Echo-planar imaging of intravoxel incoherent motion.
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The recently established single-shot technique of echo-planar imaging of intravoxel incoherent motion (IVIM) for determining and imaging the variations of microscopic motions of water has been applied to studies of water perfusion in phantoms and to in vivo studies of diffusion and perfusion in cat and human brains. The phantom results demonstrate that perfusion levels comparable with those found in vivo have easily observable and reproducible effects on signal amplitude that are consistent with previous IVIM theory. Reliable measurements of the diffusion coefficient in various types of brain tissue have been obtained. The results for white matter are consistent with the existence of anisotropic diffusion in oriented bundles of myelinated nerve fibers. The results for gray matter can be fitted to the IVIM theory and suggest a value of up to 14% for the fraction of the signal contributed by randomly perfusing fluid in normal cerebral cortex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 8×
“The concept of “diffusion imaging” is much more recent (1,2,14).”
BackgroundMethodResultInfluentialSeparation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
Self-citationMulti-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Importance of classical diffusion in NMR studies of water in biological cells
Brownstein, K. R., & Tarr, C. E. (1979) · Physical Review A · doi:10.1103/physreva.19.2446 · Cited by 1,422
Quantitative interpretation of NMR relaxation data
Whittall, K. P., & MacKay, A. L. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90011-5 · Cited by 628
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Le Bihan, D., Delannoy, J., & Levin, R. L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717764 · Cited by 493
Self-citationPawlik, G., Rackl, A., & Bing, R. J. (1981) · Brain Research · doi:10.1016/0006-8993(81)90619-3 · Cited by 311
Cited by
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Principles of diffusion tensor imaging and its applications to basic neuroscience research
Mori, S., & Zhang, J. (2006) · Neuron · doi:10.1016/j.neuron.2006.08.012 · Cited by 1,708
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Basser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Maturation of white matter in the human brain: A review of magnetic resonance studies.
Paus, T., Collins, D. L., Evans, A. C., Leonard, G., Pike, B., & Zijdenbos, A. (2001) · Brain Research Bulletin · doi:10.1016/s0361-9230(00)00434-2 · Cited by 863
Basic principles of diffusion-weighted imaging
Bammer, R. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00303-0 · Cited by 851
Optimized EPI for fMRI studies of the orbitofrontal cortex
Deichmann, R., Gottfried, J. A., Hutton, C., & Turner, R. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00073-9 · Cited by 821
Self-citationProcessing and visualization for diffusion tensor MRI
Westin, C.-F., Maier, S. E., Mamata, H., Nabavi, A., Jolesz, F. A., & Kikinis, R. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00053-1 · Cited by 812
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
A review of diffusion tensor imaging studies in schizophrenia
Kubicki, M., McCarley, R., Westin, C.-F., Park, H.-J., Maier, S., Kikinis, R., Jolesz, F. A., & Shenton, M. E. (2007) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.05.005 · Cited by 769
Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
Chenevert, T. L. (2000) · Journal of the National Cancer Institute · doi:10.1093/jnci/92.24.2029 · Cited by 673
Moffat, B. A., Chenevert, T. L., Lawrence, T. S., Meyer, C. R., Johnson, T. D., Dong, Q., Tsien, C., Mukherji, S., Quint, D. J., Gebarski, S. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501532102 · Cited by 643
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Self-citationPorter, D. A., & Heidemann, R. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22024 · Cited by 593
Diffusion Tensor MR Imaging and Fiber Tractography: Theoretic Underpinnings
Mukherjee, P., Berman, J. I., Chung, S. W., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1051 · Cited by 521
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Diffusion MRI at 25: exploring brain tissue structure and function
Le Bihan, D., & Johansen-Berg, H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.006 · Cited by 498
“Because EPI is a “singleshot” acquisition technique motion artifacts are virtually eliminated (Avram and Crooks, 1988; McKinstry et al., 1990; Turner et al., 1990).”
BackgroundInfluentialSelf-citationWhat can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Self-citationFunctional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Self-citationBürgel, U., Amunts, K., Hoemke, L., Mohlberg, H., Gilsbach, J. M., & Zilles, K. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.040 · Cited by 432
Echo‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
Self-citationMahmoudi, M., Hosseinkhani, H., Hosseinkhani, M., Boutry, S., Simchi, A., Journeay, W. S., Subramani, K., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr1001832 · Cited by 418
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Diffusion weighted imaging: Technique and applications
Baliyan, V., Das, C. J., Sharma, R., & Gupta, A. K. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i9.785 · Cited by 395
Jones, D. K., & Leemans, A. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_6 · Cited by 379
Kubicki, M., Westin, C.-F., Nestor, P. G., Wible, C. G., Frumin, M., Maier, S. E., Kikinis, R., Jolesz, F. A., McCarley, R. W., & Shenton, M. E. (2003) · Biological Psychiatry · doi:10.1016/s0006-3223(03)00419-0 · Cited by 376
“…parameters were used: rectangular field of view (FOV) 220 × 165 mm; 128 × 128 scan matrix (256 × 256 image 2Unlike the single-shot echo planar imaging (Turner et al 1990) and navigated echo pulsed gradient spin echo imaging (Ordidge et al 1994), the most commonly used magnetic resonance…”
MethodTechnology Insight: water diffusion MRI—a potential new biomarker of response to cancer therapy
Patterson, D. M., Padhani, A. R., & Collins, D. J. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1073 · Cited by 365
Rojkova, K., Volle, E., Urbanski, M., Humbert, F., Dell’Acqua, F., & Thiebaut de Schotten, M. (2016) · Brain Structure and Function · doi:10.1007/s00429-015-1001-3 · Cited by 361
Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
Jezzard, P., Barnett, A. S., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390518 · Cited by 352
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Correction of motional artifacts in diffusion-weighted MR images using navigator echoes
Ordidge, R. J., Helpern, J. A., Qing, Z. X., Knight, R. A., & Nagesh, V. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92539-9 · Cited by 331
Q-space trajectory imaging for multidimensional diffusion MRI of the human brain
Westin, C.-F., Knutsson, H., Pasternak, O., Szczepankiewicz, F., Özarslan, E., van Westen, D., Mattisson, C., Bogren, M., O'Donnell, L. J., Kubicki, M., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.039 · Cited by 327
Correction for distortion of echo‐planar images used to calculate the apparent diffusion coefficient
Haselgrove, J. C., & Moore, J. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360620 · Cited by 324
Diffusion magnetic resonance imaging: Its principle and applications
Mori, S., & Barker, P. B. (1999) · The Anatomical Record · doi:10.1002/(sici)1097-0185(19990615)257:3<102::aid-ar7>3.0.co;2-6 · Cited by 317
Shimony, J. S., McKinstry, R. C., Akbudak, E., Aronovitz, J. A., Snyder, A. Z., Lori, N. F., Cull, T. S., & Conturo, T. E. (1999) · Radiology · doi:10.1148/radiology.212.3.r99au51770 · Cited by 315
Diffusion Tensor MR Imaging of the Brain and White Matter Tractography
Melhem, E. R., Mori, S., Mukundan, G., Kraut, M. A., Pomper, M. G., & van Zijl, P. C. M. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.1.1780003 · Cited by 304
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Self-citationDiffusion Magnetic Resonance Imaging: What Water Tells Us about Biological Tissues
Le Bihan, D., & Iima, M. (2015) · PLOS Biology · doi:10.1371/journal.pbio.1002203 · Cited by 297
Self-citationLe Bihan, D., Turner, R., Moonen, C. T. W., & Pekar, J. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010103 · Cited by 288
Self-citationAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J. L. R., & Skare, S. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 274
Changes in water diffusion due to Wallerian degeneration in peripheral nerve
Beaulieu, C., Does, M. D., Snyder, R. E., & Allen, P. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360419 · Cited by 267
Diffusion-weighted imaging (DWI) in musculoskeletal MRI: a critical review
Khoo, M. M. Y., Tyler, P. A., Saifuddin, A., & Padhani, A. R. (2011) · Skeletal Radiology · doi:10.1007/s00256-011-1106-6 · Cited by 258
The use of power images to perform quantitative analysis on low SNR MR images
Miller, A. J., & Joseph, P. M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90225-3 · Cited by 244
Issa, B. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10139 · Cited by 243
“The mapping of apparent diffusion coefficient (ADC) on the brain (2,3) has gained from recent advances in hardware improvement and the application of fast imaging methods (4,5).”
The b matrix in diffusion tensor echo‐planar imaging
Mattiello, J., Basser, P. J., & Le Bihan, D. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370226 · Cited by 239
Self-citationDiffusion tensor MRI of the human kidney
Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1149 · Cited by 236
Peled, S., & Yeshurun, Y. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<29::aid-mrm1005>3.0.co;2-z · Cited by 235
“● The most popular diffusion imaging sequences are the ultrafast sequences, such as the diffusion-sensitized echo-planar imaging (EPI) technique (5), which acquire a complete image in one shot, thus avoiding phase problems.”
BackgroundGudbjartsson, H., Maier, S. E., Mulkern, R. V., Mórocz, I. Á., Patz, S., & Jolesz, F. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360403 · Cited by 227
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Blamire, A. M., Anthony, D. C., Rajagopalan, B., Sibson, N. R., Perry, V. H., & Styles, P. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-21-08153.2000 · Cited by 210
“Images of the ADC were generated from the diffusion-weighted images (Turner et al., 1990).”
MethodDiffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience
Federau, C., O'Brien, K., Meuli, R., Hagmann, P., & Maeder, P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24195 · Cited by 204
A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI
Papadakis, N. G., Xing, D., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1673 · Cited by 203
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
“[79], based on intravoxel incoherent motion MRI [80–84], also has suggested that restricted diffusion observed in patients with cirrhosis reflects diminished capillary perfusion and, to a much lesser extent, pure molecular diffusion.”
MethodDiffusion‐weighted MRI in the characterization of soft‐tissue tumors
van Rijswijk, C. S. P., Kunz, P., Hogendoorn, P. C. W., Taminiau, A. H. M., Doornbos, J., & Bloem, J. L. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10061 · Cited by 194
“Measurement of signal attenuation at different diffusion-sensitizing gradient strengths allows the estimation of true diffusion coefficients and the perfusion fraction (1,10,11), using:”
BackgroundMethodInfluentialQuantitative Measurement of Brain Perfusion with Intravoxel Incoherent Motion MR Imaging
Federau, C., Maeder, P., O’Brien, K., Browaeys, P., Meuli, R., & Hagmann, P. (2012) · Radiology · doi:10.1148/radiol.12120584 · Cited by 191
Diffusion imaging of brain tumors
Maier, S. E., Sun, Y., & Mulkern, R. V. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1544 · Cited by 184
Jones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 183
“Initial attempts to exploit this sensitivity built upon the concept of intravoxel incoherent motion (IVIM) reflecting the displacement of water molecules in the pseudo-randomly orientated capillary network at low b-values (less than 100-200 s/mm(2)) (Turner et al., 1990).”
KUROKI, Y., NASU, K., KUROKI, S., MURAKAMI, K., HAYASHI, T., SEKIGUCHI, R., & NAWANO, S. (2004) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.3.79 · Cited by 182
Computing the Social Brain Connectome Across Systems and States
Alcalá-López, D., Smallwood, J., Jefferies, E., Van Overwalle, F., Vogeley, K., Mars, R. B., Turetsky, B. I., Laird, A. R., Fox, P. T., Eickhoff, S. B., et al. (2018) · Cerebral Cortex · doi:10.1093/cercor/bhx121 · Cited by 180
“Different methods have been introduced to reduce the susceptibility to this effect and increase signal recovery (e.g., Turner et al. 1990; Merboldt et al. 2001).”
MethodHoehn‐berlar, M., Eis, M., Back, T., Kohno, K., & Yamashita, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340607 · Cited by 180
A study of rotationally invariant and symmetric indices of diffusion anisotropy
Papadakis, N. G., Xing, D., Houston, G. C., Smith, J. M., Smith, M. I., James, M. F., Parsons, A. A., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00029-6 · Cited by 179
Jones, D. K., Williams, S. C. R., Gasston, D., Horsfield, M. A., Simmons, A., & Howard, R. (2002) · Human Brain Mapping · doi:10.1002/hbm.10018 · Cited by 179
“Thus, even with rapid imaging techniques such as EPI, the reliability of diffusion measurements is substantially improved if the acquisition is gated to the cardiac cycle [Conturo et al., 1995; Turner et al., 1990; Wieshmann et al., 1998].”
BackgroundMethodMagnetic resonance imaging shows orientation and asymmetry of white matter fiber tracts
Peled, S., Gudbjartsson, H., Westin, C.-F., Kikinis, R., & Jolesz, F. A. (1998) · Brain Research · doi:10.1016/s0006-8993(97)00635-5 · Cited by 177
Optimization of a free water elimination two-compartment model for diffusion tensor imaging
Hoy, A. R., Koay, C. G., Kecskemeti, S. R., & Alexander, A. L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.053 · Cited by 173
“Two-hundred was established as the minimum b-value to ensure that perfusion effects were avoided (Turner et al., 1990).”
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1999) · Abdominal Imaging · doi:10.1007/s002619900539 · Cited by 173
Phase insensitive preparation of single‐shot RARE: Application to diffusion imaging in humans
Alsop, D. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380404 · Cited by 173
Dardzinski, B. J., Sotak, C. H., Fisher, M., Hasegawa, Y., Li, L., & Minematsu, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300307 · Cited by 170
Mishra, A. M., Gupta, R. K., Jaggi, R. S., Reddy, J. S., Jha, D. K., Husain, N., Prasad, K. N., Behari, S., & Husain, M. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200407000-00017 · Cited by 161
Butts, K., Pauly, J., De Crespigny, A., & Moseley, M. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380510 · Cited by 160
Image Processing for Diffusion Tensor Magnetic Resonance Imaging
Westin, C. F., Maier, S. E., Khidhir, B., Everett, P., Jolesz, F. A., & Kikinis, R. (1999) · Lecture Notes in Computer Science · doi:10.1007/10704282_48 · Cited by 159
Normal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging
Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn02842 · Cited by 158
“aging ( 18 ), which was not available with our MR system at the time of this study, would have been equally insensitive to”
MethodEvidence for a vascular contribution to diffusion FMRI at high b value
Miller, K. L., Bulte, D. P., Devlin, H., Robson, M. D., Wise, R. G., Woolrich, M. W., Jezzard, P., & Behrens, T. E. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707257105 · Cited by 98
The Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2014) · Diffusion MRI · doi:10.1016/b978-0-12-396460-1.00008-1 · Cited by 66
Scattered slice shard reconstruction for motion correction in multi-shell diffusion MRI
Christiaens, D., Cordero-Grande, L., Pietsch, M., Hutter, J., Price, A. N., Hughes, E. J., Vecchiato, K., Deprez, M., Edwards, A. D., Hajnal, J. V., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117437 · Cited by 4
40 Years of diffusion MRI in the brain: From history to emerging frontiers
Le Bihan, D. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1365 · Cited by 2
“With Robert Turner and colleagues at General Electric Medical Sytems (GEMS), we showed that EPI effectively combined with IVIM and diffusion methods, setting the stage for clinical neuroimaging applications ( Turner et al., 1990).”
Metadata
- Authors
- Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J.
- Venue
- Radiology
- Published
- 1990-11
- Volume
- 177
- Issue
- 2
- Pages
- 407-414
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2088232185
- Cited by
- 581
- References
- 21
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.