Super-resolution Ultrasound Imaging
Open accessThe DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Abstract
The majority of exchanges of oxygen and nutrients are performed around vessels smaller than 100 um, allowing cells to thrive everywhere in the body. Pathologies such as cancer, diabetes or arteriosclerosis can profoundly alter the microvasculature. Unfortunately, medical imaging modalities only provide indirect observation at this scale. Inspired by optical microscopy, ultrasound localization microscopy has bypassed the classical compromise between penetration and resolution in ultrasonic imaging. By localizing individual injected microbubbles and tracking their displacement with a subwavelength resolution, vascular and velocity maps can be produced at the scale of the micrometer. Ultrasound super-resolution has also been performed through signal fluctuations with the same type of contrast agents, or through switching on and off nano-sized phase change contrast agents. These techniques are now being applied pre-clinically and clinically for the imaging of the microvasculature of the brain, kidney, skin, tumors and lymph nodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Hungarian method for the assignment problem
Kuhn, H. W. (1955) · Naval Research Logistics Quarterly · doi:10.1002/nav.3800020109 · Cited by 13,120
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Wardlaw, J. M., Smith, E. E., Biessels, G. J., Cordonnier, C., Fazekas, F., Frayne, R., Lindley, R. I., O'Brien, J. T., Barkhof, F., Benavente, O. R., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70124-8 · Cited by 5,544
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 1×
“Additional approaches such as photo-acoustics (Wang and Hu 2012) and functional ultrasound”
MethodAlgorithms for the Assignment and Transportation Problems
Munkres, J. (1957) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0105003 · Cited by 3,986
Gorelick, P. B., Scuteri, A., Black, S. E., DeCarli, C., Greenberg, S. M., Iadecola, C., Launer, L. J., Laurent, S., Lopez, O. L., Nyenhuis, D., et al. (2011) · Stroke · doi:10.1161/str.0b013e3182299496 · Cited by 3,811
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Pantoni, L. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70104-6 · Cited by 3,405
Neurovascular pathways to neurodegeneration in Alzheimer’s disease and other disorders
Zlokovic, B. V. (2011) · Nature Reviews Neuroscience · doi:10.1038/nrn3114 · Cited by 2,969
Neurovascular regulation in the normal brain and in Alzheimer's disease
Iadecola, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1387 · Cited by 2,213 · cited 1×
“In some noble organs such as the brain, the complexity extends to an even higher level, as tiny vessels are intimately connected and communicating with the neuronal system via the glial system and particularly astrocytes and pericytes (Iadecola, 2004).”
BackgroundLivescu, K., Bezman, A., Borges, N., Yung, L.-Y., Çetin, Ö., Frankel, J., King, S., Magimai.-Doss, M., Chi, X., & Lavoie, L. (2007) · Edinburgh Research Explorer (University of Edinburgh) · Cited by 2,145
Compressed sensing : theory and applications
Eldar, Y. C., & Kutyniok, G. (2012) · Cited by 2,030
Self-citationMa, J., & Jemal, A. (2013) · Breast Cancer Metastasis and Drug Resistance · doi:10.1007/978-1-4614-5647-6_1 · Cited by 1,907
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
iDISCO: A Simple, Rapid Method to Immunolabel Large Tissue Samples for Volume Imaging
Renier, N., Wu, Z., Simon, D. J., Yang, J., Ariel, P., & Tessier-Lavigne, M. (2014) · Cell · doi:10.1016/j.cell.2014.10.010 · Cited by 1,818
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationDeterminants of tumor blood flow: a review.
Jain, R. K. (1988) · PubMed · Cited by 1,379
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Self-citationUltrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
Folkman, J. (2006) · Annual Review of Medicine · doi:10.1146/annurev.med.57.121304.131306 · Cited by 1,209
Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Dertinger, T., Colyer, R., Iyer, G., Weiss, S., & Enderlein, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907866106 · Cited by 1,130
Robust Recovery of Signals From a Structured Union of Subspaces
Eldar, Y. C., & Mishali, M. (2009) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2030471 · Cited by 1,044
Self-citationThree-dimensional imaging of solvent-cleared organs using 3DISCO
Ertürk, A., Becker, K., Jährling, N., Mauch, C. P., Hojer, C. D., Egen, J. G., Hellal, F., Bradke, F., Sheng, M., & Dodt, H.-U. (2012) · Nature Protocols · doi:10.1038/nprot.2012.119 · Cited by 992
Blood-brain barrier opening in Alzheimer’s disease using MR-guided focused ultrasound
Lipsman, N., Meng, Y., Bethune, A. J., Huang, Y., Lam, B., Masellis, M., Herrmann, N., Heyn, C., Aubert, I., Boutet, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04529-6 · Cited by 950
Self-citationEchocardiography of the Aortic Root
Gramiak, R., & Shah, P. M. (1968) · Investigative Radiology · doi:10.1097/00004424-196809000-00011 · Cited by 930
Fourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757 · cited 1×
“…for guiding and monitoring interventions in the brain, such as ultrasound-mediated opening of the blood brain barrier (Hynynen et al. 2001; McDannold et al. 2006; Carpentier et al. 2016; Lipsman et al. 2018; Mainprize et al. 2019) and sonothrombolysis (Culp et al. 2011; Pajek et al. 2014).”
BackgroundWeidner, N. (1995) · Breast Cancer Research and Treatment · doi:10.1007/bf00666038 · Cited by 718
Serial two-photon tomography for automated ex vivo mouse brain imaging
Ragan, T., Kadiri, L. R., Venkataraju, K. U., Bahlmann, K., Sutin, J., Taranda, J., Arganda-Carreras, I., Kim, Y., Seung, H. S., & Osten, P. (2012) · Nature Methods · doi:10.1038/nmeth.1854 · Cited by 669
Mainprize, T., Lipsman, N., Huang, Y., Meng, Y., Bethune, A., Ironside, S., Heyn, C., Alkins, R., Trudeau, M., Sahgal, A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-36340-0 · Cited by 618
Self-citationAcoustic droplet vaporization for therapeutic and diagnostic applications
Kripfgans, O. D., Fowlkes, J. B., Miller, D. L., Eldevik, O. P., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00262-3 · Cited by 572
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Self-citationVEGF: once regarded as a specific angiogenic factor, now implicated in neuroprotection
Storkebaum, E., Lambrechts, D., & Carmeliet, P. (2004) · BioEssays · doi:10.1002/bies.20092 · Cited by 507
In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
Christensen-Jeffries, K. M., Browning, R. J., Tang, M., Dunsby, C. W., & Eckersley, R. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359650 · Cited by 489
Self-citationUnderwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
McDannold, N., Vykhodtseva, N., & Hynynen, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/4/003 · Cited by 447
Self-citationMicrobubble contrast agents: a new era in ultrasound
Blomley, M. J. K., Cooke, J. C., Unger, E. C., Monaghan, M. J., & Cosgrove, D. O. (2001) · BMJ · doi:10.1136/bmj.322.7296.1222 · Cited by 426
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Self-citationAcoustic reporter genes for noninvasive imaging of microorganisms in mammalian hosts
Bourdeau, R. W., Lee-Gosselin, A., Lakshmanan, A., Farhadi, A., Kumar, S. R., Nety, S. P., & Shapiro, M. G. (2018) · Nature · doi:10.1038/nature25021 · Cited by 396
Ultrasound contrast imaging: current and new potential methods
Frinking, P. J. A., Bouakaz, A., Kirkhorn, J., Ten Cate, F. J., & de Jong, N. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00229-5 · Cited by 378
Mechanisms of contrast agent destruction
Chomas, J. E., Dayton, P., Allen, J., Morgan, K., & Ferrara, K. W. (2001) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.896136 · Cited by 362
Self-citation3D ultrafast ultrasound imaging in vivo
Provost, J., Papadacci, C., Arango, J. E., Imbault, M., Fink, M., Gennisson, J.-L., Tanter, M., & Pernot, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/l1 · Cited by 356
Self-citationNon-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Pathophysiology of the Neurovascular Unit: Disease Cause or Consequence?
Stanimirovic, D. B., & Friedman, A. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.25 · Cited by 346
Microbubble ultrasound contrast agents: A review
Stride, E., & Saffari, N. (2003) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544110360729072 · Cited by 337
Soeller, C., & Cannell, M. B. (1999) · Circulation Research · doi:10.1161/01.res.84.3.266 · Cited by 331
Webb, A. J. S., Simoni, M., Mazzucco, S., Kuker, W., Schulz, U., & Rothwell, P. M. (2012) · Stroke · doi:10.1161/strokeaha.112.655837 · Cited by 304 · cited 1×
“As a consequence, pathologic changes of the mechanical properties of arteries strongly affect the transmission of blood to tiny vessels (Webb et al. 2012).”
BackgroundSubharmonic imaging of contrast agents
Forsberg, F., Shi, W. T., & Goldberg, B. B. (2000) · Ultrasonics · doi:10.1016/s0041-624x(99)00148-1 · Cited by 303
Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03973-8 · Cited by 295
Self-citationPugsley, M. K., & Tabrizchi, R. (2000) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(00)00125-8 · Cited by 290
Pichardo, S., Sin, V. W., & Hynynen, K. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/014 · Cited by 287
Self-citationBeyond 30 MHz [applications of high-frequency ultrasound imaging]
Lockwood, G. R., Turnball, D. H., Christopher, D. A., & Foster, F. S. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544513 · Cited by 286
Song, P., Trzasko, J. D., Manduca, A., Huang, R., Kadirvel, R., Kallmes, D. F., & Chen, S. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2017.2778941 · Cited by 285
Acoustic super-resolution with ultrasound and microbubbles
Viessmann, O. M., Eckersley, R. J., Christensen-Jeffries, K., Tang, M. X., & Dunsby, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/18/6447 · Cited by 277
Self-citationFayad, Z. A., Fuster, V., Nikolaou, K., & Becker, C. (2002) · Circulation · doi:10.1161/01.cir.0000034392.34211.fc · Cited by 276
Ultrasound-induced encapsulated microbubble phenomena
Postema, M., van Wamel, A., Lancée, C. T., & de Jong, N. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.02.010 · Cited by 275
Brain motion: measurement with phase-contrast MR imaging.
Enzmann, D. R., & Pelc, N. J. (1992) · Radiology · doi:10.1148/radiology.185.3.1438741 · Cited by 273
Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citationLin, F., Shelton, S. E., Espíndola, D., Rojas, J. D., Pinton, G., & Dayton, P. A. (2017) · Theranostics · doi:10.7150/thno.16899 · Cited by 260
Self-citationDesign of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons
Sheeran, P. S., Luois, S. H., Mullin, L. B., Matsunaga, T. O., & Dayton, P. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.021 · Cited by 254
Self-citationA super‐resolution ultrasound method for brain vascular mapping
OˈReilly, M. A., & Hynynen, K. (2013) · Medical Physics · doi:10.1118/1.4823762 · Cited by 242
Self-citationUltrasound imaging of gene expression in mammalian cells
Farhadi, A., Ho, G. H., Sawyer, D. P., Bourdeau, R. W., & Shapiro, M. G. (2019) · Science · doi:10.1126/science.aax4804 · Cited by 242
Super-Resolution Ultrasound Localization Microscopy Through Deep Learning
van Sloun, R. J. G., Solomon, O., Bruce, M., Khaing, Z. Z., Wijkstra, H., Eldar, Y. C., & Mischi, M. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3037790 · Cited by 213
Self-citationRecent advances in molecular, multimodal and theranostic ultrasound imaging
Kiessling, F., Fokong, S., Bzyl, J., Lederle, W., Palmowski, M., & Lammers, T. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.013 · Cited by 201
Self-citationFunctional ultrasound neuroimaging: a review of the preclinical and clinical state of the art
Deffieux, T., Demene, C., Pernot, M., & Tanter, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.02.001 · Cited by 195
Self-citationHingot, V., Errico, C., Heiles, B., Rahal, L., Tanter, M., & Couture, O. (2019) · Scientific Reports · doi:10.1038/s41598-018-38349-x · Cited by 194
Self-citationUltrasound contrast plane wave imaging
Couture, O., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2508 · Cited by 190
Self-citationAcoustic droplet vaporization is initiated by superharmonic focusing
Shpak, O., Verweij, M., Vos, H. J., de Jong, N., Lohse, D., & Versluis, M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1312171111 · Cited by 190
Sono-activated ultrasound localization microscopy
Desailly, Y., Couture, O., Fink, M., & Tanter, M. (2013) · Applied Physics Letters · doi:10.1063/1.4826597 · Cited by 187
Self-citationEvaluation of tumor angiogenesis with US: Imaging, Doppler, and contrast agents
Ferrara, K. W., Merritt, C. R. B., Burns, P. N., Stuart Foster, F., Mattrey, R. F., & Wickline, S. A. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80631-5 · Cited by 186
Simulated Capillary Blood Flow Measurement Using a Nonlinear Ultrasonic Contrast Agent
Schrope, B., Newhouse, V. L., & Uhlendorf, V. (1992) · Ultrasonic Imaging · doi:10.1177/016173469201400204 · Cited by 185
Ultrafast 3D Ultrasound Localization Microscopy Using a 32 $\times$ 32 Matrix Array
Heiles, B., Correia, M., Hingot, V., Pernot, M., Provost, J., Tanter, M., & Couture, O. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2890358 · Cited by 174
Self-citationDetection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images
Ackermann, D., & Schmitz, G. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2500266 · Cited by 172
Self-citationMontgomery, M., & McCrone, S. H. (2010) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2010.05439.x · Cited by 169
Ultrasound localization microscopy to image and assess microvasculature in a rat kidney
Foiret, J., Zhang, H., Ilovitsh, T., Mahakian, L., Tam, S., & Ferrara, K. W. (2017) · Scientific Reports · doi:10.1038/s41598-017-13676-7 · Cited by 169
Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb
Harput, S., Christensen-Jeffries, K. M., Brown, J., Li, Y., Williams, K. J., Davies, A. H., Eckersley, R. J., Dunsby, C. W., & Tang, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2824846 · Cited by 169
Self-citationNonspherical Oscillations of Ultrasound Contrast Agent Microbubbles
Dollet, B., van der Meer, S. M., Garbin, V., de Jong, N., Lohse, D., & Versluis, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.01.020 · Cited by 165
Microbubble ultrasound super-localization imaging (MUSLI)
Couture, O., Besson, B., Montaldo, G., Fink, M., & Tanter, M. (2011) · 2011 IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.6293576 · Cited by 164
Self-citationUltrasound contrast agents as markers of vascularity and microcirculation
Greis, C. (2009) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2009-1216 · Cited by 162
Investigation of Vaporized Submicron Perfluorocarbon Droplets as an Ultrasound Contrast Agent
Reznik, N., Williams, R., & Burns, P. N. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.001 · Cited by 160
Label-free photoacoustic nanoscopy
Danielli, A., Maslov, K. I., Garcia-Uribe, A., Winkler, A. M., Li, C., Wang, L., Chen, Y., Dorn, G. W., & Wang, L. V. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086006 · Cited by 160
The Pathology of “Vascular Dementia”: A Critical Update
Jellinger, K. A. (2008) · Journal of Alzheimer's Disease · doi:10.3233/jad-2008-14110 · Cited by 155
Nanoparticles with Multiple Perfluorocarbons for Controllable Ultrasonically Induced Phase Shifting
Kawabata, K.-I., Sugita, N., Yoshikawa, H., Azuma, T., & Umemura, S. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.4548 · Cited by 140
4D microvascular imaging based on ultrafast Doppler tomography
Demené, C., Tiran, E., Sieu, L.-A., Bergel, A., Gennisson, J. L., Pernot, M., Deffieux, T., Cohen, I., & Tanter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.014 · Cited by 139
Self-citationSubwavelength motion-correction for ultrafast ultrasound localization microscopy
Hingot, V., Errico, C., Tanter, M., & Couture, O. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.008 · Cited by 135
Self-citationQuantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography
Shelton, S. E., Lee, Y. Z., Lee, M., Chérin, E., Foster, F. S., Aylward, S., & Dayton, P. A. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.02.012 · Cited by 131
Self-citationSUSHI: Sparsity-Based Ultrasound Super-Resolution Hemodynamic Imaging
Bar‐Zion, A., Solomon, O., Tremblay‐Darveau, C., Adam, D., & Eldar, Y. C. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2873380 · Cited by 128
Self-citationGessner, R. C., Lukacs, M., Lee, M., Chérin, E., Foster, F. S., & Dayton, P. A. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1615 · Cited by 125
Self-citationFast Vascular Ultrasound Imaging With Enhanced Spatial Resolution and Background Rejection
Bar‐Zion, A., Tremblay‐Darveau, C., Solomon, O., Adam, D., & Eldar, Y. C. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2600372 · Cited by 123
Self-citationBurns, Powers, Simpson, Brezina, Kolin, Chin, Uhlendorf, & Fritzsch (1994) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1994.401886 · Cited by 122
3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
Harput, S., Christensen-Jeffries, K. M., Ramalli, A., Brown, J., Zhu, J., Zhang, G., Leow, C. H., Toulemonde, M. E. G., Boni, E., Tortoli, P., et al. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2943646 · Cited by 121
Self-citationMultiwave imaging and super resolution
Fink, M., & Tanter, M. (2010) · Physics Today · doi:10.1063/1.3326986 · Cited by 119
Self-citationSuper-Resolution Ultrasound Imaging in Vivo with Transient Laser-Activated Nanodroplets
Luke, G. P., Hannah, A. S., & Emelianov, S. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00108 · Cited by 119
Grills, I. S., Kestin, L. L., Goldstein, N. S., Mitchell, C. K., Martinez, A. A., Ingold, J. A., & Vicini, F. A. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00017-8 · Cited by 110
Gessner, R. C., Aylward, S., & Dayton, P. A. (2012) · Radiology · doi:10.1148/radiol.12112000 · Cited by 108
Self-citationClinical Pilot Application of Super-Resolution US Imaging in Breast Cancer
Dencks, S., Piepenbrock, M., Opacic, T., Krauspe, B., Stickeler, E., Kiessling, F. M., & Schmitz, G. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2872067 · Cited by 108
Self-citationLocalization optoacoustic tomography
Deán‐Ben, X. L., & Razansky, D. (2018) · Light Science & Applications · doi:10.1038/lsa.2018.4 · Cited by 105
Imaging tumor vascularity by tracing single microbubbles
Siepmann, M., Schmitz, G., Bzyl, J., Palmowski, M., & Kiessling, F. M. (2011) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.0476 · Cited by 101
Self-citationCulp, W. C., Flores, R., Brown, A. T., Lowery, J. D., Roberson, P. K., Hennings, L. J., Woods, S. D., Hatton, J. H., Culp, B. C., Skinner, R. D., et al. (2011) · Stroke · doi:10.1161/strokeaha.110.607150 · Cited by 99
Zhang, G., Harput, S., Lin, S., Christensen-Jeffries, K. M., Leow, C. H., Brown, J., Dunsby, C. W., Eckersley, R. J., & Tang, M.-X. (2018) · Applied Physics Letters · doi:10.1063/1.5029874 · Cited by 96
Self-citationMicrobubble Axial Localization Errors in Ultrasound Super-Resolution Imaging
Christensen-Jeffries, K. M., Harput, S., Brown, J., Wells, P. N. T., Aljabar, P., Dunsby, C. W., Tang, M., & Eckersley, R. J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2741067 · Cited by 95
Self-citationDeep Learning for Super-resolution Vascular Ultrasound Imaging
van Sloun, R. J. G., Solomon, O., Bruce, M., Khaing, Z. Z., Eldar, Y. C., & Mischi, M. (2019) · ICASSP 2019 - 2019 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2019.8683813 · Cited by 83
Self-citationContrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images
Desailly, Y., Tissier, A.-M., Corréas, J.-M., Wintzenrieth, F., Tanter, M., & Couture, O. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/31 · Cited by 81
Self-citationPajek, D., Burgess, A., Huang, Y., & Hynynen, K. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.03.026 · Cited by 78
Self-citationExploiting Flow Dynamics for Superresolution in Contrast-Enhanced Ultrasound
Solomon, O., van Sloun, R. J. G., Wijkstra, H., Mischi, M., & Eldar, Y. C. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2926062 · Cited by 70
Self-citationImaging Tumor Vascularization for Detection and Diagnosis of Breast Cancer
Heijblom, M., Klaase, J. M., van den Engh, F. M., van Leeuwen, T. G. J. M., Steenbergen, W., & Manohar, S. (2011) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500227 · Cited by 66
Ghosh, D., Peng, J., Brown, K., Sirsi, S. R., Mineo, C., Shaul, P. W., & Hoyt, K. (2019) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14956 · Cited by 66
Super-Resolution Imaging Through the Human Skull
Soulioti, D., Espíndola, D., Dayton, P. A., & Pinton, G. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2937733 · Cited by 63
Self-citationMarien, K. M., Croons, V., Waumans, Y., Sluydts, E., Schepper, S. D., Andries, L. J., Waelput, W., Fransén, E., Vermeulen, P. B., Kockx, M. M., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161496 · Cited by 55
Investigation of Microbubble Detection Methods for Super-Resolution Imaging of Microvasculature
Brown, J., Christensen-Jeffries, K. M., Harput, S., Zhang, G., Zhu, J., Dunsby, C. W., Tang, M., & Eckersley, R. J. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2894755 · Cited by 53
Self-citationGhosh, D., Xiong, F., Sirsi, S. R., Shaul, P. W., Mattrey, R. F., & Hoyt, K. (2017) · Medical Physics · doi:10.1002/mp.12606 · Cited by 52
On the Effects of Spatial Sampling Quantization in Super-Resolution Ultrasound Microvessel Imaging
Song, P., Manduca, A., Trzasko, J. D., Daigle, R. E., & Chen, S. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2832600 · Cited by 50
Lin, F., Tsuruta, J. K., Rojas, J. D., & Dayton, P. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.05.014 · Cited by 49
Self-citationUncertainty During Breast Diagnostic Evaluation: State of the Science
Montgomery, M. (2009) · Oncology nursing forum · doi:10.1188/10.onf.77-83 · Cited by 48
Вилов, С. А., Arnal, B., & Bossy, E. (2017) · Optics Letters · doi:10.1364/ol.42.004379 · Cited by 45
Pieczynski, J., Grzybowski, A., Chair of Ophthalmology, U. O. W. A. M., The Voivodal Specialistic Hospital, O., Chair of Ophthalmology, U. O. W. A. M., & Department of Ophthalmology, P. C. H. (2015) · European Ophthalmic Review · doi:10.17925/eor.2015.09.01.49 · Cited by 42
SPARCOM: Sparsity Based Super-resolution Correlation Microscopy
Solomon, O., Eldar, Y. C., Mutzafi, M., & Segev, M. (2019) · SIAM Journal on Imaging Sciences · doi:10.1137/18m1174921 · Cited by 41
Self-citationRadiomic analysis of contrast-enhanced ultrasound data
Theek, B., Opacic, T., Magnuska, Z., Lammers, T., & Kiessling, F. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-29653-7 · Cited by 39
Self-citationSparsity-driven super-resolution in clinical contrast-enhanced ultrasound
van Sloun, R. J. G., Solomon, O., Eldar, Y. C., Wijkstra, H., & Mischi, M. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092945 · Cited by 36
Self-citationAdvances in Human Placental Biomechanics
Mayo, R. P. (2018) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2018.08.001 · Cited by 35
Foroozan, F., O’Reilly, M. A., & Hynynen, K. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2813759 · Cited by 31
Self-citationIadecola, C., Hachinski, V., & Rosenberg, G. A. (2010) · Stroke · doi:10.1161/strokeaha.110.595488 · Cited by 23
Espíndola, D., Lin, F., Soulioti, D., Dayton, P. A., & Pinton, G. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2865903 · Cited by 20
Self-citationQuantification of Vaporised Targeted Nanodroplets Using High-Frame-Rate Ultrasound and Optics
Zhang, G., Lin, S., Leow, C. H., Pang, K. T., Hernández‐Gil, J., Long, N. J., Eckersley, R. J., Matsunaga, T. O., & Tang, M. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.01.009 · Cited by 18
Self-citationSparsity-driven super-localization in clinical contrast-enhanced ultrasound
van Sloun, R. J. G., Solomon, O., Eldar, Y. C., Wijkstra, H., & Mischi, M. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092875 · Cited by 17
Self-citationDencks, S., Opacic, T., Piepenbrock, M., Kiessling, F., & Georg, S. (2017) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2017.8092020 · Cited by 17
Self-citationDynamic Spike Superresolution and Applications to Ultrafast Ultrasound Imaging
Alberti, G. S., Ammari, H. M., Romero, F., & Wintz, T. (2019) · SIAM Journal on Imaging Sciences · doi:10.1137/18m1174775 · Cited by 17
Subwavelength far-field ultrasound drug-delivery
Hingot, V., Bézagu, M., Errico, C., Desailly, Y., Bocheux, R., Tanter, M., & Couture, O. (2016) · Applied Physics Letters · doi:10.1063/1.4967009 · Cited by 15
Self-citationContrast-enhanced ultrasound tractography for 3D vascular imaging of the prostate
van Sloun, R. J. G., Demi, L., Schalk, S. G., Caresio, C., Mannaerts, C. K., Postema, A. W., Molinari, F., van der Linden, H. C., Huang, P., Wijkstra, H., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32982-2 · Cited by 15
Cited by
Radiolabelling of nanomaterials for medical imaging and therapy
Pellico, J., Gawne, P. J., & T. M. de Rosales, R. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00384k · Cited by 304
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
“Contrast agents also offer a powerful complement to fUSI: super-resolution imaging, or ultrasound localization microscopy reviewed in (Christensen-Jeffries et al., 2020) and (Couture et al.”
Background
Metadata
- Authors
- Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., Tanter, M., & van Sloun, R. J. G.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 46
- Issue
- 4
- Pages
- 865-891
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W3000957625
- Cited by
- 558
- References
- 135
- FWCI
- 18.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.