Integration of novel monitoring devices with machine learning technology for scalable cardiovascular management
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Ambulatory monitoring is increasingly important for cardiovascular care but is often limited by the unpredictability of cardiovascular events, the intermittent nature of ambulatory monitors and the variable clinical significance of recorded data in patients. Technological advances in computing have led to the introduction of novel physiological biosignals that can increase the frequency at which abnormalities in cardiovascular parameters can be detected, making expert-level, automated diagnosis a reality. However, use of these biosignals for diagnosis also raises numerous concerns related to accuracy and actionability within clinical guidelines, in addition to medico-legal and ethical issues. Analytical methods such as machine learning can potentially increase the accuracy and improve the actionability of device-based diagnoses. Coupled with interoperability of data to widen access to all stakeholders, seamless connectivity (an internet of things) and maintenance of anonymity, this approach could ultimately facilitate near-real-time diagnosis and therapy. These tools are increasingly recognized by regulatory agencies and professional medical societies, but several technical and ethical issues remain. In this Review, we describe the current state of cardiovascular monitoring along the continuum from biosignal acquisition to the identification of novel biosensors and the development of analytical techniques and ultimately to regulatory and ethical issues. Furthermore, we outline new paradigms for cardiovascular monitoring. Advances in cardiovascular monitoring technologies have resulted in an influx of consumer-targeted wearable sensors that have the potential to detect numerous heart conditions. In this Review, Krittanawong and colleagues describe processes involved in biosignal acquisition and analysis of cardiovascular monitors, as well as their associated ethical, regulatory and legal challenges. Advances in the use of cardiovascular monitoring technologies, such as the development of novel portable sensors and machine learning algorithms that can provide near-real-time diagnosis, have the potential to provide personalized care. Wearable sensor technologies can detect numerous biosignals, such as cardiac output, blood-pressure levels and heart rhythm, and can integrate multiple modalities. The use of novel biosignals for diagnosis raises concerns regarding accuracy and actionability within clinical guidelines, in addition to medical, legal and ethical issues. Machine learning-based interpretation of biosensor data can facilitate rapid evaluation of the haemodynamic consequences of heart failure or arrhythmias, but is limited by the presence of noise and training data that might not be representative of the real-world clinical setting. The use of data derived from cardiovascular monitoring devices is associated with numerous challenges, such as data security, accessibility and ownership, in addition to other ethical and regulatory concerns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
Ibanez, B., James, S., Agewall, S., Antunes, M. J., Bucciarelli-Ducci, C., Bueno, H., Caforio, A. L. P., Crea, F., Goudevenos, J. A., Halvorsen, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx393 · Cited by 9,728
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Self-citation2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Self-citationHeart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Ong, M. K., Romano, P. S., Edgington, S., Aronow, H. U., Auerbach, A. D., Black, J. T., De Marco, T., Escarce, J. J., Evangelista, L. S., Hanna, B., et al. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.7712 · Cited by 695
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625
Mass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Self-citationLowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446
Decoupling of mechanical properties and ionic conductivity in supramolecular lithium ion conductors
Mackanic, D. G., Yan, X., Zhang, Q., Matsuhisa, N., Yu, Z., Jiang, Y., Manika, T., Lopez, J., Yan, H., Liu, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13362-4 · Cited by 439
Hobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Stehlik, J., Schmalfuss, C., Bozkurt, B., Nativi-Nicolau, J., Wohlfahrt, P., Wegerich, S., Rose, K., Ray, R., Schofield, R., Deswal, A., et al. (2020) · Circulation Heart Failure · doi:10.1161/circheartfailure.119.006513 · Cited by 333
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation
Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.10.006 · Cited by 245
Who Owns the Data? Open Data for Healthcare
Kostkova, P., Brewer, H., de Lusignan, S., Fottrell, E., Goldacre, B., Hart, G., Koczan, P., Knight, P., Marsolier, C., McKendry, R. A., et al. (2016) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00007 · Cited by 230
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Clinical Classifications of Atrial Fibrillation Poorly Reflect Its Temporal Persistence
Charitos, E. I., Pürerfellner, H., Glotzer, T. V., & Ziegler, P. D. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.019 · Cited by 188
Kroll, R. R., Boyd, J. G., & Maslove, D. M. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.6025 · Cited by 123
Choi, A., & Shin, H. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5efa · Cited by 116
PASSMAN, R., LEONG‐SIT, P., ANDREI, A., HUSKIN, A., TOMSON, T. T., BERNSTEIN, R., ELLIS, E., WAKS, J. W., & ZIMETBAUM, P. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12864 · Cited by 115
Integrating blockchain technology with artificial intelligence for cardiovascular medicine
Krittanawong, C., Rogers, A. J., Aydar, M., Choi, E., Johnson, K. W., Wang, Z., & Narayan, S. M. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0294-y · Cited by 113
Self-citationJoshi, A. K., Kowey, P. R., Prystowsky, E. N., Benditt, D. G., Cannom, D. S., Pratt, C. M., McNamara, A., & Sangrigoli, R. M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.12.015 · Cited by 110
Kearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004565 · Cited by 106
Short-term ECG for out of hospital detection of silent atrial fibrillation episodes
Doliwa, P. S., Frykman, V., & Rosenqvist, M. (2009) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430802593435 · Cited by 105
High-Throughput, Contact-Free Detection of Atrial Fibrillation From Video With Deep Learning
Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Au, A. C. K., Freedman, B., Poh, Y. C., & Poh, M.-Z. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.4004 · Cited by 94
Kaleschke, G., Hoffmann, B., Drewitz, I., Steinbeck, G., Naebauer, M., Goette, A., Breithardt, G., & Kirchhof, P. (2009) · Europace · doi:10.1093/europace/eup262 · Cited by 81
Wiesel, J., Arbesfeld, B., & Schechter, D. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.016 · Cited by 80
Chan, P.-H., Wong, C.-K., Pun, L., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2017) · Circulation · doi:10.1161/circulationaha.116.024439 · Cited by 79
Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions
Brooke, S. M., An, H.-S., Kang, S.-K., Noble, J. M., Berg, K. E., & Lee, J.-M. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001571 · Cited by 79
Simultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2585109 · Cited by 69
de Asmundis, C., Conte, G., Sieira, J., Chierchia, G.-B., Rodriguez-Manero, M., Di Giovanni, G., Ciconte, G., Levinstein, M., Baltogiannis, G., Saitoh, Y., et al. (2014) · Europace · doi:10.1093/europace/eut411 · Cited by 52
Diagnosing With a Camera From a Distance—Proceed Cautiously and Responsibly
Turakhia, M. P. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.4572 · Cited by 9
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationWearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
6G Wireless Communications Networks: A Comprehensive Survey
Alsabah, M., Naser, M. A., Mahmmod, B. M., Abdulhussain, S. H., Eissa, M. R., Al-Baidhani, A., Noordin, N. K., Sait, S. M., Al-Utaibi, K. A., & Hashim, F. (2021) · IEEE Access · doi:10.1109/access.2021.3124812 · Cited by 575
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Ambulatory Cardiovascular Monitoring Via a Machine‐Learning‐Assisted Textile Triboelectric Sensor
Fang, Y., Zou, Y., Xu, J., Chen, G., Zhou, Y., Deng, W., Zhao, X., Roustaei, M., Hsiai, T. K., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202104178 · Cited by 380
Metadata
- Authors
- Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M.
- Venue
- Nature Reviews Cardiology
- Published
- 2020-10-09
- Volume
- 18
- Issue
- 2
- Pages
- 75-91
- ISSN
- 1759-5002 (ISSN-L)
- 1759-5010
- OpenAlex
- W3092371431
- Cited by
- 234
- References
- 53
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.