Insertion of linear 8.4 μ m diameter 16 channel carbon fiber electrode arrays for single unit recordings
Open accessThe DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Single carbon fiber electrodes (d = 8.4 μm) insulated with parylene-c and functionalized with PEDOT: pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ∼150 μm pitch. APPROACH: Two approaches were tested for the insertion of carbon fiber arrays. The first method used a poly(ethylene glycol) (PEG) coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm-1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. MAIN RESULTS: Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in five rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in three acute rat surgeries. In one of those surgeries a stacked device with three layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. SIGNIFICANCE: From these studies we have found that carbon fibers spaced at ∼150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963 · cited 1×
“Next, a 2 × 3 mm craniotomy was made over the right hemisphere’s motor cortex using coordinates from a reference atlas [66].”
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., Watson, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,497
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136 · cited 1×
“Packaging arrays with an ASIC capable of multiplexing hundreds of channels [93] would alleviate many wiring issues [2, 94] or completely eliminate them [95–97].”
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796 · cited 2×
“An implanted neural probe continually disrupts local vasculature due to micromotion and mechanical strain [31, 32] leading to the constant release of inflammatory agents [18, 20, 26, 28, 30, 33–35] that perpetuates the local reactive response (see [37] for review).”
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Self-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Self-citationFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · cited 2×
“An implanted neural probe continually disrupts local vasculature due to micromotion and mechanical strain [31, 32] leading to the constant release of inflammatory agents [18, 20, 26, 28, 30, 33–35] that perpetuates the local reactive response (see [37] for review).”
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Armstrong-James, M., & Millar, J. (1979) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(79)90039-6 · Cited by 382 · cited 2×
“[53].”
Three-dimensional growth and function of neural tissue in degradable polyethylene glycol hydrogels
Mahoney, M. J., & Anseth, K. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.007 · Cited by 377
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Parylene flexible neural probes integrated with microfluidic channels
Takeuchi, S., Ziegler, D., Yoshida, Y., Mabuchi, K., & Suzuki, T. (2005) · Lab on a Chip · doi:10.1039/b417497f · Cited by 364
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialResolving Neurotransmitters Detected by Fast-Scan Cyclic Voltammetry
Heien, M. L. A. V., Johnson, M. A., & Wightman, R. M. (2004) · Analytical Chemistry · doi:10.1021/ac0491509 · Cited by 354
A realistic brain tissue phantom for intraparenchymal infusion studies
Chen, Z.-J., Gillies, G. T., Broaddus, W. C., Prabhu, S. S., Fillmore, H., Mitchell, R. M., Corwin, F. D., & Fatouros, P. P. (2004) · Journal of Neurosurgery · doi:10.3171/jns.2004.101.2.0314 · Cited by 322
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J., & Nurmikko, A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 321
Large-scale, high-density (up to 512 channels) recording of local circuits in behaving animals
Berényi, A., Somogyvári, Z., Nagy, A. J., Roux, L., Long, J. D., Fujisawa, S., Stark, E., Leonardo, A., Harris, T. D., & Buzsáki, G. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00785.2013 · Cited by 311 · cited 2×
“The ability to record simultaneous neural activity from large neuronal populations has had a far reaching impact in the fields of neuroscience [1, 2] and neural prosthetics, including brain machine interfaces (BMIs) [3–5].”
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation
Luo, X., Weaver, C. L., Zhou, D. D., Greenberg, R., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.051 · Cited by 252
Imaging cerebral blood flow through the intact rat skull with temporal laser speckle imaging
Li, P., Ni, S., Zhang, L., Zeng, S., & Luo, Q. (2006) · Optics Letters · doi:10.1364/ol.31.001824 · Cited by 249
Accelerated aging for testing polymeric biomaterials and medical devices
Hukins, D. W. L., Mahomed, A., & Kukureka, S. N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.001 · Cited by 247 · cited 1×
“According to works by Green et al [63] and Hukins et al [64], equation (1) can be used to determine simulated aging time that the fibers have undergone:”
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245 · cited 1×
“After thorough organic/ionic cleaning, the silicon wafer was highly doped (>10(19) cm) up to ∼12 μm in depth by deep boron doping and diffusion (figure 3(b)), which is similar to the methods and dimensions seen in other silicon electrode technologies [9, 68, 69].”
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Encapsulation of an Integrated Neural Interface Device With Parylene C
Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
Potter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 239
Rebec, G. V., Christensen, J. R. C., Guerra, C., & Bardo, M. T. (1997) · Brain Research · doi:10.1016/s0006-8993(97)01004-4 · Cited by 235
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224
Kozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialSelf-citationKozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215
Self-citationSubstrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J. F., Dodds, C. W., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 205
Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 201 · cited 2×
“[12, 14, 74, 75] 400 μm 90× 90 μm at base, 5 μm tip diameter 40 μm tapering”
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
Self-citationKozai, T. D. Y., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.08.002 · Cited by 190
Self-citationMechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
Harris, J. P., Capadona, J. R., Miller, R. H., Healy, B. C., Shanmuganathan, K., Rowan, S. J., Weder, C., & Tyler, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066011 · Cited by 190
HermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 $\mu$m CMOS
Gao, H., Walker, R. M., Nuyujukian, P., Makinwa, K. A. A., Shenoy, K. V., Murmann, B., & Meng, T. H. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185338 · Cited by 189
Kozai, T. D. Y., Marzullo, T. C., Hooi, F., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046011 · Cited by 184
Self-citationBiocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 183
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Winslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Park, J., Takmakov, P. A., & Wightman, R. M. (2011) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2011.07494.x · Cited by 171
Model-based analysis of cortical recording with silicon microelectrodes
Moffitt, M. A., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.018 · Cited by 170
Miranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161 · cited 1×
“Packaging arrays with an ASIC capable of multiplexing hundreds of channels [93] would alleviate many wiring issues [2, 94] or completely eliminate them [95–97].”
Self-citation3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155
In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes
Harris, J. P., Hess, A. E., Rowan, S. J., Weder, C., Zorman, C. A., Tyler, D. J., & Capadona, J. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046010 · Cited by 151 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialKozai, T. D. Y., & Vazquez, A. L. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00108k · Cited by 150
Self-citationWark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148
Ware, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialKozai, T. D. Y., Du, Z., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L. M., Caparosa, E. M., Friedlander, R. M., & Cui, X. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.010 · Cited by 138
Self-citationXie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Self-citationKolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
Self-citationThiol‐ene/acrylate substrates for softening intracortical electrodes
Ware, T., Simon, D., Liu, C., Musa, T., Vasudevan, S., Sloan, A., Keefer, E. W., Rennaker, R. L., & Voit, W. (2014) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbmb.32946 · Cited by 126
Desai, S. A. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00005 · Cited by 126
Bjornsson, C. S., Lin, G., Al‐Kofahi, Y., Narayanaswamy, A., Smith, K. L., Shain, W. G., & Roysam, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.12.024 · Cited by 118
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Azemi, E., Stauffer, W. R., Gostock, M. S., Lagenaur, C. F., & Cui, X. T. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.028 · Cited by 97
Wafer-Level Parylene Packaging With Integrated RF Electronics for Wireless Retinal Prostheses
Li, W., Rodger, D. C., Meng, E. F., Weiland, J. D., Humayun, M. S., & Tai, Y. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049985 · Cited by 96 · cited 1×
“The longevity of both have been explored by a few groups, some using soak test methods [62, 63, 79] and others using data from chronic implants [14, 80], but no definitive conclusions have been reached.”
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
Johnson, M. D., Kao, O. E., & Kipke, D. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.023 · Cited by 94
Sankar, V., Patrick, E., Dieme, R., Sanchez, J. C., Prasad, A., & Nishida, T. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00013 · Cited by 89
Ferris, M. J., Calipari, E. S., Yorgason, J. T., & Jones, S. R. (2013) · ACS Chemical Neuroscience · doi:10.1021/cn400026v · Cited by 89
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, C. L., Luebben, S. D., Sapp, S. A., Hanner, J., Snyder, N., Kozai, T. D. Y., Chang, E., Nabity, J. A., Nabity, S. T., Lagenaur, C. F., et al. (2015) · Soft Matter · doi:10.1039/c5sm00174a · Cited by 88
Self-citationMandal, H. S., Knaack, G. L., Charkhkar, H., McHail, D. G., Kastee, J. S., Dumas, T. C., Peixoto, N., Rubinson, J. F., & Pancrazio, J. J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.029 · Cited by 81
Short and long term biocompatibility of NeuroProbes silicon probes
Grand, L., Wittner, L., Herwik, S., Göthelid, E., Ruther, P., Oscarsson, S. O., Neves, H. P., Dombovári, B., Csercsa, R., Karmos, G., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.009 · Cited by 74 · cited 1×
“This reactive response is best characterized by a glial sheath or scar, surrounding the probe, composed of activated astrocytes and microglia [18, 21–31].”
An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle
Gilgunn, P. J., Khilwani, R., Kozai, T. D. Y., Weber, D. J., Cui, X. T., Erdos, G., Ozdoganlar, O. B., & Fedder, G. K. (2012) · 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170092 · Cited by 65
Self-citationHighly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS
McClain, M. A., Clements, I. P., Shafer, R. H., Bellamkonda, R. V., LaPlaca, M. C., & Allen, M. G. (2011) · Biomedical Microdevices · doi:10.1007/s10544-010-9505-3 · Cited by 63 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialKatira, P., Agarwal, A., Fischer, T., Chen, H.-Y., Jiang, X., Lahann, J., & Hess, H. (2007) · Advanced Materials · doi:10.1002/adma.200701982 · Cited by 57 · cited 1×
“If current methods are found to be non-ideal there are a variety of other insulating [81, 82] and conductive [83–86] coating methods available (see [87] for review).”
The existence of a layer IV in the rat motor cortex
Skoglund, T. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.2.178 · Cited by 50
Nanostructured Coatings for Improved Charge Delivery to Neurons
Kozai, T. D. Y., Alba, N. A., Zhang, H., Kotov, N. A., Gaunt, R. A., & Cui, X. T. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_4 · Cited by 48
Self-citationRennaker, R. L., Ruyle, A. M., Street, S. E., & Sloan, A. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.07.018 · Cited by 35
Multiple single-unit recordings from the CNS using thin-film electrode arrays
Carter, R. R., & Houk, J. C. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.279266 · Cited by 34
Microactuated neural probes to compensate for brain micromotion
Muthuswamy, J., Gilletti, A., Jain, T., & Okandan, M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279819 · Cited by 29 · cited 1×
“S Online supplementary data available from stacks.iop.org/JNE/12/046009/mmedia Keywords: carbon electrodes, neural probes, microelectrodes, MEAs (Some figures may appear in colour only in the online journal) 1741-2560/15/046009+18$33.00 © 2015 IOP Publishing Ltd Printed in the UK1”
InfluentialAn alginate hydrogel dura mater replacement for use with intracortical electrodes
Nunamaker, E. A., & Kipke, D. R. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31733 · Cited by 25
Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices
F02 Committee (2011) · ASTM Standards · doi:10.1520/f1980-07r11 · Cited by 5
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Self-citationNext-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Elastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
“2019;5 : eaav2842 27 March 2019 dissolved by body fluids in the brain tissue (41), and the Neurotassels were released and transformed back to highly flexible microelectrode filaments (fig.”
BackgroundUltrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Self-citation
Metadata
- Authors
- Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2015-06-02
- Volume
- 12
- Issue
- 4
- Pages
- 046009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1527745297
- Cited by
- 162
- References
- 93
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.