Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Possessing the ability to noninvasively elicit brain circuit activity yields immense experimental and therapeutic power. Most currently employed neurostimulation methods rely on the somewhat invasive use of stimulating electrodes or photon-emitting devices. Due to its ability to noninvasively propagate through bone and other tissues in a focused manner, the implementation of ultrasound (US) represents a compelling alternative approach to current neuromodulation strategies. Here, we investigated the influence of low-intensity, low-frequency ultrasound (LILFU) on neuronal activity. By transmitting US waveforms through hippocampal slice cultures and ex vivo mouse brains, we determined LILFU is capable of remotely and noninvasively exciting neurons and network activity. Our results illustrate that LILFU can stimulate electrical activity in neurons by activating voltage-gated sodium channels, as well as voltage-gated calcium channels. The LILFU-induced changes in neuronal activity were sufficient to trigger SNARE-mediated exocytosis and synaptic transmission in hippocampal circuits. Because LILFU can stimulate electrical activity and calcium signaling in neurons as well as central synaptic transmission we conclude US provides a powerful tool for remotely modulating brain circuit activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simple method for organotypic cultures of nervous tissue
Stoppini, L., Buchs, P.-A., & Muller, D. (1991) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(91)90128-m · Cited by 3,089
Imaging Neuronal Subsets in Transgenic Mice Expressing Multiple Spectral Variants of GFP
Feng, G., Mellor, R. H., Bernstein, M., Keller-Peck, C., Nguyen, Q. T., Wallace, M., Nerbonne, J. M., Lichtman, J. W., & Sanes, J. R. (2000) · Neuron · doi:10.1016/s0896-6273(00)00084-2 · Cited by 3,042
Visualizing secretion and synaptic transmission with pH-sensitive green fluorescent proteins
Miesenböck, G., De Angelis, D. A., & Rothman, J. E. (1998) · Nature · doi:10.1038/28190 · Cited by 2,563
Multimodal fast optical interrogation of neural circuitry
Zhang, F., Wang, L.-P., Brauner, M., Liewald, J. F., Kay, K., Watzke, N., Wood, P. G., Bamberg, E., Nagel, G., Gottschalk, A., et al. (2007) · Nature · doi:10.1038/nature05744 · Cited by 1,738
Brunet, A., Datta, S. R., & Greenberg, M. E. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00211-7 · Cited by 1,188
Definition of the Readily Releasable Pool of Vesicles at Hippocampal Synapses
Rosenmund, C., & Stevens, C. F. (1996) · Neuron · doi:10.1016/s0896-6273(00)80146-4 · Cited by 1,088
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Vascular endothelial growth factor: Direct neuroprotective effect in in vitro ischemia
Jin, K. L., Mao, X. O., & Greenberg, D. A. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.18.10242 · Cited by 684
Cited by
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Self-citationTranscranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Self-citationThe blood-brain barrier: Physiology and strategies for drug delivery
Pandit, R., Chen, L., & Götz, J. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.11.009 · Cited by 651
Focused ultrasound modulates region-specific brain activity
Yoo, S.-S., Bystritsky, A., Lee, J.-H., Zhang, Y., Fischer, K., Min, B.-K., McDannold, N. J., Pascual-Leone, A., & Jolesz, F. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.058 · Cited by 613
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Yoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G. (2022) · Nature Communications · doi:10.1038/s41467-022-28040-1 · Cited by 492
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
Self-citationTranscranial focused ultrasound stimulation of human primary visual cortex
Lee, W., Kim, H.-C., Jung, Y., Chung, Y. A., Song, I.-U., Lee, J.-H., & Yoo, S.-S. (2016) · Scientific Reports · doi:10.1038/srep34026 · Cited by 415
A review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Folloni, D., Verhagen, L., Mars, R. B., Fouragnan, E., Constans, C., Aubry, J.-F., Rushworth, M. F. S., & Sallet, J. (2019) · Neuron · doi:10.1016/j.neuron.2019.01.019 · Cited by 401
Low-Intensity Focused Ultrasound Modulates Monkey Visuomotor Behavior
Deffieux, T., Younan, Y., Wattiez, N., Tanter, M., Pouget, P., & Aubry, J.-F. (2013) · Current Biology · doi:10.1016/j.cub.2013.10.029 · Cited by 392
Sonogenetics is a non-invasive approach to activating neurons in Caenorhabditis elegans
Ibsen, S., Tong, A., Schutt, C., Esener, S., & Chalasani, S. H. (2015) · Nature Communications · doi:10.1038/ncomms9264 · Cited by 375
Ultrasound modulates ion channel currents
Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J. (2016) · Scientific Reports · doi:10.1038/srep24170 · Cited by 353
A Review of Low-Intensity Pulsed Ultrasound for Therapeutic Applications
Jiang, X., Savchenko, O., Li, Y., Qi, S., Yang, T., Zhang, W., & Chen, J. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889669 · Cited by 353
Non-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications
Fomenko, A., Neudorfer, C., Dallapiazza, R. F., Kalia, S. K., & Lozano, A. M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2018.08.013 · Cited by 322
Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway
Guo, H., Hamilton, M., Offutt, S. J., Gloeckner, C. D., Li, T., Kim, Y., Legon, W., Alford, J. K., & Lim, H. H. (2018) · Neuron · doi:10.1016/j.neuron.2018.04.036 · Cited by 291
Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity
Min, B.-K., Bystritsky, A., Jung, K.-I., Fischer, K., Zhang, Y., Maeng, L.-S., In Park, S., Chung, Y.-A., Jolesz, F. A., & Yoo, S.-S. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-23 · Cited by 274
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Focused ultrasound wave has recently been explored as a noninvasive alternative in neural stimulation (Gavrilov et al., 1996; Tufail et al., 2011; Tyler et al., 2008).”
Plaksin, M., Kimmel, E., & Shoham, S. (2016) · eneuro · doi:10.1523/eneuro.0136-15.2016 · Cited by 268
Qiu, Z., Guo, J., Kala, S., Zhu, J., Xian, Q., Qiu, W., Li, G., Zhu, T., Meng, L., Zhang, R., et al. (2019) · iScience · doi:10.1016/j.isci.2019.10.037 · Cited by 266
Ultrasonic Neuromodulation via Astrocytic TRPA1
Oh, S.-J., Lee, J. M., Kim, H.-B., Lee, J., Han, S., Bae, J. Y., Hong, G.-S., Koh, W., Kwon, J., Hwang, E.-S., et al. (2019) · Current Biology · doi:10.1016/j.cub.2019.08.021 · Cited by 249
“Another recent report suggested that ultrasonic neuromodulation occurs via mechanical stretch of the lipid bilayer in neurons [8].”
BackgroundInfluentialUltrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
“A major challenge in studying the biophysical mechanisms of UNM arises from the fact that conventional in vitro models – involving the growth of neurons or other cells on hard substrates and/or recording of their activation with stiff electrodes (Han et al., 2018; Kim et al., 2017; Oh et al., 2020; Prieto et al., 2013…”
BackgroundTranscranial Ultrasound (TUS) Effects on Mental States: A Pilot Study
Hameroff, S., Trakas, M., Duffield, C., Annabi, E., Gerace, M. B., Boyle, P., Lucas, A., Amos, Q., Buadu, A., & Badal, J. J. (2013) · Brain stimulation · doi:10.1016/j.brs.2012.05.002 · Cited by 248
Ultrasonic modulation of neural circuit activity
Tyler, W. J., Lani, S. W., & Hwang, G. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.04.011 · Cited by 239
Self-citationBrain–Computer Interface Technologies in the Coming Decades
Lance, B. J., Kerick, S. E., Ries, A. J., Oie, K. S., & McDowell, K. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184830 · Cited by 231
“While much of the current neural stimulation research is based on invasive probes [117], there are potentially valuable noninvasive neural stimulation techniques based on direct current, magnetic fields [118], ultrasound [119], or infrared light [120].”
BackgroundNoninvasive sub-organ ultrasound stimulation for targeted neuromodulation
Cotero, V., Fan, Y., Tsaava, T., Kressel, A. M., Hancu, I., Fitzgerald, P., Wallace, K., Kaanumalle, S., Graf, J., Rigby, W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08750-9 · Cited by 216
Sanguinetti, J. L., Hameroff, S., Smith, E. E., Sato, T., Daft, C. M. W., Tyler, W. J., & Allen, J. J. B. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00052 · Cited by 214
Self-citationYounan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204
Neuromodulation with transcranial focused ultrasound
Kubanek, J. (2018) · Neurosurgical Focus · doi:10.3171/2017.11.focus17621 · Cited by 195
“30,50,58”
BackgroundResultFocused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Ultrasound activates mechanosensitive TRAAK K + channels through the lipid membrane
Sorum, B., Rietmeijer, R. A., Gopakumar, K., Adesnik, H., & Brohawn, S. G. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006980118 · Cited by 187
“…responses to ultrasound including two-pore domain K + channels (K2Ps), Piezo1, MEC-4, TRPA1, MscL, and voltage-gated Na + and Ca 2+ channels (20 – 24 Tobetter understand mechanisms underlying ultrasonic neuromodulation, we investigated the effects of ultrasound on the mechanosensitive ion…”
A review of low-intensity focused ultrasound for neuromodulation
Baek, H., Pahk, K. J., & Kim, H. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0007-y · Cited by 184
“In 2008, a ground-breaking work was published by Tyler group showing that US is capable of generating action potentials (APs) in central neurons, intracellular influx of Ca2? and Na? ions, and potentiated synaptic transmissions in CNS [23].”
BackgroundActivation of Piezo1 but Not NaV1.2 Channels by Ultrasound at 43 MHz
Prieto, M. L., Firouzi, K., Khuri-Yakub, B. T., & Maduke, M. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.12.020 · Cited by 178
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Lin, W.-T., Chen, R.-C., Lu, W.-W., Liu, S.-H., & Yang, F.-Y. (2015) · Scientific Reports · doi:10.1038/srep09671 · Cited by 172
“Drago, D. et al. Comparative effects of Abeta(1-42)-Al complex from rat and human amyloid on rat endothelial cell cultures.”
Backgrounddi Biase, L., Falato, E., & Di Lazzaro, V. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00549 · Cited by 166
Noninvasive brain stimulation in traumatic brain injury
Demirtas-Tatlidede, A., Vahabzadeh-Hagh, A. M., Bernabeu, M., Tormos, J. M., & Pascual-Leone, A. (2012) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0b013e318217df55 · Cited by 149
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2959439 · Cited by 79
Focused Ultrasound for Essential Tremor: Review of the Evidence and Discussion of Current Hurdles
Rohani, M., & Fasano, A. (2017) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.378 · Cited by 73
The Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
“In addition, experimental evidences have shown that ultrasound can activate mechanosensitive ion channels in neurons [100,106,161,164] and other brain cell types like astrocytes [162], providing additional avenues for ultrasound neuromodulation to interfere with the membrane potential.”
Influential
Metadata
- Authors
- Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2008-10-29
- Volume
- 3
- Issue
- 10
- Pages
- e3511
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2089845241
- Cited by
- 707
- References
- 54
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.