The DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Engineers are from PDMS-land, Biologists are from Polystyrenia
Abstract
As the integration of microfluidics into cell biology research proceeds at an ever-increasing pace, a critical question for those working at the interface of both disciplines is which device material to use for a given application. While PDMS and soft lithography methods offer the engineer rapid prototyping capabilities, PDMS as a material has characteristics that have known adverse effects on cell-based experiments. In contrast, while polystyrene (PS), the most commonly used thermoplastic for laboratory cultureware, has provided decades of grounded and validated research conclusions in cell behavior and function, PS as a material has posed significant challenges in microfabrication. These competing issues have forced microfluidics engineers and biologists to make compromises in how they approach specific research questions, and furthermore, have attenuated the impact of microfluidics on biological research. In this review, we provide a comparison of the attributes of PDMS and PS, and discuss reasons for their popularity in their respective fields. We provide a critical evaluation of the strengths and limitations of PDMS and PS in relation to the advancement and future impact on microfluidic cell-based studies and applications. We believe that engineers have a responsibility to overcome any challenges associated with microfabrication, whether with PS or other materials, and that engineers should provide options and solutions that assist biologists in their experimental design. Our goal is not to advocate for any specific material, but provide guidelines for researchers who desire to choose the most suitable material for their application, and suggest important research directions for engineers working at the interface between microfabrication technology and biological application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationPaper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Park, S. E., Georgescu, A., & Huh, D. (2019) · Science · doi:10.1126/science.aaw7894 · Cited by 847
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Consensus guidelines for the use and interpretation of angiogenesis assays
Nowak-Sliwinska, P., Alitalo, K., Allen, E., Anisimov, A., Aplin, A. C., Auerbach, R., Augustin, H. G., Bates, D. O., van Beijnum, J. R., Bender, R. H. F., et al. (2018) · Angiogenesis · doi:10.1007/s10456-018-9613-x · Cited by 590
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00234f · Cited by 513
Self-citationMicrofluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Commercialization of microfluidic devices
Volpatti, L. R., & Yetisen, A. K. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.010 · Cited by 432
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Tsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
An outlook on microfluidics: the promise and the challenge
Battat, S., Weitz, D. A., & Whitesides, G. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00731a · Cited by 333
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
A review on microreactors: Reactor fabrication, design, and cutting-edge applications
Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.03.026 · Cited by 305
Campbell, S. B., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 297
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Three-dimensional in vitro culture models in oncology research
Jubelin, C., Muñoz-Garcia, J., Griscom, L., Cochonneau, D., Ollivier, E., Heymann, M.-F., Vallette, F. M., Oliver, L., & Heymann, D. (2022) · Cell & Bioscience · doi:10.1186/s13578-022-00887-3 · Cited by 264
Microfluidic gut-on-a-chip with three-dimensional villi structure
Shim, K.-Y., Lee, D., Han, J., Nguyen, N.-T., Park, S., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0179-y · Cited by 229
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Artificial Intelligence in Regenerative Medicine: Applications and Implications
Nosrati, H., & Nosrati, M. (2023) · Biomimetics · doi:10.3390/biomimetics8050442 · Cited by 158
Evaluating natural killer cell cytotoxicity against solid tumors using a microfluidic model
Ayuso, J. M., Truttschel, R., Gong, M. M., Humayun, M., Virumbrales-Munoz, M., Vitek, R., Felder, M., Gillies, S. D., Sondel, P., Wisinski, K. B., et al. (2019) · OncoImmunology · doi:10.1080/2162402x.2018.1553477 · Cited by 142
Self-citationOn being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Tumor organoid models in precision medicine and investigating cancer-stromal interactions
Xu, R., Zhou, X., Wang, S., & Trinkle, C. (2021) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2020.107668 · Cited by 134
Microfluidic Arrays of Breast Tumor Spheroids for Drug Screening and Personalized Cancer Therapies
Prince, E., Kheiri, S., Wang, Y., Xu, F., Cruickshank, J., Topolskaia, V., Tao, H., Young, E. W. K., McGuigan, A. P., Cescon, D. W., et al. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202101085 · Cited by 121
Self-citationYang, J., Hirai, Y., Iida, K., Ito, S., Trumm, M., Terada, S., Sakai, R., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2020) · doi:10.1101/2020.06.10.141606 · Cited by 110
Microfluidics within a well: an injection-molded plastic array 3D culture platform
Lee, Y., Choi, J. W., Yu, J., Park, D., Ha, J., Son, K., Lee, S., Chung, M., Kim, H.-Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00336j · Cited by 99
Yang, J., Hirai, Y., Iida, K., Ito, S., Trumm, M., Terada, S., Sakai, R., Tsuchiya, T., Tabata, O., & Kamei, K.-I. (2023) · Communications Biology · doi:10.1038/s42003-023-04710-8 · Cited by 98
InVADE: integrated vasculature for assessing dynamic events
Lai, B. F. L., Huyer, L. D., Lu, R. X. Z., Drecun, S., Radisic, M., & Zhang, B. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703524 · Cited by 97
Organoid microphysiological system preserves pancreatic islet function within 3D matrix
Patel, S. N., Ishahak, M., Chaimov, D., Velraj, A., LaShoto, D., Hagan, D. W., Buchwald, P., Phelps, E. A., Agarwal, A., & Stabler, C. L. (2021) · Science Advances · doi:10.1126/sciadv.aba5515 · Cited by 97
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
Disease-on-a-chip: mimicry of tumor growth in mammary ducts
Vidi, P.-A., Maleki, T., Ochoa, M., Wang, L., Clark, S. M., Leary, J. F., & Lelièvre, S. A. (2014) · Lab Chip · doi:10.1039/c3lc50819f · Cited by 71
Microdissected “cuboids” for microfluidic drug testing of intact tissues
Horowitz, L. F., Rodriguez, A. D., Au-Yeung, A., Bishop, K. W., Barner, L. A., Mishra, G., Raman, A., Delgado, P., Liu, J. T. C., Gujral, T. S., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc00801j · Cited by 62
Koens, R., Tabata, Y., Serrano, J. C., Aratake, S., Yoshino, D., Kamm, R. D., & Funamoto, K. (2020) · APL Bioengineering · doi:10.1063/1.5127069 · Cited by 53
Chang, S.-Y., Voellinger, J. L., Van Ness, K. P., Chapron, B., Shaffer, R. M., Neumann, T., White, C. C., Kavanagh, T. J., Kelly, E. J., & Eaton, D. L. (2017) · Toxicology in Vitro · doi:10.1016/j.tiv.2017.01.007 · Cited by 49
Isolation of circulating tumour cells by physical means in a microfluidic device: a review
Patil, P., Madhuprasad, M., Kumeria, T., Losic, D., & Kurkuri, M. (2015) · RSC Advances · doi:10.1039/c5ra16489c · Cited by 47
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Busek, M., Nøvik, S., Aizenshtadt, A., Amirola-Martinez, M., Combriat, T., Grünzner, S., & Krauss, S. (2021) · Biosensors · doi:10.3390/bios11050162 · Cited by 41
Toward improved in vitro models of human cancer
Ayuso, J. M., Park, K.-Y., Virumbrales-Muñoz, M., & Beebe, D. J. (2021) · APL Bioengineering · doi:10.1063/5.0026857 · Cited by 40
Self-citationTesting Lab-on-a-Chip Technology for Culturing Human Melanoma Cells under Simulated Microgravity
Przystupski, D., Górska, A., Michel, O., Podwin, A., Śniadek, P., Łapczyński, R., Saczko, J., & Kulbacka, J. (2021) · Cancers · doi:10.3390/cancers13030402 · Cited by 29
Sønstevold, L., Czerkies, M., Escobedo-Cousin, E., Blonski, S., & Vereshchagina, E. (2023) · Micromachines · doi:10.3390/mi14030532 · Cited by 25
Metadata
- Authors
- Berthier, E., Young, E. W. K., & Beebe, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 7
- Pages
- 1224
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1995139987
- Cited by
- 799
- References
- 111
- FWCI
- 25.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.