Tear Glucose Analysis for the Noninvasive Detection and Monitoring of Diabetes Mellitus
The DOI matches its Crossref record; 98 of the 101 references it cites were found in a registry or an index.
Abstract
One approach to the noninvasive monitoring of blood glucose concentration is to monitor glucose concentrations in tear fluid. While several methods for sensing glucose in tear fluid have been proposed, controversy remains as to the precise concentrations of tear glucose in normal and diabetic subjects and as to whether tear fluid glucose concentrations correlate with blood glucose concentrations. This review covers the present understanding of the physiology of glucose transport in tears, the regulation of the aqueous tear fraction, and studies of tear glucose concentration over the last 80 years. The various tear collection methods employed greatly influence the measured tear glucose concentrations. Studies that involve mechanical irritation of the conjunctiva during sampling measure the highest tear glucose concentrations, while studies that avoid tear stimulation measure the lowest concentrations. Attempts to monitor tear glucose concentration in situ by using contact lens-based sensing devices are discussed, and new observations are presented of tear glucose concentration obtained by a method designed to avoid tear stimulation. These studies indicate the importance of the sampling method in determining tear glucose concentrations. On the basis of these results, we discuss the future of in vivo tear glucose sensing and outline the studies needed to resolve the remaining questions about the relationship between tear and blood glucose concentrations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, crystalline colloidal arrays and holographic sensors have been incorporated into contact lenses to continuously sense glucose using phenylboronic acid derivatives in hydrogels.68”
From Wearables in Medicine (2018) · cites this paper as [68]
In the citing paper
“Studies designed to establish correlations between blood and tear glucose concentrations are inconclusive from both human (243-245) and animal studies (246).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [243]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [95]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [95]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [95]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Economic Costs of Diabetes in the U.S. in 2002
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.3.917 · Cited by 4,147
Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus
The Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group (2002) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.287.19.2563 · Cited by 941
Functional aspects of the tear film lipid layer
Bron, A. J., Tiffany, J. M., Gouveia, S. M., Yokoi, N., & Voon, L. W. (2004) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.019 · Cited by 782
Standards of Medical Care in Diabetes
American Diabetes Association (2004) · Diabetes Care · doi:10.2337/diacare.27.2007.s15 · Cited by 683
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Determination of tear volume and tear flow.
Mishima, S., Gasset, A. R., Klyce, S. D., & BAUM, J. L. (1966) · PubMed · Cited by 607
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Economic Costs of Diabetes in the U.S. in 2002Preprint
Dall, T. M., Nikolov, P., & Hogan, P. F. (2003) · RePEc: Research Papers in Economics · Cited by 482
Research works printed but not linked: 6
- Michail, 1937, Lacrimal elimination of glucose in diabetic patients, C R Soc Biol Paris, 125, 194
- Fourcroy, 1791, Examen Chimique des Larmes et de l'Humeur des Narines, Annales de Chimie, 10, 113
- Balik, 1965, Method for the biochemical study of tears, Acta Ophthalmol, 43, 190
- Motoji, 1971, The glucose content of tear fluid in normal and diabetic subjects, Jpn J Clin Ophthalmol, 25, 1945
- Michail, 1937, Lacrimal elimination of glucose during alimentary hyperglycemia, CR Soc Biol Paris, 126, 1042
- Michail, 1937, Lachrymal elimination of glucose during adrenaline hyperglucemia, CR Soc Biol Paris, 125, 1095
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
“43,44 The development in non-invasive glucose monitoring has been reviewed in 2008 and it is expected to make greater progress in the future.”
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
“Indeed, there is evidence that collection methods that irritate the conjunctiva give rise to the highest tear glucose results (Baca et al., 2007b).”
Wireless smart contact lens for diabetic diagnosis and therapy
Keum, D. H., Kim, S.-K., Koo, J., Lee, G.-H., Jeon, C., Mok, J. W., Mun, B. H., Lee, K. J., Kamrani, E., Joo, C.-K., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba3252 · Cited by 483
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Holographic Sensors: Three-Dimensional Analyte-Sensitive Nanostructures and Their Applications
Yetisen, A. K., Naydenova, I., da Cruz Vasconcellos, F., Blyth, J., & Lowe, C. R. (2014) · Chemical Reviews · doi:10.1021/cr500116a · Cited by 224
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Glucose Sensing with Phenylboronic Acid Functionalized Hydrogel-Based Optical Diffusers
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.7b07082 · Cited by 210
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Liu, Y., Yu, Q., Luo, X., Yang, L., & Cui, Y. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00302-w · Cited by 182
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Kownacka, A. E., Vegelyte, D., Joosse, M., Anton, N., Toebes, B. J., Lauko, J., Buzzacchera, I., Lipinska, K., Wilson, D. A., Geelhoed-Duijvestijn, N., et al. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b01429 · Cited by 164
“11,12 A number of proof-of concept enzymatic prototype devices have attempted to demonstrate the potential to be used as tear glucose sensors but with little success.”
Polymerized Crystalline Colloidal Array Sensing of High Glucose Concentrations
Ward Muscatello, M. M., Stunja, L. E., & Asher, S. A. (2009) · Analytical Chemistry · doi:10.1021/ac900006x · Cited by 156
Self-citationTseng, R. C., Chen, C.-C., Hsu, S., & Chuang, H.-S. (2018) · Sensors · doi:10.3390/s18082651 · Cited by 164
“Sampling methods can affect the composition of the tear fluid collected [31].”
MethodPark, W., Seo, H., Kim, J., Hong, Y., Song, H., Joo, B. J., Kim, S., Kim, E., Yae, C., Kim, J., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47123-9 · Cited by 169
“It is consistent with the fi ndings from previous studies that mechanical stimulation can cause glucose to leak directly from the interstitial space or epithelial cells into the tear fl uid 20,41 .”
InfluentialNoninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose
Zhang, J., Hodge, W., Hutnick, C., & Wang, X. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500123 · Cited by 147
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 160
A photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature
Gao, X., Chen, X., Hu, H., Wang, X., Yue, W., Mu, J., Lou, Z., Zhang, R., Shi, K., Chen, X., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-35455-3 · Cited by 136
“None of them has access to biomolecules in deep tissues, which have a stronger and faster correlation with the physiological and metabolic processes in the human body than those close to the skin surface 25 (Supplementary Note 1, Supplementary Table 1).”
A review of optical methods for continuous glucose monitoring
Jernelv, I. L., Mileńko, K., Fuglerud, S. S., Hjelme, D. R., Ellingsen, R., & Aksnes, A. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1486324 · Cited by 145
“However, the glucose concentration is much lower in tear fluid than in blood, and the glucose levels in tear fluid and blood do not seem to correlate well throughout the day (37,38).”
BackgroundOrganic Bioelectronic Devices for Metabolite Sensing
Koklu, A., Ohayon, D., Wustoni, S., Druet, V., Saleh, A., & Inal, S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00395 · Cited by 149
Paper-Based Colorimetric Biosensor for Tear Glucose Measurements
Gabriel, E. F. M., Garcia, P. D. T., Lopes, F. M., & Coltro, W. K. T. (2017) · Micromachines · doi:10.3390/mi8040104 · Cited by 137
“In general, these sensors are fabricated by depositing electrochemical trials over the contact lens and placed directly on the eye [8,9].”
BackgroundInfluentialArylboronic acids: A diabetic eye on glucose sensing
Hansen, J. S., Christensen, J. B., Petersen, J. F., Høeg-Jensen, T., & Norrild, J. C. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.024 · Cited by 133
Paper-based planar reaction arrays for printed diagnostics
Määttänen, A., Fors, D., Wang, S., Valtakari, D., Ihalainen, P., & Peltonen, J. P. K. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.09.086 · Cited by 130
Recent Advances in Smart Contact Lenses
Kim, J., Cha, E., & Park, J. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900728 · Cited by 125
Wu, W., Shen, J., Li, Y., Zhu, H., Banerjee, P., & Zhou, S. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.031 · Cited by 120
“Because the tear fluid glucose levels are parallel to the blood glucose levels [46,47], a tear fluid glucose measurement is proposed for the noninvasive detection and monitoring of diabetes [25,26,32,48].”
BackgroundWireless Non‐Invasive Monitoring of Cholesterol Using a Smart Contact Lens
Song, H., Shin, H., Seo, H., Park, W., Joo, B. J., Kim, J., Kim, J., Kim, H. K., Kim, J., & Park, J. (2022) · Advanced Science · doi:10.1002/advs.202203597 · Cited by 129
Nanomaterial based electrochemical sensors for in vitro detection of small molecule metabolites
Xiao, F., Wang, L., & Duan, H. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.01.006 · Cited by 117
Glucose Sensing Using Surface-Enhanced Raman-Mode Constraining
Yang, D., Afroosheh, S., Lee, J. O., Cho, H., Kumar, S., Siddique, R. H., Narasimhan, V., Yoon, Y.-Z., Zayak, A. T., & Choo, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03420 · Cited by 111
Kap, Ö., Kılıç, V., Hardy, J. G., & Horzum, N. (2021) · The Analyst · doi:10.1039/d0an02031a · Cited by 112
Li, N., Zang, H., Sun, H., Jiao, X., Wang, K., Liu, T. C., & Meng, Y. (2019) · Molecules · doi:10.3390/molecules24081500 · Cited by 114
“The studies of using numerous body fluids including tear fluid [25,26], salivary [27], and sweat [28] instead of blood [29] have shown that Raman spectroscopy is a powerful tool for non-invasive detection of blood glucose.”
BackgroundOptical Assessment of Tear Glucose by Smart Biosensor Based on Nanoparticle Embedded Contact Lens
Jeon, H., Kim, S., Park, S., Jeong, I., Kang, J., Kim, Y. R., Lee, D. Y., & Chung, E. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c01880 · Cited by 103
Smart Skin‐Adhesive Patches: From Design to Biomedical Applications
Wong, S. H. D., Deen, G. R., Bates, J. S., Maiti, C., Lam, C. Y. K., Pachauri, A., AlAnsari, R., Bělský, P., Yoon, J., & Dodda, J. M. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213560 · Cited by 101
Recent developments in wearable biosensors for healthcare and biomedical applications
Erdem, A., Ekşin, E., Senturk, H., Yildiz, E., & Maral, M. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117510 · Cited by 113
La Belle, J. T., Adams, A., Lin, C.-E., Engelschall, E., Pratt, B., & Cook, C. B. (2016) · Chemical Communications · doi:10.1039/c6cc03609k · Cited by 93
Smart Contact Lenses for Healthcare Monitoring and Therapy
Liu, X., Ye, Y., Ge, Y., Qu, J., Liedberg, B., Zhang, Q., & Wang, Y. (2024) · ACS Nano · doi:10.1021/acsnano.3c12072 · Cited by 100
Zheng, W., Wu, H., Jiang, Y., Xu, J., Li, X., Zhang, W., & Qiu, F. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.06.004 · Cited by 91
Commercial and Scientific Solutions for Blood Glucose Monitoring—A Review
Xue, Y., Thalmayer, A. S., Zeising, S., Fischer, G., & Lübke, M. (2022) · Sensors · doi:10.3390/s22020425 · Cited by 96
“In addition, the worldwide use of contact lenses is a strong motivation for tear glucose measurement [56].”
BackgroundA Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose
Ruan, J.-L., Chen, C., Shen, J.-H., Zhao, X.-L., Qian, S.-H., & Zhu, Z.-G. (2017) · Polymers · doi:10.3390/polym9040125 · Cited by 83
Aihara, M., Kubota, N., Minami, T., Shirakawa, R., Sakurai, Y., Hayashi, T., Iwamoto, M., Takamoto, I., Kubota, T., Suzuki, R., et al. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13344 · Cited by 86
Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric Sensing
Kagie, A., Bishop, D. K., Burdick, J., La Belle, J. T., Dymond, R., Felder, R., & Wang, J. (2008) · Electroanalysis · doi:10.1002/elan.200804253 · Cited by 77
Smart Contact Lenses—A Step towards Non-Invasive Continuous Eye Health Monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2023) · Biosensors · doi:10.3390/bios13100933 · Cited by 82
Ophthalmic Sensors and Drug Delivery
Savariraj, A. D., Salih, A. E., Alam, F., Elsherif, M., AlQattan, B., Khan, A. A., Yetisen, A. K., & Butt, H. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00370 · Cited by 69
Gupta, S., & Tai, N. (2023) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2023.104957 · Cited by 72
Evaluation of commercial glucometer test strips for potential measurement of glucose in tears
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E. (2014) · Analytical Chemistry · doi:10.1021/ac4040168 · Cited by 67
Metabolomics and Age-Related Macular Degeneration
Brown, C. N., Green, B., Thompson, R., den Hollander, A. I., & Lengyel, I. (2018) · Metabolites · doi:10.3390/metabo9010004 · Cited by 72
“It is well known that tear glucose levels are variable diurnally [193] and from which eye the sample is taken [192].”
BackgroundMethodNoninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses
Ascaso, F. J., & Huerva, V. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000000698 · Cited by 67
“However, although several authors have reported a good correlation between tear glucose and blood glucose, others talk about the glucose levels in tears being below detection.(22,26) These discrepancies are probably attributed to the different tear collection methods, for example, filter paper or microcapillary.”
BackgroundHu, Y., Jiang, X., Zhang, L., Fan, J. R., & Wu, W. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.03.082 · Cited by 65
“. tears (Baca et al., 2007; Badugu et al., 2004a, 2004b; Domschke et al., 2006; Taormina et al., 2007; Wu et al., 2012; Yao et al., 2011; Yang et al., 2008; Zhang et al., 2011), whose glucose concentration is tightly linked to that in blood (March et al., 2004; Michail et al., 1937).”
BackgroundInfluentialWearable Smart Contact Lenses for Continual Glucose Monitoring: A Review
Elsherif, M., Moreddu, R., Alam, F., Salih, A. E., Ahmed, I., & Butt, H. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.858784 · Cited by 72
Flexible, wearable microfluidic contact lens with capillary networks for tear diagnostics
Yang, X., Yao, H., Zhao, G., Ameer, G. A., Sun, W., Yang, J. H., & Mi, S. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-04688-2 · Cited by 65
Tao, L., Xu, Y., Zhao, A., He, W., & Xiao, F. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339461 · Cited by 61
Therapeutic contact lenses: a patent review
Dixon, P., Shafor, C. S., Gause, S., Hsu, K.-H., Powell, K. C., & Chauhan, A. (2015) · Expert Opinion on Therapeutic Patents · doi:10.1517/13543776.2015.1057501 · Cited by 59
“is too slow for the time-effective detection needed to successfully treat diabetic patients [105].”
BackgroundGlucose-sensitive silicone hydrogel contact lens toward tear glucose monitoring
Badugu, R., Reece, E. A., & Lakowicz, J. R. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.5.057005 · Cited by 59
Guo, M., Yin, X., Zhou, C., Xia, Y. Y., Huang, W., & Li, Z. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.07.135 · Cited by 52
Advanced glycation end product (AGE) modified proteins in tears of diabetic patients.
Zhao, Z., Liu, J., Shi, B., He, S., Yao, X., & Willcox, M. D. P. (2010) · PubMed Central · Cited by 50
Wireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 54
Park, S., Hwang, J., Jeon, H., Bae, W. R., Jeong, I.-K., Kim, T. G., Kang, J., Han, Y.-G., Chung, E., & Lee, D. Y. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c00603 · Cited by 51
Power supply for electronic contact lenses: Abiotic glucose fuel cells vs. Mg/air batteries
Frei, M., Martin, J., Kindler, S., Cristiano, G., Zengerle, R., & Kerzenmacher, S. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.08.101 · Cited by 47
Noninvasive Self-diagnostic Device for Tear Collection and Glucose Measurement
Lee, S. H., Cho, Y. C., & Choy, Y. B. (2019) · Scientific Reports · doi:10.1038/s41598-019-41066-8 · Cited by 49
Galbis-Estrada, C., Pinazo-Duran, M. D., Martínez-Castillo, S., Morales, J. M., Monleón, D., & Zanón‐Moreno, V. (2015) · PubMed Central · Cited by 46
Dammeier, S., Martus, P., Klose, F., Seid, M., Bosch, D., D’Alvise, J., Ziemssen, F., Dimopoulos, S., & Ueffing, M. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.6.22 · Cited by 44
A Set of Global Metabolomic Biomarker Candidates to Predict the Risk of Dry Eye Disease
Jiang, Y., Yang, C., Zheng, Y., Liu, Y., & Chen, Y. (2020) · Frontiers in Cell and Developmental Biology · doi:10.2139/ssrn.3520029 · Cited by 40
Fiber optic biosensor for transdermal glucose based on the glucose binding protein
Tiangco, C. E., Fon, D., Sardesai, N., Kostov, Y. V., Sevilla, F. B., III, Rao, G., & Tolosa, L. M. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.077 · Cited by 39
Shi, Z., Li, X., Shuai, Y., Lu, Y., & Liu, Q. (2022) · Nutrition Bulletin · doi:10.1111/nbu.12581 · Cited by 47
2D-Materials-Based Wearable Biosensor Systems
Wang, Y., Li, T., Li, Y., Yang, R., & Zhang, G. (2022) · Biosensors · doi:10.3390/bios12110936 · Cited by 45
Patient Acceptability of Tear Collection in the Primary Healthcare Setting
Quah, J. H. M., Tong, L. H. T., & Barbier, S. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000188 · Cited by 35
“Glycemic control can also be tracked with tear examination.(17,18) Thyroid eye disease, also known as Graves’ ophthalmopathy, is a characteristic feature of Graves’ disease.”
BackgroundInsight into continuous glucose monitoring: from medical basics to commercialized devices
Chmayssem, A., Nadolska, M., Tubbs, E., Sadowska, K., Vadgma, P., Shitanda, I., Tsujimura, S., Lattach, Y., Peacock, M., Tingry, S., et al. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05743-w · Cited by 40
“5 mM) is known to well-correlate with blood glucose [85, 86].”
BackgroundFabricated Micro‐Nano Devices for In vivo and In vitro Biomedical Applications
Barkam, S., Saraf, S., & Seal, S. (2013) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1236 · Cited by 40
Duong, H. D., Sohn, O.-J., & Rhee, J. I. (2020) · Biosensors · doi:10.3390/bios10080086 · Cited by 34
“The tear glucose of diabetics has been studied since the beginning of the last century [19] and in a recent contribution of Wang et al.”
BackgroundPerformance of the Prototype NovioSense Noninvasive Biosensor for Tear Glucose in Type 1 Diabetes
Geelhoed-Duijvestijn, P. H. L. M., Vegelyte, D., Kownacka, A., Anton, N., Joosse, M. V., & Wilson, C. J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820964844 · Cited by 34
Patle, S. K., & Rotake, D. R. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110457 · Cited by 36
Powering electronic contact lenses: current achievements, challenges, and perspectives
Blum, Z., Pankratov, D., & Shleev, S. (2014) · Expert Review of Ophthalmology · doi:10.1586/17469899.2014.922873 · Cited by 35
“For a glucose sensing application, it would be important to mention several recent reports in the literature showing that the tear glucose concentration is quite adequately correlated (that is, real-time amounts) to blood glucose levels [5,26,27].”
BackgroundGiaretta, J., Zulli, R., Prabhakar, T., Rath, R. J., Naficy, S., Spilimbergo, S., Weiss, P. S., Farajikhah, S., & Dehghani, F. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400065 · Cited by 35
Optical biosensing systems for a biological living body
Yan, T., Guo, C., Wang, C., & Zhu, K. (2023) · View · doi:10.1002/viw.20220059 · Cited by 30
Richdale, K., Chao, C., & Hamilton, M. T. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001094 · Cited by 31
Manicam, C., Perumal, N., Wasielica‐Poslednik, J., Ngongkole, Y. C., Tschäbunin, A., Sievers, M., Lisch, W., Pfeiffer, N., Grus, F. H., & Gericke, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-30032-5 · Cited by 36
Biosensing Technologies for Chronic Diseases
Park, M., & Heo, Y. J. (2021) · BioChip Journal · doi:10.1007/s13206-021-00014-3 · Cited by 30
Recent Advances in Fluorescent Arylboronic Acids for Glucose Sensing
Hansen, J., & Christensen, J. B. (2013) · Biosensors · doi:10.3390/bios3040400 · Cited by 29
“However, the reliability of these approaches has been widely discussed [17–19].”
Spatiotemporal electrochemical sensing in a smart contact lens
Donora, M., Quintero, A. V., Smet, H. D., & Underwood, I. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127203 · Cited by 27
“Reported prototypes have so far focussed primarily on glucose monitoring for diabetes management,[6,7] with one lens also investigating lactate,[8] but concerns about the measurement fidelity and time delay from blood glucose to tear glucose have presented significant problems in the route to clinical use.[12,34,35] G…”
BackgroundMethodNFC/RFID-enabled wearables and implants for biomedical applications
Zou, H., Zhou, Z., Huang, M., Li, W., Yang, B., Zhao, X. H., Li, T., Xu, L., Wang, T., & Wang, L. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01010-5 · Cited by 42
The marriage of biochemistry and nanotechnology for non-invasive real-time health monitoring
Ji, D., Guo, X., Fu, W., Ding, Z., Wang, C., Zhang, Q., Ramakrishna, S., & Qin, X. (2022) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2022.100681 · Cited by 29
Small-volume detection: platform developments for clinically-relevant applications
Sung, W.-H., Tsao, Y., Shen, C., Tsai, C., & Cheng, C. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-00852-1 · Cited by 25
“the ocular surface, but is more challenging to execute than the other two approaches described above [20, 32].”
BackgroundA Disposable Tear Glucose Biosensor--Part 1: Design and Concept Testing
Bishop, D. K., Belle, J. T. L., Vossler, S. R., Patel, D., & Cook, C. B. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400209 · Cited by 24
Sebbag, L., Showman, L. J., McDowell, E. M., Perera, A. M., & Mochel, J. P. (2018) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.2018.0008 · Cited by 24
Hennig, A., Lauko, J., Grabmaier, A., & Wilson, C. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.11.267 · Cited by 27
The Use of Contact Lenses as Biosensors
Phan, C., Subbaraman, L. N., & Jones, L. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000000763 · Cited by 24
“Compared with tear fluid, the concentration of glucose in subcutaneous fluid is more aligned with blood glucose levels and has been studied more extensively.(65) There are also groups that have developed implantable sensors to measure absolute IOP.”
BackgroundA Technology Roadmap of Smart Biosensors From Conventional Glucose Monitoring Systems
Shende, P. K., Sahu, P., & Gaud, R. S. (2017) · Therapeutic Delivery · doi:10.4155/tde-2017-0012 · Cited by 24
Recent advances in the study of tear biomarkers and contact lens-based biosensors
Bai, W., Yu, X., Li, Q., Tan, H., Ma, K., Bai, H., Li, S., Hu, J. H., Yao, Y., Zhuang, W., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.156540 · Cited by 24
Towards Closed-Loop Integration of Point-of-Care Technologies
Tan, E. K. W., Au, Y. Z., Moghaddam, G. K., Occhipinti, L. G., & Lowe, C. R. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.12.004 · Cited by 25
Plasmonic smart contact lens based on etalon nanostructure for tear glucose sensing
Roostaei, N., & Hamidi, S. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-99624-2 · Cited by 21
Math, C., Income, K., Khachornsakkul, K., Duenchay, P., & Dungchai, W. (2023) · The Analyst · doi:10.1039/d3an00879g · Cited by 20
Ogata, A. F., Song, S.-W., Cho, S., Koo, W., Jang, J., Jeong, Y. J., Kim, M., Cheong, J. Y., Penner, R. M., & Kim, I. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01959 · Cited by 18
Patel, J. N., Gray, B. L., Kaminska, B., & Gates, B. D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500503 · Cited by 18
Han, J. H., Cho, Y. C., Koh, W., & Choy, Y. B. (2020) · PLoS ONE · doi:10.1371/journal.pone.0239317 · Cited by 17
Metadata
- Authors
- Baca, J. T., Finegold, D. N., & Asher, S. A.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Asher, Sanford A.
- Venue
- The Ocular Surface
- Publisher
- Elsevier BV
- Published
- 2007-10
- Volume
- 5
- Issue
- 4
- Pages
- 280-293
- ISSN
- 1542-0124 (ISSN-L)
- OpenAlex
- W2062561734
- Semantic Scholar
- f72af5dfc6f5b8d76792108fc0e9d5ed522c11a5
- Cited by
- 187
- References
- 101
- Citations by year
- 2026: 10 · 2025: 13 · 2024: 13 · 2023: 20 · 2022: 14 · 2021: 10 · 2020: 10 · 2019: 14 · 2018: 21 · 2017: 10 · 2016: 8 · 2015: 7 · 2014: 10 · 2013: 6 · 2012: 3
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Ocular Surface (publishedVersion)
- PubMed (publishedVersion)
- D-Scholarship@Pitt (University of Pittsburgh) (acceptedVersion)
- Funders
- National Institutes of Health (1f31eb004181-01a1)
- National Institute of Biomedical Imaging and Bioengineering (1 F31 EB004181-01A1, R01EB004132)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- tear glucose, diabetes mellitus, non-invasive glucose monitoring
- MeSH terms
- Animals, Aqueous Humor, Diabetes Mellitus, Glucose, Humans, Monitoring, Physiologic, Tears
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.