Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—Hypoglycemia and wide glucose excursions continue to be major obstacles to achieving target HbA1c values and the associated reductions in long-term complications (and economic costs) in people with insulin-treated diabetes. In this study we evaluated the accuracy, safety, and clinical effectiveness of a continuous glucose-sensing device. RESEARCH DESIGN AND METHODS—A total of 91 insulin-requiring patients with type 1 (n = 75) and type 2 (n = 16) diabetes were enrolled in this multicenter randomized study. Subjects wore a transcutaneous, 3-day, continuous glucose-sensing system for three consecutive 72-h periods. Subjects were randomly assigned (1:1 ratio) to either a control group (continuous glucose data not provided) or a display group (continuous glucose data not provided during period 1 but displayed during periods 2 and 3). During periods 2 and 3, patients in the display group had real-time access to sensor glucose values, could review glucose trends over the preceding 1, 3, and 9 h, and were provided with high (≥200 mg/dl) and low (≤80 mg/dl) alerts and a low (≤55 mg/dl) alarm. Sensors were inserted by patients, and both groups used (or wore) the system during daily activities. Device accuracy was assessed by comparing continuous glucose values to paired self-monitoring of blood glucose (SMBG) meter readings. Clinical effectiveness was evaluated by analyzing between-group (control vs. display, periods 2 and 3) and within-group (display, period 1 vs. period 3) differences in time spent in high, low, and target (81–140 mg/dl) glucose zones. RESULTS—When prospective, real-time sensor values were compared with SMBG values, 95.4% of 6,767 paired glucose values fell within Clarke error grid A and B zones. Pearson’s correlation coefficient was 0.88, and mean and median absolute relative differences were 21.2 and 15.9%, respectively. No systematic bias was detected at any of the prespecified glucose levels (50, 80, 100, 150, and 200 mg/dl). When compared with control subjects, the display group spent 21% less time as hypoglycemic (<55 mg/dl), 23% less time as hyperglycemic (≥240 mg/dl), and 26% more time in the target (81–140 mg/dl) glucose range (P < 0.001 for each comparison). Nocturnal (10:00 p.m. to 6:00 a.m.) hypoglycemia, as assessed at two thresholds, was also reduced by 38% (<55 mg/dl; P < 0.001) and 33% (55–80 mg/dl; P < 0.001) in the display group compared with control subjects. CONCLUSIONS—We conclude that real-time continuous glucose monitoring for periods up to 72 h is accurate and safe in insulin-requiring subjects with type 1 and type 2 diabetes. This study demonstrates that availability of real-time, continuously measured glucose levels can significantly improve glycemic excursions by reducing exposure to hyperglycemia without increasing the risk of hypoglycemia, which may reduce long-term diabetes complications and their associated economic costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Statistical adjustment of data
Deming, W. E. (1984) · Cited by 419
Should minimal blood glucose variability become the gold standard of glycemic control?
Hirsch, I. B., & Brownlee, M. (2005) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2004.10.001 · Cited by 405
Garg, S. K., Schwartz, S., & Edelman, S. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.3.734 · Cited by 161
Self-citation
Research works printed but not linked: 1
- Nathan DM: Effect of intensive diabetes management on cardiovascular events in type 1 diabetes. In Proceedings of the 65th Annual Scientific Sessions of the American Diabetes Association, San Diego, CA, 10–14 June 2005. Alexandria, VA, American Diabetes Association, 2005
Cited by
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
Standards of Medical Care in Diabetes—2008
American Diabetes Association (2008) · Diabetes Care · doi:10.2337/dc08-s012 · Cited by 1,377
“Small studies in selected patient populations have shown good correlation of readings with SMBG and decreases in the mean time spent in hypo- and hyperglycemic ranges compared with blinded sensor use (30).”
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
“The clinical studies of these devices, generally in highly selected populations, had primarily been limited to assessments of their accuracy or to short-term trials demonstrating reductions in the time patients spend within hypo- and hyperglycemic intervals (148).”
Cryer, P. E., Axelrod, L., Grossman, A. B., Heller, S. R., Montori, V. M., Seaquist, E. R., & Service, F. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1410 · Cited by 1,277
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Hod, M., Kapur, A., Sacks, D. A., Hadar, E., Agarwal, M., Di Renzo, G. C., Roura, L. C., McIntyre, H. D., Morris, J. L., & Divakar, H. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(15)30033-3 · Cited by 767
“In the overall cost of providing care to women with GDM the cost of administering a glucose tolerance test (GTT) to all pregnant women is likely to be minimal if the initial fasting GTT level result can be used to decide if the full GTT is needed [18,19].”
BackgroundIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
6. Glycemic Targets: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s006 · Cited by 744
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
“The clinical studies of these devices, generally in highly selected populations, had primarily been limited to assessments of their accuracy or to short-term trials demonstrating reductions in the time patients spend within hypo- and hyperglycemic intervals (148).”
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
“Graduate/professional degree 14 (18) 8 (11) Mean BMI (SD), kg/m(2) 35 (8) 37 (7) Mean weight (SD), kg 98 (23) 105 (25)”
DiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Weinzimer, S. A., Steil, G. M., Swan, K. L., Dziura, J., Kurtz, N., & Tamborlane, W. V. (2008) · Diabetes Care · doi:10.2337/dc07-1967 · Cited by 567
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M., Pihoker, C., Donaghue, K., Hanas, R., Swift, P., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00582.x · Cited by 342
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M. J., Pillay, K., de Beaufort, C., Craig, M. E., Hanas, R., Acerini, C. L., & Maahs, D. M. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12190 · Cited by 316
Rodbard, D. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0132 · Cited by 310
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
The Evidence for Medical Nutrition Therapy for Type 1 and Type 2 Diabetes in Adults
Franz, M. J., Powers, M. A., Leontos, C., Holzmeister, L. A., Kulkarni, K., Monk, A., Wedel, N., & Gradwell, E. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.09.014 · Cited by 306
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244
Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2017) · Electronics · doi:10.3390/electronics6030065 · Cited by 237
“Use of CGM sensor is recognized to be not only clinically beneficial for T1D glycaemic control [75,76], but also cost ‐ effective in the long term [77,78], despite the fact that only 10% of T1D patients are currently using this technology [79]. also cost-effective in the long term [77,78], despite…”
BackgroundAssessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
Tanenberg, R. J., Newton, C. A., & Drake, A. J. (2010) · Endocrine Practice · doi:10.4158/ep09260.cr · Cited by 225
Guideline for management of postmeal glucose
Ceriello, A., Colagiuri, S., Gerich, J., & Tuomilehto, J. (2008) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2008.01.012 · Cited by 213
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211
“Studies assessing their use have shown improvement in HbA1c [7–11], increased time spent in the target glucose range [11, 12] and fewer hypo- and hyperglycaemic excursions [9, 13], suggesting the potential for important clinical benefits.”
BackgroundKilpatrick, E. S., Rigby, A. S., Goode, K., & Atkin, S. L. (2007) · Diabetologia · doi:10.1007/s00125-007-0820-z · Cited by 209
“Continued development of continuous glucose monitoring systems [38] has shown great potential in reducing glycaemic excursions [39] as well as exposing many limitations of conventional self-monitoring of blood glucose [40].”
Background1,5-anhydroglucitol (GlycoMark™) as a marker of short-term glycemic control and glycemic excursions
Dungan, K. M. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.1.9 · Cited by 207
Mechanisms of hypoglycemia unawareness and implications in diabetic patients
Martín-Timón, I. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i7.912 · Cited by 204
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199
Delays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198
Mazze, R. S., Strock, E., Wesley, D., Borgman, S., Morgan, B., Bergenstal, R., & Cuddihy, R. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0293 · Cited by 182
Function of an Implanted Tissue Glucose Sensor for More than 1 Year in Animals
Gough, D. A., Kumosa, L. S., Routh, T. L., Lin, J. T., & Lucisano, J. Y. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001148 · Cited by 179
7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Zecchin, C., Facchinetti, A., Sparacino, G., De Nicolao, G., & Cobelli, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188893 · Cited by 178
Freckmann, G., Hagenlocher, S., Baumstark, A., Jendrike, N., Gillen, R. C., Rössner, K., & Haug, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100513 · Cited by 174
Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors
Breton, M., & Kovatchev, B. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200517 · Cited by 173
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
RSSDI-ESI clinical practice recommendations for the management of type 2 diabetes mellitus 2020
Madhu, S., Chawla, R., Makkar, B., Ghosh, S., Saboo, B., & Kalra, S. (2020) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_225_20 · Cited by 167
“have demonstrated an improvement on glycaemic excursion in insulin-treated T2DM patients using Real time-CGM, showing a significant reduction of the time spent in hypo- and hyper-glycaemic range with an increased time spent in the target glucose range as well as a significant reduction of nocturnal hypoglycaemia in th…”
MethodBergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700234 · Cited by 166
Self-citationBailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Self-citationContinuous Glucose Monitoring: Review of an Innovation in Diabetes Management
Mian, Z., Hermayer, K. L., & Jenkins, A. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.07.003 · Cited by 139
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
Blevins, T. C., Bode, B. W., Garg, S. K., Grunberger, G., Hirsch, I. B., Jovanovič, L., Nardacci, E., Orzeck, E. A., Roberts, V. L., & Tamborlane, W. V. (2010) · Endocrine Practice · doi:10.4158/ep.16.5.730 · Cited by 98
Self-citationContinuous glucose monitoring: Current use in diabetes management and possible future applications
Vettoretti, M., Cappon, G., Acciaroli, G., Facchinetti, A., & Sparacino, G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818774078 · Cited by 96
Cichosz, S. L., Frystyk, J., Hejlesen, O. K., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528838 · Cited by 88
“CGM has been used in several applications as hypoglycemia alarms and it has been shown to reduce the incidence.(35) This comes with a trade-off partly because of the 10-minute lag time from changes in blood glucose and partly because of poor accuracy of the CGM systems in measuring glucose values within the hypoglycem…”
MethodFreckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Garg, S. K., Voelmle, M. K., Beatson, C. R., Miller, H. A., Crew, L. B., Freson, B. J., & Hazenfield, R. M. (2011) · Diabetes Care · doi:10.2337/dc10-1852 · Cited by 85
“Furthermore, CGM use has been reported in both controlled (6–8) and nonrandomized trials (9–12) to improve glucose control, reduce hypo- and hyperglycemic excursions (10,11), and improve glucose variability (13,14).”
Self-citationThe Cost-Effectiveness of Real-Time Continuous Glucose Monitoring (RT-CGM) in Type 2 Diabetes
Fonda, S. J., Graham, C., Munakata, J., Powers, J. M., Price, D., & Vigersky, R. A. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816628547 · Cited by 81
Price, D. A., Deng, Q., Kipnes, M., & Beck, S. E. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01086-y · Cited by 77
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71
Joubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70
Minimizing Glycemic Fluctuations in Patients with Type 2 Diabetes: Approaches and Importance
Dandona, P. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0372 · Cited by 67
Use of Mobile Health Technology in the Prevention and Management of Diabetes Mellitus
Hartz, J., Yingling, L., & Powell-Wiley, T. M. (2016) · Current Cardiology Reports · doi:10.1007/s11886-016-0796-8 · Cited by 64
Improved Real-World Glycemic Control With Continuous Glucose Monitoring System Predictive Alerts
Abraham, S. B., Arunachalam, S., Zhong, A., Agrawal, P., Cohen, O., & McMahon, C. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819859334 · Cited by 63
Hermanns, N., Schumann, B., Kulzer, B., & Haak, T. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814524105 · Cited by 39
“There is convincing evidence that the use of CGM is capable of reducing exposure to hypoglycemic glucose values measured in the interstitial fluid.(1,3,14,15) However, these results mainly rely on the CGM glucose measurement itself.”
MethodKlueh, U., Kaur, M., Montrose, D. C., & Kreutzer, D. L. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100407 · Cited by 33
“In the case of these types of coatings it has been found that (1) generally only “analytepermeable coatings” can be used as sensor coatings, thus limiting the type of coating available for implantable sensors; (2) binding of sufficient quantities of bioactive agents, such as peptides and proteins, can be difficult and…”
BackgroundBajgrowicz-Cieslak, M., Alqurashi, Y., Elshereif, M. I., Yetisen, A. K., Hassan, M. U., & Butt, H. (2017) · RSC Advances · doi:10.1039/c7ra11184c · Cited by 32
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Kasthuri, S., Poongothai, S., Anjana, R. M., Selvakumar, J., Muthukumar, S., Kayalvizhi, S., Tariq, S., Honey, E., Gupta, P. K., Venkatesan, U., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0484 · Cited by 13
Schechter, A., Eyal, O., Zuckerman-Levin, N., Amihai-Ben-Yaacov, V., Weintrob, N., & Shehadeh, N. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0002 · Cited by 12
Evaluation of a continuous glucose monitoring system in healthy dairy calves and adult goats
Brobst, M. N., Abi-Nader, B. A., Blasczynski, S. J., & Chigerwe, M. (2024) · American Journal of Veterinary Research · doi:10.2460/ajvr.24.03.0076 · Cited by 6
Metadata
- Authors
- Garg, S., Zisser, H., Schwartz, S., Bailey, T., Kaplan, R., Ellis, S., & Jovanovic, L.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2006-01-01
- Volume
- 29
- Issue
- 1
- Pages
- 44-50
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2074414391
- Cited by
- 433
- References
- 12
- FWCI
- 30.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.