in the clinic ( 70 ), beginning with the demonstration of robotic control mechanisms using neural signals for commands ( 71 ) to demonstration of multiple degrees of freedom movement ( 45…”
BackgroundInfluentialMillán, J. D. R. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch12 · Cited by 63
Restoration of Whole Body Movement: Toward a Noninvasive Brain-Machine Interface System
Contreras-Vidal, J. L., Presacco, A., Agashe, H. A., & Paek, A. Y. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175635 · Cited by 32
Zhang, F., Aghagolzadeh, M., & Oweiss, K. G. (2012) · Journal of Signal Processing Systems · doi:10.1007/s11265-012-0670-x · Cited by 25
Recording Brain Waves at the Supermarket: What Can We Learn from a Shopper's Brain?
Sands, S. F., & Sands, J. A. (2012) · IEEE Pulse · doi:10.1109/mpul.2012.2189170 · Cited by 20
Research works printed but not linked: 1
- J. Millán Brain machine interfaces in Introduction to Neural Engineering for Motor Rehabilitation . D. Farina W. Jensen M. Akay Eds. (J. W. Wiley New Jersey 2013) pp. 237-251.
Cited by
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016) · Scientific Reports · doi:10.1038/srep38565 · Cited by 484
Flexible brain–computer interfaces
Tang, X., Shen, H., Zhao, S., Li, N., & Liu, J. (2023) · Nature Electronics · doi:10.1038/s41928-022-00913-9 · Cited by 373
“(1) Low-power-demanding integrated circuits”
BackgroundMethodInfluentialMood variations decoded from multi-site intracranial human brain activity
Sani, O. G., Yang, Y., Lee, M. B., Dawes, H. E., Chang, E. F., & Shanechi, M. M. (2018) · Nature Biotechnology · doi:10.1038/nbt.4200 · Cited by 230
Metadata
- Authors
- Thakor, N. V.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Thakor, Nitish V.
- ORCID
- Thakor, Nitish V.
- Venue
- Science Translational Medicine
- Published
- 2013-11-06
- Volume
- 5
- Issue
- 210
- Pages
- 210ps17-210ps17
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2160541742
- Cited by
- 128
- References
- 76
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 7 · 2023: 11 · 2022: 17 · 2021: 9 · 2020: 10 · 2019: 15 · 2018: 8 · 2017: 10 · 2016: 7 · 2015: 10 · 2014: 11 · 2013: 1
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- brain-computer interface, neuroprosthetics, non-invasive brain stimulation, invasive neural recording, motor recovery, sensory recovery, nervous system injury, amputation, clinical translation
- MeSH terms
- Clinical Trials as Topic, Humans, Translational Research, Biomedical, Neural Prostheses, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.