The DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Current and Emerging Technology for Continuous Glucose Monitoring
Open accessAbstract
Diabetes has become a leading cause of death worldwide. Although there is no cure for diabetes, blood glucose monitoring combined with appropriate medication can enhance treatment efficiency, alleviate the symptoms, as well as diminish the complications. For point-of-care purposes, continuous glucose monitoring (CGM) devices are considered to be the best candidates for diabetes therapy. This review focuses on current growth areas of CGM technologies, specifically focusing on subcutaneous implantable electrochemical glucose sensors. The superiority of CGM systems is introduced firstly, and then the strategies for fabrication of minimally-invasive and non-invasive CGM biosensors are discussed, respectively. Finally, we briefly outline the current status and future perspective for CGM systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: “Smart Tattoo” Glucose Biosensors and Effect of Coencapsulated Anti-Inflammatory Agents
Srivastava, R., Jayant, R. D., Chaudhary, A., & McShane, M. J. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500111 · Cited by 41
RetractedWild, S., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1047 · Cited by 15,297
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Surface-Enhanced Raman Spectroscopy
Stiles, P. L., Dieringer, J. A., Shah, N. C., & Van Duyne, R. P. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112814 · Cited by 3,178
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
Biomaterials based on chitin and chitosan in wound dressing applications
Jayakumar, R., Prabaharan, M., Sudheesh Kumar, P. T., Nair, S. V., & Tamura, H. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.01.005 · Cited by 1,924
Novel chitin and chitosan nanofibers in biomedical applications
Jayakumar, R., Prabaharan, M., Nair, S. V., & Tamura, H. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.11.001 · Cited by 1,013
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Shen, P., & Xia, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5001338 · Cited by 596
Kataoka, K., Miyazaki, H., Bunya, M., Okano, T., & Sakurai, Y. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982975d · Cited by 590
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Self-citationBiocompatible Quantum Dots for Biological Applications
Rosenthal, S. J., Chang, J. C., Kovtun, O., McBride, J. R., & Tomlinson, I. D. (2011) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.11.013 · Cited by 532
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
High Ionic Strength Glucose-Sensing Photonic Crystal
Alexeev, V. L., Sharma, A. C., Goponenko, A. V., Das, S., Lednev, I. K., Wilcox, C. S., Finegold, D. N., & Asher, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac030021m · Cited by 405
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Recent developments in blood glucose sensors
Wang, H.-C., & Lee, A.-R. (2015) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2014.12.001 · Cited by 316
Fast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292
High-Q Optical Sensors for Chemical and Biological Analysis
Luchansky, M. S., & Bailey, R. C. (2012) · Analytical Chemistry · doi:10.1021/ac2029024 · Cited by 288
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Salivary characteristics of diabetic children
López, M. E., Colloca, M. E., Páez, R. G., Schallmach, J. N., Koss, M. A., & Chervonagura, A. (2003) · Brazilian Dental Journal · doi:10.1590/s0103-64402003000100005 · Cited by 223
A contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Recent advances in noninvasive glucose monitoring
Chung, J., So, H., Choi, & Wong, T. K. S. (2012) · Medical Devices: Evidence and Research · doi:10.2147/mder.s28134 · Cited by 218
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199
A paper strip based non-invasive glucose biosensor for salivary analysis
Soni, A., & Jha, S. K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.042 · Cited by 173
A Comparison of Ghrelin, Glucose, Alpha-amylase and Protein Levels in Saliva from Diabetics
Aydin, S. (2007) · BMB Reports · doi:10.5483/bmbrep.2007.40.1.029 · Cited by 168
Glucose-Sensitive Holographic Sensors for Monitoring Bacterial Growth
Lee, M.-C., Kabilan, S., Hussain, A., Yang, X., Blyth, J., & Lowe, C. R. (2004) · Analytical Chemistry · doi:10.1021/ac049334n · Cited by 167
Glucose estimation in the salivary secretion of diabetes mellitus patients
Panda, A., Ramesh, & Oza (2012) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s32112 · Cited by 165
Implantable enzyme amperometric biosensors
Kotanen, C. N., Moussy, F. G., Carrara, S., & Guiseppi‐Elie, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.016 · Cited by 162
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
A longitudinal analysis of salivary flow in control subjects and older adults with type 2 diabetes
Chávez, E. M., Borrell, L. N., Taylor, G. W., & Ship, J. A. (2001) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1067/moe.2001.112054 · Cited by 152
Chase, H. P., Beck, R. W., Xing, D., Tamborlane, W. V., Coffey, J., Fox, L. A., Ives, B., Keady, J., Kollman, C., Laffel, L. M., et al. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0021 · Cited by 144
Contact lens interactions with the tear film
Mann, A., & Tighe, B. J. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.07.013 · Cited by 141
Yu, B., Long, N., Moussy, Y., & Moussy, F. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.11.002 · Cited by 141
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129
Linear and Fast Hydrogel Glucose Sensor Materials Enabled by Volume Resetting Agents
Zhang, C., Cano, G. G., & Braun, P. V. (2014) · Advanced Materials · doi:10.1002/adma.201401710 · Cited by 128
Light-Controlled Bioelectrochemical Sensor Based on CdSe/ZnS Quantum Dots
Tanne, J., Schäfer, D., Khalid, W., Parak, W. J., & Lisdat, F. (2011) · Analytical Chemistry · doi:10.1021/ac201329u · Cited by 127
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Towards Smart Tattoos: Implantable Biosensors for Continuous Glucose Monitoring
Heo, Y. J., & Takeuchi, S. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200167 · Cited by 122
Common Causes of Glucose Oxidase Instability in In Vivo Biosensing: A Brief Review
Harris, J. M., Reyes, C. D., & López, G. P. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700428 · Cited by 117
Al-Sagur, H., Komathi, S., Khan, M. A., Gürek, A., & Hassan, A. M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.038 · Cited by 111
A glucose oxidase-coupled DNAzyme sensor for glucose detection in tears and saliva
Liu, C., Sheng, Y., Sun, Y., Feng, J., Wang, S., Zhang, J., Xu, J., & Jiang, D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.070 · Cited by 110
Genina, E. A., Bashkatov, A. N., Sinichkin, Y. P., Yanina, I. Y., & Tuchin, V. V. (2015) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe-2015-1-1-22 · Cited by 109
Yang, X., Pan, X., Blyth, J., & Lowe, C. R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.09.016 · Cited by 103
Amer, S., Yousuf, M., Siddqiui, P. Q., & Alam, J. M. (2001) · PubMed · Cited by 102
Photoelectrochemical sensing of glucose based on quantum dot and enzyme nanocomposites
Zheng, M., Cui, Y., Li, X., Liu, S., & Tang, Z. (2010) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2010.11.036 · Cited by 101
Zhang, W., Du, Y., & Wang, M. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.04.006 · Cited by 97
“Smart” Continuous Glucose Monitoring Sensors: On-Line Signal Processing Issues
Sparacino, G., Facchinetti, A., & Cobelli, C. (2010) · Sensors · doi:10.3390/s100706751 · Cited by 97
New polymerized crystalline colloidal array for glucose sensing
Liu, Y., Zhang, Y., & Guan, Y. (2009) · Chemical Communications · doi:10.1039/b821706h · Cited by 96
Heo, D. N., Song, S.-J., Kim, H., Lee, Y. J., Ko, W., Lee, S. J., Lee, D., Park, S. J., Zhang, L. G., Kang, J. Y., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.05.009 · Cited by 94
Disposable electrochemiluminescent biosensor for lactate determination in saliva
Ballesta Claver, J., Valencia Mirón, M. C., & Capitán-Vallvey, L. F. (2009) · The Analyst · doi:10.1039/b821922b · Cited by 93
Silica-based hybrid materials as biocompatible coatings for glucose sensors
Kros, A., Gerritsen, M., Sprakel, V. S. I., Sommerdijk, N. A. J. M., Jansen, J. A., & Nolte, R. J. M. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00933-9 · Cited by 93
Continuous glucose monitoring in type 1 diabetes
Mauras, N., Fox, L. A., ENGLERT, K. A., & Beck, R. W. (2012) · Endocrine · doi:10.1007/s12020-012-9765-1 · Cited by 91
Measurement of Glucose in Water with First-Overtone Near-Infrared Spectra
Hazen, K. H., Arnold, M. A., & Small, G. W. (1998) · Applied Spectroscopy · doi:10.1366/0003702981943103 · Cited by 86
Surface-enhanced Raman spectroscopy
Popp, J., & Mayerhöfer, T. G. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2864-z · Cited by 84
Kong, K. V., Ho, C. J. H., Gong, T., Lau, W. K. O., & Olivo, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.12.062 · Cited by 81
In vivo glucose monitoring: Towards ‘Sense and Act’ feedback-loop individualized medical systems
Wang, J. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.023 · Cited by 81
Schubert, K., Khalid, W., Yue, Z., Parak, W. J., & Lisdat, F. (2009) · Langmuir · doi:10.1021/la902499e · Cited by 80
Biocompatibility evaluation of sol–gel coatings for subcutaneously implantable glucose sensors
Gerritsen, M., Kros, A., Sprakel, V. S. I., Lutterman, J. A., Nolte, R. J. M., & Jansen, J. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00136-2 · Cited by 79
Wang, H., Zhou, H., Chen, B., Mendes, P. M., Fossey, J., James, T. D., & Long, Y. (2013) · The Analyst · doi:10.1039/c3an01234d · Cited by 78
McQueen, R. B., Ellis, S. L., Campbell, J. D., Nair, K. V., & Sullivan, P. W. (2011) · Cost Effectiveness and Resource Allocation · doi:10.1186/1478-7547-9-13 · Cited by 75
Szypowska, A., Ramotowska, A., Dżygało, K., & Golicki, D. (2011) · European Journal of Endocrinology · doi:10.1530/eje-11-0642 · Cited by 72
Inner ear delivery of dexamethasone using injectable silk-polyethylene glycol (PEG) hydrogel
Yu, D., Sun, C., Zheng, Z., Wang, X., Chen, D., Wu, H., Wang, X., & Shi, F. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.02.048 · Cited by 72
Gamsey, S., Suri, J. T., Wessling, R. A., & Singaram, B. (2006) · Langmuir · doi:10.1021/la0617053 · Cited by 70
Hu, Y., Jiang, X., Zhang, L., Fan, J. R., & Wu, W. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.03.082 · Cited by 65
Enzyme-free glucose biosensor based on low density CNT forest grown directly on a Si/SiO2 substrate
Zhu, Z., Garcia‐Gancedo, L., Chen, C., Zhu, X. R., Xie, H., Flewitt, A. J., & Milne, W. I. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.12.112 · Cited by 64
Self-citationVigersky, R. A. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814565661 · Cited by 64
Current Problems and Potential Techniques in In Vivo Glucose Monitoring
Wickramasinghe, Y., Yang, Y., & Spencer, S. A. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039339.36839.19 · Cited by 63
McGarraugh, G. V., & Bergenstal, R. M. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0047 · Cited by 61
Investigating pipeline and state of the art blood glucose biosensors to formulate next steps
Aggidis, A., Newman, J. D., & Aggidis, G. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.071 · Cited by 60
Micromachined sensor for lactate monitoring in saliva
Schabmueller, C. G. J., Loppow, D., Piechotta, G., Schütze, B., Albers, J., & Hintsche, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.09.015 · Cited by 59
Requirements for Calibration in Noninvasive Glucose Monitoring by Raman Spectroscopy
Lipson, J., Bernhardt, J., Block, U. L., Freeman, W. R., Hofmeister, R. T., Hristakeva, M., Lenosky, T. J., McNamara, R., Petrasek, D., Veltkamp, D. J., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300203 · Cited by 56
Wu, C.-J., Wu, S.-Y., Chen, P., & Lin, Y. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.2959 · Cited by 55
Chou, Y.-N., Chang, Y., & Wen, T. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01756 · Cited by 55
Design of carbon nanotube fiber microelectrode for glucose biosensing
Zhu, Z., Garcia‐Gancedo, L., Flewitt, A. J., Moussy, F. G., Li, Y., & Milne, W. I. (2011) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.2708 · Cited by 53
Self-citationOptimization of a Concanavalin A-Based Glucose Sensor Using Fluorescence Anisotropy
Cummins, B. M., Garza, J. T., & Coté, G. L. (2013) · Analytical Chemistry · doi:10.1021/ac303689j · Cited by 43
Torul, H., Çiftçi, H., Dudak, F. C., Adıgüzel, Y., Külah, H., Boyacı, İ. H., & Tamer, U. (2014) · Analytical Methods · doi:10.1039/c4ay00559g · Cited by 39
Horkay, F., CHO, S. H., Tathireddy, P., Rieth, L. W., Solzbacher, F., & Magda, J. J. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.09.079 · Cited by 39
Diabetes and contact lens wear
O’Donnell, C., & Efron, N. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00738.x · Cited by 37
El-Ads, E. H., Galal, A. M., & Atta, N. F. (2016) · RSC Advances · doi:10.1039/c5ra24107c · Cited by 36
Abraham, A. A., Means, A. K., Clubb, F. J., Fei, R., Locke, A. K., Gacasan, E. G., Coté, G. L., & Grunlan, M. A. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b01061 · Cited by 32
A New Horizon for Glucose Monitoring
Dovč, K., Bratina, N., & Battelino, T. (2015) · Hormone Research in Paediatrics · doi:10.1159/000368924 · Cited by 27
Local release of masitinib alters in vivo implantable continuous glucose sensor performance
Avula, M., Jones, D., Rao, A. N., McClain, D. A., McGill, L. D., Grainger, D. W., & Solzbacher, F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.059 · Cited by 26
Microdialysis-Coupled Enzymatic Microreactor for in Vivo Glucose Monitoring in Rats
Moon, B., de Vries, M. G., CORDEIRO, C. A., Westerink, B. H. C., & Verpoorte, E. M. J. (2013) · Analytical Chemistry · doi:10.1021/ac402414m · Cited by 26
An Injectable PEG-BSA-Coumarin-GOx Hydrogel for Fluorescence Turn-on Glucose Detection
Srinivasan, G., Chen, J., Parisi, J., Brückner, C., Yao, X., & Lei, Y. (2015) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-015-1800-2 · Cited by 21
PEGylated silica-enzyme nanoconjugates: a new frontier in large scale separation of α-amylase
Dehnavi, S. M., Pazuki, G., & Vossoughi, M. (2015) · Scientific Reports · doi:10.1038/srep18221 · Cited by 21
Zhang, X., Gao, C., Lü, S., Duan, H., Jing, N., Dong, D., Shi, C., & Liu, M. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00905c · Cited by 20
Toward CMOS image sensor based glucose monitoring
Devadhasan, J. P., & Kim, S. (2012) · The Analyst · doi:10.1039/c2an35458f · Cited by 13
Alrouq, F. A., Al‐Masri, A. A., AL-Dokhi, L. M., Al-Regaiey, K., Bayoumy, N. M. K., & Zakareia, F. A. (2014) · Journal of Biomedical Science · doi:10.1186/preaccept-2067681611494759 · Cited by 12
CMOS image sensors as an efficient platform for glucose monitoring
Devadhasan, J. P., Kim, S., & Choi, C. S. (2013) · The Analyst · doi:10.1039/c3an00805c · Cited by 9
Buller, M. J., Welles, A. P., Jenkins, O. C., & Hoyt, R. W. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.853101 · Cited by 8
Cited by
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Liu, Y., Wang, H., Zhao, W., Zhang, M., Qin, H., & Xie, Y. (2018) · Sensors · doi:10.3390/s18020645 · Cited by 387
New Advances in General Biomedical Applications of PAMAM Dendrimers
Araújo, R. V. D., Santos, S. D. S., Igne Ferreira, E., & Giarolla, J. (2018) · Molecules · doi:10.3390/molecules23112849 · Cited by 265
Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
Mian, Z., Hermayer, K. L., & Jenkins, A. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.07.003 · Cited by 139
Metadata
- Authors
- Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., & Flewitt, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-01-19
- Volume
- 17
- Issue
- 1
- Pages
- 182
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2577350032
- Cited by
- 291
- References
- 99
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.