The DOI matches its Crossref record; 79 of the 79 references it cites were found in a registry or an index.
Multifunctional Nanobiomaterials for Neural Interfaces
Open accessAbstract
Neural electrodes are designed to interface with the nervous system and provide control signals for neural prostheses. However, robust and reliable chronic recording and stimulation remains a challenge for neural electrodes. Here, a novel method for the fabrication of soft, low impedance, high charge density, and controlled releasing nanobiomaterials that can be used for the surface modification of neural microelectrodes to stabilize the electrode/tissue interface is reported. The fabrication process includes electrospinning of anti‐inflammatory drug‐incorporated biodegradable nanofibers, encapsulation of these nanofibers by an alginate hydrogel layer, followed by electrochemical polymerization of conducting polymers around the electrospun drug‐loaded nanofibers to form nanotubes and within the alginate hydrogel scaffold to form cloud‐like nanostructures. The three‐dimensional conducting polymer nanostructures significantly decrease the electrode impedance and increase the charge capacity density. Dexamethasone release profiles show that the alginate hydrogel coating slows down the release of the drug, significantly reducing the burst effect. These multifunctional materials are expected to be of interest for a variety of electrode/tissue interfaces in biomedical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Poly(3,4-ethylenedioxythiophene) and Its Derivatives: Past, Present, and Future
Groenendaal, L., Jonas, F., Freitag, D., Pielartzik, H., & Reynolds, J. R. (2000) · Advanced Materials · doi:10.1002/(sici)1521-4095(200004)12:7<481::aid-adma481>3.0.co;2-c · Cited by 3,420
Biodegradable nanoparticles for drug and gene delivery to cells and tissue
Panyam, J., & Labhasetwar, V. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00228-4 · Cited by 3,361
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Electrospun nanofibrous structure: A novel scaffold for tissue engineering
Li, W., Laurencin, C. T., Caterson, E. J., Tuan, R. S., & Ko, F. K. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10167 · Cited by 2,427
Jain, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00115-0 · Cited by 2,214
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Polymeric system for dual growth factor delivery
Richardson, T. P., Peters, M. C., Ennett, A. B., & Mooney, D. J. (2001) · Nature Biotechnology · doi:10.1038/nbt1101-1029 · Cited by 1,752
Protein release from alginate matrices
Gombotz, W. R., & Wee, S. F. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.007 · Cited by 1,609
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Protein release from alginate matrices
Gombotz, W. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00124-5 · Cited by 1,550
Nanostructured Fibers via Electrospinning
Bognitzki, M., Czado, W., Frese, T., Schaper, A., Hellwig, M., Steinhart, M., Greiner, A., & Wendorff, J. H. (2001) · Advanced Materials · doi:10.1002/1521-4095(200101)13:1<70::aid-adma70>3.0.co;2-h · Cited by 1,236
Conjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177
Why degradable polymers undergo surface erosion or bulk erosion
Burkersroda, F. V., Schedl, L., & Göpferich, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00170-9 · Cited by 1,146
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Electrochemistry of Poly(3,4‐alkylenedioxythiophene) Derivatives
Groenendaal, L., Zotti, G., Aubert, P. ‐., Waybright, S. M., & Reynolds, J. R. (2003) · Advanced Materials · doi:10.1002/adma.200300376 · Cited by 944
Systemic Adverse Effects of Inhaled Corticosteroid Therapy: A Systematic Review and Meta-analysis
Lipworth, B. J. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.9.941 · Cited by 918
Conducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Self-citationCrystal structure, conformation and morphology of solution-spun poly(L-lactide) fibers
Hoogsteen, W., Postema, A. R., Pennings, A. J., Ten Brinke, G., & Zugenmaier, P. (1990) · Macromolecules · doi:10.1021/ma00204a041 · Cited by 864
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Biodegradable polymers as drug delivery systems
(1992) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(92)90663-b · Cited by 779
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Hydrogels: Swelling, Drug Loading, and Release
Kim, S. W., Bae, Y. H., & Okano, T. (1992) · Pharmaceutical Research · doi:10.1023/a:1015887213431 · Cited by 656
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationBerggren, M., & Richter‐Dahlfors, A. (2007) · Advanced Materials · doi:10.1002/adma.200700419 · Cited by 630
Electrochemical and spectroscopic characterization of polyalkylenedioxythiophenes
Dietrich, M., Heinze, J., Heywang, G., & Jonas, F. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(94)87085-3 · Cited by 617
Pulsatile drug release control using hydrogels
Kikuchi, A., & Okano, T. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00243-5 · Cited by 600
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Kim, K., Yu, M., Zong, X., Chiu, J., Fang, D., Seo, Y.-S., Hsiao, B. S., Chu, B., & Hadjiargyrou, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00407-1 · Cited by 562
Biodegradable polymers as drug delivery systems
(1991) · European Journal of Medicinal Chemistry · doi:10.1016/0223-5234(91)90162-g · Cited by 514
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Reed, A. M., & Gilding, D. K. (1981) · Polymer · doi:10.1016/0032-3861(81)90168-3 · Cited by 502
Li, S., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00701077 · Cited by 488
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
Selection of stimulus parameters for deep brain stimulation
Kuncel, A. M., & Grill, W. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.05.031 · Cited by 458
Dunne, M., Corrigan, O. I., & Ramtoola, Z. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00040-5 · Cited by 444
Electronic control of Ca2+ signalling in neuronal cells using an organic electronic ion pump
Isaksson, J., Kjäll, P., Nilsson, D., Robinson, N., Berggren, M., & Richter-Dahlfors, A. (2007) · Nature Materials · doi:10.1038/nmat1963 · Cited by 418
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700872 · Cited by 383
Conductive modifications of polymers with polypyrroles and polythiophenes
Jonas, F., & Schrader, L. (1991) · Synthetic Metals · doi:10.1016/0379-6779(91)91506-6 · Cited by 382
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Erosion kinetics of hydrolytically degradable polymers.
Tamada, J. A., & Langer, R. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.2.552 · Cited by 356
Abidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 338
Self-citationCui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 330
Self-citationPhysico-chemical characterization of Ca-alginate microparticles produced with different methods
Fundueanu, G., Nastruzzi, C., Carpov, A., Desbrieres, J., & Rinaudo, M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00050-2 · Cited by 318
Further investigations on the hydrolytic degradation of poly (DL-lactide)
Li, S., & McCarthy, S. (1999) · Biomaterials · doi:10.1016/s0142-9612(97)00226-3 · Cited by 301
Zong, X., Ran, S., Kim, K.-S., Fang, D., Hsiao, B. S., & Chu, B. (2003) · Biomacromolecules · doi:10.1021/bm025717o · Cited by 265
Preparation of biodegradable microspheres and microcapsules: 2. Polyactides and related polyesters
Arshady, R. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90126-x · Cited by 258
Medical Applications of Controlled Release: Applications and Evaluation
(2019) · CRC Press eBooks · doi:10.1201/9780429276620 · Cited by 251
Shain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
MELBY, J. C. (1974) · Annals of Internal Medicine · doi:10.7326/0003-4819-81-4-505 · Cited by 222
Park, T. G., Cohen, S., & Langer, R. (1992) · Macromolecules · doi:10.1021/ma00027a019 · Cited by 221
Spataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Enabling Technologies for Cultured Neural Networks
Stenger, D. A., & McKenna, T. M. (1994) · Cited by 214
Polyimide-based intracortical neural implant with improved structural stiffness
Lee, K.-K., He, J., Singh, A., Massia, S., Ehteshami, G., Kim, B., & Raupp, G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/305 · Cited by 161
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160
Self-citationSputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138 · cited 1×
“These strategies include: i) optimizing the size,([10]) shape,([8,12]) tip geometry,([10]) texture,([10,13]) material substrate, and insertion procedures([10,12,16,17]) to minimize the initial trauma to the brain tissue during implantation; ii) deposition of metals([18]) and metal oxides([19]) on the surface of electr…”
MethodOtto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 134
Conducting polymers ? bridging the bionic interface
Wallace, G. G., & Spinks, G. M. (2007) · Soft Matter · doi:10.1039/b618204f · Cited by 127
Selective adhesion of astrocytes to surfaces modified with immobilized peptides
Kam, L. C., Shain, W. G., Turner, J. N., & Bizios, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00133-8 · Cited by 124
The effect of initial polymer morphology on the degradation and drug release from polyglycolide
Hurrell, S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00376-3 · Cited by 120
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
Maynard, E. M., Fernández, E., & Normann, R. A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00159-x · Cited by 104
Microporous conducting polymers on neural microelectrode arrays
Yang, J., & Martin, D. C. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.02.056 · Cited by 84
Self-citationPreparation of hydrogel/conducting polymer composites
Gilmore, K. J., Hodgson, A. J., Luan, B., Small, C. J., & Wallace, G. G. (1994) · Polymer Gels and Networks · doi:10.1016/0966-7822(94)90032-9 · Cited by 70
Glial cell and fibroblast cytotoxicity study on plasma-deposited diamond-like carbon coatings
Singh, A., Ehteshami, G., Massia, S. P., He, J., Storer, R. G., & Raupp, G. B. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00424-1 · Cited by 66
Yang, J., Lipkin, K., & Martin, D. C. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207781494359 · Cited by 38
Self-citation
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationStretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
Metadata
- Authors
- Abidian, M. R., & Martin, D. C.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2009-02-19
- Volume
- 19
- Issue
- 4
- Pages
- 573-585
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2119989931
- Cited by
- 416
- References
- 79
- FWCI
- 10.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.