The DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
The Progress of Glucose Monitoring—A Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors
Open accessAbstract
Current glucose monitoring methods for the ever-increasing number of diabetic people around the world are invasive, painful, time-consuming, and a constant burden for the household budget. The non-invasive glucose monitoring technology overcomes these limitations, for which this topic is significantly being researched and represents an exciting and highly sought after market for many companies. This review aims to offer an up-to-date report on the leading technologies for non-invasive (NI) and minimally-invasive (MI) glucose monitoring sensors, devices currently available in the market, regulatory framework for accuracy assessment, new approaches currently under study by representative groups and developers, and algorithm types for signal enhancement and value prediction. The review also discusses the future trend of glucose detection by analyzing the usage of the different bands in the electromagnetic spectrum. The review concludes that the adoption and use of new technologies for glucose detection is unavoidable and closer to become a reality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IDF Diabetes Atlas: Global estimates of diabetes prevalence for 2017 and projections for 2045
Cho, N. H., Shaw, J. E., Karuranga, S., Huang, Y., da Rocha Fernandes, J. D., Ohlrogge, A. W., & Malanda, B. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.02.023 · Cited by 7,283
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
International Organization for Standardization (ISO)
Nahler, G. (2009) · Dictionary of Pharmaceutical Medicine · doi:10.1007/978-3-211-89836-9_723 · Cited by 3,677
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Raman and infrared spectroscopy of carbohydrates: A review
Wiercigroch, E., Szafraniec, E., Czamara, K., Pacia, M. Z., Majzner, K., Kochan, K., Kaczor, A., Baranska, M., & Malek, K. (2017) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.05.045 · Cited by 1,067
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
High-Intensity Focused Ultrasound: Current Potential and Oncologic Applications
Dubinsky, T. J., Cuevas, C., Dighe, M. K., Kolokythas, O., & Hwang, J. H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2671 · Cited by 420
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Projection of the future diabetes burden in the United States through 2060
Lin, J., Thompson, T. J., Cheng, Y. J., Zhuo, X., Zhang, P., Gregg, E., & Rolka, D. B. (2018) · Population Health Metrics · doi:10.1186/s12963-018-0166-4 · Cited by 335
Bumbrah, G. S., & Sharma, R. M. (2016) · Egyptian Journal of Forensic Sciences · doi:10.1016/j.ejfs.2015.06.001 · Cited by 334
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Monte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Artificial Neural Network Algorithm for Online Glucose Prediction from Continuous Glucose Monitoring
Pérez-Gandía, C., Facchinetti, A., Sparacino, G., Cobelli, C., Gómez, E. J., Rigla, M., de Leiva, A., & Hernando, M. E. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0076 · Cited by 306
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Current and Emerging Technology for Continuous Glucose Monitoring
Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., & Flewitt, A. (2017) · Sensors · doi:10.3390/s17010182 · Cited by 291
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290
Fundamentals of Measurement in Terahertz Time-Domain Spectroscopy
Withayachumnankul, W., & Naftaly, M. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-013-0042-z · Cited by 288
Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2250516 · Cited by 288
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
A Tutorial on Near Infrared Spectroscopy and Its Calibration
Agelet, L. E., & Hurburgh, C. R. (2010) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2010.515468 · Cited by 280
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
Barone, P. W., Parker, R. S., & Strano, M. S. (2005) · Analytical Chemistry · doi:10.1021/ac0511997 · Cited by 279
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Glucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
Recent advances in noninvasive glucose monitoring
Chung, J., So, H., Choi, & Wong, T. K. S. (2012) · Medical Devices: Evidence and Research · doi:10.2147/mder.s28134 · Cited by 218
Schaare, P. N., & Fraser, D. G. (2000) · Postharvest Biology and Technology · doi:10.1016/s0925-5214(00)00130-7 · Cited by 212
Noninvasive Blood Glucose Monitoring
Klonoff, D. C. (1997) · Diabetes Care · doi:10.2337/diacare.20.3.433 · Cited by 208
Garg, S. K., Potts, R. O., Ackerman, N. R., Fermi, S. J., Tamada, J. A., & Chase, H. P. (1999) · Diabetes Care · doi:10.2337/diacare.22.10.1708 · Cited by 201
Advances in Photoacoustic Noninvasive Glucose Testing
MacKenzie, H. A., Ashton, H. S., Spiers, S., Shen, Y., Freeborn, S. S., Hannigan, J., Lindberg, J., & Rae, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1587 · Cited by 186
Fluorescence lifetime-based sensing and imaging
Szmacinski, H., & Lakowicz, J. R. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)01658-9 · Cited by 182
Ribet, F., Stemme, G., & Roxhed, N. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0349-6 · Cited by 181
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
Klonoff, D. C., Lias, C., Vigersky, R., Clarke, W., Parkes, J. L., Sacks, D. B., Kirkman, M. S., Kovatchev, B., Panel, T. E. G., Aurand, L., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539589 · Cited by 174
Saha, S., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I., Koutsoupidou, M., Palikaras, G., Mackenzie, R., Reeve, T., Kosmas, P., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06926-1 · Cited by 171
Sim, J. Y., Ahn, C.-G., Jeong, E.-J., & Kim, B. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19340-y · Cited by 161
Tseng, R. C., Chen, C.-C., Hsu, S., & Chuang, H.-S. (2018) · Sensors · doi:10.3390/s18082651 · Cited by 157
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
Challenges and perspectives in continuous glucose monitoring
van Enter, B. J., & von Hauff, E. (2018) · Chemical Communications · doi:10.1039/c8cc01678j · Cited by 149
Inoue, S., Egi, M., Kotani, J., & Morita, K. (2013) · Critical Care · doi:10.1186/cc12567 · Cited by 147
Noninvasive in vivo glucose sensing on human subjects using mid-infrared light
Liakat, S., Bors, K. A., Xu, L., Woods, C. M., Doyle, J., & Gmachl, C. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002397 · Cited by 146
Non-Invasive Glucose Monitoring: A Review of Challenges and Recent Advances
Lin, T. (2017) · Current Trends in Biomedical Engineering & Biosciences · doi:10.19080/ctbeb.2017.06.555696 · Cited by 146
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Overview of Fluorescence Glucose Sensing: A Technology with a Bright Future
Klonoff, D. C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600602 · Cited by 138
Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics
Kottmann, J., Rey, J. M., & Sigrist, M. W. (2016) · Sensors · doi:10.3390/s16101663 · Cited by 133
Fluorescent Nanobiosensors for Sensing Glucose
Chen, L., Hwang, E., & Zhang, J. (2018) · Sensors · doi:10.3390/s18051440 · Cited by 133
Significance and Reliability of MARD for the Accuracy of CGM Systems
Reiterer, F., Polterauer, P., Schoemaker, M., Schmelzeisen‐Redeker, G., Freckmann, G., Heinemann, L., & del Re, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662047 · Cited by 131
Burrin, J. M., & Price, C. P. (1985) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328502200401 · Cited by 129
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”
Amir, O., Weinstein, D., Zilberman, S., Less, M., Perl‐Treves, D., Primack, H., Weinstein, A., Gabis, E., Fikhte, B. A., & Karasik, A. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100403 · Cited by 125
Predictive Monitoring for Improved Management of Glucose Levels
Jaques Reifman, A., Rajaraman, S., Gribok, A. V., & Ward, W. K. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100405 · Cited by 123
Noninvasive blood glucose monitoring in the terahertz frequency range
Черкасова, О. П., Nazarov, M. M., & Shkurinov, A. P. (2016) · Optical and Quantum Electronics · doi:10.1007/s11082-016-0490-5 · Cited by 113
Noninvasive Measurement of Glucose by Metabolic Heat Conformation Method
Cho, O. K., Kim, Y. O., Mitsumaki, H., & Kuwa, K. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036954 · Cited by 105
A Novel Noninvasive Blood Glucose Monitor
Malchoff, C. D., Shoukri, K., Landau, J. I., & Buchert, J. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2268 · Cited by 96
Chen, L., Tse, W. H., Chen, Y., McDonald, M. W., Melling, C. W. J., & Zhang, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.044 · Cited by 91
Pendra goes Dutch: lessons for the CE mark in Europe
Wentholt, I. M. E., Hoekstra, J. B. L., Zwart, A., & DeVries, J. H. (2005) · Diabetologia · doi:10.1007/s00125-005-1754-y · Cited by 90
Palerm, C. C., & Bequette, B. W. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100505 · Cited by 89
Jafri, R. Z., BALLIRO, C. A., El-Khatib, F. H., MAHENO, M., HILLARD, M. A., O’Donovan, A. J., SELAGAMSETTY, R., Zheng, H., Damiano, E. R., & Russell, S. J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0449 · Cited by 89
Noninvasive Glucose Monitoring: A Novel Approach
Harman‐Boehm, I., Gal, A., Raykhman, A. M., Zahn, J. D., Naidis, E., & Mayzel, Y. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300205 · Cited by 88
Critical-depth Raman spectroscopy enables home-use non-invasive glucose monitoring
Lundsgaard-Nielsen, S. M., Pors, A., Banke, S. O., Henriksen, J. E., Hepp, D. K., & Weber, A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197134 · Cited by 87
A Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose
Ruan, J.-L., Chen, C., Shen, J., Zhao, X., Qian, S., & Zhu, Z. (2017) · Polymers · doi:10.3390/polym9040125 · Cited by 86
Harman‐Boehm, I., Gal, A., Raykhman, A. M., Naidis, E., & Mayzel, Y. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400312 · Cited by 85
Noninvasive Polarimetric-Based Glucose Monitoring: An in Vivo Study
Purvinis, G., Cameron, B. D., & Altrogge, D. M. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500227 · Cited by 85
Evaluation of Two Synthetic Glucose Probes for Fluorescence-Lifetime-Based Sensing
DiCésare, N., & Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5170 · Cited by 81
Microwave noninvasive blood glucose monitoring sensor: Human clinical trial results
Choi, H., Luzio, S. D., Beutler, J., & Porch, A. (2017) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2017.8058721 · Cited by 77
Pleitez, M. A., Lieblein, T., Bauer, A., Hertzberg, O., Lilienfeld-Toal, H. V., & Mäntele, W. (2013) · Review of Scientific Instruments · doi:10.1063/1.4816723 · Cited by 72
New Methodology to Obtain a Calibration Model for Noninvasive Near-Infrared Blood Glucose Monitoring
Maruo, K., Oota, T., Tsurugi, M., Nakagawa, T., Arimoto, H., Tamura, M., Ozaki, Y., & Yamada, Y. (2006) · Applied Spectroscopy · doi:10.1366/000370206776593780 · Cited by 72
Freckmann, G., Schmid, C., Baumstark, A., Rutschmann, M., Haug, C., & Heinemann, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815580160 · Cited by 70
Gamsey, S., Suri, J. T., Wessling, R. A., & Singaram, B. (2006) · Langmuir · doi:10.1021/la0617053 · Cited by 70
Tura, A., Sbrignadello, S., Cianciavicchia, D., Pacini, G., & Ravazzani, P. (2010) · Sensors · doi:10.3390/s100605346 · Cited by 63
Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
Siegel, P. H., Lee, Y., & Pikov, V. (2014) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2014.6956294 · Cited by 62
Single Walled Carbon Nanotubes as Reporters for the Optical Detection of Glucose
Barone, P. W., & Strano, M. S. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300204 · Cited by 61
Gourzi, M., Rouane, A., Guelaz, R., Alavi, M., McHugh, M. B., Nadi, M., & Roth, P. (2004) · Journal of Medical Engineering & Technology · doi:10.1080/03091900410001720247 · Cited by 60
Clinical Implications of Accuracy Measurements of Continuous Glucose Sensors
Bailey, T. S. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0050 · Cited by 60
Vega, K. C., Jiang, N., Liu, X., Kan, V., Barry, N., Maes, P., Yetisen, A. K., & Paradiso, J. A. (2017) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3123021.3123039 · Cited by 59
Glucose-sensitive silicone hydrogel contact lens toward tear glucose monitoring
Badugu, R., Reece, E. A., & Lakowicz, J. R. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.5.057005 · Cited by 58
Liakat, S., Bors, K. A., Huang, T., Michel, A. P. M., Zanghi, E., & Gmachl, C. F. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001083 · Cited by 56
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Kino, S., Omori, S., Katagiri, T., & Matsuura, Y. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000701 · Cited by 52
Non-invasive in vitro sensing of d -glucose in pig blood
Melikyan, H., Danielyan, E., Kim, S., Kim, J., Babajanyan, A., Lee, J., Friedman, B., & Lee, K. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.020 · Cited by 50
Analytical and Clinical Performance of Blood Glucose Monitors
Boren, S. A., & Clarke, W. L. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400111 · Cited by 49
Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography
Chen, T.-L., Lo, Y., Liao, C.-C., & Phan, Q.-H. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.047001 · Cited by 49
Lan, Y., Kuang, Y., Zhou, L. P., Wu, G., Gu, P., Wei, H., & Chen, K. (2017) · Laser Physics Letters · doi:10.1088/1612-202x/aa58c0 · Cited by 47
Ward, J. E. F., Stetson, B. A., & Mokshagundam, S. P. (2015) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/s40200-015-0172-z · Cited by 46
Cooke, D. D., Hurel, S. J., Casbard, A. C., Steed, L., Walker, S., Meredith, S. K., Nunn, A., Manca, A., Sculpher, M., Barnard, M., et al. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02723.x · Cited by 46
Non-Invasive Monitoring of Glucose Level Changes Utilizing a mm-Wave Radar System
Shaker, G. S. A., Smith, K., Omer, A. E., Liu, S., Csech, C., Wadhwa, U., Safavi‐Naeini, S., & Hughson, R. L. (2018) · International Journal of Mobile Human Computer Interaction · doi:10.4018/ijmhci.2018070102 · Cited by 46
Non-invasive polarimetric measurement of glucose concentration in the anterior chamber of the eye
Rawer, R., Stork, W., & Kreiner, C. F. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-1031-7 · Cited by 44
Patton, S. R., & Clements, M. A. (2012) · US Endocrinology · doi:10.17925/use.2012.08.01.27 · Cited by 42
Analysis: PENDRA: The Once and Future Noninvasive Continuous Glucose Monitoring Device?
Weinzimer, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041706018 · Cited by 37
Compact non-invasive millimeter-wave glucose sensor
Siegel, P. H., Tang, A. J., Virbila, G. L., Kim, Y. R., Chang, M.-C. F., & Pikov, V. (2015) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2015.7327413 · Cited by 37
Geddes, C. D., & Lakowicz, J. R. (2006) · Springer eBooks · doi:10.1007/0-387-33015-1 · Cited by 37
Continuous Glucose Monitoring in Youth with Type 1 Diabetes
Wadwa, R. P., Fiallo-Scharer, R. V., VanderWel, B., Messer, L. H., Cobry, E. C., & Chase, H. P. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0122 · Cited by 35
A Multiple Local Models Approach to Accuracy Improvement in Continuous Glucose Monitoring
Barceló-Rico, F., Bondía, J., Díez, J.-L., & Rossetti, P. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0138 · Cited by 34
Hadar, E., Chen, R., Toledano, Y., Tenenbaum-Gavish, K., Atzmon, Y., & Hod, M. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1463987 · Cited by 34
Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments
Pfützner, A., Strobl, S., Demircik, F., Redert, L., Pfützner, J., Pfützner, A. H., & Lier, A. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818758769 · Cited by 33
Use of the Cygnus GlucoWatch Biographer at a Diabetes Camp
Gandrud, L. M., Paguntalan, H. U., Wyhe, M. M. V., Kunselman, B., Leptien, A. D., Wilson, D. M., Eastman, R. C., & Buckingham, B. A. (2004) · PEDIATRICS · doi:10.1542/peds.113.1.108 · Cited by 33
Torii, T., Chiba, H., Tanabe, T., & Oyama, Y. (2017) · Digital Health · doi:10.1177/2055207617729534 · Cited by 33
Instrument for near infrared emission spectroscopic probing of human fingertips in vivo
Chaiken, J., Deng, B., Bussjager, R. J., Shaheen, G., Rice, D. A., Stehlik, D., & Fayos, J. (2010) · Review of Scientific Instruments · doi:10.1063/1.3314290 · Cited by 30
Accuracy of a Novel Noninvasive Transdermal Continuous Glucose Monitor in Critically Ill Patients
Saur, N. M., England, M. R., Menzie, W., Melanson, A. M., Trieu, M., Berlin, J., Hurley, J., Krystyniak, K., Kongable, G. L., & Nasraway, S. A. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814536138 · Cited by 30
Optical polarimetry for noninvasive glucose sensing enabled by Sagnac interferometry
Winkler, A. M., Bonnema, G. T., & Barton, J. K. (2011) · Applied Optics · doi:10.1364/ao.50.002719 · Cited by 29
Mahmoudi, Z., Johansen, M. D., Christiansen, J. S., & Hejlesen, O. K. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0041 · Cited by 29
Individualizing Care for the Many
Nardacci, E., Bode, B. W., & Hirsch, I. B. (2010) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721710362798 · Cited by 29
Continuous glucose monitoring and hypo/hyperglycaemia prediction
Sparacino, G., Zanderigo, F., Maran, A., & Cobelli, C. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(06)70023-7 · Cited by 26
Terahertz spectroscopy of biological molecules
Черкасова, О. П., Nazarov, M. M., Shkurinov, A. P., & Fedorov, V. I. (2009) · Radiophysics and Quantum Electronics · doi:10.1007/s11141-009-9152-9 · Cited by 26
A Real Time Simulation Model of Glucose-Insulin Metabolism for Type 1 Diabetes Patients
Mougiakakou, S. G., Prountzou, K., & Nikita, K. S. (2005) · doi:10.1109/iembs.2005.1616403 · Cited by 26
Blood Gas Analyzer Accuracy of Glucose Measurements
Liang, Y., Wanderer, J. P., Nichols, J. H., Klonoff, D. C., & Rice, M. J. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.03.009 · Cited by 26
Patton, S. R., & Clements, M. A. (2012) · PubMed · Cited by 25
The Need for Clinical Accuracy Guidelines for Blood Glucose Monitors
Klonoff, D. C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600101 · Cited by 25
Surface plasmon resonance based fiber optic glucose biosensor
Srivastava, S. K., Verma, R., & Gupta, B. D. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.915978 · Cited by 24
Li, D., Su, J., Yang, J., Yu, S., Zhang, J., Xu, K., & Yu, H. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.005206 · Cited by 24
Blood glucose prediction for diabetes therapy using a recurrent artificial neural network
Sandham, W. A., Nikoletou, D., Hamilton, D. J., Paterson, K., Japp, A. G., & MacGregor, C. (1998) · Research Repository (Kingston University London) · Cited by 22
Freckmann, G., Baumstark, A., Jendrike, N. R. M., Rittmeyer, D., Pleus, S., & Haug, C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0341 · Cited by 22
Jafri, R. Z., BALLIRO, C. A., El-Khatib, F. H., MAHENO, M., HILLARD, M. A., O’Donovan, A. J., SELAGAMSETTY, R., ZHENG, H., Damiano, E. R., & Russell, S. J. (2018) · Diabetes · doi:10.2337/db18-14-or · Cited by 20
Raman measurement of glucose in bioreactor materials
Xu, Y., Ford, J. F., Mann, C. K., Vickers, T. J., Brackett, J. M., Cousineau, K. L., & Robey, W. G. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.275527 · Cited by 18
Non-invasive Blood Glucose Monitoring and Data Analytics
Eadie, M., & Steele, R. J. (2017) · International Conference on Compute and Data Analysis (ICCDA) · doi:10.1145/3093241.3093283 · Cited by 17
Noninvasive Blood Glucose Measurement
Uwadaira, Y., & Ikehata, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812019-4.00036-2 · Cited by 16
LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors
Kirchsteiger, H., Zaccarian, L., Renard, É., & del Re, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2341703 · Cited by 15
Continous monitoring of blood glucose using photophlythesmograph signal
Philip, L. A., Rajasekaran, K., & Jothi, E. S. J. (2017) · International Conference on Innovations in Electrical, Electronics, Instrumentation and Media Technology (ICEEIMT) · doi:10.1109/icieeimt.2017.8116832 · Cited by 13
Noninvasive Glucose Measurement by Microwave Biosensor with Accuracy Enhancement
Zhang, R., Qu, Z., Jin, H., Liu, S., Luo, Y., & Zheng, Y. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351711 · Cited by 11
Fluorescence-Based Glucose Biosensors
Coté, G. L., McShane, M. J., & Shih, W. (2008) · Series in medical physics and biomedical engineering · doi:10.1201/9781584889755.ch11 · Cited by 8
Fluorescence‐Based Glucose Sensors
McShane, M. J., & Stein, E. W. (2009) · Wiley eBooks · doi:10.1002/9780470567319.ch10 · Cited by 5
Research works printed but not linked: 26
- Chakraborty, P.P., Patra, S., Bhattacharjee, R., and Chowdhury, S. (2017). Erroneously elevated glucose values due to maltose interference in mutant glucose dehydrogenase pyrroloquinolinequinone (mutant GDH-PQQ) based glucometer. BMJ Case Rep. · doi:10.1136/bcr-2017-219928
- China Food & Drug Administration (CFDA) (2016). Glucometer Registration Technical Review Guidelines.
- Jia, 2008, Carbon Nanotubes Based Glucose Needle-type Biosensor, Sensors, 8, 1712, 10.3390/s8031712 · doi:10.3390/s8031712
- Peng, H., Li, Q., and Chen, T. (2017). Chapter 5–Carbon Nanotubes for Sensing Applications. Industrial Applications of Carbon Nanotubes, Elsevier.
- Li, D.C., Wu, J.W., Wu, P., Lin, Y., Sun, Y.J., Zhu, R., Yang, J., and Xu, K.X. (2015, January 21–25). Glucose measurement using surface plasmon resonance sensor with affinity based surface modification by borate polymer. Proceedings of the 2015 Transducers-2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Anchorage, AK, USA. · doi:10.1109/transducers.2015.7181238
- Bambot, 1995, Sensing oxygen through skin using a red diode laser and fluorescence lifetimes, Biosens. Bioelectron., 10, 643, 10.1016/0956-5663(95)96941-Q · doi:10.1016/0956-5663(95)96941-q
- Malik, 2010, Real-time, closed-loop dual-wavelength optical polarimetry for glucose monitoring, J. Biomed. Opt., 15, 017002, 10.1117/1.3290819 · doi:10.1117/1.3290819
- Coates, 1998, Vibrational Spectroscopy: Instrumentation for Infrared and Raman Spectroscopy, Appl. Spectr. Rev., 33, 267, 10.1080/05704929808002060 · doi:10.1080/05704929808002060
- Xhelaj, 2005, A novel approach to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection, Vib. Spectr., 38, 209, 10.1016/j.vibspec.2005.02.025 · doi:10.1016/j.vibspec.2005.02.025
- Alarousu, E., Hast, J.T., Kinnunen, M.T., Kirillin, M.Y., Myllyla, R.A., Plucinski, J., Popov, A.P., Priezzhev, A.V., Prykari, T., and Saarela, J. (2003, January 7–10). Noninvasive glucose sensing in scattering media using OCT, PAS, and TOF techniques. Proceedings of the Saratov Fall Meeting 2003: Optical Technologies Biophysics and Medicine V, Saratov, Russia. · doi:10.1117/12.578321
- Gusev, S.I., Guseva, V.A., Simonova, A.A., Demchenko, P.S., Sedykh, E.A., Cherkasova, O.P., and Khodzitsky, M.K. (2017, January 22–25). Application of terahertz pulsed spectroscopy for the development of non-invasive glucose measuring method. Proceedings of the 2017 Progress In Electromagnetics Research Symposium-Spring (PIERS), St Petersburg, Russia. · doi:10.1109/piers.2017.8262313
- Buchert, 2004, Thermal emission spectroscopy as a tool for noninvasive blood glucose measurements, Proc. SPIE, 5566, 100, 10.1117/12.577219 · doi:10.1117/12.577219
- Tang, 2008, Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method, Sensors, 8, 3335, 10.3390/s8053335 · doi:10.3390/s8053335
- Sandeep, K.V., and Luong, J.H.T. (2016). Point-of-Care Glucose Detection for Diabetic Monitoring and Management, CRC Press. [1st ed.].
- Patel, 2013, A Review on Photoacoustic Spectroscopy, Int. J. Pharm. Erud., 3, 41
- Tanaka, Y., Tajima, T., and Seyama, M. (2018, January 19). Differential photoacoustic spectroscopy with continuous wave lasers for non-invasive blood glucose monitoring. Proceedings of the Photons Plus Ultrasound: Imaging and Sensing 2018, San Francisco, CA, USA. · doi:10.1117/12.2287039
- Nakamura, M., Tajima, T., Ajito, K., and Koizumi, H. (2016, January 22–27). Selectivity-enhanced glucose measurement in multicomponent aqueous solution by broadband dielectric spectroscopy. Proceedings of the 2016 IEEE MTT-S International Microwave Symposium (IMS), San Francisco, CA, USA. · doi:10.1109/mwsym.2016.7540257
- Bahar, A.A.M., Zakaria, Z., Isa, A.A.M., Alahnomi, R.A., and Rahman, N.A. (2018, January 19–22). Complex Permittivity Measurement Based on Planar Microfluidic Resonator Sensor. Proceedings of the 2018 18th International Symposium on Antenna Technology and Applied Electromagnetics (ANTEM), Waterloo, ON, Canada. · doi:10.1109/antem.2018.8572934
- Hofmann, M., Fersch, T., Weigel, R., Fischer, G., and Kissinger, D. (2011, January 30–31). A novel approach to non-invasive blood glucose measurement based on RF transmission. Proceedings of the 2011 IEEE International Symposium on Medical Measurements and Applications, Bari, Italy. · doi:10.1109/memea.2011.5966704
- Kim, 2008, Microwave dielectric resonator biosensor for aqueous glucose solution, Rev. Sci. Instrum., 79, 086107, 10.1063/1.2968115 · doi:10.1063/1.2968115
- Yilmaz, T., Brizzi, A., Foster, R., Munoz, M., and Hao, Y. (2014, January 16–23). A patch resonator for sensing blood glucose changes. Proceedings of the 2014 XXXIth URSI General Assembly and Scientific Symposium (URSI GASS), Beijing, China. · doi:10.1109/ursigass.2014.6930125
- Kost, 2002, Ultrasound-Assisted Insulin Delivery and Noninvasive Glucose Sensing, Diabetes Technol. Ther., 4, 489, 10.1089/152091502760306571 · doi:10.1089/152091502760306571
- Siegel, P.H., Tang, A., Kim, R., Virbila, G., Chang, F., and Pikov, V. (September, January 27). Noninvasive in vivo millimeter-wave measurements of glucose: First results in human subjects. Proceedings of the 2017 42nd International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), Cancun, Mexico. · doi:10.1109/irmmw-thz.2017.8067035
- Zanon, M., Sparacino, G., Facchinetti, A., Talary, S.M., Mueller, M., Caduff, A., and Cobelli, C. (2013). Non-Invasive Continuous Glucose Monitoring with Multi-Sensor Systems: A Monte Carlo-Based Methodology for Assessing Calibration Robustness. Sensors, 13. · doi:10.3390/s130607279
- Tresp, 1999, Neural-network models for the blood glucose metabolism of a diabetic, IEEE Trans. Neural Netw., 10, 1204, 10.1109/72.788659 · doi:10.1109/72.788659
- Smith, J. (2018, December 14). Available online: https://www.researchgate.net/publication/317267760_The_Pursuit_of_Noninvasive_Glucose_5th_Edition.
Cited by
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112331 · Cited by 327
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Metadata
- Authors
- Villena Gonzales, W., Mobashsher, A., & Abbosh, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-02-15
- Volume
- 19
- Issue
- 4
- Pages
- 800
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2914059200
- Cited by
- 772
- References
- 130
- FWCI
- 60.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.