Blood glucose measurement inside and outside the laboratory: both preanalytical and analytical challenges
The DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Abstract
Glucose measurement is a critical investigation in metabolic disease management, especially in diabetes and inherited disorders. However, both laboratory-based and handheld point-of-care (HPOC) (glucometers) glucose testing face significant preanalytical and analytical challenges. In central laboratories, glycolysis in uncentrifuged samples leads to glucose consumption, which may compromise diagnostic accuracy. Although sodium fluoride (NaF) is commonly used as a glycolysis inhibitor, it has a delayed effect, requiring several hours to stabilize glucose concentrations. Recently, citrate-buffered NaF-EDTA (FCE) tubes have been introduced to inhibit glycolysis more effectively, yet they remain underused. Preanalytical variables, including sample collection, transport, and processing delays, further impact glucose stability and the diagnosis of diabetes, including gestational diabetes mellitus (GDM). HPOC devices provide an alternative by delivering rapid results and minimizing preanalytical errors, but glucose meters are prone to physiological and analytical interferences, such as hematocrit variations, environmental conditions, presence of redox-active drugs, and enzymatic specificity issues. These interferences may lead to inaccurate glucose readings, impairing clinical decision-making, especially in intensive care and emergency settings. Moreover, discrepancies between capillary and venous glucose concentrations can contribute to misdiagnosis and inappropriate glycemic management. This review provides a comprehensive analysis of glucose measurement methodologies, their limitations, and potential improvements, emphasizing the need for preanalytical harmonization in laboratory testing and a better understanding of interferences in HPOC testing. Standardization of blood sample handling and adoption of optimized collection tubes could enhance glucose measurement reliability, ultimately improving diabetes diagnosis and patient outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Gaglia, J. L., Hilliard, M. E., Johnson, E. L., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s002 · Cited by 2,086 · cited 1×
“…of Laboratory Medicine (EFLM ) strongly recommend using venous plasma promptly separated within 30 min of collection, or collected into fluoride-citrate tubes when immediate centrifugation is not feasible, to ensure reliable glucose values and avoid spurious hypoglycemia due to glycolysis [22].”
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Cryer, P. E., Axelrod, L., Grossman, A. B., Heller, S. R., Montori, V. M., Seaquist, E. R., & Service, F. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1410 · Cited by 1,277 · cited 2×
“If left untreated, it can lead to severe complications, including infections, neurological impairment, coma, and death [1].”
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137 · cited 1×
“This method could be considered as the reference technique for measuring glucose in clinical laboratories [5].”
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 988
Hydrocortisone, Vitamin C, and Thiamine for the Treatment of Severe Sepsis and Septic Shock
Marik, P. E., Khangoora, V., Rivera, R., Hooper, M. H., & Catravas, J. (2017) · Chest · doi:10.1016/j.chest.2016.11.036 · Cited by 887
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344 · cited 1×
“Hemolysis leads to the release of hexokinase into plasma, which can impair glucose measurement by artificially decreasing its concentration with the reference hexokinase-based assay [18,34].”
Self-citationTang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Techniques to Monitor Glycolysis
TeSlaa, T., & Teitell, M. A. (2014) · Methods in Enzymology · doi:10.1016/b978-0-12-416618-9.00005-4 · Cited by 273
Tang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000) · American Journal of Clinical Pathology · doi:10.1309/qaw1-x5xw-bvrq-5lkq · Cited by 207
Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200105000-00038 · Cited by 188
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144 · cited 1×
“For glucose values >100 mg/dL (i.e. >5.55 mmol/L), 15% is the maximum allowed inaccuracy for 95% of the measures [59,60].”
InfluentialCGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring
Heinemann, L., & Freckmann, G. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815603528 · Cited by 126
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116 · cited 1×
“Both preanalytical and analytical factors can introduce variability, leading to discrepancies between measured and actual glucose statement [10].”
Self-citationAarsand, A. K., Díaz-Garzón, J., Fernandez-Calle, P., Guerra, E., Locatelli, M., Bartlett, W. A., Sandberg, S., Røraas, T., Ceriotti, F., Sølvik, U. Ø., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.288415 · Cited by 105 · cited 1×
“The European Biological Variation Study (EuBIVAS) provided rigorously controlled data on glucose, reporting a within-subject coefficient of variation (CVI) of 4.7% and between-subject variation (CVG) of 8.1%, both notably lower than previously published estimates [3].”
InfluentialGoyal, A., Gupta, Y., Singla, R., Kalra, S., & Tandon, N. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00865-3 · Cited by 105
Interference of Maltose, Icodextrin, Galactose, or Xylose with Some Blood Glucose Monitoring Systems
Schleis, T. G. (2007) · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.27.9.1313 · Cited by 102 · cited 3×
“Basically, free reduced groups on glucose (and structurally-related molecules) react on the test strip, with generation of electrons and electric current [81].”
InfluentialTang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-0577-eopogm · Cited by 92
An interference-free glucose biosensor based on a novel low potential redox polymer mediator
Deng, H., Teo, A. K. L., & Gao, Z. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.10.059 · Cited by 85
ISO 15197: 2013 Evaluation of a Blood Glucose Monitoring System’s Measurement Accuracy
Jendrike, N. R. M., Baumstark, A., Kamecke, U., Haug, C., & Freckmann, G. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817727550 · Cited by 83
Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction
Rao, L. V., Jakubiak, F., Sidwell, J. S., Winkelman, J. W., & Snyder, M. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.01.027 · Cited by 81
Hematocrit Interference of Blood Glucose Meters for Patient Self-Measurement
Ramljak, S., Lock, J. P., Schipper, C., Musholt, P. B., Forst, T., Lyon, M., & Pfützner, A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700123 · Cited by 72
Welsh, J. B., Gao, P., Derdzinski, M., Puhr, S., Johnson, T. K., Walker, T. C., & Graham, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0374 · Cited by 72
Martinello, F., & da Silva, E. L. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.05.012 · Cited by 65
Pidcoke, H. F., Wade, C. E., Mann, E. A., Salinas, J., Cohee, B. M., Holcomb, J. B., & Wolf, S. E. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181bc826f · Cited by 60
Hypoglycaemia related to inherited metabolic diseases in adults
Douillard, C., Mention, K., Dobbelaere, D., Wemeau, J.-L., Saudubray, J.-M., & Vantyghem, M.-C. (2012) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-7-26 · Cited by 60
Martinello, F., & da Silva, E. L. (2006) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.11.011 · Cited by 48
The Effects of Intravenous Vitamin C on Point-of-Care Glucose Monitoring
Sartor, Z., Kesey, J., & Dissanaike, S. (2015) · Journal of Burn Care & Research · doi:10.1097/bcr.0000000000000142 · Cited by 47
Keutmann, S., Zylla, S., Dahl, M., Friedrich, N., Landgraf, R., Heinemann, L., Kallner, A., Nauck, M. A., & Petersmann, A. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-00740-w · Cited by 46
Kahn, S. A., & Lentz, C. W. (2014) · Journal of Burn Care & Research · doi:10.1097/bcr.0000000000000141 · Cited by 45
A Simple and Effective Colorimetric Assay for Glucose Based on MnO2 Nanosheets
Huang, Z., Zheng, L., Feng, F., Chen, Y.-Y., Wang, Z., Lin, Z. Y., Lin, X., & Weng, S. (2018) · Sensors · doi:10.3390/s18082525 · Cited by 38
A review of blood glucose monitor accuracy
King, F., Ahn, D., Hsiao, V., Porco, T., & Klonoff, D. C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0232 · Cited by 37 · cited 2×
“A recent review article has analyzed the results of 58 studies published between the years 2010 and 2017, based on as many as 143 different glucose meters [62].”
Continuous Glucose Monitoring in the Intensive Care Unit
ARROYO, L. I. G., Faulds, E. R., Perez‐Guzman, M. C., Davis, G. M., Dungan, K. M., & Pasquel, F. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231169522 · Cited by 36
Battelino, T., Lalic, N. M., Hussain, S., Ceriello, A., Majanović, S. K., Davies, S., Topsever, P., Heverly, J., Ulivi, F., Brady, K., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112111 · Cited by 36
Our Scientific Journey through the Ups and Downs of Blood Glucose Control in the ICU
den Berghe, G. V., Vanhorebeek, I., Langouche, L., & Gunst, J. (2024) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202309-1696so · Cited by 35
Hematocrit compensation in electrochemical blood glucose monitoring systems
Teodorczyk, M., Cardosi, M., & Setford, S. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600320 · Cited by 33 · cited 1×
“Basically, a high hematocrit value is accompanied by enhanced blood viscosity, which may then interfere with capillary blood glucose measurement, typically causing artefac-tual hypoglycemia [71].”
Dickson, L. M., Buchmann, E., van Rensburg, C. J., & Norris, S. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43665-x · Cited by 33
Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial
Halldorsdottir, S., Warchal-Windham, M. E., Wallace, J. F., Pardo, S., Parkes, J. L., & Simmons, D. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700520 · Cited by 31
Dimeski, G., Jones, B. W., Tilley, V, Greenslade, M. N., & Russell, A. W. (2010) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2010.009291 · Cited by 31
Yu, X., Yang, Z., Sun, X., Liu, H., Li, H., Lu, J., Zhou, J. H., & Çınar, A. (2025) · AI · doi:10.3390/ai6050087 · Cited by 31
Diagnosis of gestational diabetes mellitus will be flawed until we can measure glucose
Bruns, D. E., Metzger, B. E., & Sacks, D. B. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz027 · Cited by 30 · cited 1×
“For gestational diabetes mellitus (GDM), the use of FC-Mix tubes could improve diagnostic accuracy by minimizing variability due to sample processing delays [42] but also could lead to overdi-agnosis.”
Comparison of glucose determinations on blood samples collected in three types of tubes.
Li, G., Cabanero, M., Wang, Z., Wang, H., Huang, T., Alexis, H., Eid, I., Muth, G., & Pincus, M. R. (2013) · PubMed · Cited by 29
Cembrowski, G. S., Tran, D. V., Slater-MacLean, L., Chin, D., Gibney, R. T. N., & Jacka, M. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.146217 · Cited by 29
Bilen, H., Kiliçaslan, A., Akcay, G., & Albayrak, F. (2007) · Journal of Medical Engineering & Technology · doi:10.1080/03091900600861590 · Cited by 28
Evaluation of the Nova StatStrip glucometer in a pediatric hospital setting
Lockyer, M. G., Fu, K. A., Edwards, R., Collymore, L., Thomas, J. A., Hill, T., & Devaraj, S. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.01.004 · Cited by 28
Blood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
Relative efficacy of different strategies for inhibition of in vitro glycolysis
Fischer, M. M., Hannemann, A., Winter, T., Schäfer, C., Petersmann, A., & Nauck, M. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab071 · Cited by 28
Jamieson, E. L., Dimeski, G., Flatman, R., Hickman, P. E., Jones, G. R. D., Marley, J. V., McIntyre, D. H., McNeil, A. R., Nolan, C. J., Potter, J. M., et al. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.10.002 · Cited by 28
Lyon, M. E., DuBois, J. A., Fick, G. H., & Lyon, A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400624 · Cited by 27
Technical and clinical validation of the Greiner FC-Mix glycaemia tube
van der Hagen, E. A. E., Fokkert, M. J., Kleefman, A. M. D., Thelen, M., van den Berg, S. A. A., & Slingerland, R. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0944 · Cited by 27
Pros and cons of continuous glucose monitoring in the intensive care unit
Sun, M.-T., Li, I.-C., Lin, W., & Lin, G. (2021) · World Journal of Clinical Cases · doi:10.12998/wjcc.v9.i29.8666 · Cited by 27
Carey, R., Lunt, H., Heenan, H. F., Frampton, C. M. A., & Florkowski, C. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.017 · Cited by 26
Evaluation of different POCT devices for glucose measurement in a clinical neonatal setting
Roth‐Kleiner, M., Stadelmann, C., Urfer, J., Ruffieux, C., & Werner, D. (2010) · European Journal of Pediatrics · doi:10.1007/s00431-010-1243-2 · Cited by 25
Hypoglycaemia caused by atypical insulin antibodies in a patient with benign monoclonal gammopathy
Arnqvist, H. J., Halban, P. A., Mathiesen, U., Zahnd, G. R., & von Schenck, H. (1993) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1993.tb00766.x · Cited by 25
Comparison of Accuracy Guidelines for Hospital Glucose Meters
Bowman, C. F., & Nichols, J. H. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819898277 · Cited by 24
Andreis, E., Küllmer, K., & Appel, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814523886 · Cited by 22
Bietenbeck, A., Geilenkeuser, W. J., Klawonn, F., Spannagl, M., Nauck, M., Petersmann, A., Thaler, M., Winter, C., & Luppa, P. B. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1142 · Cited by 22
Advances in invasive and non-invasive glucose monitoring: A review of microwave-based sensors
Alsultani, A. B., Kovács, K. J., Chase, J. G., & Benyó, B. I. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100332 · Cited by 22
Tran, N. K., Godwin, Z. R., Bockhold, J. C., Passerini, A. G., Cheng, J., & Ingemason, M. (2014) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e31829b3700 · Cited by 21
Stapleton, M., Daly, N., O’Kelly, R., & Turner, M. J. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216682978 · Cited by 21
Managing discordance between HbA 1c and glucose management indicator
Lenters‐Westra, E., Fokkert, M. J., Kilpatrick, E. S., Schleicher, E. D., Pilla, S. J., English, E., & van Dijk, P. R. (2025) · Diabetic Medicine · doi:10.1111/dme.70023 · Cited by 21
Factors interfering with the accuracy of five blood glucose meters used in Chinese hospitals
Lv, H., Zhang, G., Kang, X., Yuan, H., Lv, Y., Wang, W., & Randall, R. (2013) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21611 · Cited by 20
Grzych, G., Pekar, J. D., Curt, M. J.-C., Decoin, R., Vergriete, P., Henry, H., Odou, P., Maboudou, P., Brousseau, T., & Vamecq, J. (2021) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2021.03.007 · Cited by 20
Self-citationDaly, N., Flynn, I., Carroll, C., Stapleton, M., O'Kelly, R., & Turner, M. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2016.254466 · Cited by 19
Luna‐Záizar, H., Montelongo, M. V., Cortez-Álvarez, C. R., Ruíz-Quezada, S. L., Escutia-Gutiérrez, R., García-Lemus, C. R., & Mendizabal-Ruiz, A. P. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.01.007 · Cited by 19
Comparison of blood glucose meters in a New Zealand diabetes centre
Florkowski, C., Budgen, C., Kendall, D., Lunt, H., & Moore, M. P. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.008193 · Cited by 18
Lippi, G., Salvagno, G. L., Lampus, S. F., Danese, E., Gelati, M., Bovo, C., Montagnana, M., & Šimundić, A.-M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0523 · Cited by 18
Self-citationJendrike, N., Baumstark, A., Pleus, S., Liebing, C., Beer, A., Flacke, F., Haug, C., & Freckmann, G. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0391 · Cited by 17
Bonetti, G., Giavarina, D., & Carta, M. (2019) · Diagnosis · doi:10.1515/dx-2018-0100 · Cited by 17
Perez‐Ayala, M., Oliver, P., & Cantalejo, F. R. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700407 · Cited by 16
Evaluating Interference of Lipemia on Routine Clinical Biochemical Tests
Arulvijayavani, S., Mohanraj, P. S., & Rajagambeeram, R. (2022) · Journal of Laboratory Physicians · doi:10.1055/s-0042-1758664 · Cited by 16
Definition of icteric interference index for six biochemical analytes
Cano‐Corres, R., Solé-Enrech, G., & Aparicio-Calvente, M. I. (2023) · Biochemia Medica · doi:10.11613/bm.2023.020702 · Cited by 16
Fournier, J. E., Northrup, V., Clark, C., Fraser, J. M., Howlett, M. P., Atkinson, P., & Shea, J. L. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.06.002 · Cited by 15
Juričić, G., Saračević, A., Kopčinović, L. M., Bakliža, A., & Šimundić, A.-M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.03.006 · Cited by 14
Galindo, R. J., Moazzami, B., Gerges, A., FLORES, I. C., Arevalo, G., Peng, L., Tuttle, K. R., & Umpierrez, G. E. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf187 · Cited by 14
Saračević, A., Dukić, L., Juričić, G., Kopčinović, L. M., Mirošević, G., & Šimundić, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0279 · Cited by 13
Grzych, G., Roland, E., Beauvais, D., et al. (2019) · Journal of Medical Biochemistry · doi:10.2478/jomb-2019-0005 · Cited by 12
Self-citationBerge, D. T., Muller, W., Beishuizen, A., Cornet, A. D., Slingerland, R. J., & Krabbe, J. G. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1445 · Cited by 10
Overcoming preanalytical issues for diagnosing diabetes with fasting plasma glucose
Montagnana, M., & Lippi, G. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.05.19 · Cited by 9
Self-citationBalboni, F., Burbui, S., & Lippi, G. (2018) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1517221 · Cited by 9
Self-citationClinical impact of artifactual hypoglycaemia and its diagnosis at the bedside
Drenthen, L. C. A., Verheggen, R. J. H. M., & de Galan, B. E. (2019) · Lara D. Veeken · doi:10.1093/rheumatology/kez118 · Cited by 9
Effects of different tube types on patient classification using current diabetes decision limits
Orth, M., Hawran, H., Ulloor, J., Bachhawat, K., & Lennartz, L. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00134 · Cited by 9
Real-time Continuous Glucose Monitoring in the Intensive Care Unit: The Fifth Vital Sign
Patham, B., Kansara, A., & Sadhu, A. (2024) · Diabetes Care · doi:10.2337/dci24-0020 · Cited by 9
Ataç, Ö., Heier, K., Moga, D. C., Fowlkes, J. L., Sohn, M., Kruse‐Diehr, A. J., Waters, T. M., & LACY, M. E. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-088785 · Cited by 9
Pseudo-hypoglycémie et hyperleucocytose: à propos d'un cas
Nourrisson, C., Batisse‐Lignier, M., Sapin, V., & Bouvier, D. (2010) · Annales de biologie clinique · doi:10.1684/abc.2010.0455 · Cited by 7
Reducing Treatment Errors Through Point-of-Care Glucometer Configuration
Estock, J. L., Pham, I. T., Curinga, H. K., Sprague, B. J., Boudreaux-Kelly, M. Y., Acevedo, J., & Jacobs, K. (2018) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2018.03.014 · Cited by 7
Xu, N. Y., Nguyen, K. T., Mehta, C., & Klonoff, D. C. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211041328 · Cited by 7
Deviating glucose results in an international dual-center study. A root cause investigation
Bergsten, P., Bergquist, J., Cadamuro, J., Weghuber, D., Jabbour, J., Brunner, S. M., Ciba, I., Dahlbom, M., Mörwald, K., & Forslund, A. H. (2021) · Biochemia Medica · doi:10.11613/bm.2022.011001 · Cited by 7
Interference Reduction in Glucose Detection by Redox Potential Tuning: New Glucose Meter Development
Cho, S. J., Cho, C.-H., Kim, K. B., Lee, M.-H., Kim, J. H., Lee, S.-H., Cho, J., Jung, S., Kim, D., & Shim, Y. (2015) · Analytical Sciences · doi:10.2116/analsci.31.705 · Cited by 6
Better Glucose Stability in Serum than in Plasma Samples after 12-h Stay at Room Temperature
Grzych, G., Pekar, J. D., & Maboudou, P. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0061 · Cited by 6
Self-citationMaintaining glucose integrity ex-vivo: Impact of preanalytical specimen handling
Islam, M. N., Lyons, C., Griffin, T. P., Hamon, S., Dunne, F., & O’Shea, P. M. (2023) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632231199374 · Cited by 6
Resolution of dysglycaemia after treatment of monoclonal gammopathy of endocrine significance
Grant, B., Ratnayake, G. M., Williams, C. L., Long, A. E., Halsall, D. J., Semple, R. K., Cavenagh, J. D., Drake, W. M., & Church, D. (2023) · European Journal of Endocrinology · doi:10.1093/ejendo/lvad138 · Cited by 6
Bakkebø, H., Haaland, K. L., Hoff, K. S., & Schwettmann, L. (2024) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2024.2318617 · Cited by 5
Nevraumont, A., Deltombe, M., & Bayart, J. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119875 · Cited by 4
The difference between reference interval and reference range
Haeckel, R., Wosniok, W., & Streichert, T. (2020) · Journal of Laboratory Medicine · doi:10.1515/labmed-2019-0192 · Cited by 3
Case Report: Artifactual Hypoglycemia: A Condition That Should Not Be Forgotten
Amaral, S., Palha, A. M., Bernardino, V., & Silva‐Nunes, J. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.951377 · Cited by 3
Traitement nutritionnel du grand brûlé
Berger, M. M., & Que, Y. (2009) · Réanimation · doi:10.1016/j.reaurg.2009.09.001 · Cited by 2
Glucose(monitoring): from bench to real world experiences
Fokkert, M. J. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.207217778 · Cited by 2
Automated Insulin Delivery during Pregnancy Complicated by Type 1 Diabetes
Lee, T. T. M., Bergford, S., & Murphy, H. R. (2024) · New England Journal of Medicine · doi:10.1056/nejmc2313410 · Cited by 1
Research works printed but not linked: 3
- 10.1043/1543-2165(2005)129<454b:PWMIM>2.0.CO;2 · doi:10.1043/1543-2165(2005)129
- NICE, Guideline. Diabetes in pregnancy: management from preconception to the postnatal period. Diabetes Pregnancy. 2020.
- Figure 3. Parks error grid plot. The x-axis represents blood glucose…. [cited 2025 Jun 19]. Available from https://www.researchgate.net/figure/Parks-Error-Grid-Plot-The-x-axis-represents-blood-glucose-concentrations-derived-from_fig2_356925783
Metadata
- Authors
- Grzych, G., Defauwes, I., de Tullio, P., Pekar, J. D., Brousseau, T., Lippi, G., & Cavalier, E.
- Venue
- Critical Reviews in Clinical Laboratory Sciences
- Publisher
- Informa UK Limited
- Published
- 2025-07-26
- Volume
- 62
- Issue
- 8
- Pages
- 613-630
- ISSN
- 1040-8363
- 1549-781X
- Cited by
- 4
- References
- 104
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.