Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials: Recommendations from the International HOVER Taskforce
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Translational research in vision prosthetics, gene therapy, optogenetics, stem cell and other forms of transplantation, and sensory substitution is creating new therapeutic options for patients with neural forms of blindness. The technical challenges faced by each of these disciplines differ considerably, but they all face the same challenge of how to assess vision in patients with ultra-low vision (ULV), who will be the earliest subjects to receive new therapies. Historically, there were few tests to assess vision in ULV patients. In the 1990s, the field of visual prosthetics expanded rapidly, and this activity led to a heightened need to develop better tests to quantify end points for clinical studies. Each group tended to develop novel tests, which made it difficult to compare outcomes across groups. The common lack of validation of the tests and the variable use of controls added to the challenge of interpreting the outcomes of these clinical studies. In 2014, at the bi-annual International "Eye and the Chip" meeting of experts in the field of visual prosthetics, a group of interested leaders agreed to work cooperatively to develop the International Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials (HOVER) Taskforce. Under this banner, more than 80 specialists across seven topic areas joined an effort to formulate guidelines for performing and reporting psychophysical tests in humans who participate in clinical trials for visual restoration. This document provides the complete version of the consensus opinions from the HOVER taskforce, which, together with its rules of governance, will be posted on the website of the Henry Ford Department of Ophthalmology (www.artificialvision.org). Research groups or companies that choose to follow these guidelines are encouraged to include a specific statement to that effect in their communications to the public. The Executive Committee of the HOVER Taskforce will maintain a list of all human psychophysical research in the relevant fields of research on the same website to provide an overview of methods and outcomes of all clinical work being performed in an attempt to restore vision to the blind. This website will also specify which scientific publications contain the statement of certification. The website will be updated every 2 years and continue to exist as a living document of worldwide efforts to restore vision to the blind. The HOVER consensus document has been written by over 80 of the world's experts in vision restoration and low vision and provides recommendations on the measurement and reporting of patient outcomes in vision restoration trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Biomedical Ethics
(2012) · Thieves of Virtue · doi:10.7551/mitpress/9079.003.0009 · Cited by 13,453
Development of the 25-list-item National Eye Institute Visual Function Questionnaire
Mangione, C. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.1050 · Cited by 2,230
Effect of gene therapy on visual function in Leber’s congenital amaurosis
Bainbridge, J. W. B., Smith, A. J., Barker, S. S., Robbie, S., Henderson, R., Balaggan, K., Viswanathan, A., Holder, G. E., Stockman, A., Tyler, N., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0802268 · Cited by 1,924
Self-citationThe sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 4×
“This finding highlights two important applications of the VEP, whether elicited electrically or with light stimuli: (1) to objectively demonstrate integrity of the visual pathway from retinal ganglion cells to primary visual cortex, and (2) to differentiate between retinal origins of the response and thus show integri…”
BackgroundMethodInfluentialVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Long-Term Effect of Gene Therapy on Leber’s Congenital Amaurosis
Bainbridge, J. W. B., Mehat, M. S., Sundaram, V., Robbie, S. J., Barker, S. E., Ripamonti, C., Georgiadis, A., Mowat, F. M., Beattie, S. G., Gardner, P. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414221 · Cited by 743
Self-citationInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationISCEV standard for clinical visual evoked potentials: (2016 update)
International Society for Clinical Electrophysiology of Vision, Odom, J. V., Bach, M., Brigell, M., Holder, G. E., McCulloch, D. L., Mizota, A., & Tormene, A. P. (2016) · Documenta Ophthalmologica · doi:10.1007/s10633-016-9553-y · Cited by 699
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Self-citationNanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107
Beyeler, M., Rokem, A., Boynton, G. M., & Fine, I. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa795e · Cited by 102
Spatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95
Psychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
Self-citationFactors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Self-citationFLORA™: phase I development of a functional vision assessment for prosthetic vision users
Geruschat, D. R., Flax, M., Tanna, N., Bianchi, M., Fisher, A., Goldschmidt, M., Fisher, L., Dagnelie, G., Deremeik, J., Smith, A., et al. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12242 · Cited by 75
Self-citationRetinal prosthesis phosphene shape analysis
Nanduri, D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., & Weiland, J. D. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649524 · Cited by 74
Virtual electrodes by current steering in retinal prostheses
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15391 · Cited by 63
Fine, I., & Boynton, G. M. (2015) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2014.0208 · Cited by 55
Mobility and low contrast trip hazard avoidance using augmented depth
McCarthy, C., Walker, J. G., Lieby, P., Scott, A., & Barnes, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016003 · Cited by 49
Self-citationTemporal interactions during paired-electrode stimulation in two retinal prosthesis subjects
Horsager, A., Boynton, G. M., Greenberg, R. J., & Fine, I. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5282 · Cited by 48
Sabbah, N., Authie, C. N., Sanda, N., Mohand-Said, S., Sahel, J.-A., & Safran, A. B. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15392 · Cited by 45
Retinotopic to spatiotopic mapping in blind patients implanted with the Argus II retinal prosthesis
Caspi, A., Roy, A., Dorn, J. D., & Greenberg, R. J. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20398 · Cited by 32
Orientation and mobility assessment in retinal prosthetic clinical trials
Geruschat, D. R., Bittner, A. K., & Dagnelie, G. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182686251 · Cited by 31
Self-citationSemantic labeling for prosthetic vision
Horne, L., Alvarez, J., McCarthy, C., Salzmann, M., & Barnes, N. (2016) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2016.02.015 · Cited by 30
Self-citationYan, Y., Lu, Y., Li, M., Ma, Z., Cao, P., Chen, Y., Sun, X., Chai, X., Ren, Q., & Li, L. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17543 · Cited by 20
Cited by
Erickson-Davis, C., & Korzybska, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0229189 · Cited by 83
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79
A Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis: Interim Clinical Trial Results
Petoe, M. A., Titchener, S. A., Kolic, M., Kentler, W. G., Abbott, C. J., Nayagam, D. A. X., Baglin, E. K., Kvansakul, J., Barnes, N., Walker, J. G., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.12 · Cited by 63
Self-citationKarapanos, L., Abbott, C. J., Ayton, L. N., Kolic, M., McGuinness, M. B., Baglin, E. K., Titchener, S. A., Kvansakul, J., Johnson, D., Kentler, W. G., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.7 · Cited by 30
Self-citationRetinal prostheses: where to from here?
Allen, P. J. (2021) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13950 · Cited by 20
Metadata
- Authors
- Ayton, L. N., Rizzo, J. F., Bailey, I. L., Colenbrander, A., Dagnelie, G., Geruschat, D. R., Hessburg, P. C., McCarthy, C. D., Petoe, M. A., Rubin, G. S., Troyk, P. R., & Taskforce, F. T. H. I.
- Venue
- Translational Vision Science & Technology
- Published
- 2020-07-16
- Volume
- 9
- Issue
- 8
- Pages
- 25
- ISSN
- 2164-2591 (ISSN-L)
- OpenAlex
- W3043005701
- Cited by
- 74
- References
- 31
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.