The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
Abstract
Relative cerebral blood flow changes can be measured by a novel simple blood flow measurement technique with endogenous water protons as a tracer based on flow‐sensitive alternating inversion recovery (FAIR). Two inversion recovery (IR) images are acquired by interleaving slice‐selective inversion and nonselective inversion. During the inversion delay time after slice‐selective inversion, fully magnetized blood spins move into the imaging slice and exchange with tissue water. The signal enhancement (FAIR image) measured by the signal difference between two images is directly related to blood flow. For functional MR imaging studies, two IR images are alternatively and repeatedly acquired during control and task periods. Relative signal changes in the FAIR images during the task periods represent the relative regional cerebral blood flow changes. The FAIR technique has been successfully applied to functional brain mapping studies in humans during finger opposition movements. The technique is capable of generating microvascular‐based functional maps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 4×
“In contrast, the most widely used functional magnetic resonance imaging (MRI) technique is based on blood oxygenation level-dependent (BOLD) effect (2-4), which is sensitive to alterations in local deoxyhemoglobin content (5-8).”
BackgroundMethodInfluentialOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationOxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935 · cited 1×
“In contrast, the most widely used functional magnetic resonance imaging (MRI) technique is based on blood oxygenation level-dependent (BOLD) effect (2-4), which is sensitive to alterations in local deoxyhemoglobin content (5-8).”
MethodFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationDetre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
What does fMRI tell us about neuronal activity?
Heeger, D. J., & Ress, D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn730 · Cited by 1,085
Calibrated functional MRI: Mapping the dynamics of oxidative metabolism
Davis, T. L., Kwong, K. K., Weisskoff, R. M., & Rosen, B. R. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1834 · Cited by 1,052
Vascular and Neurogenic Rejuvenation of the Aging Mouse Brain by Young Systemic Factors
Katsimpardi, L., Litterman, N. K., Schein, P. A., Miller, C. M., Loffredo, F. S., Wojtkiewicz, G. R., Chen, J. W., Lee, R. T., Wagers, A. J., & Rubin, L. L. (2014) · Science · doi:10.1126/science.1251141 · Cited by 1,037
A functional MRI study of subjects recovered from hemiparetic stroke
Cramer, S. C., Nelles, G., Benson, R. R., Kaplan, J. D., Parker, R. A., Kwong, K. K., Kennedy, D. N., Finklestein, S. P., & Rosen, B. R. (1997) · Stroke · doi:10.1161/01.str.28.12.2518 · Cited by 1,019
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Swain, R. A., Harris, A. B., Wiener, E. C., Dutka, M. V., Morris, H. D., Theien, B. E., Konda, S., Engberg, K., Lauterbur, P. C., & Greenough, W. T. (2003) · Neuroscience · doi:10.1016/s0306-4522(02)00664-4 · Cited by 655
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Shmuel, A., Yacoub, E., Pfeuffer, J., Van de Moortele, P.-F., Adriany, G., Hu, X., & Ugurbil, K. (2002) · Neuron · doi:10.1016/s0896-6273(02)01061-9 · Cited by 631
Glial Neoplasms: Dynamic Contrast-enhanced T2*-weighted MR Imaging
Knopp, E. A., Cha, S., Johnson, G., Mazumdar, A., Golfinos, J. G., Zagzag, D., Miller, D. C., Kelly, P. J., & Kricheff, I. I. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn46791 · Cited by 596
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<849::aid-mrm4>3.0.co;2-z · Cited by 576
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationLinear coupling between cerebral blood flow and oxygen consumption in activated human cortex
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9403 · Cited by 563
Magnetic Resonance Imaging of Acute Stroke
Baird, A. E., & Warach, S. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199806000-00001 · Cited by 545
Cha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D. (2002) · Radiology · doi:10.1148/radiol.2231010594 · Cited by 525
Cruz Hernández, J. C., Bracko, O., Kersbergen, C. J., Muse, V., Haft-Javaherian, M., Berg, M., Park, L., Vinarcsik, L. K., Ivasyk, I., Rivera, D. A., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-018-0329-4 · Cited by 508
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Wu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Parkes, L. M., Rashid, W., Chard, D. T., & Tofts, P. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20023 · Cited by 449
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Lu, H., & Ge, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21627 · Cited by 360
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Self-citationLocalized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Self-citationApplications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements
Günther, M., Oshio, K., & Feinberg, D. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20580 · Cited by 293
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
“Several ASL strategies exist, including slab pseudo-saturation (Detre et al., 1992), continuous adiabatic inversion (Williams et al., 1992), slab inversion (Edelman et al., 1994; Wong et al., 1998), and selective/ non-selective inversion (Kim, 1995; Kwong et al., 1995).”
MethodWang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Analyzing for information, not activation, to exploit high-resolution fMRI
Kriegeskorte, N., & Bandettini, P. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.022 · Cited by 270
Kim, S.-G., Rostrup, E., Larsson, H. B. W., Ogawa, S., & Paulson, O. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1152::aid-mrm11>3.0.co;2-t · Cited by 268
Self-citationOgawa, S., Lee, T.-M., Stepnoski, R., Chen, W., Zhu, X.-H., & Ugurbil, K. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.20.11026 · Cited by 265
Twenty years of functional MRI: The science and the stories
Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.026 · Cited by 265
Sicard, K., Shen, Q., Brevard, M. E., Sullivan, R., Ferris, C. F., King, J. A., & Duong, T. Q. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200304000-00011 · Cited by 263
Brain aging mechanisms with mechanical manifestations
Blinkouskaya, Y., Caçoilo, A., Gollamudi, T., Jalalian, S., & Weickenmeier, J. (2021) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2021.111575 · Cited by 258
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Nicotine Enhances Visuospatial Attention by Deactivating Areas of the Resting Brain Default Network
Hahn, B., Ross, T. J., Yang, Y., Kim, I., Huestis, M. A., & Stein, E. A. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.5129-06.2007 · Cited by 199
Focusing neurovisceral integration: Cognition, heart rate variability, and cerebral blood flow
Jennings, J. R., Allen, B., Gianaros, P. J., Thayer, J. F., & Manuck, S. B. (2015) · Psychophysiology · doi:10.1111/psyp.12319 · Cited by 134
Improved Reperfusion and Neuroprotection by Creatine in a Mouse Model of Stroke
Prass, K., Royl, G., Lindauer, U., Freyer, D., Megow, D., Dirnagl, U., Stöckler-Ipsiroglu, G., Wallimann, T., & Priller, J. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600351 · Cited by 128
Selective reduction of blood flow to white matter during hypercapnia corresponds with leukoaraiosis
Mandell, D. M., Han, J. S., Poublanc, J., Crawley, A. P., Kassner, A., Fisher, J. A., & Mikulis, D. J. (2008) · Stroke · doi:10.1161/strokeaha.107.501692 · Cited by 114
Tarumi, T., Shah, F., Tanaka, H., & Haley, A. P. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.101 · Cited by 108
Physiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
“www.elsevier.com/locate/ynimg NeuroImage 31 (2006) 1104 – 1115 Physiological noise reduction for arterial spin labeling functional MRI Khaled Restom,a,b Yashar Behzadi,a,b and Thomas T. Liua,* aCenter for Functional Magnetic Resonance Imaging and Department of Radiology, UCSD Center for Functional MRI, 9500 Gilman Dri…”
BackgroundIn vivo imaging of tau pathology using multi-parametric quantitative MRI
Wells, J. A., O'Callaghan, J. M., Holmes, H. E., Powell, N. M., Johnson, R. A., Siow, B., Torrealdea, F., Ismail, O., Walker-Samuel, S., Golay, X., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.023 · Cited by 93
Hocking, J., McMahon, K. L., & de Zubicaray, G. I. (2009) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21114 · Cited by 87
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
A Dietary Treatment Improves Cerebral Blood Flow and Brain Connectivity in Aging apoE4 Mice
Wiesmann, M., Zerbi, V., Jansen, D., Haast, R., Lütjohann, D., Broersen, L. M., Heerschap, A., & Kiliaan, A. J. (2016) · Neural Plasticity · doi:10.1155/2016/6846721 · Cited by 60
Imaging the accumulation and suppression of tau pathology using multiparametric MRI
Holmes, H. E., Colgan, N., Ismail, O., Ma, D., Powell, N. M., O'Callaghan, J. M., Harrison, I. F., Johnson, R. A., Murray, T. K., Ahmed, Z., et al. (2016) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2015.12.001 · Cited by 51
Biswal (1997) · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<165::aid-nbm454>3.0.co;2-7
Metadata
- Authors
- Kim, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 34
- Issue
- 3
- Pages
- 293-301
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2021496866
- Cited by
- 1,001
- References
- 51
- FWCI
- 24.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.