CoChat

Tissue Doppler Echocardiographic Evidence of Reverse Remodeling and Improved Synchronicity by Simultaneously Delaying Regional Contraction After Biventricular Pacing Therapy in Heart Failure

Open access
Yu, Cheuk-Man, Chau, Elaine, Sanderson, John E., Fan, Katherine, Tang, Man-Oi, Fung, Wing-Hong, Lin, Hong, Kong, Shun-Ling, Lam, Yui-Ming, Hill, Michael R.S., Lau, Chu-Pak · 2002 · Circulation
Cited by 1,110

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background — Biventricular pacing has been proposed to improve symptoms and exercise capacity in patients with advanced heart failure and wide electrocardiographic wave complexes. This study investigated the effect of biventricular pacing on reverse remodeling and the underlying mechanisms. Methods and Results — Twenty-five patients with NYHA class III to IV heart failure and electrocardiographic wave complex duration >140 ms receiving biventricular pacing therapy were assessed serially up to 3 months after pacing and when pacing was withheld for 4 weeks. Tissue Doppler echocardiography was performed using a 6-basal, 6-mid segmental model to assess the time to peak sustained systolic contraction (T S ). There was significant improvement of ejection fraction, dP/dt, and myocardial performance index; decrease in mitral regurgitation, left ventricular (LV) end-diastolic (205±68 versus 168±67 mL, P <0.01) and end-systolic volume (162±54 versus 122±42 mL, P <0.01); and improved 6-minute hall-walk distance and quality of life score after pacing for 3 months. The mechanisms of benefits were as follows: (1) improved LV synchrony, as evident by homogeneous delay of T S to a timing close to the latest (usually the lateral) segment abolishing the intersegmental difference in T S and decreasing the standard deviation of T S within the left ventricle (37.7±10.9 versus 29.3±8.3 ms, P <0.05); (2) improved interventricular synchrony; and (3) shortened isovolumic contraction time (122±57 versus 82±36 ms, P <0.05) but increased diastolic filling time. These benefits are pacing dependent, because withholding the pacing resulted in varying speeds in the loss of cardiac improvements. Conclusions — Biventricular pacing reverses LV remodeling and improves cardiac function. Improvement of LV mechanical synchrony seems to be the predominant mechanism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc0402.102623

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Yu, C.-M., Chau, E., Sanderson, J. E., Fan, K., Tang, M.-O., Fung, W.-H., Lin, H., Kong, S.-L., Lam, Y.-M., Hill, M. R. S., & Lau, C.-P.
Venue
Circulation
Published
2002-01-29
Volume
105
Issue
4
Pages
438-445
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2170281616
Cited by
1,110
References
16
FWCI
57.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.