Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces
Open accessThe DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
Abstract
Researchers report advances in materials and designs for skin-integrated devices capable of measuring acoustic signatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As demonstrated in Figure 9D, a high-density epidermal sensing array consisting of 17 mesh electrodes is integrated on the residual limbs to record EMG signals for prosthetic applications.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [388]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Physical strapping or taping is also required to reduce the acoustic mismatch caused by the air gap between the rigid accelerometer and the skin.7”
From A Chest‐Laminated Ultrathin and Stretchable E‐Tattoo for the Measurement of Electrocardiogram, Seismocardiogram, and Cardiac Time Intervals (2019) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While the soft circuit is already a big improvement over a rigid PCB, the accelerometer mounted on the soft circuit is still a 2‐mm‐thick rigid chip, and the fabrication relies on expensive photolithography and micro‐transfer processes.”
From A Chest‐Laminated Ultrathin and Stretchable E‐Tattoo for the Measurement of Electrocardiogram, Seismocardiogram, and Cardiac Time Intervals (2019) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although SCG can be measured by mounting commercial accelerometers on the human chest,6 the thickness and rigidity of conventional accelerometers make them uncomfortable to wear and susceptible to the global inertial motion of the body.7”
From A Chest‐Laminated Ultrathin and Stretchable E‐Tattoo for the Measurement of Electrocardiogram, Seismocardiogram, and Cardiac Time Intervals (2019) · cites this paper as [7]
Experimental — accuracy not yet measuredIn the citing paper
“Furthermore, a soft, conformal class of device records physiological mechano-acoustic signals from the skin, capable of heart murmur detection in a series of cardiac patients for advanced clinical diagnostics [Fig.1(b)].27”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hinton, G., Deng, L., Yu, D., Dahl, G., Mohamed, A.-R., Jaitly, N., Senior, A., Vanhoucke, V., Nguyen, P., Sainath, T., et al. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2205597 · Cited by 10,260
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationSuppression of acoustic noise in speech using spectral subtraction
Boll, S. (1979) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1979.1163209 · Cited by 4,634
Principles of Voice Production
Titze, I. R., & Martin, D. W. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.424266 · Cited by 1,643 · cited 1×
“Vibration frequencies of vocal folds in humans range from 90 to 2000 Hz (39), with an average fundamental frequency of ~116 Hz (male; mean age, 19.”
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229 · cited 1×
“Examples include precision measurement of temperature and thermal transport characteristics ( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic…”
Self-citationSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Self-citationFractal design concepts for stretchable electronics
Fan, J. A., Yeo, W.-H., Su, Y., Hattori, Y., Lee, W., Jung, S.-Y., Zhang, Y., Liu, Z., Cheng, H., Falgout, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms4266 · Cited by 1,088
Self-citationDagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987 · cited 1×
“…15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic dimensional changes, such as those associated with swelling/deswelling or pulsatile blood flow ( 20 , 21 ).”
Self-citationXu, S., Yan, Z., Jang, K.-I., Huang, W., Fu, H., Kim, J., Wei, Z., Flavin, M., McCracken, J., Wang, R., et al. (2015) · Science · doi:10.1126/science.1260960 · Cited by 931
Self-citationThe physics of small-amplitude oscillation of the vocal folds
Titze, I. R. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.395910 · Cited by 862
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828 · cited 1×
“…and thermal transport characteristics ( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic dimensional changes, such as those associated with…”
Self-citationMaterials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics
Jeong, J., Yeo, W., Akhtar, A., Norton, J. J. S., Kwack, Y., Li, S., Jung, S., Su, Y., Lee, W., Xia, J., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301921 · Cited by 827
Self-citationBallistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · cited 1×
“…from the heart) ( 28 ), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) ( 29 – 34 ), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) ( 28 , 30 , 35 , 36 ), and sounds associated with respiration ( 22 , 23 ).”
Respiratory Sounds: Advances Beyond the Stethoscope
PASTERKAMP, H., KRAMAN, S. S., & WODICKA, G. R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.3.9701115 · Cited by 634 · cited 3×
“Mechano-acoustic signals are known to contain essential information for clinical diagnosis and healthcare applications ( 22 , 23 ).”
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513 · cited 1×
“Examples include precision measurement of temperature and thermal transport characteristics (14, 15), recording of electrophysiological processes and variations in electrical impedance (16–18), characterization of skin stiffness (5, 19), and monitoring of quasi-static or dynamic dimensional changes, such as those asso…”
Self-citationWireless Optofluidic Systems for Programmable In Vivo Pharmacology and Optogenetics
Jeong, J.-W., McCall, J. G., Shin, G., Zhang, Y., Al-Hasani, R., Kim, M., Li, S., Sim, J. Y., Jang, K.-I., Shi, Y., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.058 · Cited by 498
Self-citationTime domain wave equations for lossy media obeying a frequency power law
Szabo, T. L. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410434 · Cited by 420
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Self-citationJang, K.-I., Han, S. Y., Xu, S., Mathewson, K. E., Zhang, Y., Jeong, J.-W., Kim, G.-T., Webb, R. C., Lee, J. W., Dawidczyk, T. J., et al. (2014) · Nature Communications · doi:10.1038/ncomms5779 · Cited by 383
Self-citationHuman hearing enhanced by noise11Published on the World Wide Web on 23 May 2000.
Zeng, F.-G., Fu, Q.-J., & Morse, R. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02475-6 · Cited by 309
Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304 · cited 1×
“A video of a user playing a Pac-Man game appears in video S3; these same speech recognition strategies can be applied to almost any type of human-machine interfaces, such as drone and prosthesis control ( 9 , 11 , 12 ).”
Self-citationCapacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Self-citationHattori, Y., Falgout, L., Lee, W., Jung, S., Poon, E., Lee, J. W., Na, I., Geisler, A., Sadhwani, D., Zhang, Y., et al. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400073 · Cited by 276
Self-citationA model for longitudinal and shear wave propagation in viscoelastic media
Szabo, T. L., & Wu, J. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.428630 · Cited by 274
Epidermal Electronics with Advanced Capabilities in Near-Field Communication
Kim, J., Banks, A., Cheng, H., Xie, Z., Xu, S., Jang, K.-I., Lee, J. W., Liu, Z., Gutruf, P., Huang, X., et al. (2015) · Small · doi:10.1002/smll.201402495 · Cited by 274
Self-citationWebb, R. C., Ma, Y., Krishnan, S., Li, Y., Yoon, S., Guo, X., Feng, X., Shi, Y., Seidel, M., Cho, N. H., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500701 · Cited by 244 · cited 1×
“…15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic dimensional changes, such as those associated with swelling/deswelling or pulsatile blood flow ( 20 , 21 ).”
Self-citationMechanics of Epidermal Electronics
Wang, S., Li, M., Wu, J., Kim, D.-H., Lu, N., Su, Y., Kang, Z., Huang, Y., & Rogers, J. A. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4005963 · Cited by 214 · cited 1×
“…( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic dimensional changes, such as those associated with swelling/deswelling or pulsatile blood flow (…”
Self-citationModified Szabo’s wave equation models for lossy media obeying frequency power law
Chen, W., & Holm, S. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1621392 · Cited by 181
Castiglioni, P., Faini, A., Parati, G., & Di Rienzo, M. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353199 · Cited by 154 · cited 2×
“…of phonocardiography (PCG; sounds from the heart) ( 28 ), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) ( 29 – 34 ), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) ( 28 , 30 , 35 , 36 ), and sounds…”
Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Wave-induced fluid flow in random porous media: Attenuation and dispersion of elastic waves
Müller, T. M., & Gurevich, B. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1894792 · Cited by 144
Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring
Huang, X., Yeo, W.-H., Liu, Y., & Rogers, J. A. (2012) · Biointerphases · doi:10.1007/s13758-012-0052-8 · Cited by 144
Self-citationComputerized heart sounds analysis
Debbal, S. M. E. A., & Bereksi-Reguig, F. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.09.006 · Cited by 143
Soft Core/Shell Packages for Stretchable Electronics
Lee, C. H., Ma, Y., Jang, K., Banks, A., Pan, T., Feng, X., Kim, J. S., Kang, D., Raj, M. S., McGrane, B. L., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201501086 · Cited by 131 · cited 1×
“…plane between layers of polyimide (PI) encapsulation (1.2 m m)] as circuit interconnects between commercial, small-scale chip components, all encapsulated above and below by an ultralow-modulus elastomeric core [Silbione RT Gel 4717 A/B, Bluestar Silicone; Young ’ s modulus E = 5 kPa ( 2 , 37 )].”
InfluentialSelf-citationEpidermal Impedance Sensing Sheets for Precision Hydration Assessment and Spatial Mapping
Huang, X., Cheng, H., Chen, K., Zhang, Y., Zhang, Y., Liu, Y., Zhu, C., Ouyang, S.-C., Kong, G.-W., Yu, C., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264879 · Cited by 113
Self-citationIntroduction to the Physics of Ultrasound
Laugier, P., & Haïat, G. (2010) · Springer eBooks · doi:10.1007/978-94-007-0017-8_2 · Cited by 109
Seismocardiography: a technique for recording precordial acceleration
Zanetti, J. M., & Salerno, D. M. (2002) · [1991] Computer-Based Medical Systems@m_Proceedings of the Fourth Annual IEEE Symposium · doi:10.1109/cbms.1991.128936 · Cited by 103 · cited 1×
“…phonocardiography (PCG; sounds from the heart) ( 28 ), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) ( 29 – 34 ), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) ( 28 , 30 , 35 , 36 ), and sounds associated…”
Chuo, Y., Marzencki, M., Hung, B., Jaggernauth, C., Tavakolian, K., Lin, P., & Kaminska, B. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2052616 · Cited by 102
He, D. D., Winokur, E. S., & Sodini, C. G. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091171 · Cited by 99 · cited 1×
“Research demonstrations include recording of phonocardiography (PCG; sounds from the heart) (28), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) (29–34), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) (28, 30, 35, 36), and sounds a…”
Webb, R. C., Pielak, R. M., Bastien, P., Ayers, J., Niittynen, J., Kurniawan, J., Manco, M., Lin, A., Cho, N. H., Malyrchuk, V., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118131 · Cited by 98 · cited 1×
“Examples include precision measurement of temperature and thermal transport characteristics ( 14 , 15 ), recording of electrophysiological processes and variations in electrical impedance ( 16 – 18 ), characterization of skin stiffness ( 5 , 19 ), and monitoring of quasi-static or dynamic…”
Self-citationCombining standard and throat microphones for robust speech recognition
Graciarena, M., Franco, H., Sönmez, K., & Bratt, H. (2003) · IEEE Signal Processing Letters · doi:10.1109/lsp.2003.808549 · Cited by 96
Physiological Acoustic Sensing Based on Accelerometers: A Survey for Mobile Healthcare
Hu, Y., Kim, E. G., Cao, G., Liu, S., & Xu, Y. P. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1111-8 · Cited by 93 · cited 3×
“Mechano-acoustic signals are known to contain essential information for clinical diagnosis and healthcare applications ( 22 , 23 ).”
Speech interfaces based upon surface electromyography
Jorgensen, C. C., & Dusan, S. (2009) · Speech Communication · doi:10.1016/j.specom.2009.11.003 · Cited by 76
Web Browser Control Using EMG Based Sub Vocal Speech Recognition
Jorgensen, C., & Binsted, K. (2005) · Proceedings of the 38th Annual Hawaii International Conference on System Sciences · doi:10.1109/hicss.2005.683 · Cited by 69
Seismocardiography: waveform identification and noise analysis
Zanetti, J. M., Poliac, M. O., & Crow, R. S. (2002) · [1991] Proceedings Computers in Cardiology · doi:10.1109/cic.1991.169042 · Cited by 62
A wearable system for the seismocardiogram assessment in daily life conditions
Di Rienzo, M., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Merati, G., Parati, G., & Castiglioni, P. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091058 · Cited by 61
Erzin, E. (2009) · IEEE Transactions on Audio Speech and Language Processing · doi:10.1109/tasl.2009.2016733 · Cited by 57
Acoustic Spectral Analysis for Determining Pump Thrombosis in Rotary Blood Pumps
Kaufmann, F., Hoermandinger, C., Stepanenko, A., Kretzschmar, A., Soltani, S. M., Krabatsch, T., Potapov, E. V., & Hetzer, R. (2014) · ASAIO Journal · doi:10.1097/mat.0000000000000097 · Cited by 55
Elastic and viscous properties of resting frog skeletal muscle
Moss, R. L., & Halpern, W. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85651-8 · Cited by 50 · cited 2×
“The tissue was modeled as a visco-elastic solid, with a Young ’ s modulus of 0.18 MPa ( 65 ) and a Prony series function with constants g i = k i = 0.91001 s and t i = 0.9899 s.”
InfluentialSmall-vocabulary speech recognition using surface electromyography
Betts, B. J., Binsted, K. A., & Jorgensen, C. C. (2006) · Interacting with Computers · doi:10.1016/j.intcom.2006.08.012 · Cited by 48 · cited 1×
“This feature could allow the epidermal acoustic sensor to be used for communication in loud environments by first responders (63), ground controllers, or security agents.”
The recording of heart vibrations: a problem of vibration measurement on soft tissue
Vermarien, H., & van Vollenhoven, E. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446821 · Cited by 48 · cited 2×
“1H), as expected from the acoustic attenuation ( 41 , 42 ) by absorption and scattering in visco-elastic materials and at the materials interfaces ( 43 – 45 ).”
Array-based Electromyographic Silent Speech Interface
Wand, M., Schulte, C., Janke, M., & Schultz, T. (2013) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0004252400890096 · Cited by 47
Acoustic Analysis of a Mechanical Circulatory Support
Hűbbert, L., Sundbom, P., Loebe, M. M., Peterzén, B., Granfeldt, H., & Ahn, H. (2013) · Artificial Organs · doi:10.1111/aor.12244 · Cited by 40
Disordered speech recognition using acoustic and sEMG signals
Deng, Y., Patel, R., Heaton, J. T., Colby, G., Gilmore, L., Cabrera, J. B. D., Roy, S. H., Luca, C. J. D., & Meltzner, G. S. (2009) · Interspeech (USB) · doi:10.21437/interspeech.2009-227 · Cited by 35 · cited 2×
“An earlier study ( 52 ) showed that fusion of acoustic data with EMG signals measured using separate devices improved word recognition accuracy in a small group of patients with dysarthria.”
Hasin, T., Deo, S. V., Maleszewski, J. J., Topilsky, Y., Edwards, B. S., Pereira, N. L., Stulak, J. M., Joyce, L. D., Daly, R. C., Kushwaha, S. S., et al. (2013) · ASAIO Journal · doi:10.1097/mat.0000000000000012 · Cited by 35
Acceleration Ballistocardiography: Design, Construction, and Application of a New Instrument
ELLIOTT, R. V., PACKARD, R. G., & KYRAZIS, D. T. (1954) · Circulation · doi:10.1161/01.cir.9.2.281 · Cited by 32
Controlling a prosthetic arm with a throat microphone
Mainardi, E., & Davalli, A. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352968 · Cited by 30
Yost, G. L., Royston, T. J., Bhat, G., & Tatooles, A. J. (2015) · ASAIO Journal · doi:10.1097/mat.0000000000000307 · Cited by 23 · cited 1×
“Previous work in the context of the first failure mode shows that the formation of blood clots on the rotor leads to changes in the sounds of the pump ( 47 – 51 ).”
Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure
Kawahito, K. (2013) · Journal of Artificial Organs · doi:10.1007/s10047-013-0709-1 · Cited by 11
SNR-Adaptive Stream Weighting for Audio-MES ASR
Lee, K.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921094 · Cited by 11 · cited 1×
“A specific suggestion is that throat EMG can enhance traditional speech recognition techniques (57, 61), although simultaneous recording of EMG and acoustics in a single device has not been demonstrated.”
Fusion of standard and alternative acoustic sensors for robust automatic speech recognition
Heracleous, P., Even, J., Ishi, C. T., Miyashita, T., & Hagita, N. (2012) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2012.6289002 · Cited by 7
Seismocardiogram and Ballistocardiogram Sensing
Postolache, O., Girão, P., & Postolache, G. (2013) · Advanced Instrument Engineering · doi:10.4018/978-1-4666-4165-5.ch017 · Cited by 5
Research works printed but not linked: 4
- F.-G. Zeng, Q.-J. Fu, R. Morse, Human hearing enhanced by noise. Brain Res. 869, 251–255 (2000).
- F. Dunn W. M. Hartmann D. M. Campbell N. H. Fletcher T. D. Rossing Eds. Springer Handbook of Acoustics (Springer 2015).
- S. A. Gelfand Essentials of Audiology (Thieme 2007).
- S. Dupont C. Ris D. Bachelart Combined use of close-talk and throat microphones for improved speech recognition under non-stationary background noise in COST278 and ISCA Tutorial and Research Workshop (ITRW) on Robustness Issues in Conversational Interaction Norwich U.K. 30 to 31 August 2004 (2004); www.isca-speech.org/archive_open/robust2004.
Cited by
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Rich, S. I., Wood, R. J., & Majidi, C. (2018) · Nature Electronics · doi:10.1038/s41928-018-0024-1 · Cited by 1,022
Metadata
- Authors
- Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., Zhang, D., Kilian, K. A., Jung, S. H., Bretl, T., Xiao, J., Slepian, M. J., Huang, Y., Jeong, J.-W., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- University of Colorado Boulder (US)
- University of Arizona (US)
- Eulji University (KR)
- Northwestern University (US)
- Corresponding author
- Huang, Yonggang
- Jeong, Jae-Woong
- Rogers, John A.
- ORCID
- Venue
- Science Advances
- Published
- 2016-11-04
- Volume
- 2
- Issue
- 11
- Pages
- e1601185-e1601185
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC5262452
- OpenAlex
- W2550979959
- Cited by
- 397
- References
- 63
- Citations by year
- 2026: 19 · 2025: 33 · 2024: 39 · 2023: 48 · 2022: 59 · 2021: 54 · 2020: 47 · 2019: 36 · 2018: 40 · 2017: 22
- FWCI
- 15.75
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Science Advances (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- UA Campus Repository (The University of Arizona) (acceptedVersion, cc-by-nc)
- UNSWorks (UNSW Sydney) (submittedVersion, cc-by-nc-nd)
- Funders
- Semiconductor Research Corporation
- Defense Advanced Research Projects Agency
- University of Illinois at Urbana-Champaign
- University of Colorado Boulder
- National Heart, Lung, and Blood Institute (T32HL007955)
- Division of Materials Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Keywords
- seismocardiography, heart murmur detection, cardiovascular diagnostics, wearable sensors, electrophysiological recording, ventricular assist devices, speech recognition, human-machine interaction, low modulus materials
- MeSH terms
- Animals, Diagnostic Techniques, Cardiovascular, Electronics, Medical, Epidermis, Heart Murmurs, Heart-Assist Devices, Humans, Thrombosis, User-Computer Interface, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.