Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
The DOI matches its Crossref record; 608 of the 610 references it cites were found in a registry or an index.
Abstract
Significant advances in biomaterials, stem cell biology, and microscale technologies have enabled the fabrication of biologically relevant tissues and organs. Such tissues and organs, referred to as organ-on-a-chip (OOC) platforms, have emerged as a powerful tool in tissue analysis and disease modeling for biological and pharmacological applications. A variety of biomaterials are used in tissue fabrication providing multiple biological, structural, and mechanical cues in the regulation of cell behavior and tissue morphogenesis. Cells derived from humans enable the fabrication of personalized OOC platforms. Microscale technologies are specifically helpful in providing physiological microenvironments for tissues and organs. In this review, biomaterials, cells, and microscale technologies are described as essential components to construct OOC platforms. The latest developments in OOC platforms (e.g., liver, skeletal muscle, cardiac, cancer, lung, skin, bone, and brain) are then discussed as functional tools in simulating human physiology and metabolism. Future perspectives and major challenges in the development of OOC platforms toward accelerating clinical studies of drug discovery are finally highlighted.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These platforms contain more complex and sophisticated topographical and biomechanical cues for human tissue modelling than a thin layer of cells [360].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [360]
Citations
Cites
1 retracted
Items 201–400 of 608
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Rapid formation of functional muscle in vitro using fibrin gels
Huang, Y.-C., Dennis, R. G., Larkin, L., & Baar, K. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00273.2004 · Cited by 316
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Grellier, M., Bordenave, L., & Amédée, J. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.07.001 · Cited by 310
Influence of food and diet on gastrointestinal drug absorption: A review
Welling, P. G. (1977) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01061694 · Cited by 307
Microfabrication and microfluidics for tissue engineering: state of the art and future opportunities
Andersson, H., & Berg, A. V. D. (2004) · Lab on a Chip · doi:10.1039/b314469k · Cited by 307
Mohammed, M.-I., & Desmulliez, M. P. Y. (2011) · Lab Chip · doi:10.1039/c0lc00204f · Cited by 304
Skeletal muscle tissue engineering: methods to form skeletal myotubes and their applications
Ostrovidov, S., Hosseini, V., Ahadian, S., Fujie, T., Parthiban, S. P., Ramalingam, M., Bae, H., Kaji, H., & Khademhosseini, A. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2013.0534 · Cited by 302
Self-citationSasagawa, T., Shimizu, T., Sekiya, S., Haraguchi, Y., Yamato, M., Sawa, Y., & Okano, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.036 · Cited by 301
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Skin integrated with perfusable vascular channels on a chip
Mori, N., Morimoto, Y., & Takeuchi, S. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.11.031 · Cited by 294
Fibrin glue: the perfect operative sealant?
Gibble, J. W., & Ness, P. M. (1990) · Transfusion · doi:10.1046/j.1537-2995.1990.30891020337.x · Cited by 293
Park, H., Temenoff, J. S., Holland, T. A., Tabata, Y., & Mikos, A. G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.083 · Cited by 293
Uludag, Y., & Tothill, I. E. (2012) · Analytical Chemistry · doi:10.1021/ac300278p · Cited by 290
Kimura, H., Yamamoto, T., Sakai, H., Sakai, Y., & Fujii, T. (2008) · Lab on a Chip · doi:10.1039/b717091b · Cited by 290
Electrical and mechanical stimulation of cardiac cells and tissue constructs
Stoppel, W. L., Kaplan, D. L., & Black, L. D. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.07.009 · Cited by 289
Formation and optogenetic control of engineered 3D skeletal muscle bioactuators
Sakar, M. S., Neal, D., Boudou, T., Borochin, M. A., Li, Y., Weiss, R., Kamm, R. D., Chen, C. S., & Asada, H. H. (2012) · Lab on a Chip · doi:10.1039/c2lc40338b · Cited by 288
Jeong, S.-Y., Lee, J.-H., Shin, Y., Chung, S., & Kuh, H.-J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0159013 · Cited by 287
Gumbleton, M., & Audus, K. L. (2001) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.1119 · Cited by 286
Ho, C.-T., Lin, R.-Z., Chang, W.-Y., Chang, H.-Y., & Liu, C.-H. (2006) · Lab on a Chip · doi:10.1039/b602036d · Cited by 283
Esch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00371c · Cited by 281
Ramón‐Azcón, J., Ahadian, S., Estili, M., Liang, X., Ostrovidov, S., Kaji, H., Shiku, H., Ramalingam, M., Nakajima, K., Sakka, Y., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301300 · Cited by 278
Self-citationCurrent approaches to electrospun nanofibers for tissue engineering
Rim, N. G., Shin, C. S., & Shin, H. (2013) · Biomedical Materials · doi:10.1088/1748-6041/8/1/014102 · Cited by 277
Ataç, B., Wagner, I., Horland, R., Lauster, R., Marx, U., Tonevitsky, A. G., Azar, R. P., & Lindner, G. (2013) · Lab on a Chip · doi:10.1039/c3lc50227a · Cited by 272
Charest, J. L., García, A. J., & King, W. P. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.020 · Cited by 272
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Development of a microphysiological model of human kidney proximal tubule function
Weber, E. J., Chapron, A., Chapron, B. D., Voellinger, J. L., Lidberg, K. A., Yeung, C. K., Wang, Z., Yamaura, Y., Hailey, D. W., Neumann, T., et al. (2016) · Kidney International · doi:10.1016/j.kint.2016.06.011 · Cited by 272
Zaari, N., Rajagopalan, P., Kim, S. K., Engler, A. J., & Wong, J. Y. (2004) · Advanced Materials · doi:10.1002/adma.200400883 · Cited by 268
Prevascularization in tissue engineering: Current concepts and future directions
Laschke, M. W., & Menger, M. D. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.004 · Cited by 266
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 265
Laser‐guided direct writing for three‐dimensional tissue engineering
Nahmias, Y., Schwartz, R. E., Verfaillie, C. M., & Odde, D. J. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20585 · Cited by 264
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac051856v · Cited by 264
Kostadinova, R., Boess, F., Applegate, D., Suter, L., Weiser, T., Singer, T., Naughton, B., & Roth, A. (2013) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2013.01.012 · Cited by 262
Pumpless microfluidic platform for drug testing on human skin equivalents
Abaci, H. E., Gledhill, K., Guo, Z., Christiano, A. M., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c4lc00999a · Cited by 262
The multicellular tumor spheroid model for high-throughput cancer drug discovery
LaBarbera, D. V., Reid, B. G., & Yoo, B. H. (2012) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2012.708334 · Cited by 255
Dikovsky, D., Bianco-Peled, H., & Seliktar, D. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.038 · Cited by 254
Biomaterials for Tissue Engineering
Lee, E. J., Kasper, F. K., & Mikos, A. G. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0859-6 · Cited by 252
Evaluation of gastrointestinal drug supersaturation and precipitation: Strategies and issues
Bevernage, J., Brouwers, J., Brewster, M. E., & Augustijns, P. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.11.026 · Cited by 250
Maturing human pluripotent stem cell-derived cardiomyocytes in human engineered cardiac tissues
Feric, N. T., & Radisic, M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.019 · Cited by 247
Self-citationMicrofluidic Models of Vascular Functions
Wong, K. H. K., Chan, J. M., Kamm, R. D., & Tien, J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150052 · Cited by 247
Accelerated de novo sarcomere assembly by electric pulse stimulation in C2C12 myotubes
Fujita, H., Nedachi, T., & Kanzaki, M. (2007) · Experimental Cell Research · doi:10.1016/j.yexcr.2007.03.002 · Cited by 244
Recombinant human collagen for tissue engineered corneal substitutes
Liu, W., Merrett, K., Griffith, M., Fagerholm, P., Dravida, S., Heyne, B., Scaiano, J. C., Watsky, M. A., Shinozaki, N., Lagali, N., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.011 · Cited by 244
Temperature-responsive intelligent interfaces for biomolecular separation and cell sheet engineering
Nagase, K., Kobayashi, J., & Okano, T. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0499.focus · Cited by 241
Micromolded gelatin hydrogels for extended culture of engineered cardiac tissues
McCain, M. L., Agarwal, A., Nesmith, H. W., Nesmith, A. P., & Parker, K. K. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.052 · Cited by 237
Fujimoto, K. L., Tobita, K., Merryman, W. D., Guan, J., Momoi, N., Stolz, D. B., Sacks, M. S., Keller, B. B., & Wagner, W. R. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.050 · Cited by 236
Cell sheet approach for tissue engineering and regenerative medicine
Matsuura, K., Utoh, R., Nagase, K., & Okano, T. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.024 · Cited by 234
Biomaterials in myocardial tissue engineering: Biomaterials in myocardial tissue engineeringcpr
Reis, L. A., Chiu, L. L. Y., Feric, N., Fu, L., & Radisic, M. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1944 · Cited by 233
Self-citationLiver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Skardal, A., Devarasetty, M., Forsythe, S., Atala, A., & Soker, S. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25950 · Cited by 230
Blood–brain barrier dysfunction, seizures and epilepsy
van Vliet, E. A., Aronica, E., & Gorter, J. A. (2015) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2014.10.003 · Cited by 229
A human liver microphysiology platform for investigating physiology, drug safety, and disease models
Vernetti, L. A., Senutovitch, N., Boltz, R., DeBiasio, R., Ying Shun, T., Gough, A., & Taylor, D. L. (2016) · Experimental Biology and Medicine · doi:10.1177/1535370215592121 · Cited by 226
Effect of parallel surface microgrooves and surface energy on cell growth
Den Braber, E. T., de Ruijter, J. E., Smits, H. T. J., Ginsel, L. A., von Recum, A. F., & Jansen, J. A. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290411 · Cited by 221
Maschmeyer, I., Hasenberg, T., Jaenicke, A., Lindner, M., Lorenz, A. K., Zech, J., Garbe, L.-A., Sonntag, F., Hayden, P., Ayehunie, S., et al. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.03.002 · Cited by 218
Feng, Z.-Q., Chu, X., Huang, N.-P., Wang, T., Wang, Y., Shi, X., Ding, Y., & Gu, Z.-Z. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.053 · Cited by 216
Doerr, M. E., & Jones, J. I. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.5.2443 · Cited by 216
Douville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Lab Chip · doi:10.1039/c0lc00251h · Cited by 216
Yu, J., Gu, Y., Du, K. T., Mihardja, S., Sievers, R. E., & Lee, R. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.059 · Cited by 214
Polte, T. R., Eichler, G. S., Wang, N., & Ingber, D. E. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00280.2003 · Cited by 214
Long‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
A Mouse Model of Human Breast Cancer Metastasis to Human Bone
Kuperwasser, C., Dessain, S., Bierbaum, B. E., Garnet, D., Sperandio, K., Gauvin, G. P., Naber, S. P., Weinberg, R. A., & Rosenblatt, M. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-1408 · Cited by 212
Golpon, H. A., Fadok, V. A., Taraseviciene-Stewart, L., Scerbavicius, R., Sauer, C., Welte, T., Henson, P. M., & Voelkel, N. F. (2004) · The FASEB Journal · doi:10.1096/fj.04-1853fje · Cited by 211
Bilic, J., & Belmonte, J. C. I. (2012) · STEM CELLS · doi:10.1002/stem.700 · Cited by 210
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Use of Micropatterned Cocultures to Detect Compounds That Cause Drug-Induced Liver Injury in Humans
Khetani, S. R., Kanchagar, C., Ukairo, O., Krzyzewski, S., Moore, A., Shi, J., Aoyama, S., Aleo, M., & Will, Y. (2013) · Toxicological Sciences · doi:10.1093/toxsci/kfs326 · Cited by 208
Systematic reviews of animal models: methodology versus epistemology
Greek, R., & Menache, A. (2013) · International Journal of Medical Sciences · doi:10.7150/ijms.5529 · Cited by 207
Lam, M. T., Sim, S., Zhu, X., & Takayama, S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.04.012 · Cited by 205
Buchanan, C. F., Verbridge, S. S., Vlachos, P. P., & Rylander, M. N. (2014) · Cell Adhesion & Migration · doi:10.4161/19336918.2014.970001 · Cited by 205
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
A parallel-gradient microfluidic chamber for quantitative analysis of breast cancer cell chemotaxis
Saadi, W., Wang, S.-J., Lin, F., & Jeon, N. L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-7706-6 · Cited by 204
Engineered Osteochondral Grafts Using Biphasic Composite Solid Free-Form Fabricated Scaffolds
Schek, R. M., Taboas, J. M., Segvich, S. J., Hollister, S. J., & Krebsbach, P. H. (2004) · Tissue Engineering · doi:10.1089/ten.2004.10.1376 · Cited by 203
In vitro micro-physiological immune-competent model of the human skin
Ramadan, Q., & Ting, F. C. W. (2016) · Lab on a Chip · doi:10.1039/c6lc00229c · Cited by 203
Dai, X., Zhou, W., Gao, T., Liu, J., & Lieber, C. M. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.96 · Cited by 202
Transport‐mediated angiogenesis in 3D epithelial coculture
Sudo, R., Chung, S., Zervantonakis, I. K., Vickerman, V., Toshimitsu, Y., Griffith, L. G., & Kamm, R. D. (2009) · The FASEB Journal · doi:10.1096/fj.08-122820 · Cited by 201
Extracellular matrix, mechanotransduction and structural hierarchies in heart tissue engineering
Parker, K. K., & Ingber, D. E. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2114 · Cited by 200
Organs-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
Au, H. T. H., Cheng, I., Chowdhury, M. F., & Radisic, M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.001 · Cited by 197
Self-citationThree-dimensional neuron–muscle constructs with neuromuscular junctions
Morimoto, Y., Kato-Negishi, M., Onoe, H., & Takeuchi, S. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.062 · Cited by 195
Progress in using systematic reviews of animal studies to improve translational research
Hooijmans, C. R., & Ritskes-Hoitinga, M. (2013) · PLoS Medicine · doi:10.1371/journal.pmed.1001482 · Cited by 195
Wang, C.-C., Yang, K.-C., Lin, K.-H., Liu, H.-C., & Lin, F.-H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.018 · Cited by 191
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
Wolff, A., Antfolk, M., Brodin, B., & Tenje, M. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24329 · Cited by 191
Articular cartilage tissue engineering: TODAY’S RESEARCH, TOMORROW’S PRACTICE?
Getgood, A., Brooks, R., Fortier, L., & Rushton, N. (2009) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.91b5.21832 · Cited by 191
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Nguyen, T. A., Yin, T.-I., Reyes, D., & Urban, G. A. (2013) · Analytical Chemistry · doi:10.1021/ac402761s · Cited by 189
The emergence of ECM mechanics and cytoskeletal tension as important regulators of cell function
Peyton, S. R., Ghajar, C. M., Khatiwala, C. B., & Putnam, A. J. (2007) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-007-0004-y · Cited by 188
Cho, I.-H., Paek, E.-H., Kim, Y.-K., Kim, J.-H., & Paek, S.-H. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.11.019 · Cited by 187
Cell Lines as In Vitro Models for Drug Screening and Toxicity Studies
Allen, D. D., Caviedes, R., Cárdenas, A. M., Shimahara, T., Segura‐Aguilar, J., & Caviedes, P. A. (2005) · Drug Development and Industrial Pharmacy · doi:10.1080/03639040500216246 · Cited by 185
Viravaidya, K., & Shuler, M. L. (2004) · Biotechnology Progress · doi:10.1021/bp034238d · Cited by 184
Three-Dimensional Blood-Brain Barrier Model for in vitro Studies of Neurovascular Pathology
Cho, H., Seo, J. H., Wong, K. H. K., Terasaki, Y., Park, J., Bong, K., Arai, K., Lo, E. H., & Irimia, D. (2015) · Scientific Reports · doi:10.1038/srep15222 · Cited by 184
An osteoconductive collagen/hyaluronate matrix for bone regeneration
Liu, L.-S., Thompson, A. Y., Heidaran, M. A., Poser, J. W., & Spiro, R. C. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00006-x · Cited by 183
Fluorescence lifetime-based sensing and imaging
Szmacinski, H., & Lakowicz, J. R. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)01658-9 · Cited by 182
Washburn, A. L., & Bailey, R. C. (2011) · The Analyst · doi:10.1039/c0an00449a · Cited by 182
Formation of microvascular networks in vitro
Morgan, J. P., Delnero, P. F., Zheng, Y., Verbridge, S. S., Chen, J., Craven, M., Choi, N. W., Diaz-Santana, A., Kermani, P., Hempstead, B., et al. (2013) · Nature Protocols · doi:10.1038/nprot.2013.110 · Cited by 181
Integrating biological vasculature into a multi-organ-chip microsystem
Schimek, K., Busek, M., Brincker, S., Groth, B., Hoffmann, S., Lauster, R., Lindner, G., Lorenz, A., Menzel, U., Sonntag, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50217a · Cited by 180
Cellular control of tissue architectures using a three-dimensional tissue fabrication technique
Tsuda, Y., Shimizu, T., Yamato, M., Kikuchi, A., Sasagawa, T., Sekiya, S., Kobayashi, J., Chen, G., & Okano, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.002 · Cited by 180
Ahadian, S., Yamada, S., Ramón-Azcón, J., Estili, M., Liang, X., Nakajima, K., Shiku, H., Khademhosseini, A., & Matsue, T. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.047 · Cited by 180
Self-citationConcave microwell based size-controllable hepatosphere as a three-dimensional liver tissue model
Wong, S. F., No, D. Y., Choi, Y. Y., Kim, D. S., Chung, B. G., & Lee, S.-H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.07.028 · Cited by 178
A versatile lab-on-a-chip tool for modeling biological barriers
Walter, F. R., Valkai, S., Kincses, A., Petneházi, A., Czeller, T., Veszelka, S., Ormos, P., Deli, M. A., & Dér, A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.110 · Cited by 177
Microfluidic compartmentalized co-culture platform for CNS axon myelination research
Park, J., Koito, H., Li, J., & Han, A. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9331-7 · Cited by 177
Optimization of the HepaRG cell model for drug metabolism and toxicity studies
Anthérieu, S., Chesné, C., Li, R., Guguen-Guillouzo, C., & Guillouzo, A. (2012) · Toxicology in Vitro · doi:10.1016/j.tiv.2012.05.008 · Cited by 177
A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces
Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701199 · Cited by 175
Electrochemical Properties of Nanostructured Porous Gold Electrodes in Biofouling Solutions
Patel, J., Radhakrishnan, L., Zhao, B., Uppalapati, B., Daniels, R. C., Ward, K. R., & Collinson, M. M. (2013) · Analytical Chemistry · doi:10.1021/ac403013r · Cited by 172
Riahi, R., Shaegh, S. A. M., Ghaderi, M., Zhang, Y. S., Shin, S. R., Aleman, J., Massa, S., Kim, D., Dokmeci, M. R., & Khademhosseini, A. (2016) · Scientific Reports · doi:10.1038/srep24598 · Cited by 172
Perfusable branching microvessel bed for vascularization of engineered tissues
Chiu, L. L. Y., Montgomery, M., Liang, Y., Liu, H., & Radisic, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210580109 · Cited by 171
Self-citationOptical Oxygen Sensors for Applications in Microfluidic Cell Culture
Grist, S. M., Chrostowski, L., & Cheung, K. C. (2010) · Sensors · doi:10.3390/s101009286 · Cited by 169
KONDOH, H., SAWA, Y., MIYAGAWA, S., SAKAKIDAKITAGAWA, S., MEMON, I., KAWAGUCHI, N., MATSUURA, N., SHIMIZU, T., OKANO, T., & MATSUDA, H. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.005 · Cited by 169
Ramón-Azcón, J., Ahadian, S., Obregón, R., Camci-Unal, G., Ostrovidov, S., Hosseini, V., Kaji, H., Ino, K., Shiku, H., Khademhosseini, A., et al. (2012) · Lab on a Chip · doi:10.1039/c2lc40213k · Cited by 167
Self-citationWang, X.-Y., Jin, Z.-H., Gan, B.-W., Lv, S.-W., Xie, M., & Huang, W.-H. (2014) · Lab Chip · doi:10.1039/c4lc00069b · Cited by 166
In vitro 3D collective sprouting angiogenesis under orchestrated ANG-1 and VEGF gradients
Shin, Y., Jeon, J. S., Han, S., Jung, G.-S., Shin, S., Lee, S.-H., Sudo, R., Kamm, R. D., & Chung, S. (2011) · Lab on a Chip · doi:10.1039/c1lc20039a · Cited by 166
Diverse approaches for the enhancement of oral drug bioavailability
Fasinu, P., Pillay, V., Ndesendo, V. M. K., du Toit, L. C., & Choonara, Y. E. (2011) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.750 · Cited by 166
Collagen-based brain microvasculature modelin vitrousing three-dimensional printed template
Kim, J., Kim, H. N., Im, S.-K., Chung, S. H., Kang, J. Y., & Choi, N. (2015) · Biomicrofluidics · doi:10.1063/1.4917508 · Cited by 166
Cucullo, L., Marchi, N., Hossain, M., & Janigro, D. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.162 · Cited by 166
A multi-organ chip co-culture of neurospheres and liver equivalents for long-term substance testing
Dehne, E., Ramme, A. P., Terrasso, A. P., Serra, M., Alves, P. M., Brito, C., Sakharov, D. A., Tonevitsky, A., Lauster, R., & Marx, U. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.02.002 · Cited by 165
How multi-organ microdevices can help foster drug development
Esch, M. B., Smith, A. S. T., Prot, J. M., Oleaga, C., Hickman, J. J., & Shuler, M. L. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.003 · Cited by 165
Fukuda, J., Sakai, Y., & Nakazawa, K. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.031 · Cited by 165
Kang, Y. B. (., Sodunke, T. R., Lamontagne, J., Cirillo, J., Rajiv, C., Bouchard, M. J., & Noh, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25659 · Cited by 165
Effect of Electromechanical Stimulation on the Maturation of Myotubes on Aligned Electrospun Fibers
Liao, I.-C., Liu, J. B., Bursac, N., & Leong, K. W. (2008) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-008-0021-y · Cited by 164
Biomaterial based cardiac tissue engineering and its applications
Huyer, L. D., Montgomery, M., Zhao, Y., Xiao, Y., Conant, G., Korolj, A., & Radisic, M. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034004 · Cited by 164
Self-citationToward modeling the bone marrow niche using scaffold-based 3D culture systems
Di Maggio, N., Piccinini, E., Jaworski, M., Trumpp, A., Wendt, D. J., & Martin, I. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.041 · Cited by 163
Marx-Stoelting, P., Adriaens, E., Ahr, H.-J., Bremer, S., Garthoff, B., Gelbke, H.-P., Piersma, A., Pellizzer, C., Reuter, U., Rogiers, V., et al. (2009) · Alternatives to Laboratory Animals · doi:10.1177/026119290903700314 · Cited by 163
Moldable elastomeric polyester-carbon nanotube scaffolds for cardiac tissue engineering
Ahadian, S., Davenport Huyer, L., Estili, M., Yee, B., Smith, N., Xu, Z., Sun, Y., & Radisic, M. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.12.009 · Cited by 163
Self-citationThe influence of substrate stiffness on the behavior and functions of Schwann cells in culture
Gu, Y., Ji, Y., Zhao, Y., Liu, Y., Ding, F., Gu, X., & Yang, Y. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.006 · Cited by 162
Self-citationZhou, M., Zhang, X., Wen, X., Wu, T., Wang, W., Yang, M., Wang, J., Fang, M., Lin, B., & Lin, H. (2016) · Scientific Reports · doi:10.1038/srep31771 · Cited by 162
Synthesis and characterization of a biodegradable elastomer featuring a dual crosslinking mechanism
Tran, R. T., Thevenot, P., Gyawali, D., Chiao, J. ‐., Tang, L., & Yang, J. Y. (2010) · Soft Matter · doi:10.1039/c001605e · Cited by 161
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
van der Meer, A. D., Orlova, V. V., ten Dijke, P., van den Berg, A., & Mummery, C. L. (2013) · Lab on a Chip · doi:10.1039/c3lc50435b · Cited by 160
Mousavi Shaegh, S. A., De Ferrari, F., Zhang, Y. S., Nabavinia, M., Binth Mohammad, N., Ryan, J., Pourmand, A., Laukaitis, E., Banan Sadeghian, R., Nadhman, A., et al. (2016) · Biomicrofluidics · doi:10.1063/1.4955155 · Cited by 160
Sung, K. E., Su, G., Pehlke, C., Trier, S. M., Eliceiri, K. W., Keely, P. J., Friedl, A., & Beebe, D. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.043 · Cited by 159
Chen, G., Ushida, T., & Tateishi, T. (2000) · Advanced Materials · doi:10.1002/(sici)1521-4095(200003)12:6<455::aid-adma455>3.0.co;2-c · Cited by 159
van Susante, J. L. C., Buma, P., Schuman, L., Homminga, G. N., van den Berg, W. B., & Veth, R. P. H. (1999) · Biomaterials · doi:10.1016/s0142-9612(97)00190-7 · Cited by 159
Du, C., Narayanan, K., Leong, M. F., & Wan, A. C. A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.011 · Cited by 158
Dermal Patch with Integrated Flexible Heater for on Demand Drug Delivery
Bagherifard, S., Tamayol, A., Mostafalu, P., Akbari, M., Comotto, M., Annabi, N., Ghaderi, M., Sonkusale, S., Dokmeci, M. R., & Khademhosseini, A. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500357 · Cited by 158
Cheng, Y., Yu, Y., Fu, F., Wang, J., Shang, L., Gu, Z., & Zhao, Y. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11445 · Cited by 158
Self-citationEstablishment of 3D organotypic cultures using human neonatal epidermal cells
Gangatirkar, P., Paquet‐Fifield, S., Li, A., Rossi, R., & Kaur, P. (2007) · Nature Protocols · doi:10.1038/nprot.2006.448 · Cited by 156
Stem cells and tissue engineering: past, present, and future
POLAK, J. M., & BISHOP, A. E. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1346.001 · Cited by 155
Microelectronic sensor system for microphysiological application on living cells
Baumann, W. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00116-1 · Cited by 155
Microfluidic vascularized bone tissue model with hydroxyapatite-incorporated extracellular matrix
Jusoh, N., Oh, S., Kim, S., Jangho, K., & Jeon, N. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00698h · Cited by 153
Sequential BMP‐2/BMP‐7 delivery from polyester nanocapsules
Yilgor, P., Hasırcı, N., & Hasırcı, V. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32520 · Cited by 153
DECREASED mRNA EXPRESSION OF TIGHT JUNCTION PROTEINS IN LUMBAR SPINAL CORDS OF PATIENTS WITH ALS
Henkel, J. S., Beers, D. R., Wen, S., Bowser, R., & Appel, S. H. (2009) · Neurology · doi:10.1212/wnl.0b013e3181a41228 · Cited by 153
A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime
Zhang, Q., Liu, T., & Qin, J. (2012) · Lab on a Chip · doi:10.1039/c2lc00030j · Cited by 151
Li, B., Davidson, J. M., & Guelcher, S. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.008 · Cited by 149
Tatosian, D. A., & Shuler, M. L. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22219 · Cited by 149
Localized insulin-like growth factor I delivery to enhance new bone formation
Meinel, L., Zoidis, E., Zapf, J., Hassa, P. O., Hottiger, M. O., Auer, J. A., Schneider, R., Gander, B. A., Luginbuehl, V., Bettschart‐Wolfensberger, R., et al. (2003) · Bone · doi:10.1016/s8756-3282(03)00207-2 · Cited by 149
Reliable permeability assay system in a microfluidic device mimicking cerebral vasculatures
Yeon, J. H., Na, D., Choi, K., Ryu, S., Choi, C., & Park, J. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9680-5 · Cited by 148
Merrett, K., Fagerholm, P., McLaughlin, C. R., Dravida, S., Lagali, N., Shinozaki, N., Watsky, M. A., Munger, R., Kato, Y., Li, F., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1348 · Cited by 146
Zhou, Q., Patel, D., Kwa, T., Haque, A., Matharu, Z., Stybayeva, G., Gao, Y., Diehl, A. M., & Revzin, A. (2015) · Lab on a Chip · doi:10.1039/c5lc00874c · Cited by 145
A microfluidic wound-healing assay for quantifying endothelial cell migration
van der Meer, A. D., Vermeul, K., Poot, A. A., Feijén, J., & Vermes, I. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00933.2009 · Cited by 145
Microfabricated perfusable cardiac biowire: a platform that mimics native cardiac bundle
Xiao, Y., Zhang, B., Liu, H., Miklas, J. W., Gagliardi, M., Pahnke, A., Thavandiran, N., Sun, Y., Simmons, C., Keller, G., et al. (2014) · Lab Chip · doi:10.1039/c3lc51123e · Cited by 144
Self-citationBrain-on-a-chip model enables analysis of human neuronal differentiation and chemotaxis
Kilic, O., Pamies, D., Lavell, E., Schiapparelli, P., Feng, Y., Hartung, T., Bal-Price, A., Hogberg, H. T., Quinones-Hinojosa, A., Guerrero-Cazares, H., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00946h · Cited by 144
Young, E. W. K. (2013) · Integrative Biology · doi:10.1039/c3ib40076j · Cited by 143
Maruotti, J., Sripathi, S. R., Bharti, K., Fuller, J., Wahlin, K. J., Ranganathan, V., Sluch, V. M., Berlinicke, C. A., Davis, J., Kim, C., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1422818112 · Cited by 142
Use of Flow, Electrical, and Mechanical Stimulation to Promote Engineering of Striated Muscles
Rangarajan, S., Madden, L. R., & Bursac, N. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0966-4 · Cited by 141
Nichols, J. E., Cortiella, J., Lee, J., Niles, J. A., Cuddihy, M., Wang, S., Bielitzki, J., Cantu, A., Mlcak, R., Valdivia, E., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.041 · Cited by 140
Ohlin, K. E., Francardo, V., Lindgren, H. S., Sillivan, S. E., O’Sullivan, S. S., Luksik, A. S., Vassoler, F. M., Lees, A. J., Konradi, C., & Cenci, M. A. (2011) · Brain · doi:10.1093/brain/awr165 · Cited by 140
Plouffe, B. D., Njoka, D. N., Harris, J., Liao, J., Horick, N. K., Radisic, M., & Murthy, S. K. (2007) · Langmuir · doi:10.1021/la0700220 · Cited by 139
Self-citationSung, J. H., Srinivasan, B., Esch, M. B., McLamb, W., Bernabini, C., Shuler, M. L., & Hickman, J. J. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214529397 · Cited by 139
Functional differentiation of human pluripotent stem cells on a chip
Giobbe, G. G., Michielin, F., Luni, C., Giulitti, S., Martewicz, S., Dupont, S., Floreani, A., & Elvassore, N. (2015) · Nature Methods · doi:10.1038/nmeth.3411 · Cited by 138
Kikuchi, Y., Sato, K., Ohki, H., & Kaneko, T. (1992) · Microvascular Research · doi:10.1016/0026-2862(92)90082-z · Cited by 138
Wang, L., Liu, W., Wang, Y., Wang, J., Tu, Q., Liu, R., & Wang, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40661f · Cited by 137
Namdee, K., Thompson, A. J., Charoenphol, P., & Eniola-Adefeso, O. (2013) · Langmuir · doi:10.1021/la304746p · Cited by 137
Differentiation of Mouse Induced Pluripotent Stem Cells into a Multipotent Keratinocyte Lineage
Bilousova, G., Chen, J., & Roop, D. R. (2010) · Journal of Investigative Dermatology · doi:10.1038/jid.2010.364 · Cited by 136
Heidi Au, H. T., Cui, B., Chu, Z. E., Veres, T., & Radisic, M. (2009) · Lab Chip · doi:10.1039/b810034a · Cited by 135
Self-citationMicrofluidic Gradient-Generating Device for Pharmacological Profiling
Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O. (2005) · Analytical Chemistry · doi:10.1021/ac050218+ · Cited by 135
Breast Cancer Cell Invasion into a Three Dimensional Tumor-Stroma Microenvironment
Truong, D., Puleo, J., Llave, A., Mouneimne, G., Kamm, R. D., & Nikkhah, M. (2016) · Scientific Reports · doi:10.1038/srep34094 · Cited by 135
Lanfer, B., Seib, F. P., Freudenberg, U., Stamov, D. R., Bley, T., Bornhäuser, M., & Werner, C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.039 · Cited by 134
Ravichandran, R., Sridhar, R., Venugopal, J. R., Sundarrajan, S., Mukherjee, S., & Ramakrishna, S. (2013) · Macromolecular Bioscience · doi:10.1002/mabi.201300407 · Cited by 133
Goral, V. N., Hsieh, Y., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A. (2010) · Lab on a Chip · doi:10.1039/c0lc00135j · Cited by 133
Lee, H., Boccazzi, P., Ram, R. J., & Sinskey, A. J. (2006) · Lab on a Chip · doi:10.1039/b608014f · Cited by 133
Booth, R., & Kim, H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1086-5 · Cited by 132
Köse, M. E., Carroll, B. F., & Schanze, K. S. (2005) · Langmuir · doi:10.1021/la050997p · Cited by 131
Ahadian, S., Ramón‐Azcón, J., Ostrovidov, S., Camci‐Unal, G., Hosseini, V., Kaji, H., Ino, K., Shiku, H., Khademhosseini, A., & Matsue, T. (2012) · Lab on a Chip · doi:10.1039/c2lc40479f · Cited by 131
Self-citationMicro- and nanofabrication of chitosan structures for regenerative engineering
Jiang, T., Deng, M., James, R., Nair, L. S., & Laurencin, C. T. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.07.003 · Cited by 131
Huang, Y., Williams, J. C., & Johnson, S. M. (2012) · Lab on a Chip · doi:10.1039/c2lc21142d · Cited by 130
Serum‐free media for the production of human mesenchymal stromal cells: a review
Gottipamula, S., Muttigi, M. S., Kolkundkar, U., & Seetharam, R. N. (2013) · Cell Proliferation · doi:10.1111/cpr.12063 · Cited by 129
Hydrogel-coated microfluidic channels for cardiomyocyte culture
Annabi, N., Selimović, Š., Acevedo Cox, J. P., Ribas, J., Afshar Bakooshli, M., Heintze, D., Weiss, A. S., Cropek, D., & Khademhosseini, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50252j · Cited by 129
Dynamic Changes in Myocardial Matrix and Relevance to Disease: Translational Perspectives
Li, A.-H., Liu, P. P., Villarreal, F. J., & Garcia, R. A. (2014) · Circulation Research · doi:10.1161/circresaha.114.302819 · Cited by 129
Membrane-Based PDMS Microbioreactor for Perfused 3D Primary Rat Hepatocyte Cultures
Ostrovidov, S., Jiang, J., Sakai, Y., & Fujii, T. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048560.96140.ca · Cited by 127
The future of the patient-specific Body-on-a-chip
Williamson, A., Singh, S., Fernekorn, U., & Schober, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50237f · Cited by 126
A Fibrin-based Bioengineered Ocular Surface With Human Corneal Epithelial Stem Cells
Han, B., Schwab, I. R., Madsen, T., & Isseroff, R. R. (2002) · Cornea · doi:10.1097/00003226-200207000-00013 · Cited by 126
Layered Patterning of Hepatocytes in Co-Culture Systems using Microfabricated Stencils
Cho, C. H., Park, J., Tilles, A. W., Francois Berthiaume, B., Toner, M., & Yarmush, M. L. (2010) · BioTechniques · doi:10.2144/000113317 · Cited by 126
Jackson, E. L., & Lu, H. (2016) · Integrative Biology · doi:10.1039/c6ib00039h · Cited by 126
An integrated microfluidic device for large-scale in situ click chemistry screening
Wang, Y., Lin, W., Liu, K., Lin, R. J., Selke, M., Kolb, H. C., Zhang, N., Zhao, X., Phelps, M. E., Shen, C. K.-F., et al. (2009) · Lab on a Chip · doi:10.1039/b907430a · Cited by 125
Detection of Cardiac Biomarkers Using Single Polyaniline Nanowire-Based Conductometric Biosensors
Lee, I., Luo, X., Huang, J., Cui, X. T., & Yun, M. (2012) · Biosensors · doi:10.3390/bios2020205 · Cited by 124
Recent developments and applications of chemiluminescence sensors
Zhang, Z., Zhang, S., & Zhang, X. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.11.069 · Cited by 124
A pumpless multi‐organ‐on‐a‐chip (MOC) combined with a pharmacokinetic–pharmacodynamic (PK–PD) model
Lee, H., Kim, D. S., Ha, S. K., Choi, I., Lee, J. M., & Sung, J. H. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26087 · Cited by 124
Biosensing using straight long-range surface plasmon waveguides
Krupin, O., Asiri, H., Wang, C., Tait, R. N., & Berini, P. (2013) · Optics Express · doi:10.1364/oe.21.000698 · Cited by 122
Co-culture of neurons and glia in a novel microfluidic platform
Majumdar, D., Gao, Y., Li, D., & Webb, D. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.024 · Cited by 121
Rossini, A., Zacheo, A., Mocini, D., Totta, P., Facchiano, A., Castoldi, R., Sordini, P., Pompilio, G., ABENI, D. D., Capogrossi, M. C., et al. (2008) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2008.01.009 · Cited by 120
Sellgren, K. L., Hawkins, B. T., & Grego, S. (2015) · Biomicrofluidics · doi:10.1063/1.4935594 · Cited by 119
Tavana, H., Zamankhan, P., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9543-5 · Cited by 117
Investigation of ifosfamide nephrotoxicity induced in a liver–kidney co‐culture biochip
Snouber, L. C., Aninat, C., Grsicom, L., Madalinski, G., Brochot, C., Poleni, P. E., Razan, F., Guguen‐Guillouzo, C., Legallais, C., Corlu, A., et al. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24707 · Cited by 117
Functional Cardiac Tissue Engineering
Liau, B., Zhang, D., & Bursac, N. (2012) · Regenerative Medicine · doi:10.2217/rme.11.122 · Cited by 117
Efficient One‐Step Production of Microencapsulated Hepatocyte Spheroids with Enhanced Functions
Chan, H. F., Zhang, Y., & Leong, K. W. (2016) · Small · doi:10.1002/smll.201502932 · Cited by 117
Alépée, N., Tornier, C., Robert, C., Amsellem, C., Roux, M.-H., Doucet, O., Pachot, J., Méloni, M., & de Fraissinette, A. D. B. (2009) · Toxicology in Vitro · doi:10.1016/j.tiv.2009.08.024 · Cited by 114
A Novel Bioreactor for Stimulating Skeletal Muscle In Vitro
Donnelly, K., Khodabukus, A., Philp, A., Deldicque, L., Dennis, R. G., & Baar, K. (2010) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2009.0125 · Cited by 114
Ning, W., Song, R., Li, C., Park, E., Mohsenin, A., Choi, A. M. K., & Choi, M. E. (2002) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00151.2002 · Cited by 113
Bruce, A., Evans, R., Mezan, R., Shi, L., Moses, B. S., Martin, K. H., Gibson, L. F., & Yang, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140506 · Cited by 112
Research works printed but not linked: 46
- Skalak R., 1988, Tissue Engineering
- Vanderburgh J., 2016, Ann. Biomed. Eng., 45, 1
- 10.1038/nbt.2989 · DOI · Paper page
- McCarty W. J., 2015, J. Visualized Exp., 103, e53078
- 10.1038/nmat4570 · DOI · Paper page
- 10.1002/jbm.a.10082 · DOI
- 10.1016/j.progpolymsci.2011.06.003 · DOI · Paper page
- 10.1073/pnas.1210580109 · DOI · Paper page
- Getgood A., 2009, Bone Joint J., 91, 565
- Bencherif S. A., 2009, Synthesis, Characterization, and Evaluation of Biodegradable Polymers and Biomimetic Hydrogel Scaffolds for Biomedical Applications
- 10.1046/j.1537-2995.1990.30891020337.x · DOI · Paper page
- 10.1016/S0142-9612(99)00006-X · DOI · Paper page
- 10.1016/j.biomaterials.2005.03.016 · DOI · Paper page
- Izydorczyk M. S., 2005, Food Carbohydrates: Chemistry, Physical Properties, and Applications, 293
- 10.1016/j.biomaterials.2008.10.004 · DOI · Paper page
- 10.1039/c2sm07418d · DOI
- 10.1126/science.1140171 · DOI · Paper page
- Mohammadi Y., 2007, Iran. Polym. J., 16, 57
- 10.1002/bit.21360 · DOI · Paper page
- 10.1002/bit.25659 · DOI · Paper page
- 10.1126/science.1188302 · DOI · Paper page
- Stacey G., 2001, Primary Cell Cultures and Immortal Cell Lines, eLS
- Blasco M. A., 2016, Cancer Epidemiol., Biomarkers Prev.
- 10.1016/j.actbio.2016.12.009 · DOI · Paper page
- 10.1038/nmeth.2524 · DOI · Paper page
- 10.1038/nmat3404 · DOI · Paper page
- Nunes S. S., 2016, ACS Biomater. Sci. Eng.
- 10.1126/scitranslmed.3004249 · DOI · Paper page
- 10.1002/bit.21360 · DOI · Paper page
- 10.1021/ac050218 · doi:10.1021/ac050218
- 10.1016/j.actbio.2015.11.047 · DOI · Paper page
- Zhang Y. S., 2017, Proc. Natl. Acad. Sci. USA, E2293
- Shaegh S. A. M., 2016, Biomicrofluidics, 10, 044111, 10.1063/1.4955155 · DOI · Paper page
- Schmid F. X., 2001, Biological Macromolecules: UV‐visible Spectrophotometry, eLS, Wiley
- 10.1021/ac303159b · DOI
- Liu Y., 2012, Biomaterials, 33, 7345
- Yu H., 2016, Acta Pharmacol. Sin., 37, 107
- 10.1038/nmat4590 · DOI · Paper page
- Romil Saxena N. D. T., 2015, Hepatology, 30, 8
- 2010, G. Minotti, Cardiotoxicity of Non‐Cardiovascular Drugs
- Komai Y., 1991, Invest. Ophthalmol. Visual Sci., 32, 2244
- 10.1039/c2lc40074j · DOI · Paper page
- Lee J. H., 2012, J. Drug Delivery, 2012, 527516
- 10.1039/c3lc50217a · DOI · Paper page
- 10.1039/c3lc50293g · DOI
- 10.1038/nmeth.2524 · DOI · Paper page
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Self-citationOrgans-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Engineered materials for organoid systems
Kratochvil, M. J., Seymour, A. J., Li, T. L., Paşca, S. P., Kuo, C. J., & Heilshorn, S. C. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0129-9 · Cited by 414
Zamprogno, P., Wüthrich, S., Achenbach, S., Thoma, G., Stucki, J. D., Hobi, N., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Geiser, T., et al. (2021) · Communications Biology · doi:10.1038/s42003-021-01695-0 · Cited by 348
Immunomodulatory Biomaterials for Tissue Repair
Whitaker, R., Hernaez-Estrada, B., Hernandez, R. M., Santos-Vizcaino, E., & Spiller, K. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00895 · Cited by 338
Metadata
- Authors
- Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., Mandla, S., Korolj, A., & Radisic, M.
- Affiliations
- University of Toronto (CA)
- Institute of Biomaterials and Biomedical Engineering University of Toronto Toronto M5S 3G9 Ontario Canada
- Corresponding author
- Radisic, Milica
- ORCID
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-10-16
- Volume
- 7
- Issue
- 2
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2766424371
- Cited by
- 315
- References
- 610
- Citations by year
- 2026: 9 · 2025: 31 · 2024: 29 · 2023: 51 · 2022: 38 · 2021: 50 · 2020: 45 · 2019: 32 · 2018: 29
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Update notices
- correction (2018-07-25)
- Open access
- closed
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- organ-on-a-chip, biomaterials, stem cells, tissue engineering, disease modeling, drug discovery, liver, skeletal muscle, myocardium, cancer, lung, skin, bone, brain, cell behavior, tissue morphogenesis
- MeSH terms
- Biocompatible Materials, Humans, Tissue Engineering, Drug Discovery, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.