Physiological properties of brain-machine interface input signals
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces (BMIs), also called brain-computer interfaces (BCIs), decode neural signals and use them to control some type of external device. Despite many experimental successes and terrific demonstrations in animals and humans, a high-performance, clinically viable device has not yet been developed for widespread usage. There are many factors that impact clinical viability and BMI performance. Arguably, the first of these is the selection of brain signals used to control BMIs. In this review, we summarize the physiological characteristics and performance—including movement-related information, longevity, and stability—of multiple types of input signals that have been used in invasive BMIs to date. These include intracortical spikes as well as field potentials obtained inside the cortex, at the surface of the cortex (electrocorticography), and at the surface of the dura mater (epidural signals). We also discuss the potential for future enhancements in input signal performance, both by improving hardware and by leveraging the knowledge of the physiological characteristics of these signals to improve decoding and stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · cited 1×
“More recent BMI studies have started using MSPs and LFPs. LFPs are the extracellular potentials that are hypothesized to be produced by the summation of local, largely postsynaptic potentials (Buzsáki et al. 2012; Mitzdorf 1985).”
BackgroundNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 3×
“…• doi:10.1152/jn.00070.2017 • www.jn.org have been employed for binary control (Kennedy et al. 2000) as well as control over cursors (Gilja et al. 2015; Hochberg et al. 2006), robotic limbs (Hochberg et al. 2012; Wodlinger et al. 2015), and functional electrical stimulation of paralyzed muscles…”
BackgroundMethodInfluentialOptimal feedback control as a theory of motor coordination
Todorov, E., & Jordan, M. I. (2002) · Nature Neuroscience · doi:10.1038/nn963 · Cited by 3,081 · cited 2×
“Although substantial evidence supporting this principle existed from behavioral studies (Latash et al. 2001; Scholz and Schöner 1999; Scott 2004; Todorov and Jordan 2002), these results were the first neural evidence of the MIP in the cortex itself (Flint et al. 2016).”
BackgroundResultReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“…brain tissue can cause shearing, which unleashes an inflammatory cytokine cascade leading to electrode encapsulation (Griffith and Humphrey 2006; Polikov et al. 2005), with subsequent increase in effective electrode impedances (McConnell et al. 2009; Roitbak and Syková 1999; Turner et al. 1999).”
BackgroundHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 2×
“…cortical activity and control the external device, which can range from cursors (Gilja et al. 2012, 2015; Hochberg et al. 2006) to robotic limbs (Collinger et al. 2013; Hochberg et al. 2012; Velliste et al. 2008) to paralyzed limb muscles (Bouton et al. 2016; Ethier et al. 2012; Pohlmeyer et…”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“More recently, the ability to record many signals simultaneously from inside the cortex has led to the development of biomimetic BMIs, that is, BMIs that are based more closely on the brain’s functioning during normal movements (Carmena et al. 2003; Fetz 2007; Serruya et al. 2002).”
BackgroundMethodOptimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746 · cited 1×
“This principle accounts for the simultaneous observation of highly accurate control of movements in a particular task with substantial trial-to-trial variability in the way the limb or body moves while achieving the task goal (Todorov 2004).”
BackgroundDissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Manning, J. R., Jacobs, J., Fried, I., & Kahana, M. J. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.2041-09.2009 · Cited by 973
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 3×
“…been employed for binary control (Kennedy et al. 2000) as well as control over cursors (Gilja et al. 2015; Hochberg et al. 2006), robotic limbs (Hochberg et al. 2012; Wodlinger et al. 2015), and functional electrical stimulation of paralyzed muscles (Ajiboye et al. 2017; Bouton et al. 2016).”
BackgroundMethodBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · cited 1×
“…been employed for binary control (Kennedy et al. 2000) as well as control over cursors (Gilja et al. 2015; Hochberg et al. 2006), robotic limbs (Hochberg et al. 2012; Wodlinger et al. 2015), and functional electrical stimulation of paralyzed muscles (Ajiboye et al. 2017; Bouton et al. 2016).”
MethodPower-Law Scaling in the Brain Surface Electric Potential
Miller, K. J., Sorensen, L. B., Ojemann, J. G., & den Nijs, M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000609 · Cited by 742
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Neural constraints on learning
Sadtler, P. T., Quick, K. M., Golub, M. D., Chase, S. M., Ryu, S. I., Tyler-Kabara, E. C., Yu, B. M., & Batista, A. P. (2014) · Nature · doi:10.1038/nature13665 · Cited by 713 · cited 1×
“Sadtler et al. (2014) also studied neural behavior during BMI learning.”
BackgroundConducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Functional organization of human sensorimotor cortex for speech articulation
Bouchard, K. E., Mesgarani, N., Johnson, K., & Chang, E. F. (2013) · Nature · doi:10.1038/nature11911 · Cited by 686 · cited 1×
“Ventral motor cortical ECoG high gamma can distinguish different speech articulator activities (Bouchard et al. 2013) and can be used to decode individual speech sounds, or phonemes (Mugler et al. 2014; Pei et al. 2011).”
BackgroundChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“These signals are obtained with the use of multielectrode arrays, most often either silicon shanks (Rousche and Normann 1998; Subbaroyan et al. 2005) or assembled from metal microwires (Nicolelis et al. 2003; Schwarz et al. 2014).”
BackgroundActive tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · cited 1×
“In addition, the implantation itself causes chronic breaching of the blood brain barrier (Kozai et al. 2015; Potter et al. 2012; Saxena et al. 2013), which can allow influx of neurotoxic serum proteins, cytokines, and pro-inflammatory cells that lead to neuronal cell death (Abbott et al. 2006;…”
BackgroundFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 2×
“Indeed, Ganguly and Carmena (2009) examined preferred directions of a highly selected set of single units in M1 during BMI use and found that they remained stable for up to 19 days when the BMI decoder was held constant (Fig.”
BackgroundWireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · cited 1×
“An alternative to avoid this issue and potentially enable much larger scale recordings is a modular system of “dust mote”-sized electrodes that can sense and transmit wirelessly to a transceiver (Seo et al. 2016).”
BackgroundMurthy, V. N., & Fetz, E. E. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.76.6.3949 · Cited by 544 · cited 1×
“The mu (8–12 Hz) and beta (12–30 Hz) bands also contain substantial movement-related information (Murthy and Fetz 1996; Sanes and Donoghue 1993), but this tends to be more useful in discriminating movement vs. rest (Williams et al. 2013) than in predicting directional information.”
BackgroundWodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536 · cited 3×
“2006), robotic limbs (Hochberg et al. 2012; Wodlinger et al. 2015), and functional electrical stimulation of paralyzed muscles (Ajiboye et al.”
BackgroundMethodBlood-brain barrier transport of cytokines: a mechanism for neuropathology
Banks, W. (2005) · Current Pharmaceutical Design · doi:10.2174/1381612053381684 · Cited by 534 · cited 1×
“…Potter et al. 2012; Saxena et al. 2013), which can allow influx of neurotoxic serum proteins, cytokines, and pro-inflammatory cells that lead to neuronal cell death (Abbott et al. 2006; Banks 2005; Biran et al. 2005; Hassel et al. 1994; Liu et al. 1999; Matz et al. 2001; Winslow and Tresco 2010).”
BackgroundSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
The thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · cited 1×
“…(Otto et al. 2006), or changes to the nanostructure or coatings of the electrode shanks, which promise to reduce the foreign body response (Grill et al. 2009; He et al. 2006; Kotov et al. 2009; Kozai et al. 2012; Sommakia et al. 2014); and using neu- J Neurophysiol •…”
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485 · cited 3×
“…intact animals: to control cursors (Carmena et al. 2003; Gilja et al. 2012; Serruya et al. 2002; Taylor et al. 2002), robotic limbs (Velliste et al. 2008; Wessberg et al. 2000), and functional electrical stimulation of (temporarily) paralyzed muscles (Ethier et al. 2012; Pohlmeyer et al. 2009).”
BackgroundDeep brain stimulation for treatment-resistant depression: follow-up after 3 to 6 years
Kennedy, S. H., Giacobbe, P., Rizvi, S. J., Placenza, F. M., Nishikawa, Y., Mayberg, H. S., & Lozano, A. M. (2011) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2010.10081187 · Cited by 481
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368 · cited 1×
“…potentials (Cheng et al. 2002; Donchin et al. 2000; Wang et al. 2006), “passive” BMIs (Zander and Kothe 2011) that do not attempt direct control, and sensory/afferent BMIs (Bensmaia and Miller 2014; London et al. 2008; O’Doherty et al. 2011; see also Lebedev 2014 for a review of BMI categories).”
BackgroundSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · cited 1×
“These signals are obtained with the use of multielectrode arrays, most often either silicon shanks (Rousche and Normann 1998; Subbaroyan et al. 2005) or assembled from metal microwires (Nicolelis et al. 2003; Schwarz et al. 2014).”
BackgroundClinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343 · cited 4×
“…in humans have successfully used high-gamma activity plus higher frequency activity (over 300 Hz, what some refer to as “hash”) to control BMIs with high performance even after J Neurophysiol • doi:10.1152/jn.00070.2017 • www.jn.org spikes could no longer be recorded (Gilja et al. 2015).”
BackgroundMethodInfluentialJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298 · cited 1×
“Spike recording longevity is also impaired by neuronal loss from the inflammatory cascade (Biran et al. 2005), as well as mechanical degradation such as insulation breakdown (Barrese et al. 2013) and electrode breakage (Prasad et al. 2012).”
BackgroundBrain-to-text: decoding spoken phrases from phone representations in the brain
Herff, C., Heger, D., de Pesters, A., Telaar, D., Brunner, P., Schalk, G., & Schultz, T. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00217 · Cited by 297 · cited 1×
“Indeed, ECoG has been shown to classify small sets of words (Herff et al. 2015; Kellis et al. 2010) with modest accuracy.”
BackgroundFast and Slow Oscillations in Human Primary Motor Cortex Predict Oncoming Behaviorally Relevant Cues
Saleh, M., Reimer, J., Penn, R., Ojakangas, C. L., & Hatsopoulos, N. G. (2010) · Neuron · doi:10.1016/j.neuron.2010.02.001 · Cited by 281 · cited 1×
“There is a considerable amount of information in the phase of the delta band (Saleh et al. 2010), which likely explains why we found more information in the LMP (which retains time domain information) than in delta-band power (Flint et al. 2012a, 2012b).”
BackgroundElectrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 1×
“…has been used to control cursors, using biofeedback (Bundy et al. 2012; Leuthardt et al. 2004; Miller et al. 2010; Schalk et al. 2008), biomimetic (Milekovic et al. 2012), and hybrid/adaptive BMIs (Wang et al. 2013), and robotic hands and arms (Hotson et al. 2016; Yanagisawa et al. 2011, 2012).”
MethodPei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237 · cited 1×
“Ventral motor cortical ECoG high gamma can distinguish different speech articulator activities (Bouchard et al. 2013) and can be used to decode individual speech sounds, or phonemes (Mugler et al. 2014; Pei et al. 2011).”
BackgroundDecoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235 · cited 2×
“Indeed, ECoG has been shown to classify small sets of words (Herff et al. 2015; Kellis et al. 2010) with modest accuracy.”
BackgroundSingle-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234 · cited 1×
“For spikes, one definition is the waveform characteristics of the spikes themselves (Chestek et al. 2011; Dickey et al. 2009).”
BackgroundAn Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218 · cited 1×
“…the tethering of the array to the skull (i.e., making the device completely implanted and wireless (Borton et al. 2013; Kennedy et al. 2000; Sodagar et al. 2009); reducing inflammation using anti-inflammatory drugs (Shain et al. 2003; Zhong and Bellamkonda 2007), electrical stimulation…”
BackgroundReal-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208 · cited 1×
“…has been used to control cursors, using biofeedback (Bundy et al. 2012; Leuthardt et al. 2004; Miller et al. 2010; Schalk et al. 2008), biomimetic (Milekovic et al. 2012), and hybrid/adaptive BMIs (Wang et al. 2013), and robotic hands and arms (Hotson et al. 2016; Yanagisawa et al. 2011, 2012).”
MethodChronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204 · cited 2×
“These include reducing the mechanical stiffness of the electrodes including using carbon nanofibers (Kozai et al. 2012; Patel et al. 2016) or polymers (Hara et al. 2016; Ware et al. 2014); reducing shear forces by eliminating the tethering of the array to the skull (i.e., making the device…”
BackgroundHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201 · cited 1×
“…has been used to control cursors, using biofeedback (Bundy et al. 2012; Leuthardt et al. 2004; Miller et al. 2010; Schalk et al. 2008), biomimetic (Milekovic et al. 2012), and hybrid/adaptive BMIs (Wang et al. 2013), and robotic hands and arms (Hotson et al. 2016; Yanagisawa et al. 2011, 2012).”
MethodMugler, E. M., Patton, J. L., Flint, R. D., Wright, Z. A., Schuele, S. U., Rosenow, J., Shih, J. J., Krusienski, D. J., & Slutzky, M. W. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035015 · Cited by 192 · cited 1×
“Ventral motor cortical ECoG high gamma can distinguish different speech articulator activities (Bouchard et al. 2013) and can be used to decode individual speech sounds, or phonemes (Mugler et al. 2014; Pei et al. 2011).”
BackgroundSelf-citationHe, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177 · cited 1×
“…2006), or changes to the nanostructure or coatings of the electrode shanks, which promise to reduce the foreign body response (Grill et al. 2009; He et al. 2006; Kotov et al. 2009; Kozai et al. 2012; Sommakia et al. 2014); and using neu- J Neurophysiol • doi:10.1152/jn.00070.2017 •…”
BackgroundInfluentialDistributed cortical adaptation during learning of a brain–computer interface task
Wander, J. D., Blakely, T., Miller, K. J., Weaver, K. E., Johnson, L. A., Olson, J. D., Fetz, E. E., Rao, R. P. N., & Ojemann, J. G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221127110 · Cited by 157
Brain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112
Optimizing the Decoding of Movement Goals from Local Field Potentials in Macaque Cortex
Markowitz, D. A., Wong, Y. T., Gray, C. M., & Pesaran, B. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4165-11.2011 · Cited by 110
The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
Real-time estimation and biofeedback of single-neuron firing rates using local field potentials
Hall, T. M., Nazarpour, K., & Jackson, A. (2014) · Nature Communications · doi:10.1038/ncomms6462 · Cited by 61 · cited 2×
“Finally, Hall et al. (2014) devised an approach to estimating spiking rates from LFPs recorded in the area, which could provide more stable “inferred” spiking to use in BMIs.”
BackgroundMethod
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Speech synthesis from ECoG using densely connected 3D convolutional neural networks
Angrick, M., Herff, C., Mugler, E., Tate, M. C., Slutzky, M. W., Krusienski, D. J., & Schultz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0c59 · Cited by 225
“Invasivelymeasured brain activity, such as ECoG is particularly well-suited for the decoding of speech processes [8, 9, 10, 11], as it balances a very high spatial and temporal resolution with broad coverage of the cortex.”
BackgroundSelf-citationIntracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Robust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
Metadata
- Authors
- Slutzky, M. W., & Flint, R. D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2017-08-01
- Volume
- 118
- Issue
- 2
- Pages
- 1329-1343
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2626218520
- Cited by
- 46
- References
- 61
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.