Spatial Localization in NMR Spectroscopy in Vivo
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Spatial localization techniques are necessary for in vivo NMR spectroscopy involving heterogeneous organisms. Localization by surface coil NMR detection alone is generally inadequate for deep-lying organs due to contaminating signals from intervening surface tissues. However, localization to preselected planar volumes can be accomplished using a single selective excitation pulse in the presence of a pulsed magnetic field gradient, yielding depth-resolved surface coil spectra (DRESS). Within selected planes, DRESS are spatially restricted by the surface coil sensitivity profiles to disk-shaped volumes whose radii increase with depth, notwithstanding variations in the NMR signal density distribution. Nevertheless, DRESS is a simple and versatile localization procedure that is readily adaptable to spectral relaxation time measurements by adding inversion or spin-echo refocusing pulses or to in vivo solvent-suppressed spectroscopy of proton (1H) metabolites using a combination of chemical-selective RF pulses. Also, the spatial information gathering efficiency of the technique can be improved to provide simultaneous acquisition of spectra from multiple volumes by interleaving excitation of adjacent planes within the normal relaxation recovery period. The spatial selectivity can be improved by adding additional selective excitation spin-echo refocusing pulses to achieve full, three-dimensional point resolved spectroscopy (PRESS) in a single excitation sequence. Alternatively, for samples with short spin-spin relaxation times, DRESS can be combined with other localization schemes, such as image-selected in vivo spectroscopy (ISIS), to provide complete gradient controlled three-dimensional localization with a reduced number of sequence cycles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of Intracellular pH by 31P Magnetic Resonance
Moon, R. B., & Richards, J. H. (1973) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)43389-9 · Cited by 1,189
Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811
High-resolution 1H nuclear magnetic resonance study of cerebral hypoxia in vivo.
Behar, K. L., den Hollander, J. A., Stromski, M. E., Ogino, T., Shulman, R. G., Petroff, O. A., & Prichard, J. W. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.16.4945 · Cited by 292
Depth-resolved surface-coil spectroscopy (DRESS) for in Vivo 1H, 31P, and 13C NMR
Bottomley, P. A., Foster, T. B., & Darrow, R. D. (1984) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(84)90179-3 · Cited by 290
Self-citationSelective population inversion in NMR
Silver, M. S., Joseph, R. I., Chen, C.-N., Sank, V. J., & Hoult, D. I. (1984) · Nature · doi:10.1038/310681a0 · Cited by 205
Noninvasive, nondestructive approaches to cell bioenergetics.
Chance, B., Eleff, S., & Leigh, J. S. (1980) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.77.12.7430 · Cited by 154
4480228 Selective volume method for performing localized NMR spectroscopy
Bottomley, P. A. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90032-3 · Cited by 151
Self-citationBottomley, P. A., Edelstein, W. A., Foster, T. H., & Adams, W. A. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.7.2148 · Cited by 133
Self-citationSpatial localization in 31P and 13C NMR spectroscopy in Vivo using surface coils
Bottomley, P. A., Edelstein, W. A., Hart, H. R., Jr., Schenck, J. F., & Smith, L. S. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010311 · Cited by 39
Self-citation
Cited by
(1997) · Obesity Surgery · doi:10.1381/096089297765555359 · Cited by 3,916
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Magnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
Studies of human tumors by MRS: A review
Negendank, W. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050518 · Cited by 660
Schizophrenia: glutathione deficit in cerebrospinal fluid and prefrontal cortex in vivo
Do, K. Q., Trabesinger, A. H., Kirsten‐Krüger, M., Lauer, C. J., Dydak, U., Hell, D., Holsboer, F., Boesiger, P., & Cuénod, M. (2000) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2000.00229.x · Cited by 540
Neuroprotective Effects of Creatine in a Transgenic Mouse Model of Huntington's Disease
Ferrante, R. J., Andreassen, O. A., Jenkins, B. G., Dedeoglu, A., Kuemmerle, S., Kubilus, J. K., Kaddurah-Daouk, R., Hersch, S. M., & Beal, M. F. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-12-04389.2000 · Cited by 522
Magnetic Resonance Imaging: Principles and Techniques: Lessons for Clinicians
Grover, V. P. B., Tognarelli, J. M., Crossey, M. M. E., Cox, I. J., Taylor-Robinson, S. D., & McPhail, M. J. W. (2015) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2015.08.001 · Cited by 510
Thalamic neurodegeneration in multiple sclerosis
Cifelli, A., Arridge, M., Jezzard, P., Esiri, M. M., Palace, J., & Matthews, P. M. (2002) · Annals of Neurology · doi:10.1002/ana.10326 · Cited by 490
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Häussinger, D., Laubenberger, J., Vom Dahl, S., Ernst, T., Bayer, S., Langer, M., Gerok, W., & Hennig, J. (1994) · Gastroenterology · doi:10.1016/0016-5085(94)90552-5 · Cited by 415
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
In vivo magnetic resonance spectroscopy of GABA: A methodological review
Puts, N. A. J., & Edden, R. A. E. (2012) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2011.06.001 · Cited by 393
Proton MR spectroscopy in quantitative in vivo determination of fat content in human liver steatosis
Longo, R., Pollesello, P., Ricci, C., Masutti, F., Kvam, B. J., Bercich, L., Croce, L. S., Grigolato, P., Paoletti, S., De Bernard, B., et al. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050311 · Cited by 387
ROSENBERG, D. R., MacMASTER, F. P., KESHAVAN, M. S., FITZGERALD, K. D., STEWART, C. M., & MOORE, G. J. (2000) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-200009000-00008 · Cited by 377
“5-T MRI scanner using a short-echo single-voxel double spin-echo point resolved spectroscopy (PRESS) pulse sequence (Bottomley, 1987) from a 0.”
MethodEvidence for long-term neurotoxicity associated with methamphetamine abuse: A 1H MRS study
Ernst, T., Chang, L., Leonido–Yee, M., & Speck, O. (2000) · Neurology · doi:10.1212/wnl.54.6.1344 · Cited by 373
Simpson, R., Devenyi, G. A., Jezzard, P., Hennessy, T. J., & Near, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26091 · Cited by 368
Bajaj, M., Suraamornkul, S., Piper, P., Hardies, L. J., Glass, L., Cersosimo, E., Pratipanawatr, T., Miyazaki, Y., & DeFronzo, R. A. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031315 · Cited by 358
Imaging of Brain Tumors: MR Spectroscopy and Metabolic Imaging
Horská, A., & Barker, P. B. (2010) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2010.04.003 · Cited by 356
Schick, F., Eismann, B., Jung, W., Bongers, H., Bunse, M., & Lutz, O. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290203 · Cited by 349
Vagnozzi, R., Signoretti, S., Tavazzi, B., Floris, R., Ludovici, A., Marziali, S., Tarascio, G., Amorini, A. M., Di Pietro, V., Delfini, R., et al. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316421.58568.ad · Cited by 349
Mekle, R., Mlynárik, V., Gambarota, G., Hergt, M., Krueger, G., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21961 · Cited by 324
Pope, W. B., Prins, R. M., Albert Thomas, M., Nagarajan, R., Yen, K. E., Bittinger, M. A., Salamon, N., Chou, A. P., Yong, W. H., Soto, H., et al. (2012) · Journal of Neuro-Oncology · doi:10.1007/s11060-011-0737-8 · Cited by 318
“Single-voxel localized MR spectra were acquired using the double-echo PRESS sequence [13].”
Imaging-based Quantification of Hepatic Fat: Methods and Clinical Applications
Ma, X., Holalkere, N.-S., R, A. K., Mino-Kenudson, M., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.295085186 · Cited by 312
Horder, J., Petrinovic, M. M., Mendez, M. A., Bruns, A., Takumi, T., Spooren, W., Barker, G. J., Künnecke, B., & Murphy, D. G. (2018) · Translational Psychiatry · doi:10.1038/s41398-018-0155-1 · Cited by 309
Tavazzi, B., Vagnozzi, R., Signoretti, S., Amorini, A. M., Finocchiaro, A., Cimatti, M., Delfini, R., Di Pietro, V., Belli, A., & Lazzarino, G. (2007) · Neurosurgery · doi:10.1227/01.neu.0000255525.34956.3f · Cited by 294
Scheenen, T. W. J., Klomp, D. W. J., Wijnen, J. P., & Heerschap, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21302 · Cited by 293
Bajaj, M., Suraamornkul, S., Pratipanawatr, T., Hardies, L. J., Pratipanawatr, W., Glass, L., Cersosimo, E., Miyazaki, Y., & DeFronzo, R. A. (2003) · Diabetes · doi:10.2337/diabetes.52.6.1364 · Cited by 290
Hippocampal and entorhinal cortex atrophy in frontotemporal dementia and Alzheimer’s disease
Frisoni, G. B., Laakso, M. P., Beltramello, A., Geroldi, C., Bianchetti, A., Soininen, H., & Trabucchi, M. (1999) · Neurology · doi:10.1212/wnl.52.1.91 · Cited by 285
Janik, R., Thomason, L. A. M., Stanisz, A. M., Forsythe, P., Bienenstock, J., & Stanisz, G. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.018 · Cited by 283
“The 1D PRESS spectra were fit using TARQUIN (Wilson et al., 2010), the generated basis set.”
MethodInfluentialIn vivo magnetic resonance spectroscopy: basic methodology and clinical applications
van der Graaf, M. (2010) · European Biophysics Journal · doi:10.1007/s00249-009-0517-y · Cited by 275
Localized short‐echo‐time proton MR spectroscopy with full signal‐intensity acquisition
Mlynárik, V., Gambarota, G., Frenkel, H., & Gruetter, R. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21043 · Cited by 274
In Vivo Magnetic Resonance Spectroscopy in Cancer
Gillies, R. J., & Morse, D. L. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100411 · Cited by 261
Advancements in MR Imaging of the Prostate: From Diagnosis to Interventions
Bonekamp, D., Jacobs, M. A., El-Khouli, R., Stoianovici, D., & Macura, K. J. (2011) · RadioGraphics · doi:10.1148/rg.313105139 · Cited by 254
Recent advances in parallel imaging for MRI
Hamilton, J., Franson, D., & Seiberlich, N. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.04.002 · Cited by 251
Träber, F., Block, W., Lamerichs, R., Gieseke, J., & Schild, H. H. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20053 · Cited by 249
Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling
Reeder, S. B., Robson, P. M., Yu, H., Shimakawa, A., Hines, C. D., McKenzie, C. A., & Brittain, J. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21751 · Cited by 248
“For comparison with IDEAL, a single-voxel breathheld spectroscopic acquisition was performed using point resolved spectroscopy (PRESS) (42), without water suppression to measure a localized hepatic fat-fraction.”
MethodROSENBERG, D. R., MIRZA, Y., RUSSELL, A., TANG, J., SMITH, J. M., BANERJEE, S. P., BHANDARI, R., ROSE, M., IVEY, J., BOYD, C., et al. (2004) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/01.chi.0000132812.44664.2d · Cited by 246
Hegde, J. V., Mulkern, R. V., Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23860 · Cited by 241
“As a result, water suppression pulses must be applied prior to the three, orthogonal slab-selective pulses which define the PRESS box (59).”
BackgroundObservation of a fast response in functional MR
Ernst, T., & Hennig, J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320122 · Cited by 240
Polymorphism of the PEMT gene and susceptibility to nonalcoholic fatty liver disease (NAFLD)
Song, J., Da Costa, K. A., Fischer, L. M., Kohlmeier, M., Kwock, L., Wang, S., & Zeisel, S. H. (2005) · The FASEB Journal · doi:10.1096/fj.04-3580com · Cited by 239
“Relative changes in the levels of fat and water were monitored using a localized single volume proton magnetic resonance spectroscopy technique (PRESS; TE 135, TR 1500 ms) (24).”
MethodYablonskiy, D. A., Ackerman, J. J. H., & Raichle, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.13.7603 · Cited by 239
Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer
Tran, T.-K. C., Vigneron, D. B., Sailasuta, N., Tropp, J., Le Roux, P., Kurhanewicz, J., Nelson, S., & Hurd, R. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200001)43:1<23::aid-mrm4>3.0.co;2-e · Cited by 238
“The VSS pulses were inserted just before the PRESS excitation pulses (22) in the modified PRESS-CSI sequence that we have been using for clinical MRSI studies of brain and prostate cancer (25,26).”
MethodDecreased hippocampal N-acetylaspartate in the absence of atrophy in posttraumatic stress disorder
Schuff, N., Neylan, T. C., Lenoci, M. A., Du, A.-T., Weiss, D. S., Marmar, C. R., & Weiner, M. W. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(01)01245-8 · Cited by 237
Cerebral metabolite abnormalities correlate with clinical severity of HIV-1 cognitive motor complex
Chang, L., Ernst, T., Leonido-Yee, M., Walot, I., & Singer, E. (1999) · Neurology · doi:10.1212/wnl.52.1.100 · Cited by 235
Age- and sex-specific differences in the1H-spectrum of vertebral bone marrow
Kugel, H., Jung, C., Schulte, O., & Heindel, W. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<263::aid-jmri1038>3.0.co;2-m · Cited by 229
“After spectroscopic preparations (shimming, gradient tuning), this volume was examined spectroscopically using the PRESS sequence (19,20) without water suppression (acquisition parameters: TR/TE 2000/40 msec, bandwidth 1 kHz, number of acquired data points 512, spectral resolution 1.”
MethodHighly active antiretroviral therapy reverses brain metabolite abnormalities in mild HIV dementia
Chang, L., Ernst, T., Leonido–Yee, M., Witt, M., Speck, O., Walot, I., & Miller, E. N. (1999) · Neurology · doi:10.1212/wnl.53.4.782 · Cited by 226
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“13) by applying selective radiofrequency excitation pulses such as stimulated echo acquisition mode (86) or point-resolved spectroscopy (87,88).”
BackgroundIncreased Anterior Cingulate/Medial Prefrontal Cortical Glutamate and Creatine in Bipolar Depression
Frye, M. A., Watzl, J., Banakar, S., O'Neill, J., Mintz, J., Davanzo, P., Fischer, J., Chirichigno, J. W., Ventura, J., Elman, S., et al. (2007) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301387 · Cited by 222
“PRESS was acquired with the GE proton brain examination (PROBE) technique, whereby four unsuppressed water free-induction decays were co-acquired for eddy current compensation, phase-correction, and normalization of local absolute metabolite levels.”
InfluentialThe neurochemical profile quantified by in vivo 1H NMR spectroscopy
Duarte, J. M. N., Lei, H., Mlynárik, V., & Gruetter, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.038 · Cited by 221
“PRESS is based on a slice selective excitation, which is followed by two frequency selective-refocusing pulses, a so-called double spin echo method (Bottomly, 1984, 1987).”
In vivo proton magnetic resonance spectroscopy of the normal aging human brain
Chang, L., Ernst, T., Poland, R. E., & Jenden, D. J. (1996) · Life Sciences · doi:10.1016/0024-3205(96)00197-x · Cited by 220
Wu, Y., Lu, Y.-C., Jacobs, M., Pradhan, S., Kapse, K., Zhao, L., Niforatos-Andescavage, N., Vezina, G., du Plessis, A. J., & Limperopoulos, C. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.19940 · Cited by 218
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
Moonen, C. T. W., Kienlin, M. V., Van Zijl, P. C. M., Cohen, J., Gillen, J., Daly, P., & Wolf, G. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 216
Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21809 · Cited by 215
“The two main (1)H MRS sequences used to measure liver fat are PRESS (point resolved spectroscopy) (8) and STEAM (stimulated echo acquisition mode) (9,10).”
MethodHu, H. H., Kim, H., Nayak, K. S., & Goran, M. I. (2010) · Obesity · doi:10.1038/oby.2009.352 · Cited by 212
“single-voxel proton Mrs In this work, the point-resolved spectroscopy method was utilized (27).”
Ethofer, T., Mader, I., Seeger, U., Helms, G., Erb, M., Grodd, W., Ludolph, A., & Klose, U. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10640 · Cited by 211
“The same point-resolved spectroscopy (PRESS) sequence (12) with a TE of 30 ms was used at both scanners.”
MethodMichaeli, S., Garwood, M., Zhu, X., DelaBarre, L., Andersen, P., Adriany, G., Merkle, H., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10135 · Cited by 198
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
“Most methods use single-voxel spectroscopy approaches such as point-resolved spectroscopy (PRESS) [113] or stimulated- Fig.”
MethodA technique for in vivo mapping of myocardial creatine kinase metabolism
Haris, M., Singh, A., Cai, K., Kogan, F., McGarvey, J., DeBrosse, C., Zsido, G. A., Witschey, W. R. T., Koomalsingh, K., Pilla, J. J., et al. (2014) · Nature Medicine · doi:10.1038/nm.3436 · Cited by 196
Floeth, F. W., Pauleit, D., Wittsack, H.-J., Langen, K. J., Reifenberger, G., Hamacher, K., Messing-Jünger, M., Zilles, K., Weber, F., Stummer, W., et al. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.102.2.0318 · Cited by 193
de la Fuente, M. I., Young, R. J., Rubel, J., Rosenblum, M., Tisnado, J., Briggs, S., Arevalo-Perez, J., Cross, J. R., Campos, C., Straley, K., et al. (2016) · Neuro-Oncology · doi:10.1093/neuonc/nov307 · Cited by 193
Chang, L., Ernst, T., Witt, M. D., Ames, N., Gaiefsky, M., & Miller, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1254 · Cited by 190
“Three volumesof-interest (or voxels) were selected for MRS: frontal gray matter, frontal white matter, and basal ganglia (Fig. 1). Data were acquired using a point-resolved spectroscopy (PRESS) sequence ( Bottomley, 1987 ), which provided optimal parameters for assessing frontal and subcortical brain regions (Ernst an…”
MethodInfluentialISMRM workshop on fat–water separation: Insights, applications and progress in MRI
Hu, H. H., Börnert, P., Hernando, D., Kellman, P., Ma, J., Reeder, S., & Sirlin, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24369 · Cited by 189
“While PRESS benefits from increased signal-to-noise ratio, STEAM is capable of shorter minimum TEs (132).”
BackgroundInfluentialHighly resolved in vivo 1H NMR spectroscopy of the mouse brain at 9.4 T
Tkáč, I., Henry, P., Andersen, P., Keene, C. D., Low, W. C., & Gruetter, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20184 · Cited by 187
“Sensitivity can be further increased by using spin-echo based single-shot localization methods such as PRESS (29) or LASER (30), but this can typically be achieved only at the expense of increased echo time, which may result in more complicated spectral pattern and additional signal loss due to J-evolution and T2 rela…”
MethodFast image reconstruction with L2‐regularization
Bilgic, B., Chatnuntawech, I., Fan, A. P., Setsompop, K., Cauley, S. F., Wald, L. L., & Adalsteinsson, E. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24365 · Cited by 185
“Chemical shift selective suppression (CHESS (23)) pulse was applied for water suppression, and PRESS-box (point resolved spectroscopy (24)) excited the entire field-of-view; however, no lipid suppression was applied during acquisition.”
MethodMethodology of1H NMR spectroscopy of the human brain at very high magnetic fields
Tkáć, I., & Gruetter, R. (2005) · Applied Magnetic Resonance · doi:10.1007/bf03166960 · Cited by 184
Schuff, N., Ezekiel, F., Gamst, A. C., Amend, D. L., Capizzano, A. A., Maudsley, A. A., & Weiner, M. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1119 · Cited by 184
“2 xn, yk9 2 yn!pP~zl9 2 zn!p smax s~xn, yn, zn! [1]”
MethodBig GABA: Edited MR spectroscopy at 24 research sites
Mikkelsen, M., Barker, P. B., Bhattacharyya, P. K., Brix, M. K., Buur, P. F., Cecil, K. M., Chan, K. L., Chen, D. Y.-T., Craven, A. R., Cuypers, K., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.021 · Cited by 183
“, 1998), a J-difference spectral editing technique that is typically implemented within a point resolved spectroscopy (PRESS) (Bottomley, 1987) acquisition.”
MethodJenkins, B. G., Klivenyi, P., Kustermann, E., Andreassen, O. A., Ferrante, R. J., Rosen, B. R., & Beal, M. F. (2000) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2000.0742108.x · Cited by 175
“Localized proton spectroscopy was done using a PRESS sequence (Bottomley, 1987) at three different TE values (68, 136, and 272 ms) for each animal with a TR of 2 s.”
MethodTHE PROSTATE: MR IMAGING AND SPECTROSCOPY
Kurhanewicz, J., Vigneron, D. B., Males, R. G., Swanson, M. G., Yu, K. K., & Hricak, H. (2000) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(05)70152-4 · Cited by 175
Method for high‐resolution imaging of creatine in vivo using chemical exchange saturation transfer
Kogan, F., Haris, M., Singh, A., Cai, K., Debrosse, C., Nanga, R. P. R., Hariharan, H., & Reddy, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24641 · Cited by 174
“(1)H MRS spectra were obtained from a region in the lateral gastrocnemius muscle using a standard point resolved spectroscopy (37) localization technique with the following parameters: voxel size1⁄410 20 10 mm(3), spectral width1⁄43 kHz, number of points1⁄42048, average1⁄416, TE1⁄420 ms, and TR1⁄43 s.”
MethodSilveri, M. M., Sneider, J. T., Crowley, D. J., Covell, M. J., Acharya, D., Rosso, I. M., & Jensen, J. E. (2013) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.01.033 · Cited by 174
Jessen, F., Block, W., Träber, F., Keller, E., Flacke, S., Papassotiropoulos, A., Lamerichs, R., Heun, R., & Schild, H. H. (2000) · Neurology · doi:10.1212/wnl.55.5.684 · Cited by 174
Grodd, W., Krägeloh-Mann, I., Klose, U., & Sauter, R. (1991) · Radiology · doi:10.1148/radiology.181.1.1887030 · Cited by 173
Detection of oncogenic IDH1 mutations using magnetic resonance spectroscopy of 2-hydroxyglutarate
Andronesi, O. C., Rapalino, O., Gerstner, E., Chi, A., Batchelor, T. T., Cahill, D. P., Sorensen, A. G., & Rosen, B. R. (2013) · Journal of Clinical Investigation · doi:10.1172/jci67229 · Cited by 171
“( B ) Spectral editing with PRESS sequence of TE 97 ms (TE1: 32 ms, TE2: 65 ms) in a patient with mutant IDH1 oligodendroglioma.”
InfluentialThe Estimation of Local Brain Temperature by in Vivo1H Magnetic Resonance Spectroscopy
Cady, E. B., D'Souza, P. C., Penrice, J., & Lorek, A. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330620 · Cited by 169
Whole body fat: Content and distribution
Thomas, E. L., Fitzpatrick, J. A., Malik, S. J., Taylor-Robinson, S. D., & Bell, J. D. (2013) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.04.001 · Cited by 168
“In most published studies of ectopic fat, the MRS localisation technique of choice appears to be the PRESS sequence (point-resolved-spectroscopy) developed in the early 1980s [142].”
BackgroundElevated subcortical choline metabolites in cognitively and clinically asymptomatic HIV patients
Meyerhoff, D. J., Bloomer, C., Cardenas, V., Norman, D., Weiner, M. W., & Fein, G. (1999) · Neurology · doi:10.1212/wnl.52.5.995 · Cited by 166
Glutamate and GABA Homeostasis and Neurometabolism in Major Depressive Disorder
Sarawagi, A., Soni, N. D., & Patel, A. B. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.637863 · Cited by 165
“Point-Resolved Spectroscopy (PRESS) This is referred as a double spin-echo localization method, wherein a 90 radiofrequency pulse is followed by two 180 pulses together with magnetic field gradients along three orthogonal axes (101).”
MethodRae, C. D., & Williams, S. R. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2016.12.022 · Cited by 164
Goh, S., Dong, Z., Zhang, Y., DiMauro, S., & Peterson, B. S. (2014) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2014.179 · Cited by 164
1H-MRS metabolic patterns for distinguishing between meningiomas and other brain tumors
Cho, Y.-D., Choi, G.-H., Lee, S.-P., & Kim, J.-K. (2003) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(03)00097-3 · Cited by 162
“Localized single voxel proton MR spectroscopy was performed using stimulated echo acquisition mode [10] (STEAM, TE/TR, 34 ms/2000 ms) and point resolved spectroscopy [11] (PRESS, TE/TR, 272 or 288 ms/2000 ms) with three chemical shift selective pulses (CHESS) and subsequent spoiling gradient for water suppression.”
MethodBajaj, M., Suraamornkul, S., Hardies, L. J., Pratipanawatr, T., & DeFronzo, R. A. (2004) · International Journal of Obesity · doi:10.1038/sj.ijo.0802625 · Cited by 159
Haroon, E., Woolwine, B. J., Chen, X., Pace, T. W., Parekh, S., Spivey, J. R., Hu, X. P., & Miller, A. H. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2014.25 · Cited by 154
Gonzalez, J. T., Fuchs, C. J., Smith, F. E., Thelwall, P. E., Taylor, R., Stevenson, E. J., Trenell, M. I., Cermak, N. M., & van Loon, L. J. C. (2015) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00376.2015 · Cited by 95
“0 using 256 the least square fitting AMARES algorithm (4, 31).”
MethodZhu, X., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1267 · Cited by 92
“Briefly, the sequence consisted of single-voxel spatial localization (2 3 2 3 3 5 12 cm(3)) using the PRESS technique (26) combined with outer-volume and water suppression techniques.”
MethodArnold, P. D., MacMaster, F. P., Richter, M. A., Hanna, G. L., Sicard, T., Burroughs, E., Mirza, Y., Easter, P. C., Rose, M., Kennedy, J. L., et al. (2009) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2009.02.005 · Cited by 91
“1) with a shortecho single voxel double spin-echo point resolved spectroscopy (PRESS) pulse sequence (Bottomley, 1987).”
MethodRico‐Sanz, J., Hajnal, J. V., Thomas, E. L., Mierisová, Ŝ., Ala‐Korpela, M., & Bell, J. D. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.615bk.x · Cited by 88
“A point resolved spectroscopy sequence (PRESS) (Bottomley, 1987) with TEÏTR = 135Ï1500 ms was used with an 8 cmÅ voxel positioned within each of the muscles examined (Fig.”
MethodPerformance of a 200‐MHz cryogenic RF probe designed for MRI and MRS of the murine brain
Ratering, D., Baltes, C., Nordmeyer‐Massner, J., Marek, D., & Rudin, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21629 · Cited by 91
MOORE, G. J., MACMASTER, F. P., STEWART, C., & ROSENBERG, D. R. (1998) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-199806000-00017 · Cited by 85
Ensenauer, R., Thiel, T., Schwab, K. O., Tacke, U., Stöckler-Ipsiroglu, S., Schulze, A., Hennig, J., & Lehnert, W. (2004) · Molecular Genetics and Metabolism · doi:10.1016/j.ymgme.2004.04.005 · Cited by 71
Detcheverry, F., Senthil, S., Narayanan, S., & Badhwar, A. (2023) · NeuroImage: Clinical · doi:10.1016/j.nicl.2023.103503 · Cited by 64
“Biochemical analyses of autopsy brain tissue: A series of physical and chemical changes take place in the body following death (reviewed by Brooks, 2016).”
BackgroundKaur, G., Sharma, A., Xu, W., Gerum, S., Alldred, M. J., Subbanna, S., Basavarajappa, B. S., Pawlik, M., Ohno, M., Ginsberg, S. D., et al. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.5338-13.2014 · Cited by 58
MRI and 1H MRS findings in Smith-lemli-opitz syndrome
Caruso, P. A., Poussaint, T. Y., Tzika, A. A., Zurakowski, D., Astrakas, L. G., Elias, E. R., Bay, C., & Irons, M. B. (2004) · Neuroradiology · doi:10.1007/s00234-003-1110-1 · Cited by 51
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Altered Reward Circuitry in the Norepinephrine Transporter Knockout Mouse
Gallagher, J. J., Zhang, X., Hall, F. S., Uhl, G. R., Bearer, E. L., & Jacobs, R. E. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057597 · Cited by 25
“For each mouse brain (n = 11 NET KOs and n = 12 wildtype) the spectrum of the relative amount of metabolites inside the experimental PRESS volume was quantified using the QUEST (quantitation based on quantum estimation) module [114] available inside the Java Magnetic Resonance User Interface (JMRUI) package [115].”
MethodInfluentialKrauspe, B. M., Dreher, W., Beyer, C., Baumgartner, W., Denecke, B., Janssen, K., Langhans, C.-D., Clarner, T., & Kipp, M. (2015) · Journal of Molecular Neuroscience · doi:10.1007/s12031-014-0412-6 · Cited by 22
“For single voxel MR spectroscopy, a double spin echo PRESS sequence (Bottomley, 1987) was used (TR 2.”
MethodDextro-amphetamine increases phosphoinositol cycle activity in volunteers: an MRS study
Silverstone, P. H., O'Donnell, T., Ulrich, M., Asghar, S., & Hanstock, C. C. (2002) · Human Psychopharmacology: Clinical and Experimental · doi:10.1002/hup.434 · Cited by 18
“1H MR spectra were acquired using the PRESS localization method (Bottomley, 1987; Gordon and Ordidge, 1984), with TE¼ 32 ms, TR¼ 3 s, and with 128 averages.”
Metadata
- Authors
- BOTTOMLEY, P. A.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 1987-11
- Volume
- 508
- Issue
- 1
- Pages
- 333-348
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2058027749
- Cited by
- 1,378
- References
- 9
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.